Teledyne CCR-58S Controlled with usb or ethernet Datasheet

Miniature Matrix: MMC Series
Controlled with USB or Ethernet
COAX SWITCHES
PART NUMBER
DESCRIPTION
The MMC Series is an ideal solution that consists of multi-throw, electromechanical
coaxial switches designed to switch a microwave signal from a common input to any of
3, 4, 5, 6, 7 or 8 outputs. The characteristic impedance is 50 Ohms. With the normally
open actuator, all paths are open when the switch is de-energized.
The MMC Series is designed to allow the remote operation of 1 to 2 Single Pole Multi
Throw switches. Remote operation is accomplished via TCP/IP commands to the
Matrix’s Ethernet interface. Switch control is also accessible via the USB virtual serial
port, using the provided command set. Through these interfaces the Coax Switch can
be switched to the desired position and its position can be read for verification. The
default switch position at power up can be set by the user. The MMC will feature a
graphical user interface (GUI), which will enable user to control switches through
graphical icons and visuals.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS (SWITCHES ONLY)
Operating Temperature
–40°C to 65°C
Form Factor
Standard Actuator Life
5,000,000 cycles
Connector Type
SMA, 2.9mm
Weight Non-Terminated
1 Switch
2 Switches
26 oz. (737 g) (max.)
32 oz. (907 g) (max.)
Weight Terminated
1 Switch
2 Switches
54 oz. (1531 g) (max.)
60 oz. (1701 g) (max.)
Multi-Throw,
break before make
Frequency Range
Up to DC-40 GHz
Characteristic Impedance
50 Ohms
Operate Time
15 ms (max.)
Release Time
15 ms (max.)
Actuation Voltage Available
24
Actuation Current, max. @ ambient
Vdc
170mA/switch
TYPICAL RF CHARACTERISTICS
Frequency
DC–6 GHz
6–12 GHz
12–18 GHz
18–26.5 GHz
26.5–34 GHz*
34-40 GHz*
(40 Option)
(40 Option)
0.20
0.40
0.50
0.90
1.00
1.50
70
60
60
50
50
50
1.25:1
1.40:1
1.50:1
1.80:1
1.90:1
2.00:1
Insertion Loss, dB, typ.
Isolation, dB, typ..
VSWR , typ.
For specific RF performance data please refer to Coax Switch Part number list in Glossary (page 5)
ADDITIONAL INFORMATION
INCLUDED ITEMS
Interface
USB or TCP/IP
• AC/DC Power Adapter
• USB Cable
Host Operating System
Windows, MAC, Linux
• Power Cord
• Installation CD
Operating System
Embedded
• Ethernet Cable
BUILD YOUR BOX
Number of Switches (Select One):
Non-Terminated
Frequency Range (Select One):
(Enclosure A)
Terminated
(Enclosure B)
1 (Enclosure A)
1 (Enclosure B)
2 (Enclosure A)
2 (Enclosure B)
SP5T
SP4T
SP6T
SP7T*
SP8T*
DC-26.5GHz
DC-40GHz
Remote Control (Select One):
USB Only
USB & Ethernet
Actuation Type (Select One):
Number of Throws (Select One):
SP3T
DC-18GHz
Normally Open
Latching**
* Only available in Normally Open Models, up to 18GHz
See Page 5, for Part Number List for switches used
** Only available in Enclosure B
For additional options, please contact factory.
© 2017 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
MMC SERIES Page 1
MMC SERIES\022017\Q1
Miniature Matrix: MMC Series
Controlled with USB or Ethernet
COAX SWITCHES
MECHANICAL OUTLINE FOR ENCLUSRE A
Max. Length with Switches= 7.75 (196.85)
Enclosure A: UP TO 2 NON-TERMINATED SPMT
SWITCHES
FRONT VIEW
BLOCK DIAGRAM EXAMPLE
24 DC Input
TCP/IP
MICROCONTROLLER
USB
MMC SERIES Page 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2016 TELEDYNE COAX SWITCHES
MMC SERIES\052016\Q2
COAX SWITCHES
Miniature Matrix: MMC Series
Controlled with USB or Ethernet
MECHANICAL OUTLINE FOR ENCLUSRE B
Enclosure B: UP TO 2 TERMINATED SP3T to SP6T
SWITCHES
© 2017 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
MMC SERIES Page 3
MMC SERIES\022017\Q1
Miniature Matrix: MMC Series
Controlled with USB or Ethernet
COAX SWITCHES
MECHANICAL OUTLINE FOR ENCLUSRE B
Enclosure B: UP TO 2 TERMINATED SP7T to SP8T
SWITCHES
ORDERING CODE
Example:
2 F L - HF40T
# of Switches
# of Throws:
C=3
D=4
E=5
F=6
G=7
H=8
Options
Options
None = SMA DC-18GHz
T = Terminated (can stack)
HF26 = SMA DC-26.5GHz
HP40 = 2.92 mm DC-40GHz
F = Failsafe, L = Latching
MMC SERIES Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2016 TELEDYNE COAX SWITCHES
MMC SERIES\052016\Q2
Miniature Matrix: MMC Series
Controlled with USB or Ethernet
COAX SWITCHES
GLOSSARY
Actuator
An actuator is the electromechanical mechanism that
transfers the RF contacts from one position to another upon
DC command.
Ethernet
A high-speed interface used in local area networks (LAN).
Ethernet is also known as IEEE 802.3 standard. DHCP or
Static IP can be configured through a web interface.
Isolation
Isolation is the measure of the power level at the output
connector of an unconnected RF channel as referenced to
the power at the input connector. It is specified in dB below
the input power level.
Magnetic Sensitivity
An electro-mechanical switch can be sensitive to ferrous
materials and external magnetic fields. Neighboring ferrous
materials should be permitted no closer than 0.5 inches and
adjacent external magnetic fields should be limited to a flux
density of less than 5 Gauss.
Multi-Throw Switch
A multi-throw switch is a switch with one input and three
or more output ports. The SPMT can switch a microwave
signal to any of 2, 3, 4, 5, 6, 7 or 8 outputs from a single
common input.
Performance Parameters vs Frequency
Generally speaking, the RF performance of coaxial switches
is frequency dependent. With increasing frequency, VSWR
and insertion loss increase while isolation decreases. All
data sheets specify these three parameters as “worst case”
at the highest operating frequency. If the switch is to be
used over a narrow frequency band, better performance
can be achieved.
Switching Time
Switching time is the total interval beginning with the arrival
of the leading edge of the command pulse at the switch DC
input and ending with the completion of the switch transfer,
including contact bounce. It consists of three parts: (1)
inductive delay in the coil, (2) transfer time of the physical
movement of the contacts, and (3) the bounce time of the
RF contacts. This does not include time added by the
communication interface, application or operating
system.
Universal Serial Bus (USB)
An industry standard that defines the cables, connectors
and communication protocols used in a bus for connection,
communication and power supply between computers and
electronic devices. VCP Driver available for Windows OS,
Mac OS, and Linux.
Termination
When not connected to the common port, RF ports are
shunted to ground via a 50Ω path, rated for 1W.
Part Number List (Non-Terminated) SP3T to SP6T
Frequency
Series
Link
DC-18GHz
CCR-38S
http://www.teledynecoax.com/pdf/coaxialswitches/CCR-38S_CR-38S%20NORMALLY%20OPEN.pdf
DC-26.5GHz
CCR-58S
http://www.teledynecoax.com/pdf/coaxialswitches/CCR-58S_CR-58S%20NORMALLY%20OPEN.pdf
DC-40GHz
CCR-48K
http://www.teledynecoax.com/pdf/coaxialswitches/CCR-48K_NORMALLY_OPEN.pdf
Part Number List (Non-Terminated) SP7T to SP8T
Frequency
Series
Link
DC-18GHz
CCR-58S
http://www.teledynecoax.com/pdf/coaxialswitches/CCR-58S_SP8T_NORMALLY_OPEN.pdf
Part Number List (Terminated) SP3T to SP6T
Frequency
Series
Link
DC-18GHz
CCT-38S
http://www.teledynecoax.com/pdf/coaxialswitches/CCT-38S_CT-38S%20NORMALLY%20OPEN.pdf
DC-26.5GHz
CCT-58S
http://www.teledynecoax.com/pdf/coaxialswitches/CCT-58S_CT-58S%20NORMALLY%20OPEN.pdf
DC-40GHz
CCT-49K
http://www.teledynecoax.com/rfswitches/SwitchPdf/CCT-49K_LATCHING.pdf
Part Number List (Terminated) SP7T to SP8T
Frequency
Series
Link
DC-18GHz
CCT-58S
http://www.teledynecoax.com/pdf/coaxialswitches/CCT-58S%20SP8T%20NORMALLY%20OPEN.pdf
© 2017 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
MMC SERIES Page 5
MMC SERIES\022017\Q1
Similar pages