Fujikura FPN-02PGR Sensing element/gauge dual-in-line package (dip) Datasheet

FPN Data sheet
Sensing element/Gauge
■Features
Dual-in-line package (DIP)
■Ordering Information
FPN-07P
G R
Terminal leadsdirection
Model
Rated Pressure
(PSI)
Pressure type
G:Gauge Pressure
No Mark:
R :
Weight
(grams)
RoHS compliance
1.1
Measurable pressure
range(kPa)
-13.79 to 13.79
FPN-02PG
FPN-02PGR
-34.47 to 34.47
FPN-05PG
FPN-05PGR
-48.26 to 48.26
FPN-07PG
FPN-07PGR
Part number
■Specifications
Model
02PG
05PG
07PG
Recommended operating conditions
Pressure type
Gauge pressure
Rated pressure
13.79
34.47
48.26
Measurable pressure range
-13.79 to 13.79
-34.47 to 34.47
-48.26 to 48.26
Temperature range
0 to 50
Pressure media
Non-corrosive gases only (No liquid)
Excitation current (Constant)
1.5
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
Maximum excitation current
3.0
Operating temperature
0 to 80
Storage temperature
-20 to 100
Operating humidity
30 to 80 (Non dew condition)
Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25deg.C)
Output span voltage
40 to 130 (at 0kPa to rated pressure)
Offset voltage
+/-25 (at 0kPa)
Bridge resistance
4000 to 6000
Response time
2 (for the reference)
Accuracy
TSO*
+/-10
+/-8
TCS*
5.0
2.5
Linearity
+/-0.6
+/-0.3
Pressure hysteresis
+/-1.0
+/-0.7
*TSO : Temperature sensitivity of offset voltage(Temperature range from 0-50 deg.C)
*TCS : Temperature coefficient of output span voltage(Temperature range from 0-50 deg.C)
1
Unit
kPa
kPa
deg.C
mADC
mADC
deg.C
deg.C
%RH
mV
mV
Ω
msec.
%FS/0-50deg.C
%FS/0-50deg.C
%FS
%FS
FPN Data sheet
Sensing element/Gauge
P1= 0 kPa
P2= 1/2 x P3 (kPa)
P3= reted pressure (kPa)
T1= 0 deg.C
T2= 25 deg.C
T3= 50 deg.C
Offset voltage (mV)
Voff = V(P1,T)
Voff(0) = V(P1,T1)
Voff(25) = V(P1,T2)
Voff(50) = V(P1,T3)
Output voltage at full scale (mV)
Vfs = V(P3,T)
Vfs(0) = V(P3,T1)
Vfs(25) = V(P3,T2)
Vfs(50) = V(P3,T3)
Output span voltage (mV)
SV = Vfs - Voff
SV(0) = Vfs(0) - Voff(0)
SV(25) = Vfs(25) - Voff(25)
SV(50) = Vfs(50) - Voff(50)
Temperature sensitivity of offset voltage (%FS)
TSO = {LARGER ONE} / SV(25) x 100
LARGER ONE = larger absolute value which of {Voff(0)-Voff(25)} and {Voff(50)-Voff(25)}
Temperature coefficient of output span voltage (%FS)
TCS = {max[SV(0),SV(25),SV(50)] - min[SV(0),SV(25),SV(50)] } / SV(25) x 100
Linearity (%FS)
NL = {V(P2,T2) - [Voff(25)+Vfs(25)]/2 } / SV(25) x 100
Pressure hysteresis (%FS)
Phys = {Voff’(25) - Voff(25) } / SV(25) x 100
Voff’(25) : Output voltage against P1 after stressing by P3 pressure.
2
FPN Data sheet
Sensing element/Gauge
■Outline dimensions■
3
FPN Data sheet
Sensing element/Gauge
■Connection diagram■
■Output characteristics■
↑Output voltage(mV)
Output span voltage
Offset voltage
-Rated pressure
0kPa
Atomospheric
pressure
Note ;
Rated pressure
→Pressure(kPa)
Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
Please keep the sensors sealed using static shielding bags on storage.The pins of the sensor are plated by Ag.
If the sensors expose to an atmosphere, the pins will be black by sulfuration.
Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress
such as mounting, installation and etc. over longtime using.
If you have any questions regarding technical issues or specifications, please contact us.
Fujikura Ltd. Sensor Department
5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072
E-mail : [email protected]