ANADIGICS AMT8310T46L 2.5 gb/s 850 nm pin-tia Datasheet

AMT8310
2.5 Gb/s 850 nm PIN-TIA
PRELIMINARY DATA SHEET - Rev 1.0
FEATURES
•
•
•
•
•
•
•
2.5 Gb/s Differential Output TIA
3.3 V Operation
1800 MHz Bandwidth
-23 dBm Typical Sensitivity
0 dBm Optical Overload
100 µm 850 nm PIN Photodetector
Ambient Temperature Range: -40 to +85 °C
APPLICATIONS
•
•
•
•
SONET OC-48/SDH STM-16 (2.488 Gb/s)
2 x Fibre Channel (2.125 Gb/s)
2.5 Gb/s Infiniband
Fibre Channel/Gigabit Ethernet (1.0625/1.25 Gb/s)
T46L
TO-46 Ball
Lens Package
PRODUCT DESCRIPTION
The ANADIGICS AMT8310, packaged in a 4 pin
TO-46 lens can, is a 3.3 V integrated photodetector
and transimpedance amplifier (TIA) used to convert
a short wavelength (850 nm) input optical signal into
a differential output voltage. The AMT8310 has a
bandwidth of 1.8 GHz, a dynamic range of over
23 dB and a sensitivity of -23 dBm. These devices
are readily designed into receivers, transceivers
and transponders for SONET, Fibre Channel and
Infiniband applications.
VCC
2
RF
1
PIN
3
DC Compensation
Low
Pass
Filter
Offset
Control
4
Figure 1: Functional Block Diagram
09/2003
VOUTN
VOUTP
AMT8310
Figure 2 : T46L Pin Outline (Bottom View)
Table 1: TO-46 Package Pin Description
PIN
NAME
DESCRIPTION
1
VOUTN
Inverted Output Voltage. Logical '0' with an optical input. Needs to be AC
coupled to the load.
2
VC C
Positive Supply Voltage: 3.0 to 3.6 V
3
VOUTP
Non-Inverted Output Voltage: Logical '1' with an optical input. Needs to be
AC coupled to the load.
4
Ground
Ground: Case is grounded.
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Maximum Ratings
PARAMETER
Supply Voltage
Optical Input Power
Storage Temperature
MIN
MAX
UNIT
-0.5
6.0
V
-
+4
dB m
- 40
+ 125
°C
Stresses in excess of the absolute ratings may cause permanent
damage. Functional operation is not implied under these conditions.
Exposure to absolute ratings for extended periods of time may
adversely affect reliability.
2
PRELIMINARY DATA SHEET - Rev 1.0
09/2003
AMT8310
Table 3: Electrical Specifications
PARAMETER
MIN
TYP
MAX
UNIT
850
-
nm
-
100
-
µm
Small Signal Differential
Responsivity (@ 100 MHz) (1)
10000
15000
-
V/W
Bandwidth (1)
1500
1800
-
MHz
Low Frequency Cutoff
-
30
-
kHz
Output Resistance
-
50
-
Ω
Optical Overload (2)
0
-
dB m
Optical Sensitivity (2)
-21
-23
-
dB m
Maximum Differential Output Voltage
-
550
700
mV
TRISE and TFALL (20-80%) (3)
-
140
-
ps
Duty Cycle Distortion (4)
-
5
-
%
Wavelength (λ)
Detector Diameter
Total Jitter (4), (5)
60
Supply Current
ps
-
40
60
mA
Operating Voltage Range
+3.0
+3.3
+3.6
Volts
Operating Case Temperature
-30
-
+105
°C
Notes:
(1) Measured at -20 dBm optical input power with output connected into RL = 100Ω (differential)
(2) Measured at 10-10 BER with a 223-1 PRBS at 2.5 Gb/s
(3) Measured with a 223-1 PRBS at 2.5 Gb/s, an input optical power of –20 dBm
and RL = 100Ω (differential)
(4) Measured with a 223-1 PRBS at 2.5 Gb/s, an input optical power of –3 dBm and RL = 100Ω (differential)
(5) 6 σ about the center eye crossing.
PRELIMINARY DATA SHEET - Rev 1.0
09/2003
3
AMT8310
PERFORMANCE DATA
100 ps/Div.
50 mV/Div.
Figure 3: Eye Diagram with an Optical Input Power of –20 dBm
100 ps/Div.
90 mV/Div.
Figure 4: Eye Diagram with an Optical Input Power of –15 dBm
100 ps/Div.
90 mV/Div.
Figure 5: Eye Diagram with an Optical Input Power of –10 dBm
4
PRELIMINARY DATA SHEET - Rev 1.0
09/2003
AMT8310
600.0
500.0
400.0
300.0
200.0
100.0
0.0
0.00
0.20
0.40
0.60
0.80
1.00
1.20
1.40
1.60
Input Power (mWpp)
Figure 6: Differential Output Voltage vs. Input Power
PRELIMINARY DATA SHEET - Rev 1.0
09/2003
5
AMT8310
Figure 7: T46L Package Outline Diagram
6
PRELIMINARY DATA SHEET - Rev 1.0
09/2003
AMT8310
NOTES
PRELIMINARY DATA SHEET - Rev 1.0
09/2003
7
AMT8310
ORDERING INFORMATION
ORDER NUMBER
PACKAGE
OPTION
PACKAGE DESRIPTION
AMT8310T46L
TO-46L
Lens Package
ANADIGICS, Inc.
141 Mount Bethel Road
Warren, New Jersey 07059, U.S.A.
Tel: +1 (908) 668-5000
Fax: +1 (908) 668-5132
URL: http://www.anadigics.com
E-mail: [email protected]
IMPORTANT NOTICE
ANADIGICS, Inc. reserves the right to make changes to its products or to discontinue any product at any time without notice. The
product specifications contained in Advanced Product Information sheets and Preliminary Data Sheets are subject to change
prior to a product’s formal introduction. Information in Data Sheets have been carefully checked and are assumed to be reliable;
however, ANADIGICS assumes no responsibilities for inaccuracies. ANADIGICS strongly urges customers to verify that the
information they are using is current before placing orders.
WARNING
ANADIGICS products are not intended for use in life support appliances, devices or systems. Use of an ANADIGICS product in
any such application without written consent is prohibited.
8
PRELIMINARY DATA SHEET - Rev 1.0
09/2003