HITRON HVI41-21 Universal input ac-dc pcb open frame single & multi-output 40-50 watts internal switching power supply Datasheet

H HiTRON
UNIVERSAL INPUT AC-DC PCB OPEN FRAME SINGLE &
MULTI-OUTPUT 40-50 WATTS INTERNAL SWITCHING
POWER SUPPLIES HVI41 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
SMALL & COMPACT IN SIZE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB. 22 & FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Range typ. 90-264Vac.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ. 40 watts with convection or
50 watts with 20 cfm fan cooling.
Output Connector: Molex V-M.
Line Regulation: Typ. 0.1%.
Load Regulation: Main VO1 typ.± 2.0%.
Aux. VO2 typ. ± 5.0%(stacked on).
VO3 typ. ± 3.0%(P.R.).
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Built-in at main VO1 (Latch).
Adjustability: Available at main VO1.
Overload Protection (OLP): Fully protected against output
overload and short circuit.
Consult the factory for OLP setting.
Rating 100 to 240Vac.
Input Connector: Molex V-M.
Input Frequency: 47-63Hz.
Inrush Current: Typ. 25.0A @230Vac.
Input Current: Typ. 0.7-1.2A@115Vac.
0.3-0.4A@230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 & FCC Class B.
Hold-up Time: Typ. 18mS @115Vac, 90mS @230Vac.
Earth Leakage: Less than 0.3mA @230Vac.
GENERAL SPECIFICATION
Efficiency: Typ. 75-85%.
Switching Frequency: 60K Hz.
Circuit Topology: Fixed Frequency Flyback Circuit.
Transient Response: Output voltage returns in less than
3mS following a 25% load change.
Safety Standard: IEC 60950-1/UL 60950-1 Class I.
Operating Temperature: 0 to +50°C convection.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: Typ. 0.04% /°C
Cooling: Free air convection, or with 20 cfm fan cooling.
Construction: PCB open frame format.
Power Density: 3.36-3.79Watts / Cubic Inch.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
For the details of safety approval, please consult the factory.
-11-
OUTPUT VOLTAGE / CURRENT RATINGS CHART
DUAL OUTPUT
SINGLE OUTPUT
MODEL NO.
HVI41-10
HVI41-11
HVI41-12
HVI41-13
HVI41-14
HVI41-16
HVI41-19
MAIN VO1 @★
Typ.
Fan-C Volt.
8.00A
9.0A
5.0V
3.30A
4.0A
12.0V
2.60A
3.3A
15.0V
1.60A
2.0A
24.0V
1.28A
1.8A
30.0V
0.80A
1.0A
48.0V
8.00A
9.0A
3.3V
MODEL NO.
HVI41-20
HVI41-21
HVI41-22
HVI41-23
HVI41-24
HVI41-290
MAIN VO1 @★
Typ.
Fan-C
Volt.
6.0A
7.0A
5.0V
4.0A
4.5A
5.0V
4.0A
4.5A
5.0V
4.0A
4.5A
5.0V
1.8A
2.0A
12.0V
5.0A
6.0A
3.3V
AUX. VO2 † or – VO3
Typ.
Fan-C
Volt.
2.0A
2.5A
5.0V
2.0A
2.5A
12.0V
1.5A
2.0A
15.0V
1.0A
1.5A
24.0V
1.8A
2.0A
12.0V
1.8A
2.0A
5.0V
TRIPLE OUTPUT
MODEL NO.
HVI41-30
HVI41-31
HVI41-32
HVI41-33
HVI41-33A
HVI41-390
HVI41-391
MAIN VO1 @★
Typ.
Fan-C Volt.
4.0A
4.5A
+5.0V
4.0A
4.5A
+5.0V
4.0A
4.5A
+5.0V
4.0A
4.5A
+5.0V
1.0A
1.5A
+5.0V
4.0A
4.5A
+3.3V
4.0A
4.5A
+3.3V
Symbol: " " OVP built-in.
"@" Adjustable.
Typ.
2.0A
2.0A
0.5A
1.6A
0.5A
1.8A
1.8A
AUX. VO2 †
Fan-C
Volt.
3.0A
+12V
3.0A
+12V
1.0A
+24V
2.0A
+15V
0.8A
+15V
2.0A
+5V
2.0A
+5V
"†" Stacked on main O/P.
Typ.
0.2A
0.2A
0.2A
0.2A
0.5A
0.2A
0.2A
AUX. VO3
Fan-C
0.5A
0.5A
0.5A
0.5A
0.8A
0.5A
0.5A
Volt.
-12V
-5V
-12V
-15V
-15V
-12V
-5V
" " Installed with Post Regulator (P.R.).
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 169.0g (5.96 Oz.)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
AC INPUT
ACACFASTON
LINE NEUTRAL
P1- 2
AC-GROUND
CONNECTOR & PIN # P1- 1
Mating connector: Molex 5195 or 5239 series.
ASSIGNMENT
SINGLE OUTPUT
DUAL OUTPUT
VO1
DC COM
VO1
P2-1,2,3
P2-4,5,6
P2-2,3
-12-
TRIIPLE OUTPUT
VO2 DC COM VO1
VO2
VO3
P2-1
P2-1
P2-6
P2-4,5,6 P2-2,3
DC
COM
P2-4,5