ETC2 CATTEN-09R0 2db attenuator sma 50 ohm dc to 3ghz Datasheet

CATTEN-02R0
2dB Attenuator
SMA 50 Ohm
DC to 3GHz
Temperature Range:
Rated Power:
Freq Range.
VSWR:
Impedance:
Attenuation Tolerance:
-40°C to +85°C
1 Watt Max
DC - 3GHz
1:1.3 Max
50 Ohms
±0.3 dB Typical
Actual Size
The Attenuator Series offers end users a rugged SMA attenuator housing for
easy connection. Attenuators are available from 1dB to 20dB with 1 Watt power
dissipation. Tolerance matching is used to provide superior temperature tracking
to individual components. Attenuator frequency range from DC to 3GHz.
Rev.: B
Date: 03-04-08
Part Number
Attenuation
CATTEN-01R0
1 dB
CATTEN-01R5
1.5 dB
CATTEN-03R0
3 dB
CATTEN-02R0
2 dB
CATTEN-04R0
4 dB
CATTEN-05R0
5 dB
CATTEN-06R0
6 dB
CATTEN-0200
1 Watt
1 Watt
1 Watt
1 Watt
1 Watt
0.5 Watt
10 dB
20 dB
TEST
2 dB Data
1 Watt
15 dB
CATTEN-09R0
CATTEN-0150
1 Watt
1 Watt
CATTEN-08R0
CATTEN-0100
Power
(Max)
7dB
8dB
9dB
CATTEN-07R0
CATTEN-02R0
2dB Attenuator
SMA 50 Ohm
DC to 3GHz
1 Watt
1 Watt
1 Watt
0.5 Watt
Return Loss
Freq.
(MHz)
Atten
(dB)
Male
(dB)
Female
(dB)
0.3
1.99
56
54
0.5
1.99
56
54
0.8
1.99
56
54
1.0
1.99
56
54
5.0
1.99
55
54
10.0
1.99
55
54
20.0
2.00
54
54
50.0
2.01
49
49
100.0
2.03
44
43
200.0
2.03
39
38
300.0
2.05
36
35
400.0
2.07
34
33
500.0
2.06
32
32
600.0
2.08
31
30
700.0
2.08
29
29
800.0
2.10
28
28
900.0
2.13
27
27
1000.0
2.12
26
26
1500.0
2.18
23
23
2000.0
2.21
20
20
2500.0
2.20
18
17
3000.0
2.36
17
16
Condition of Test
Endurance Test at 70°C per EIA 575-3.14 1000 hours at 70°C, 1.5 hrs “ON”, 0.5 hrs “OFF”
Overload per EIA 575-3.6
Short time overload
Moisture Resistance
per EIA 575-3.10
Thermal Shock
High Temperature Exposure
Low Temperature Exposure
per EIA 575-3.5
per EIA 575-3.7
per EIA 575-3.12
Test Results
0.5dB to 5dB
6dB to 20dB
± 0.2 dB
± 0.3 dB
± 0.2 dB
± 0.2 dB
± 0.2 dB
± 0.2 dB
± 0.2 dB
± 0.3 dB
± 0.3 dB
± 0.3 dB
± 0.3 dB
± 0.3 dB