Omron D8M-D1 Solid state pressure sensors with analog, pulse or frequency output Datasheet

Solid State Pressure Sensors
D8M
Solid State Pressure Sensors with
Analog, Pulse or Frequency Outputs
• Compact housing measures 30L x 30W x 12.4H mm.
• Accept 4 mm OD tubing (D8M-A1, -R1); 3 mm OD tubing
for (D8M-D1, -D2), 6 mm OD tubing for D8M-D82.
• Chemical-resistant plastic (PBT) body.
• Metal shield mounted version (D8M-D82) available.
• IP40 enclosure rating for embedded applications.
• Pre-wired and PCB mounting models available.
Ordering Information
Operating pressure
range
Output signal
Output frequency
Power supply
voltage
Withstand pressure
Model
0 to 4.9 kPa
(0 to 0.71 psi)
Analog,
15 to 1247 mV
--
2.2 ±0.1 VDC
58.8 kPa (8.53 psi) for 3 D8M-A1
minutes
0 to 5.88 kPa
(0 to 0.85 psi)
Pulse count,
1 pulse/9.81 Pa
(1/0.0014 psi)
--
2.2 to 3.4 VDC with
regulator
58.8 kPa
(8.53 psi) for 3 minutes
D8M-D1
0 to 5.88 kPa
(0 to 0.85 psi)
Pulse count,
1 pulse/9.81 Pa
(1/0.0014 psi)
--
2.2 to 3.4 VDC with
regulator
58.8 kPa
(8.53 psi) for 3 minutes
D8M-D2
0 to 4.9 kPa
(0 to 0.71 psi)
Pulse count,
1 pulse/9.81 Pa
(1/0.0014 psi)
--
2.2 to 3.4 VDC with
regulator
19.6 kPa (2.84 psi) for 5
minutes
D8M-D82
0 to 196.13 Pa
(0 to 0.028 psi)
Frequency,
1 kHz/9.81 Pa
(1 kHz/0.0014 psi)
80 to 300 kHz
4.2 to 5.5 VDC with
regulator
3 kPa (0.435 psi) for 10
seconds
D8M-R1
Solid State Pressure Sensors D8M
1
Specifications
■ Electrical Ratings
Item
D8M-A1
D8M-D1
D8M-D2
D8M-D82
D8M-R1
Power supply voltage
2.2 ±0.1 VDC
2.2 to 3.4 VDC with
regulator
2.2 to 3.4 VDC with
regulator
2.2 to 3.4 VDC with
regulator
Current consumption
2.5 mA max.
25 mA max.
25 µA
100 mA ±5% at 3 VDC 10 mA max.
Load resistance
1 MΩ min.
--
--
--
--
Output resistance
500 Ω max.
--
--
--
--
Leakage current
1 mA or less
1 mA or less
1 mA or less
1 mA or less
1 mA or less
Output voltage
15 to 1247 mV
--
--
--
--
Output pulses
--
--
--
--
80 to 300 kHz
Output resolution
(Note 1)
1 pulse/9.81 Pa
1 pulse/9.81 Pa
1 pulse/9.81 Pa
1 kHz/9.81 Pa
Output voltage rate of
change with resistance
load change
1 MΩ or more into 30 -kΩ is made within
2.5%
--
--
--
Output voltage by input
pressure
0.98 kPa = 261 mV
1.96 kPa = 508 mV
3.73 kPa = 951 mV
4.9 kPa = 1247 mV
(Note 1)
--
--
--
--
Operating characteristics ±62 mV initial
4.2 to 5.5 VDC with
regulator
--
--
--
--
±37 mV during test
and after
0 kPa = 30 pulses
0.59 kPa = 60 ±32
pulses
1.96 kPa = 200 ±24
pulses
3.73 kPa = 380 ±24
pulses
5.39 kPa = 530 ±82
pulses
(Note 2)
0 kPa = 30 pulses
0.59 kPa = 60 ±32
pulses
1.96 kPa = 200 ±24
pulses
3.73 kPa = 380 ±24
pulses
5.39 kPa = 550 ±82
pulses
(Note 2)
0 kPa = 30 pulses
0.15 kPa = 45 ±30
pulses
2 kPa = 204 ±15
pulses
4 kPa = 438 ±46
pulses
0 Pa =
180 ±100 kHz;
Incremental change
from 0 value:
49.03 Pa =
5 ±0.9 kHz
73.55 Pa =
7.5 ±1.0 kHz
147.10 Pa =
15 ±0.8 kHz
196.13 Pa =
20 ±1.4 kHz
(Note 2)
±62 mV temperature
influence
--
--
--
--
Note: 1. Output voltage (mV) = Supply voltage V (2.2) x (2.464 x Pressure (kPa)/9.8 x 1000 + 15)
2. Values measured during and after testing.
■ Operating Characteristics
Item
D8M-A1
D8M-D1
D8M-D2
D8M-D82
D8M-R1
Pressure type
Gauge
Pressure range
0 to 4.9 kPa
(0 to 0.71 psi)
0 to 5.88 kPa
(0 to 0.85 psi)
0 to 5.88 kPa
(0 to 0.85 psi)
0 to 4.9 kPa
(0 to 0.71 psi)
0 to 196.13 Pa
(0 to 0.028 psi)
Withstand pressure
5.88 kPa for 3
minutes
58.8 kPa for 3
minutes
58.8 kPa for 3
minutes
19.6 kPa for 5
minutes
3 kPa for 10
seconds
Repeatability/hystersis
±0.5% FS
±0.5% FS
NA
±0.5% FS
±0.5% FS
Non-linearity
characteristics
--
--
--
±2% FS max.
±2% FS max.
Response time
3.0 ms
2.5 ms (pressure)
18 ms max. (switch)
100 ms (discharge)
3 ms (pressure)
32 ms max. (switch)
250 ms (discharge)
1.5 ms (pressure)
30 ms max. (switch)
45 ms (discharge)
3 seconds max.
Operating temperature
(Note)
-30° to 70°C
-30° to 70°C
-30° to 70°C
-10° to 60°C
-20° to 70°C
Storage temperature
(Note)
-40° to 80°C
-40° to 80°C
-40° to 80°C
-20° to 70°C
-30° to 80°C
Operating humidity
25 to 95%
25 to 95%
25 to 95%
25 to 95%
25 to 95%
Note: With no icing or condensation
2
Solid State Pressure Sensors D8M
■ Environmental Characteristics
Item
D8M-A1
D8M-D1
D8M-D2
D8M-D82
D8M-R1
Insulation resistance
100 mΩ min., 250 VDC between lead terminals and the base
Dielectric strength
250 VAC, 50/60 Hz for 1 minute between lead terminals and the base
Degree of protection
NA
IP40
IP40
IP40
IP40
Pressure port
4 mm OD
3 mm OD
3 mm OD
6 mm OD
4 mm OD
Connection method
Solder on PC boards Wiring connector on
top
Wiring connector on
top
Three AWG26 wires, Wiring connector on
115 mm long
bottom
Weight
NA
NA
NA
Material
PBT (polybutylene terephthalate)
NA
500 VAC, 50/60 Hz for
1 minute between terminals and the base
NA
Operation
■ Response Timing Charts
■ Interface Circuit Diagram
D8M-D1, D2, D82
D8M-R1
Model
D8M-D1
D8M-D2
D8M-D82
T1
2.5 ms min.
3.0 ms min.
1.5 ms min.
T2
18 ms max.
32 ms max.
30 ms max.
T3
100 ms min.
250 ms min.
45 ms max.
Legend: T1, Pressure measurement time
T2, Response time
T3, Electrical discharge time
D8M-R1
Response time to 90% of 0.2kPa
Max. 3 seconds (excluding time for pressure change)
Application Examples
Compact D8M solid state pressure sensors provide reliable detection
for gas and air inflow for burner controls in water heaters, furnaces
and other gas-fired devices. They can also be used in
gas usage meters.
Solid State Pressure Sensors D8M
3
Dimensions
Unit: mm (inch)
■ D8M-A1
17.7 (0.70)
30 (1.18)
23 (0.92) ±0.2
10.1 (0.40)
5 (0.20)
2 (0.08)
1.6 (0.06)
4.4 (0.17)
4 (0.16) OD
Two 3.2 (0.13) dia.
mounting holes
30 (1.18)
18.8 (0.74)
18.6 (0.73)
23 (0.92) ±0.2
LOT NUMBER
TYPE NAME
11.6 (0.46)
2 (0.08)
7 (0.28)
Two, 1.5 (0.06) dia.
standoff pins
Three, 0.635 (0.025)
square terminal leads
4 (0.16) OD
Two, 3 (0.12) dia.
Mounting Holes
(Top View)
Terminal Arrangement
(Top View)
GND
VOUT
VCC
10.7 (0.42)
15.6 (0.61) ±0.01
23 (0.91) ±0.1
Two, M3 holes
5.08 (0.20)
5.08 (0.20)
■ D8M-D1
4
Solid State Pressure Sensors D8M
23 (0.91) ±0.1
■ D8M-D2
■ D8M-D82
Solid State Pressure Sensors D8M
5
■ D8M-R1
17.7 (0.70)
30 (1.18)
10.1 (0.40)
23 (0.91)
5 (0.20)
2 (0.08)
2 (0.08)
30
(1.18)
Two, 3.2 (0.13) dia.
1.6 (0.06)
18.8 (0.74)
2 (0.08) dia.
18.6 (0.73)
4 (0.16) OD
23
(0.91)
11.6
(0.46)
7 (0.28)
LOT NUMBER
TYPE NAME
5 (0.20) dia.
CONNECTOR
VCC (Pin 1)
FOUT (Pin 2)
GND (Pin 3)
Precautions
Be sure to abide by the following precautions for the safe operation of
the Sensor.
■ Soldering
Solder D8M-A1 on PC boards within 5 seconds using a soldering
iron whose tip temperature is adjusted to 345° to 355°C.
■ Mounting
For proper operation, mount the sensor within ±10 degrees of level.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4
OMRON ELECTRONICS LLC
OMRON CANADA,
ON-LINE INC.
OMRON
One East
Commerce
Commerce
DriveDrive
Schaumburg, IL 60173
885- http://www.omron.com
Milner Avenue
885
Milner
Avenue
Global
- http://www.omron.com
Global
Ontario M1B 5V8
Toronto,
Ontario M1B 5V8
USA - http://www.omron.com/oei
USAToronto,
- http://www.omron.com/oei
Canada - http://www.omron.com/oci Canada
- http://www.omron.ca
416-286-6465
416-286-6465
847-882-2288
1-800-55-OMRON
Cat. No.
T026-E3-1
CS01WAD1
Cat.
No. CS01WAD1(A)
6
OMRON
CANADA, INC.
OMRON
ON-LINE
10/02
07/02/7.5M
Specifications
Specifications
subject
subject
to to
change
to change
without
without
notice
notice
11/02
Specifications
subject
change
without
notice
Solid State Pressure Sensors D8M
Printed
Printed in
in USA
USA
Similar pages