Ramtron FM24C64 64kb fram serial memory Datasheet

FM24C64
64Kb FRAM Serial Memory
Features
64K bit Ferroelectric Nonvolatile RAM
• Organized as 8,192 x 8 bits
• High Endurance 1 Trillion (1012) Read/Writes
• 45 Year Data Retention
• NoDelay™ Writes
• Advanced High-Reliability Ferroelectric Process
Fast Two-wire Serial Interface
• Up to 1 MHz maximum bus frequency
• Direct hardware replacement for EEPROM
• Supports legacy timing for 100 kHz & 400 kHz
Description
The FM24C64 is a 64-kilobit nonvolatile memory
employing an advanced ferroelectric process. A
ferroelectric random access memory or FRAM is
nonvolatile and performs reads and writes like a
RAM. It provides reliable data retention for 45 years
while eliminating the complexities, overhead, and
system level reliability problems caused by
EEPROM and other nonvolatile memories.
Low Power Operation
• 5V operation
• 150 µA Active Current (100 kHz)
• 10 µA Standby Current
Industry Standard Configuration
• Industrial Temperature -40° C to +85° C
• 8-pin SOIC (-S)
• “Green” 8-pin SOIC (-G)
Pin Configuration
A0
A1
A2
1
8
2
7
3
6
VSS
4
5
VDD
WP
SCL
SDA
The FM24C64 performs write operations at bus
speed. No write delays are incurred. Data is written to
the memory array in the cycle after it has been
successfully transferred to the device. The next bus
cycle may commence immediately. The FM24C64 is
capable of supporting 1012 read/write cycles, or a
million times more write cycles than EEPROM.
These capabilities make the FM24C64 ideal for
nonvolatile memory applications requiring frequent
or rapid writes. Examples range from data collection
where the number of write cycles may be critical, to
demanding industrial controls where the long write
time of EEPROM can cause data loss. The
combination of features allows more frequent data
writes with less overhead for the system.
The FM24C64 provides substantial benefits to users
of serial EEPROM, yet these benefits are available in
a hardware drop-in replacement. The FM24C64 is
available in an industry standard 8-pin SOIC package
using a two-wire protocol. The specifications are
guaranteed over an industrial temperature range of
-40°C to +85°C.
This product conforms to specifications per the terms of the Ramtron
standard warranty. The product has completed Ramtron’s internal
qualification testing and has reached production status.
Rev. 3.0
Mar. 2005
Pin Names
A0-A2
SDA
SCL
WP
VSS
VDD
Function
Device Select Address
Serial Data/address
Serial Clock
Write Protect
Ground
Supply Voltage 5V
Ordering Information
FM24C64-S
FM24C64-G
8-pin SOIC
“Green” 8-pin SOIC
Ramtron International Corporation
1850 Ramtron Drive, Colorado Springs, CO 80921
(800) 545-FRAM, (719) 481-7000
www.ramtron.com
1 of 12
FM24C64
Address
Latch
Counter
1,024 x 64
FRAM Array
8
SDA
Serial to Parallel
Converter
Data Latch
SCL
WP
Control Logic
A0-A2
Figure 1. FM24C64 Block Diagram
Pin Description
Pin Name
A0-A2
I/O
Input
SDA
I/O
SCL
Input
WP
Input
VDD
VSS
Rev. 3.0
Mar. 2005
Supply
Supply
Pin Description
Address 2-0: These pins are used to select one of up to 8 devices of the same type on
the same two-wire bus. To select the device, the address value on the three pins must
match the corresponding bits contained in the device address.
Serial Data Address: This is a bi-directional pin used to shift serial data and addresses
for the two-wire interface. It employs an open-drain output and is intended to be wireOR’d with other devices on the two-wire bus. The input buffer incorporates a Schmitt
trigger for noise immunity and the output driver includes slope control for falling
edges. A pull-up resistor is required.
Serial Clock: The serial clock input for the two-wire interface. Data is clocked out of
the device on the SCL falling edge, and clocked in on the SCL rising edge. The SCL
input also incorporates a Schmitt trigger input for improved noise immunity.
Write Protect: When WP is high, addresses in the upper quadrant of the logical
memory map will be write-protected. Write access is permitted to the lower threequarters of the address space. When WP is low, all addresses may be written. This pin
must not be left floating.
Supply Voltage: 5V
Ground
2 of 12
FM24C64
Overview
Two-wire Interface
The FM24C64 is a serial FRAM memory. The
memory array is logically organized as a 8,192 x 8 bit
memory array and is accessed using an industry
standard two-wire interface. Functional operation of
the FRAM is similar to serial EEPROMs. The major
difference between the FM24C64 and a serial
EEPROM with the same pinout relates to its superior
write performance.
The FM24C64 employs a bi-directional two-wire bus
protocol using few pins and little board space. Figure
2 illustrates a typical system configuration using the
FM24C64 in a microcontroller-based system. The
industry standard two-wire bus is familiar to many
users but is described in this section.
Memory Architecture
When accessing the FM24C64, the user addresses
8,192 locations each with 8 data bits. These data bits
are shifted serially. The 8,192 addresses are accessed
using the two-wire protocol, which includes a slave
address (to distinguish from other non-memory
devices), and an extended 16-bit address. Only the
lower 13 bits are used by the decoder for accessing
the memory. The upper three address bits should be
set to 0 for compatibility with larger devices in the
future.
The memory is read or written at the speed of the
two-wire bus. Unlike an EEPROM, it is not
necessary to poll the device for a ready condition
since writes occur at bus speed. That is, by the time a
new bus transaction can be shifted into the part, a
write operation is complete. This is explained in more
detail in the interface section below.
Users can expect several obvious system benefits
from the FM24C64 due to its fast write cycle and
high endurance as compared with EEPROM.
However there are less obvious benefits as well. For
example in a high noise environment, the fast-write
operation is less susceptible to corruption than an
EEPROM since it is completed quickly. By contrast,
an EEPROM requiring milliseconds to write is
vulnerable to noise during much of the cycle.
By convention, any device that is sending data onto
the bus is the transmitter while the target device for
this data is the receiver. The device that is controlling
the bus is the master. The master is responsible for
generating the clock signal for all operations. Any
device on the bus that is being controlled is a slave.
The FM24C64 always is a slave device.
The bus protocol is controlled by transition states in
the SDA and SCL signals. There are four conditions:
Start, Stop, Data bit, and Acknowledge. Figure 3
illustrates the signal conditions that specify the four
states. Detailed timing diagrams are shown in the
Electrical Specifications section.
VDD
Rmin = 1.8 KΩ
Rmax = tR/Cbus
Microcontroller
SDA
SCL
SDA
SCL
FM24C64
FM24C64
A0 A1 A2
A0 A1 A2
Figure 2. Typical System Configuration
Note that the FM24C64 contains no power
management circuits other than a simple internal
power-on reset. It is the user’s responsibility to
ensure that VDD is within datasheet tolerances to
prevent incorrect operation.
Rev. 3.0
Mar. 2005
3 of 12
FM24C64
Figure 3. Data Transfer Protocol
Stop Condition
A Stop condition is indicated when the bus master
drives SDA from low to high while the SCL signal is
high. All operations must end with a Stop condition.
If an operation is pending when a stop is asserted, the
operation will be aborted. The master must have
control of SDA (not a memory read) in order to assert
a Stop condition.
Start Condition
A Start condition is indicated when the bus master
drives SDA from high to low while the SCL signal is
high. All read and write transactions begin with a
Start condition. An operation in progress can be
aborted by asserting a Start condition at any time.
Aborting an operation using the Start condition will
ready the FM24C64 for a new operation.
If during operation the power supply drops below the
specified VDD minimum, the system should issue a
Start condition prior to performing another operation
Data/Address Transfer
All data transfers (including addresses) take place
while the SCL signal is high. Except under the two
conditions described above, the SDA signal should
not change while SCL is high.
Acknowledge
The Acknowledge takes place after the 8th data bit
has been transferred in any transaction. During this
state the transmitter should release the SDA bus to
allow the receiver to drive it. The receiver drives the
SDA signal low to acknowledge receipt of the byte.
If the receiver does not drive SDA low, the condition
is a No-Acknowledge and the operation is aborted.
Rev. 3.0
Mar. 2005
The receiver could fail to acknowledge for two
distinct reasons. First, if a byte transfer fails, the NoAcknowledge ends the current operation so that the
device can be addressed again. This allows the last
byte to be recovered in the event of a
communication error. Second and most common,
the receiver does not acknowledge the data to
deliberately end an operation. For example, during a
read operation, the FM24C64 will continue to place
data onto the bus as long as the receiver sends
acknowledges (and clocks). When a read operation
is complete and no more data is needed, the receiver
must not acknowledge the last byte. If the receiver
acknowledges the last byte, this will cause the
FM24C64 to attempt to drive the bus on the next
clock while the master is sending a new command
such as a Stop command.
Slave Address
The first byte that the FM24C64 expects after a start
condition is the slave address. As shown in Figure 4,
the slave address contains the Slave ID (device
type), the device select address bits, and a bit that
specifies if the transaction is a read or a write. Bits
7-4 define the device type and must be set to 1010b
for the FM24C64. These bits allow other types of
function types to reside on the 2-wire bus within an
identical address range. Bits 3-1 are the select bits
which are equivalent to chip select bits. They must
match the corresponding value on the external
address pins to select the device. Up to eight
FM24C64s can reside on the same two-wire bus by
assigning a different address to each. Bit 0 is the
read/write bit. A 1 indicates a read operation, and a
0 indicates a write.
4 of 12
FM24C64
Memory Operation
Device
Select
Slave
ID
1
0
1
0
A2
A1 A0 R/W
7
6
5
4
3
2
1
0
Figure 4. Slave Address
Addressing Overview
After the FM24C64 (as receiver) acknowledges the
device address, the master can place the memory
address on the bus for a write operation. The address
requires two bytes. The first is the MSB (upper byte).
Since the device uses only 13 address bits, the value
of the upper three bits are don’t care. Following the
MSB is the LSB (lower byte) with the remaining
eight address bits. The address value is latched
internally. Each access causes the latched address
value to be incremented automatically. The current
address is the value that is held in the latch, either a
newly written value or the address following the last
access. The current address will be held as long as
power remains or until a new value is written. Reads
always use the current address. A random read
address can be loaded by beginning a write operation
as explained below.
After transmission of each data byte and just prior to
the acknowledge, the FM24C64 increments the
internal address latch. This allows the next sequential
byte to be accessed with no additional addressing
externally. After the last address (1FFFh) is reached,
the address latch will roll over to 0000h. There is no
limit to the number of bytes that can be accessed with
a single read or write operation.
Data Transfer
After the address information has been transmitted,
data transfer between the bus master and the
FM24C64 can begin. For a read operation, the
FM24C64 will place 8 data bits on the bus then wait
for an Acknowledge from the master. If the
Acknowledge occurs, the FM24C64 will transfer the
next sequential byte. If the Acknowledge is not sent,
the FM24C64 will end the read operation. For a write
operation, the FM24C64 will accept 8 data bits from
the master and then send an Acknowledge. All data
transfer occurs MSB (most significant bit) first.
Rev. 3.0
Mar. 2005
The FM24C64 is designed to operate in a manner
very similar to other 2-wire interface memory
products. The major differences result from the
higher performance write capability of FRAM
technology. These improvements result in some
differences between the FM24C64 and a similar
configuration EEPROM during writes. The
complete operation for both writes and reads is
explained below.
Write Operation
All writes begin with a device address, then a
memory address. The bus master indicates a write
operation by setting the LSB of the device address
to a 0. After addressing, the bus master sends each
byte of data to the memory and the memory
generates an acknowledge condition. Any number of
sequential bytes may be written. If the end of the
address range is reached internally, the address
counter will wrap from 1FFFh to 0000h.
Unlike other nonvolatile memory technologies,
there is no write delay with FRAM. The entire
memory cycle occurs in less time than a single bus
clock. Therefore, any operation including a read or
write can occur immediately following a write.
Acknowledge polling, a technique used with
EEPROMs to determine if a write is complete is
unnecessary and will always return a ready
condition.
Internally, the actual memory write occurs after the
8th data bit is transferred. It will be complete before
the Acknowledge is sent. Therefore, if the user
desires to abort a write without altering the memory
contents, this should be done using a Start or Stop
condition prior to the 8th data bit. The FM24C64
uses no page buffering.
Portions of the memory array can be write protected
using the WP pin. Pulling the WP pin high (VDD)
will write-protect addresses in the upper quadrant
from 1800h to 1FFFh. The FM24C64 will not
acknowledge data bytes that are written to protected
addresses. In addition, the address counter will not
increment if writes are attempted to these addresses.
Pulling WP low (VSS) will deactivate this feature.
WP should not be left floating.
Figures 5 and 6 illustrate both a single-byte write
and multiple-byte write.
5 of 12
FM24C64
Address and Data
By Master Start
DEVICE ADDRESS
0 A X X X
S
Stop
ADDRESS LSB
ADDRESS MSB
A
DATA BYTE
A
A P
By FM24C64
ACKNOWLEDGE
Figure 5. Byte Write
Address and Data
By Master Start
S
DEVICE ADDRESS
ADDRESS LSB
ADDRESS MSB
0 A X X X
A
DATA BYTE
DATA BYTE
A
A
Stop
A P
By FM24C64
ACKNOWLEDGE
Figure 6. Multiple Byte Write
Read Operation
There are two basic types of read operations. They
are current address read and selective address read. In
a current address read, the FM24C64 uses the internal
address latch to supply the address. In a selective
read, the user performs a procedure to set the address
to a specific value.
Current Address & Sequential Read
The FM24C64 uses an internal latch to supply the
address for a read operation. A current address read
uses the existing value in the address latch as a
starting place for the read operation. The system
reads from the address immediately following that of
the last operation.
To perform a current address read, the bus master
supplies a device address with the LSB set to 1. This
indicates that a read operation is requested. After
receiving the complete device address, the FM24C64
will begin shifting out data from the current address
on the next clock. The current address is the value
held in the internal address latch. Beginning with the
current address, the bus master can read any number
of bytes. Thus, a sequential read is simply a current
address read with multiple byte transfers. After each
byte the internal address counter will be incremented.
Each time the bus master acknowledges a byte, this
indicates that the FM24C64 should read out the next
sequential byte.
There are four ways to properly terminate a read
operation. Failing to properly terminate the read will
likely create a bus contention as the FM24C64
Rev. 3.0
Mar. 2005
attempts to read out additional data onto the bus. The
four valid methods are:
1.
2.
3.
4.
The bus master issues a no-acknowledge in the
9th clock cycle and a stop in the 10th clock cycle.
This is illustrated in Figures 7-9. This is the
preferred method.
The bus master issues a no-acknowledge in the
9th clock cycle and a start in the 10th.
The bus master issues a stop in the 9th clock
cycle.
The bus master issues a start in the 9th clock
cycle.
If the internal address reaches 1FFFh, it will wrap
around to 0000h on the next read cycle. Figures 7 and
8 show the proper operation for current address reads.
Selective (Random) Read
There is a simple technique that allows a user to
select a random address location as the starting point
for a read operation. This involves using the first
three bytes of a write operation to set the internal
address followed by subsequent read operations.
To perform a selective read, the bus master sends out
the device address with the LSB set to 0. This
specifies a write operation. According to the write
protocol, the bus master then sends the address bytes
that are loaded into the internal address latch. After
the FM24C64 acknowledges the address, the bus
master issues a start condition. This simultaneously
aborts the write operation and allows the read
command to be issued with the device address LSB
set to a 1. The operation is now a current address
read.
6 of 12
FM24C64
Address
By Master Start
DEVICE ADDRESS
No Acknowledge
Stop
DATA BYTE
1 A
S
1 P
By FM24C64
Acknowledge
Data
Figure 7. Current Address Read
Address
By Master Start
DEVICE ADDRESS
Acknowledge
DATA BYTE
1 A
S
No Acknowledge
Stop
DATA BYTE
A
DATA BYTE
A
1 P
By FM24C64
Acknowledge
Data
Figure 8. Sequential Read
Address
By Master
Start
DEVICE ADDRESS
S
ADDRESS MSB
0 A X X X
ADDRESS LSB
A
Acknowledge
Start
DEVICE ADDRESS
A S
DATA BYTE
1 A
No Acknowledge
Stop
DATA BYTE
A
1 P
By FM24C64
Acknowledge
Data
Figure 9. Selective (Random) Read
Endurance
Internally, a FRAM operates with a read and restore
mechanism. Therefore, endurance cycles are applied
for each read or write cycle. The FRAM architecture
is based on an array of rows which are subdivided
into segments. Rows (defined by A12-A5) are
subdivided into 4 segments (A4-A3). Each access
causes an endurance cycle for a row segment. In the
FM24C64, there are 8 bytes (defined by A2-A0) per
Rev. 3.0
Mar. 2005
segment. Endurance can be optimized by ensuring
frequently accessed data is located in different
segments. Regardless, FRAM read and write
endurance is effectively unlimited at the 1MHz twowire speed. Even at 3000 accesses per second to the
same segment, 10 years time will elapse before 1
trillion endurance cycles occur.
7 of 12
FM24C64
Electrical Specifications
Absolute Maximum Ratings
Symbol
Description
VDD
Power Supply Voltage with respect to VSS
VIN
Voltage on any signal pin with respect to VSS
TSTG
TLEAD
VESD
Storage temperature
Lead temperature (Soldering, 10 seconds)
Electrostatic Discharge Voltage
- Human Body Model (JEDEC Std JESD22-A114-B)
- Machine Model (JEDEC Std JESD22-A115-A)
Package Moisture Sensitivity Level
Ratings
-1.0V to +7.0V
-1.0V to +7.0V
and VIN < VDD+1.0V *
-55°C to + 125°C
300° C
4kV
250V
MSL-1
* Exception: The “VIN < VDD+1.0V” restriction does not apply to the SCL and SDA inputs.
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating
only, and the functional operation of the device at these or any other conditions above those listed in the operational section of
this specification is not implied. Exposure to absolute maximum ratings conditions for extended periods may affect device
reliability.
DC Operating Conditions (TA = -40° C to + 85° C, VDD = 4.5V to 5.5V unless otherwise specified)
Symbol
Parameter
Min
Typ
Max
Units
VDD
Main Power Supply
4.5
5.0
5.5
V
IDD
VDD Supply Current
@ SCL = 100 kHz
115
150
µA
@ SCL = 400 kHz
400
500
µA
@ SCL = 1 MHz
1
1.2
mA
ISB
Standby Current
1
10
µA
ILI
Input Leakage Current
±1
µA
ILO
Output Leakage Current
±1
µA
VIL
Input Low Voltage
-0.3
0.3 VDD
V
VIH
Input High Voltage
0.7 VDD
VDD + 0.5
V
VOL
Output Low Voltage
0.4
V
@ IOL = 3 mA
VHYS
Input Hysteresis
0.05 VDD
V
Notes
1
2
3
3
4
Notes
1. SCL toggling between VDD-0.3V and VSS, other inputs VSS or VDD-0.3V
2. SCL = SDA = VDD. All inputs VSS or VDD. Stop command issued.
3. VIN or VOUT = VSS to VDD.
4. This parameter is characterized but not tested.
Rev. 3.0
Mar. 2005
8 of 12
FM24C64
AC Parameters (TA = -40° C to + 85° C, VDD = 4.5V to 5.5V, CL = 100 pF unless otherwise specified)
Min
Max
Min
Max
Min
Max
Symbol Parameter
fSCL
SCL Clock Frequency
0
100
0
400
0
1000
tLOW
Clock Low Period
4.7
1.3
0.6
tHIGH
Clock High Period
4.0
0.6
0.4
tAA
SCL Low to SDA Data Out Valid
3
0.9
0.55
tBUF
tHD:STA
tSU:STA
tHD:DAT
tSU:DAT
tR
tF
tSU:STO
tDH
tSP
Bus Free Before New
Transmission
Start Condition Hold Time
Start Condition Setup for Repeated
Start
Data In Hold
Data In Setup
Input Rise Time
Input Fall Time
Stop Condition Setup
Data Output Hold
(from SCL @ VIL)
Noise Suppression Time Constant
on SCL, SDA
Units
kHz
µs
µs
µs
4.7
1.3
0.5
µs
4.0
4.7
0.6
0.6
0.25
0.25
µs
µs
0
250
0
100
0
100
300
100
ns
ns
ns
ns
µs
ns
50
ns
1000
300
4.0
0
300
300
0.6
0
50
0.25
0
50
Notes
1
1
Notes : All SCL specifications as well as start and stop conditions apply to both read and write operations.
1 This parameter is periodically sampled and not 100% tested.
Capacitance (TA = 25° C, f=1.0 MHz, VDD = 5V)
Symbol
Parameter
CI/O
Input/Output Capacitance (SDA)
CIN
Input Capacitance
Max
8
6
Units
pF
pF
Notes
1
1
Notes
1 This parameter is periodically sampled and not 100% tested.
Rev. 3.0
Mar. 2005
9 of 12
FM24C64
AC Test Conditions
Equivalent AC Load Circuit
Input Pulse Levels
Input rise and fall times
Input and output timing levels
5.5V
0.1 VDD to 0.9 VDD
10 ns
0.5 VDD
1700 Ω
Diagram Notes
All start and stop timing parameters apply to both read and write
cycles. Clock specifications are identical for read and write cycles.
Write timing parameters apply to slave address, word address, and
write data bits. Functional relationships are illustrated in the relevant
data sheet sections. These diagrams illustrate the timing parameters
only.
Output
100 pF
Read Bus Timing
tLOW
tF
tR
tSP
tSP
tHIGH
SCL
1/fSCL
tSU:STA
tSU:DAT
tBUF
SDA
tAA
Start
Stop
Start
Data bit 7
from FM24C64
tHD:DAT
Valid
Valid
tDH
Data bit 6
from FM24C64
Data bits
5-0 from FM24C64
Acknowledge
to FM24C64
Write Bus Timing
tHD:STA
tHD:DAT
SCL
tSU:DAT
tSU:STO
SDA
Valid
Start
Stop
Start
Data/Address bit 7
to FM24C64
Data Retention (VDD = 4.5V to 5.5V, +85° C)
Parameter
Data Retention
Rev. 3.0
Mar. 2005
Min
45
tAA
Valid
Data/Address bit 6
to FM24C64
Units
Years
Data/Address bit 5-0
to FM24C64
Acknowledge
from FM24C64
Notes
10 of 12
FM24C64
Mechanical Drawing
8-pin SOIC (JEDEC Standard MS-012 variation AA)
Recommended PCB Footprint
7.70
3.90 ±0.10
3.70
6.00 ±0.20
2.00
0.65
1.27
Pin 1
4.90 ±0.10
1.27
0.33
0.51
0.25
0.50
1.35
1.75
0.10
0.25
0.10 mm
0°- 8°
0.19
0.25
45°
0.40
1.27
Refer to JEDEC MS-012 for complete dimensions and notes.
All dimensions in millimeters.
SOIC Package Marking Scheme
XXXXXXX-P
LLLLLLL
RICYYWW
Legend:
XXXX= part number, P= package type
LLLLLLL= lot code
RIC=Ramtron Int’l Corp, YY=year, WW=work week
Example: FM24C64, Standard SOIC package, Year 2004, Work Week 39
FM24C64-S
A40003S
RIC0439
Rev. 3.0
Mar. 2005
11 of 12
FM24C64
Revision History
Revision
0.1
1.0
1.1
2.1
Date
10/4/99
12/7/99
7/2/00
1/22/02
2.2
4/26/02
2.3
2.4
3.0
8/5/03
3/17/04
3/29/05
Rev. 3.0
Mar. 2005
Summary
Initial Release
Changed to Preliminary status.
Removed Endurance chart.
Changed to Production status. Added clarification to package standard and
changed package name to SOIC.
Changed endurance from 1010 to 1012 cycles. Rewrote Data Retention and
Endurance section. Changed storage temp range -55 to +125 C. Removed
Data Retention note.
Removed DIP package option.
Added “green” package. Updated package drawing.
Changed Data Retention spec. Added ESD and package MSL ratings. New
rev. number to comply with new scheme.
12 of 12