16-Channel Current Input Module
NI 9208
16 current inputs (±21.5 mA)
-40 to 70 °C
High-resolution mode with 50/60 Hz rejection
60 VDC, CAT I bank isolation (1,000 Vrms withstand)
500 S/s sample rate (high-speed mode)
Optional NI 9933 connectivity kit shown in image on right
Voltage supply pins for external power routing (2 A/30 V maximum)
24-bit resolution
Overview
The NI 9208 current input C Series module has 16 channels of ±21 mA input with built-in 50/60 Hz rejection for noise rejection.
Designed with industrial systems in mind, the NI 9208 has a high-channel density to reduce the number of modules you need. This opens slots for other measurement types and
reduces the overall cost per channel of the system.
The NI 9208 has a standard 37-pin D-Sub connection for use with available cables and connector blocks, or the NI 9937 D-Sub connector kit. The NI 9937 contains a D-Sub to
screw terminal accessory as well as a protective shell. With this kit, you can create a custom cable that plugs directly into the module, eliminating the need for a separate terminal
block.
Back to Top
Requirements and Compatibility
OS Information
Driver Information
Real-Time OS
Software Compatibility
NI-RIO
LabVIEW
LabVIEW FPGA Module
LabVIEW Real-Time Module
Back to Top
Comparison Tables
Module
Channels
Sample Rate
Simultaneous
Isolation
NI 9208
16 current
500 S/s
No
Channel-ground
NI 9207
8 current/8 voltage
500 S/s
No
Channel-ground
NI 9219
4 universal
100 S/s/ch
Yes
Channel-channel
NI 9203
8 current
200 kS/s
No
Channel-ground
Back to Top
1/7
www.ni.com
Application and Technology
Reduce Noise with 50/60 Hz Rejection/Filtering
The NI 9208, which was designed to work in noisy environments, has built-in 50/60 Hz rejection. This style of filter attenuates the most common noise in an industrial environment
that is caused by lighting, motors, and power lines.
Channel Density for High-Channel-Count Systems
Process and control applications can require a large number of sensor inputs. With the NI 9208, you can connect up to 16 pressure, load, torque, or other transducers to a single
module. Install multiple modules in a single system for up to 128 channels of 4 to 20 mA inputs.
Voltage Supply Pins for Easier Wire Routing
The NI 9208 has multiple voltage supply (Vsup) pins so you can wire a single power supply into the module and then route the power to the individual sensors through the module
I/O pins. The NI 9208 can support up to 2 A of current and up to 30 VDC.
Industrial Ratings for Rugged and Reliable Operation
C Series modules have industrial certifications and ratings for operation in harsh environments. Modules are rated for a -40 to 70 °C (-40 to 158 °F) temperature range, 50 g
shock, and hazardous locations or potentially explosive environments (Class I, Division 2). The NI 9208 features 60 VDC, CAT I isolation and up to 1,000 Vrms transient
withstand. Each module comes with a variety of international safety, electromagnetic compatibility (EMC), and environmental certifications and ratings. For more specific
information on the industrial certifications and other specifications, refer to the operating instructions manual.
Note: Not all C Series systems conform to the maximum specifications of the individual modules. Consult the specifications section of the manual for the specific chassis or carrier
to determine the maximum operational environment.
C Series Compatibility
The C Series hardware family features more than 50 measurement modules and several chassis and carriers for deployment. With this variety of modules, you can mix and match
measurements such as temperature, acceleration, flow, pressure, strain, acoustic, voltage, current, digital, and more to create a custom system. Install the modules in one of
several carriers to create a single-module USB, Ethernet, or Wi-Fi system or combine them in chassis such as NI CompactDAQ and CompactRIO to create a mixed-measurement
system with synchronized measurements. You can install up to eight modules in a simple, complete NI CompactDAQ USB data acquisition system to synchronize all of the analog
output, analog input, and digital I/O from the modules. For a system without a PC, CompactRIO holds up to eight modules and features a built-in processor, RAM, and storage for
an embedded data logger or control unit. For higher-speed control, CompactRIO chassis incorporate a field-programmable gate array (FPGA) that you can program with NI
LabVIEW software to achieve silicon-speed processing on I/O data from C Series modules. See the C Series Compatibility Chart for information on supported modules and
carriers.
Back to Top
Ordering Information
For a complete list of accessories, visit the product page on ni.com.
Products
Part
Number
Recommended
Accessories
779103-01
No accessories required.
780968-01
No accessories required.
37-pin D-Sub to screw terminal connector block with horizontal DIN-rail mount
7798673-01
No accessories required.
37-pin D-Sub to screw terminal connector block with vertical DIN-rail mount
778672-01
No accessories required.
NI CB-37F-LP unshielded I/O connector block
779353-01
No accessories required.
778621-01
No accessories required.
Part
Number
D-Sub Connector Kit
NI 9933 - Creates custom cable for modules with 37 pin D-Sub using D-Sub to screw terminal
connections
NI 9208 Module
NI 9208
D-Sub Terminal Blocks
D-Sub Cables for Use with 37-Pin D-Sub Modules
37-Pin D-Sub (M-F) Shielded Cable
Back to Top
Support and Services
System Assurance Programs
NI system assurance programs are designed to make it even easier for you to own an NI system. These programs include configuration and deployment services for your NI PXI,
CompactRIO, or Compact FieldPoint system. The NI Basic System Assurance Program provides a simple integration test and ensures that your system is delivered completely
assembled in one box. When you configure your system with the NI Standard System Assurance Program, you can select from available NI system driver sets and application
development environments to create customized, reorderable software configurations. Your system arrives fully assembled and tested in one box with your software preinstalled.
When you order your system with the standard program, you also receive system-specific documentation including a bill of materials, an integration test report, a recommended
maintenance plan, and frequently asked question documents. Finally, the standard program reduces the total cost of owning an NI system by providing three years of warranty
coverage and calibration service. Use the online product advisors at ni.com/advisor to find a system assurance program to meet your needs.
Calibration
2/7
www.ni.com
NI measurement hardware is calibrated to ensure measurement accuracy and verify that the device meets its published specifications. To ensure the ongoing accuracy of your
measurement hardware, NI offers basic or detailed recalibration service that provides ongoing ISO 9001 audit compliance and confidence in your measurements. To learn more
about NI calibration services or to locate a qualified service center near you, contact your local sales office or visit ni.com/calibration.
Technical Support
Get answers to your technical questions using the following National Instruments resources.
Support - Visit ni.com/support to access the NI KnowledgeBase, example programs, and tutorials or to contact our applications engineers who are located in NI sales
offices around the world and speak the local language.
Discussion Forums - Visit forums.ni.com for a diverse set of discussion boards on topics you care about.
Online Community - Visit community.ni.com to find, contribute, or collaborate on customer-contributed technical content with users like you.
Repair
While you may never need your hardware repaired, NI understands that unexpected events may lead to necessary repairs. NI offers repair services performed by highly trained
technicians who quickly return your device with the guarantee that it will perform to factory specifications. For more information, visit ni.com/repair.
Training and Certifications
The NI training and certification program delivers the fastest, most certain route to increased proficiency and productivity using NI software and hardware. Training builds the skills
to more efficiently develop robust, maintainable applications, while certification validates your knowledge and ability.
Classroom training in cities worldwide - the most comprehensive hands-on training taught by engineers.
On-site training at your facility - an excellent option to train multiple employees at the same time.
Online instructor-led training - lower-cost, remote training if classroom or on-site courses are not possible.
Course kits - lowest-cost, self-paced training that you can use as reference guides.
Training memberships and training credits - to buy now and schedule training later.
Visit ni.com/training for more information.
Extended Warranty
NI offers options for extending the standard product warranty to meet the life-cycle requirements of your project. In addition, because NI understands that your requirements may
change, the extended warranty is flexible in length and easily renewed. For more information, visit ni.com/warranty.
OEM
NI offers design-in consulting and product integration assistance if you need NI products for OEM applications. For information about special pricing and services for OEM
customers, visit ni.com/oem.
Alliance
Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than
700 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance.
Back to Top
Detailed Specifications
The following specifications are typical for the range – 40 to 70 °C unless otherwise noted. All voltages are relative to COM unless otherwise noted.
Input Characteristics
16 analog input channels
Number of channels
24 bits
ADC resolution
Delta-Sigma
Type of ADC
Scanned
Sampling mode
Input range
Minimum
±21.5 mA
Typical
±22 mA
Conversion time (per channel)
52 ms
High-resolution mode
2 ms
High-speed mode
±30 V max on one channel at a time
Overvoltage protection, channel-to-COM
Vsup pins
Current
2 A max
Voltage
30 V max
85 Ω
Input impedance
3/7
www.ni.com
Accuracy
Measurement Conditions Percent of Reading (Gain Error) Percent of Range 1 (Offset Error)
Calibrated error, max
0.76%
0.04%
(– 40 to 70 °C)
Input noise
High-resolution mode
50 nArms
High-speed mode
200 nArms
Stability
20 ppm/°C
Gain drift
62 nA/°C
Offset drift
NMRR (High-resolution mode only)
66 dB
50 Hz
68 dB
60 Hz
Contact NI for Bellcore MTBF or MIL-HDBK-217F specifications.
MTBF
Power Requirements
Power consumption from chassis
282 mW max
Active mode
25 μW max
Sleep mode
Thermal dissipation (at 70 °C)
1.29 W max
Active mode
0.72 W max
Sleep mode
Physical Characteristics
If you need to clean the module, wipe it with a dry towel.
Note For two-dimensional drawings and three-dimensional models of the C Series module and connectors, visit ni.com/dimensions and search by module number.
144 g (5.1 oz)
Weight
Safety
Safety Voltages
Connect only voltages that are within the following limits.
±30 V max
Channel-to-COM
Isolation
None
Channel-to-channel
Channel-to-earth ground
60 VDC, Measurement Category I
Continuous
1,000 Vrms, verified by a 5 s dielectric withstand test
Withstand
Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a
hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage
measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
Caution Do not connect the NI 9208 to signals or use for measurements within Measurement Categories II, III, or IV.
Hazardous Locations
Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx nA IIC T4
U.S. (UL)
Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, Ex nA IIC T4
Canada (C-UL)
Ex nA IIC T4
Europe (DEMKO)
Safety Standards
This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use:
4/7
www.ni.com
IEC 61010-1, EN 61010-1
UL 61010-1, CSA 61010-1
Note For UL and other safety certifications, refer to the product label or the Online Product Certification section.
Electromagnetic Compatibility
This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use:
EN 61326 (IEC 61326): Class A emissions; Industrial immunity
EN 55011 (CISPR 11): Group 1, Class A emissions
AS/NZS CISPR 11: Group 1, Class A emissions
FCC 47 CFR Part 15B: Class A emissions
ICES-001: Class A emissions
Note For EMC compliance, operate this device with double-shielded cables.
CE Compliance
This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows:
2006/95/EC; Low-Voltage Directive (safety)
2004/108/EC; Electromagnetic Compatibility Directive (EMC)
Note For the standards applied to assess the EMC of this product, refer to the Online Product Certification section.
Online Product Certification
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit
ni.com/certification, search by module number or product line, and click the appropriate link in the Certification column.
Shock and Vibration
To meet these specifications, you must panel mount the system.
Operating vibration
Random (IEC 60068-2-64)
5 grms, 10 to 500 Hz
Sinusoidal (IEC 60068-2-6)
5 g, 10 to 500 Hz
30 g, 11 ms half sine, 50 g, 3 ms half sine, 18 shocks at 6 orientations
Operating shock (IEC 60068-2-27)
Environmental
National Instruments C Series modules are intended for indoor use only but may be used outdoors if installed in a suitable enclosure. Refer to the manual for the chassis you are
using for more information about meeting these specifications.
– 40 to 70 °C
Operating temperature (IEC 60068-2-1, IEC 60068-2-2)
Storage temperature (IEC 60068-2-1, IEC 60068-2-2)
– 40 to 85 °C
Ingress protection
IP 40
10 to 90% RH, noncondensing
Operating humidity (IEC 60068-2-56)
Storage humidity (IEC 60068-2-56)
5 to 95% RH, noncondensing
Maximum altitude
2,000 m
2
Pollution Degree
Environmental Management
National Instruments is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous
substances from our products is beneficial not only to the environment but also to NI customers.
For additional environmental information, refer to the NI and the Environment Web page at ni.com/environment. This page contains the environmental regulations and directives
with which NI complies, as well as other environmental information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National
Instruments WEEE initiatives, visit ni.com/environment/weee.htm.
Calibration (Analog Input)
You can obtain the calibration certificate and information about calibration services for this device at ni.com/calibration.
2 years
5/7
www.ni.com
Calibration interval
1
Range equals 22 mA.
Back to Top
6/7
www.ni.com
Pinouts/Front Panel Connections
NI 9208 Pin Assignments
Back to Top
©2009 National Instruments. All rights reserved. CompactRIO, CVI, FieldPoint, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, and NI CompactDAQ are
trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has
no agency, partnership, or joint-venture relationship with National Instruments.
My Profile | RSS | Privacy | Legal | Contact NI © 2012 National Instruments Corporation. All rights reserved.
7/7
www.ni.com
Similar pages