Cynergy3 FCNM Fluid level switch Datasheet

FCNM Series
Fluid Level switches
cynergycomponents
The switch is based on a simple principle of a float located inside an enclosed
chamber, which follows the level of the liquid in the system. When the liquid level
rises, the float magnet attracts and operates a 20A 250Vac microswitch with N/O and
N/C contacts.
Suitable for use in water or liquids of SG equal to or greater than 1.
SPECIFICATION
Material:
Housing : Brass
Float : Polypropylene
250Vac
20A
8 bar
Fluid input 1/4" BSP/GAS
Air vent 3-4mm flexible
0/55°C +32/+131°F
14mm
32mm
Switching voltage max.
Switching current max. resistive
Max working pressure
Pipe connections:
Temperature Range
Must Close Level (S.G.=1)
Must Open Level (S.G.=1)
• Level control in pipes
• Prevention of Dry-
running of centrifugal
pumps
• Level control in tanks
• Level control in
pressurised
containers
(autoclaves)
must close
220
level
must open
1 2
3
electric cable
level
cable retainer
cable - entry
1/4 BSP
56
60
ISO 9001C E R T I F IED
Cynergy3 Components Ltd
7 Cobham Road
Ferndown Industrial Estate
Wimborne
Dorset BH21 7PE
Tel: +44 (0) 1202 897969
[email protected]
www.cynergy3.com
© 2013 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
FCNM 2013
FCNM Series
Fluid Level switches
cynergycomponents
INSTALLATION
FCNMRP type applications - solution suitable both for pressurised tubing and for deprepressurised pipes and systems
horizontal pipe
level control
suction control for
peripheral pumps
supplied from below
vertical pipe control
water
air
1/4"
autoclaves water / air
level control
spanner
adjustable
pipe wrench
important for tightening
suction control for peripheral
pumps supplied from above
FCNMAS type applications - solution suitable only for pressurised tubing
automatic air vent valve
must be installed vertically
it operates with cap loosened
by one turn
vertical pipe control
suction control for peripheral
pumps supplied from above
horizontal pipe
level control
ISO 9001C E R T I F IED
www.cynergy3.com
© 2013 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
Similar pages