Series 3 Liquid Level Switches ASME B31.1, ASME B31.3 and NACE Construction D E S C R I P T I O N Series 3 float-actuated level switches meet ASME B31.1 or ASME B31.3 requirements. They are designed to provide critical alarm set points in clean liquid applications. F E A T U R E S • NACE MR0175/MR0103 construction available for flanged cage models • 14-inch (356 mm) side/side process connections available as standard • Choice of sealed or flanged float chamber design • Service pressures up to 1680 psig (115.8 bar) for ASME B31.1 and 2240 psig (154.4 bar) for ASME B31.3 & NACE • Process temperatures up to +1000° F (+538° C) • Specific gravity ratings as low as 0.33 • Choice of TYPE 4X/7/9, Group B, C & D or EEx d IIC T6 housings • Agency approvals include FM, CSA, ATEX and SAA B35 Sealed Cage Level Switch • ASME B31.1, B31.3 or NACE Certificate of Conformance supplied B3F Flanged Cage Level Switch • ASME B31.1 model with Cr-Mo chamber • Choice of available switch styles, including dry contact, hermetically sealed, pneumatic bleed and non-bleed • Choice of single or multiple switches for single or staged applications A P P L I C A T I O N S ASME B31.1 construction for use on boilers and in power plants. • Feedwater heaters • Steam drums • Condensate drip pots • Flash tanks • Deaerators • Hot wells • 1", 11⁄2" or 2" tank connections available in either NPT, socket weld, flanged side/side or flanged side/bottom configuration • Special materials of construction available upon request ASME B31.3 construction for use in refineries and petrochemical plants. • Available with special coatings including Epoxy, Carbo Zinc® 11 Primer and Carboline Top Coat, Dimetcote® and Amercoat® • Optional high or low temperature insulation available • Gas/oil separators • Receivers • Knockout drums • Flare pots • Crude/salt water separators • Accumulators O P T I O N S Many options are available for Series 3 level switches. Should you require an option not listed, consult the factory for further information. TANK CONNECTIONS AND INSTALLATION DIMENSIONS ENCLOSING TUBE In addition to the standard slip-on or weld neck R.F. flanges, many other process, vent and drain connections are available, including: design available for flanged cage models. • Socketweld • DIN • RTJ • JIS Special flange gasket surface finishes are also available, and cages may be manufactured to allow special process connections. Integrally welded (socket type weld) enclosing tube INTERFACE CALIBRATION Units with interface calibration are custom designed for each application. Specific gravity differences as small as 0.10 may be addressed. Consult the factory for all interface calibrations. EXAMINATIONS/TESTS MATERIALS OF CONSTRUCTION Chambers and internal components on some models available in other metal alloys. • 304 SS • 316 SS • Hastelloy® C • Monel • Carpenter 20® • Duplex Stainless Steel Magnetrol is equipped to provide a full range of special quality control testing, including: • Dye penetration • Radiography • Charpy • Magnetic particle • Extended hydrostatic • Ultrasonic • Hardness testing WELDING Stress relieving of chamber welds is available for flanged cage models and the model B35-7. ACTUATING LEVELS • Special switch set points and/or differentials • Tandem floats—where the switch actuating levels are 8 inches (203 mm) or more apart. • Multiple switches 2 CHROME-MOLY CONSTRUCTION The model B35 is available with a P22/F22 chromemoly chamber and 321 SS float for high pressure applications at high temperatures. S T A N D A R D A S M E B31.1 CONSTRUCTION S T A N D A R D A S M E B31.3 CONSTRUCTION PRODUCT DESIGN PRODUCT DESIGN Pressure vessels are designed within code specified stress limits. Design calculations, design prints and weld qualifications are available for audit. All chamber branch and circumferential weld joints are designed to achieve FULL penetration. Pressure vessels are designed within code specified stress limits. Design calculations, design prints and weld qualifications are available for audit. All chamber branch and circumferential weld joints are designed to achieve FULL penetration. WELDING WELDING All welding is performed by qualified welders and per procedures required by the ASME Boiler Pressure Vessel Code Sec. IX. Welds are visually inspected for FULL penetration. All other nondestructive examination is performed per ASME B31.1. All welding is performed by qualified welders and per procedures required by the ASME Boiler Pressure Vessel Code Sec. IX. Welds are visually inspected for FULL penetration; and 5% radiographic inspection of weld is performed per ASME B31.3. MATERIALS OF CONSTRUCTION MATERIALS OF CONSTRUCTION All pressure-retaining materials are procured with Certificates of Conformance to assure compliance of components with required standards. Chrome-Moly models are post-weld heat-treated. All pressure-retaining materials are procured with Certificates of Conformance to assure compliance of components with required standards. HYDROSTATIC TEST HYDROSTATIC TEST All chambers are hydrostatically tested at 1.5 times the design pressure. S T A N D A R D N A C E All chambers are hydrostatically tested at 1.5 times the design pressure. C O N S T R U C T I O N WELDING All welding is performed by qualified welders and per procedures required by the ASME Boiler Pressure Vessel Code Sec. IX. Carbon steel pressure boundary parts are post weld stress relieved. All welds and heat affected zones are hardness tested to ensure compliance with NACE maximum hardness requirements. MATERIALS OF CONSTRUCTION Only NACE listed materials are used for pressure retaining parts. Certificates of Conformance assure compliance of components to required material standards. HYDROSTATIC TEST All chambers are hydrostatically tested at 1.5 times the design pressure. 3 T E C H N O L O G Y A permanent magnet is attached to a pivoted switch actuator . As the float or displacer rises with the liquid level, it raises the attraction sleeve into the field of the magnet, which then snaps against the non-magnetic enclosing tube , actuating the switch . The enclosing tube provides a static pressure boundary between the switch mechanism and the process. On a falling level, an inconel spring retracts the magnet, deactuating the switch. A G E N C Y 2 5 Pivot 6 4 Return Spring 1 3 Process Liquid Process Liquid Rising Level Falling Level A P P R O V A L S AGENCY MODEL APPROVED APPROVAL CLASSES FM All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 Class I, Div 1, Groups C & D Class II, Div 1, Groups E, F & G All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 Class I, Div 1, Group B Class I, Div 1, Groups B, C & D Class II, Div 1, Groups E, F & G All with a Series HS, H1, F, 8 or 9 electric switch mechanism and a housing listed as CSA TYPE 4X Class I, Div 2, Groups B, C & D All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 Class I, Div 1, Groups C & D Class II, Div 1, Groups E, F & G All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 Class I, Div 1, Group B Class I, Div 1, Groups B, C & D Class II, Div 1, Groups E, F & G All with an electric switch mechanism and an ATEX housing ATEX II 2 G EEx d IIC T6 94/9/EC IEC Ex Ex d IIC T6 IP 66 All models Installation Category II Pollution Degree 2 CSA ATEX / IEC Ex CE Low Voltage Directives 2006/95/EC per Harmonized Standard EN 61010-1/1993 & Amendment No. 1 Controls with two or more HS or H1 switches are not ATEX approved. IEC Installation Instructions: The cable entry and closing devices shall be Ex d certified suitable for the conditions of use and correctly installed. For ambient temperatures above +55° C or for process temperatures above +150° C, suitable heat resistant cables shall be used. Heat extensions (between process connection and housing) shall never be insulated. Special conditions for safe use: When the equipment is installed in process temperatures higher than +85° C the temperature classification must be reduced according to the following table as per IEC60079-0. 4 Maximum Process Temperature Temperature Classification < 85° C T6 < 100° C T5 < 135° C T4 < 200° C T3 < 300° C T2 < 450° C T1 These units are in conformity with IECEx KEM 05.0020X Classification Ex d IIC T6 Tambient -40° C to +70° C S P E C I F I C A T I O N S S W I T C H M E C H A N I S M S A N D E N C L O S U R E S SERIES B, C, D & R DRY CONTACT SWITCHES SERIES F, HS, H1, 8 & 9 HERMETICALLY SEALED SWITCHES • Designs for AC and DC current applications • Ideal for use in salt and other corrosive atmospheres • Process temperatures to +1000° F (+538° C) • Entire switch mechanism and contacts are contained within a positively pressurized capsule with Series “HS” and “H1” • Process temperatures to +1000° F (+538° C) SERIES J & K PNEUMATIC SWITCHES SWITCH ENCLOSURES • Suited for applications where electrical power is not available • TYPE 4X/7/9 aluminum enclosures • Designed to meet Class I, Div. 1, Groups C & D and Class I, Div. 1 Group B • Bleed and non-bleed designs • Process temperatures to +400° F (+204° C) • Cast iron TYPE 4X/7/9 enclosures for hazardous areas greater than +750° F (+399° C) • Optional housing heaters and drains available for some enclosures • Pneumatic switch mechanisms available with a NEMA 1 enclosure BASIC ELECTRICAL RATINGS Voltage 120 VAC 240 VAC 24 VDC 120 VDC 240 VDC Switch Series and Non-Inductive Ampere Rating D F HS H1 R 8 B C 15.00 15.00 15.00 10.00 1.00 0.50 15.00 6.00 0.50 0.25 10.00 — 10.00 10.00 3.00 2.50 — 4.00 0.30 — 5.00 5.00 5.00 0.50 0.25 1.00 1.00 1.00 0.40 — 1.00 1.00 1.00 0.40 — 1.00 — 3.00 — — 9 — — 0.50 — — 5 A S M E B 3 1 . 1 A C T U A T I N G L E V E L S NOTE: Actuation levels for saturate steam service ratings are shown for single switch units with 1" process connections only. Consult factory for units with two and three set point and 11⁄2" or 2" process connections. For float operated units, levels are dependent upon the specific gravity of the process media. SATURATED STEAM SERVICE RATINGS (See model selection charts for maximum ratings) ASME B31.1 SEALED CAGE MODELS WITH 1" PROCESS CONNECTIONS INCHES MILLIMETERS Sealed Cage Pressure Temperature Specific (psig) (° F) Gravity Models B35 812 520 0.76 C35 379 443 0.83 G35 546 476 0.80 V35 1044 550 0.74 Z35 1113 558 0.73 Sealed Cage Pressure Temperature Specific (bar) (° C) Gravity Models B35 56 271 0.76 C35 26 227 0.83 G35 38 247 0.80 V35 72 288 0.74 Z35 77 292 0.73 Actuation Levels HL LL 3.33 4.05 4.33 3.19 3.39 3.91 4.57 4.77 3.81 3.97 Levels ± 0.25" (6 mm) Actuation Levels HL LL 85 103 110 81 86 99 116 121 97 101 Levels ± 0.25" (6 mm) ASME B31.1 FLANGED CAGE MODELS W/1" PROCESS CONNECTIONS – INCHES Flanged Cage Models B3F G3F K3F Z3F Head Flange Lbs. 150 300 600 150 300 600 600 600 900 Pressure (psig) Temperature (° F) Specific Gravity 201 601 819 201 601 819 1123 1132 1564 388 489 523 388 481 523 559 560 602 0.87 0.79 0.76 0.87 0.79 0.76 0.73 0.73 0.68 Actuation Levels HL LL 3.32 2.82 2.67 5.32 4.62 4.29 4.21 3.50 3.18 4.13 3.53 3.57 5.75 5.06 5.00 4.65 4.09 3.84 Levels ± 0.25" (6 mm) ASME B31.1 FLANGED CAGE MODELS W/1" PROCESS CONNECTIONS – MILLIMETERS Flanged Cage Models B3F G3F K3F Z3F Head Flange Lbs. 150 300 600 150 300 600 600 600 900 Pressure (bar) Temperature (° C) Specific Gravity 14 41 56 14 41 56 77 78 108 199 254 271 199 249 271 293 293 317 0.87 0.79 0.76 0.87 0.79 0.76 0.73 0.73 0.68 Actuation Levels HL LL 84 72 68 135 117 109 107 89 81 105 90 91 146 129 127 118 104 98 Levels ± 0.25" (6 mm) A S M E B 3 1 . 3 D I S P L A C E R M O D E L S DISPLACER MODELS WITH 1" PROCESS CONNECTIONS – INCHES Liquid Specific Gravity Model Code B34 C34 0.40 0.50 0.60 0.70 0.80 0.90 1.00 Process Temp. ° F HL LL HL LL HL LL HL LL HL LL HL LL HL LL 100 200 300 100 200 300 400 500 1.30 1.24 1.18 4.56 4.19 3.81 n/a n/a 4.77 4.70 4.62 8.44 8.06 7.63 n/a n/a 2.17 2.13 2.09 5.75 5.50 5.19 4.81 4.44 5.00 4.95 4.88 8.94 8.63 8.25 7.88 7.44 2.73 2.70 2.67 6.56 6.31 6.06 5.75 5.44 5.16 5.11 5.06 9.25 9.00 8.69 8.38 8.00 3.13 3.11 3.09 7.13 6.94 6.69 6.44 6.19 5.28 5.24 5.19 9.50 9.25 9.00 8.75 8.44 3.44 3.42 3.40 7.50 7.38 7.19 6.94 6.69 5.37 5.34 5.30 9.69 9.50 9.25 9.00 8.75 3.67 3.66 3.64 7.88 7.69 7.50 7.31 7.13 5.45 5.41 5.38 9.81 9.63 9.44 9.25 9.25 3.86 3.85 3.84 8.13 8.00 7.81 7.63 7.44 5.51 5.48 5.45 9.94 9.75 9.56 9.38 9.19 Levels ± 0.25" (6 mm) 6 A S M E B 3 1 . 3 A C T U A T I N G For float operated units, minimum specific gravity and actuating levels vary depending upon the material of construction code used with the unit. L E V E L S Minimum specific gravity and levels will change for multistage units and levels will change for units with 11⁄2" or 2" process connections. Consult factory for these changes. For displacer operated units, minimum specific gravity and actuating levels vary depending upon the temperature at which the unit is operated. The level decals on the control identify the actuation levels at the corresponding minimum specific gravity. NOTE: The minimum specific gravity and actuating levels shown are for single switch units with 1" process connections only. ASME B31.3 SEALED CAGE MODELS WITH 1" PROCESS CONNECTIONS INCHES MILLIMETERS Models w/Mat. of Const. Code 1 Actuating Level Min. @ Min. Sp. Gr. Sp. Gr. HL LL 0.69 3.06 3.62 0.57 3.15 3.86 0.55 3.25 3.83 0.40 3.56 4.06 0.41 3.31 3.98 0.71 3.06 3.81 0.66 2.94 3.63 Model Code B35 C35 G35 K35 L35 V35 Z35 Models w/Mat. of Const. Code 2 Actuating Level Min. @ Min. Sp. Gr. Sp. Gr. HL LL 0.72 3.06 3.79 0.59 3.09 3.96 0.56 3.20 3.90 0.40 3.40 4.02 0.43 3.34 4.14 0.75 3.00 3.64 0.68 2.90 3.47 Model Code B35 C35 G35 K35 L35 V35 Z35 Models w/Mat. of Const. Code 1 Actuating Level Min. @ Min. Sp. Gr. Sp. Gr. HL LL 0.69 78 92 0.57 80 98 0.55 82 97 0.40 90 103 0.41 84 101 0.71 78 97 0.66 75 92 Models w/Mat. of Const. Code 2 Actuating Level Min. @ Min. Sp. Gr. Sp. Gr. HL LL 0.72 78 96 0.59 78 101 0.56 81 99 0.40 86 102 0.43 85 105 0.75 76 92 0.68 74 88 Levels ± 0.25" (6 mm) Levels ± 0.25" (6 mm) ASME B31.3 FLANGED CAGE MODELS WITH 1" PROCESS CONNECTIONS INCHES MILLIMETERS Head Model Flg. Code Lbs. B3F G3F K3F Z3F 150 300 600 150 300 600 150 300 600 600 900 Models w/Mat. of Const. Models w/Mat. of Const. Code 1 Code 2 Actuating Level Min. Min. Actuating Level @ Min. Sp. Gr. @ Min. Sp. Gr. Sp. Sp. Gr. Gr. HL LL HL LL 0.78 3.00 3.87 0.83 2.97 4.05 0.66 2.17 2.97 0.68 2.10 3.10 0.66 2.06 3.12 0.71 2.19 2.94 0.41 3.58 4.26 0.43 3.61 4.42 0.55 3.52 4.10 0.56 3.47 4.18 0.70 4.00 4.81 0.76 4.13 4.75 0.33 3.08 3.64 0.33 2.97 3.65 0.40 3.05 3.56 0.40 2.96 3.57 0.60 3.30 3.85 0.62 3.44 3.88 0.67 3.10 3.80 0.70 3.12 3.68 0.67 3.10 3.80 0.70 3.12 3.68 Head Model Flg. Code Lbs. B3F G3F K3F Z3F 150 300 600 150 300 600 150 300 600 600 900 Models w/Mat. of Const. Models w/Mat. of Const. Code 1 Code 2 Min. Actuating Level Min. Actuating Level @ Min. Sp. Gr. @ Min. Sp. Gr. Sp. Sp. Gr. Gr. HL LL HL LL 0.78 76 98 0.83 75 103 0.66 55 75 0.68 53 79 0.66 52 79 0.71 56 75 0.41 91 108 0.43 92 112 0.55 89 104 0.56 88 106 0.70 102 122 0.76 105 121 0.33 78 92 0.33 75 93 0.40 77 90 0.40 75 91 0.60 84 98 0.62 87 99 0.67 79 97 0.70 79 93 0.67 79 97 0.70 79 93 Levels ± 0.25" (6 mm) A S M E B 3 1 . 3 Levels ± 0.25" (6 mm) D I S P L A C E R M O D E L S (Displacer Models cont. from page 6) DISPLACER MODELS WITH 1" PROCESS CONNECTIONS – MILLIMETERS Liquid Specific Gravity Model Code B34 C34 Process Temp. ° C 38 93 149 38 93 149 205 260 0.40 HL 33 31 30 116 106 97 n/a n/a 0.50 LL 121 119 117 214 205 194 n/a n/a HL 55 54 53 146 140 132 122 113 0.60 LL 127 126 124 227 219 210 200 189 HL 69 69 68 167 160 154 146 138 0.70 LL 131 130 129 235 229 221 213 203 HL 80 79 78 181 176 170 164 157 0.80 LL 134 133 132 241 235 229 222 214 HL 87 87 86 191 187 183 176 170 0.90 LL 136 136 135 246 241 235 229 222 HL 93 93 92 200 195 191 186 181 1.00 LL 138 137 137 249 245 240 235 229 HL 98 98 98 207 203 198 194 189 LL 140 139 138 252 248 243 238 233 Levels ± 0.25" (6 mm) 7 D I M E N S I O N A L I N C H E S S P E C I F I C A T I O N S ( m m ) L ASME B31.1 & B31.3 SEALED CAGE MODELS All housings rotatable 360°. M NEMA 1: 8.50 (216) TYPE 4X/7/9: 10.12 (257) Group B: 10.12 (257) Allow 8 inches (203 mm) overhead clearance for cover removal. K K Plugged Conduit Connections K Electrical Switches TYPE 4X/7/9: 1" NPT Group B: 1" NPT Pneumatic Switches 1 NEMA 1: ⁄4" NPT Outline Dimensions L M TYPE4X/7/9 TYPE4X/7/9 Group B 4.29 (108) 5.93 (151) NEMA 1 5.00 (127) 4.62 (117) HL (Ref) C LL A B Threaded and Socket Weld Upper Side/Bottom L M L K K Plugged M K K Plugged HL (Ref) J LL G HL (Ref) F LL D H Flanged Side/Side 8 E Flanged Upper Side/Bottom D I M E N S I O N A L S P E C I F I C A T I O N S SEALED CAGE MODELS — ASME B31.1 150# & 300# ANSI PRESSURE RATINGS ASME B31.3 ALL PRESSURE RATINGS CHAMBERS WITH 1- INCH CONNECTIONS INCHES MILLIMETERS 1" NPT Threaded Model & Socket Weld Code A B C B34 1" Flanged 1" Flanged Upper Side/Bottom Side/Side D F G J E H Std. 14" Std. 14" Std. 14" Std. 14" 8.76 3.63 13.84 12.87 — 6.38 17.95 — 13.62 — 6.38 18.70 — B35 8.92 4.15 15.12 11.56 14.00 6.69 17.76 20.20 12.21 14.00 6.69 18.41 20.20 227 105 384 294 356 170 451 513 310 356 170 468 513 C35 8.92 4.15 15.12 11.56 14.00 6.69 17.76 20.20 12.21 14.00 6.69 18.41 20.20 227 105 384 294 356 170 451 513 310 356 170 468 513 G35 9.80 4.69 16.17 12.31 14.00 7.19 18.68 20.36 12.96 14.00 7.19 19.33 20.36 249 119 410 313 356 183 474 517 329 356 183 490 517 L35 9.80 4.69 16.17 12.31 14.00 7.19 18.68 20.36 12.96 14.00 7.19 19.33 20.36 249 119 410 313 356 183 474 517 329 356 183 490 517 V35 8.92 4.15 15.12 11.56 14.00 6.68 17.76 20.20 12.21 14.00 6.68 18.41 20.20 227 105 384 294 356 170 451 513 310 356 170 468 513 Z35 9.80 4.69 16.17 12.31 14.00 7.19 18.68 20.36 12.96 14.00 7.19 19.33 20.36 249 119 411 313 356 183 475 517 329 356 183 491 517 D A B A 223 1" Flanged 1" Flanged Upper Side/Bottom Side/Side D F G J B C E H Std. 14" Std. 14" Std. 14" Std. 14" 92 352 327 — 162 459 — 346 — 162 478 — F C D E Std. 1" NPT Thread & Socket Weld 16" H Std. 16" Std. 16" A Std. B C 16" F G E Std. 16" J H Std. 16" Std. 16" Std. 16" K35 12.04 5.68 18.92 14.56 16.00 8.19 21.45 22.89 15.21 16.00 8.19 22.10 22.89 306 144 481 370 406 208 545 581 386 406 208 561 581 CHAMBERS WITH 112⁄ - INCH CONNECTIONS INCHES 1 ⁄2" NPT Threaded & Socket Weld 1 Model Code 1 ⁄2" Flanged Upper Side/Bottom D F E Std. 14" Std. 14" MILLIMETERS 1 ⁄2" Flanged Side/Side 1 11⁄2" NPT Thread & Socket Weld 1 B34 J Std. 14" Not Available B35 8.92 4.22 15.12 12.56 14.00 7.69 18.76 20.20 13.21 14.00 7.69 19.41 20.20 227 107 384 319 356 195 477 513 336 356 195 493 513 A B C G 11⁄2" Flanged 11⁄2" Flanged Upper Side/Bottom Side/Side D F G J E H Std. 14" Std. 14" Std. 14" Std. 14" Std. 14" H A B C C35 8.92 4.22 15.12 12.56 14.00 7.69 18.76 20.20 13.21 14.00 7.69 19.41 20.20 227 107 384 319 356 195 477 513 336 356 195 493 513 G35 9.80 4.75 16.17 13.31 14.00 8.19 19.68 20.36 13.96 14.00 8.19 20.33 20.36 249 121 411 338 356 208 500 517 355 356 208 516 517 L35 9.80 4.75 16.17 13.31 14.00 8.19 19.68 20.36 13.96 14.00 8.19 20.33 20.36 249 121 411 338 356 208 500 517 355 356 208 516 517 V35 8.92 4.22 15.12 12.56 14.00 7.69 18.76 20.20 13.21 14.00 7.69 19.41 20.20 227 107 384 319 356 195 477 513 336 356 195 493 513 Z35 9.80 4.75 16.17 13.31 14.00 8.19 19.68 20.36 13.96 14.00 8.19 20.33 20.36 249 121 411 338 356 208 500 513 355 356 208 517 517 D A B F C D E Std. 16" H Std. 16" Std. 16" A Std. B C 16" F G E Std. 16" J H Std. 16" Std. 16" Std. 16" K35 12.04 5.75 18.92 15.56 16.00 9.19 22.45 22.89 16.21 16.00 9.19 23.10 22.89 306 146 481 395 406 233 570 581 412 406 233 587 581 CHAMBERS WITH 2 - INCH CONNECTIONS INCHES Model Code 2" NPT Threaded & Socket Weld 2 " Flanged Upper Side/Bottom D F E Std. 14" Std. 14" MILLIMETERS 2" Flanged Side/Side 1 2" Flanged 2" Flanged Upper Side/Bottom Side/Side D F G J E H Std. 14" Std. 14" Std. 14" Std. 14" B34 J Std. 14" Not Available B35 8.92 4.34 15.12 12.56 14.00 7.69 18.76 20.20 13.21 14.00 7.69 19.41 20.20 227 110 384 319 356 195 477 513 336 356 195 493 513 A B C G 2" NPT Thread & Socket Weld Std. 14" H A B C C35 8.92 4.34 15.12 12.56 14.00 7.69 18.76 20.20 13.21 14.00 7.69 19.41 20.20 227 110 384 319 356 195 477 513 336 356 195 493 513 G35 9.80 4.88 16.17 13.31 14.00 8.19 19.68 20.36 13.96 14.00 8.19 20.33 20.36 249 124 411 338 356 208 500 517 355 356 208 516 517 L35 9.80 4.88 16.17 13.31 14.00 8.19 19.68 20.36 13.96 14.00 8.19 20.33 20.36 249 124 411 338 356 208 500 517 355 356 208 516 517 V35 8.92 4.34 15.12 12.56 14.00 7.69 18.76 20.20 13.21 14.00 7.69 19.41 20.20 227 110 384 319 356 195 477 513 336 356 195 493 513 Z35 9.80 4.88 16.17 13.31 14.00 8.19 19.68 20.36 13.96 14.00 8.19 20.33 20.36 249 124 411 338 356 208 500 513 355 356 208 517 517 D A B F C D E Std. 16" H Std. 16" Std. 16" A Std. 16" B C F G E Std. 16" J H Std. 16" Std. 16" Std. 16" K35 12.04 5.88 18.92 15.56 16.00 9.19 22.45 22.89 16.21 16.00 9.19 23.10 22.89 306 149 481 395 406 233 570 581 412 406 233 587 581 9 D I M E N S I O N A L I N C H E S S P E C I F I C A T I O N S ( mm ) L ASME B31.1 & B31.3 SEALED CAGE MODELS All housings rotatable 360°. M NEMA 1: 8.50 (216) TYPE 4X/7/9: 10.12 (257) Group B: 10.12 (257) Allow 8 inches (203 mm) overhead clearance for cover removal. K K Plugged Conduit Connections K Electrical Switches TYPE 4X/7/9: 1" NPT Group B: 1" NPT Pneumatic Switches 1 NEMA 1: ⁄4" NPT Outline Dimensions L M TYPE4X/7/9 TYPE4X/7/9 Group B 4.29 (108) 5.93 (151) NEMA 1 5.00 (127) 4.62 (117) HL (Ref) C LL A B Threaded and Socket Weld Upper Side/Bottom L M L K K Plugged M K K Plugged HL (Ref) J LL G HL (Ref) F LL D H Flanged Side/Side 10 E Flanged Upper Side/Bottom D I M E N S I O N A L S P E C I F I C A T I O N S ASME B31.1 SEALED CAGE MODELS — 600# & 900# ANSI PRESSURE RATINGS CHAMBERS WITH 1- INCH CONNECTIONS — 600 & 900 LB. ANSI CLASS INCHES MILLIMETERS 1" NPT Threaded & Socket Weld 1" Flanged Upper Side/Bottom Model Code D A B F C G 16" D H 14" 1" Flanged Upper Side/Bottom J E 14" 1" NPT Thread & Socket Weld 1" Flanged Side/Side 16" 14" 16" A 14" B C 16" F 1" Flanged Side/Side G J E 14" 16" H 14" 16" 14" 16" 14" 16" B35 8.92 4.15 15.12 14.00 — 9.00 20.20 — 14.00 — 9.00 20.20 — 227 105 384 356 — 229 513 — 356 — 229 513 — C35 8.92 4.15 15.12 14.00 — 9.00 20.20 — 14.00 — 9.00 20.20 — 227 105 384 356 — 229 513 — 356 — 229 513 — G35 9.80 4.69 16.17 22.36 — V35 8.92 4.15 15.12 14.00 — 14.00 Z35 9.80 4.69 16.17 22.36 — — 16.00 10.00 — — — 9.00 20.20 16.00 10.00 — 16.00 10.00 — — 22.36 249 119 410 — 406 254 — 568 — 406 254 — 568 9.00 20.20 16.00 10.00 — — 227 105 384 356 — 229 513 — 356 — 229 513 — 22.36 249 119 410 — 406 254 — 568 — 406 254 — 568 CHAMBERS WITH 112⁄ - INCH CONNECTIONS — 600 & 900 LB. ANSI CLASS INCHES MILLIMETERS 11⁄2" NPT Threaded & Socket Weld 11⁄2" Flanged Upper Side/Bottom Model Code D A B F C G 16" D H 14" 11⁄2" Flanged Upper Side/Bottom J E 14" 11⁄2" NPT Thread & Socket Weld 11⁄2" Flanged Side/Side 16" 14" 16" A 14" B C 16" F 11⁄2" Flanged Side/Side G J E 14" 16" H 14" 16" 14" 16" 14" 16" B35 8.92 4.22 15.12 14.00 — 9.00 20.20 — 14.00 — 9.00 20.20 — 227 107 384 356 — 229 513 — 356 — 229 513 — C35 8.92 4.22 15.12 14.00 — 9.00 20.20 — 14.00 — 9.00 20.20 — 227 107 384 356 — 229 513 — 356 — 229 513 — G35 9.80 4.75 16.17 22.36 — V35 8.92 4.22 15.12 14.00 — 14.00 Z35 9.80 4.75 16.17 22.36 — — 16.00 10.00 — — — 9.00 20.20 16.00 10.00 — 16.00 10.00 — — 22.36 249 121 410 — 406 254 — 568 — 406 254 — 568 9.00 20.20 16.00 10.00 — — 227 107 384 356 — 229 513 — 356 — 229 513 — 22.36 249 121 410 — 406 254 — 568 — 406 254 — 568 CHAMBERS WITH 2 - INCH CONNECTIONS — 600 & 900 LB. ANSI CLASS INCHES MILLIMETERS 2" NPT Threaded & Socket Weld 2" Flanged Upper Side/Bottom Model Code D A B F C G J E 14" 16" 2" NPT Thread & Socket Weld 2" Flanged Side/Side D H 14" 16" 14" 16" A 14" 2" Flanged Upper Side/Bottom 16" B C F 2" Flanged Side/Side G E 14" 16" J H 14" 16" 14" 16" 14" 16" B35 8.92 4.34 15.12 14.00 — 9.00 20.20 — 14.00 — 9.00 20.20 — 227 110 384 356 — 229 513 — 356 — 229 513 — C35 8.92 4.34 15.12 14.00 — 9.00 20.20 — 14.00 — 9.00 20.20 — 227 110 384 356 — 229 513 — 356 — 229 513 — G35 9.80 4.88 16.17 22.36 — V35 8.92 4.34 15.12 14.00 — 14.00 Z35 9.80 4.88 16.17 22.36 — — — 16.00 10.00 — — 10.00 20.20 16.00 10.00 — 16.00 10.00 — — 10.00 20.20 16.00 10.00 — 22.36 249 124 410 — 406 254 — 568 — 406 254 — 568 — 227 110 384 356 — 254 513 — 356 — 254 513 — 22.36 249 124 410 — 406 254 — 568 — 406 254 — 568 11 D I M E N S I O N A L I N C H E S S P E C I F I C A T I O N S ( m m ) M L ASME B31.1 & B31.3 FLANGED CAGE MODELS All housings rotatable 360°. NEMA 1: 8.50 (216) TYPE 4X/7/9: 10.12 (257) Group B: 10.12 (257) K Plugged Allow 8 inches (203 mm) overhead clearance for cover removal. K Conduit Connections K Electrical Switches TYPE 4X/7/9: 1" NPT Group B: 1" NPT Pneumatic Switches 1 NEMA 1: ⁄4" NPT HL LL (Ref) C Outline Dimensions L M TYPE4X/7/9 TYPE4X/7/9 Group B 3.87 (98) 5.93 (151) NEMA 1 5.00 (127) 4.62 (117) A B Threaded and Socket Weld Upper Side/Bottom L M L K Plugged M K K Plugged HL K K LL HL (Ref) J G (Ref) F LL D H Flanged Side/Side 12 E Flanged Upper Side/Bottom D I M E N S I O N A L S P E C I F I C A T I O N S FLANGED CAGE MODELS — ASME B31.1 150# & 300# ANSI PRESSURE RATINGS ASME B31.3 ALL PRESSURE RATINGS CHAMBERS WITH 1- INCH CONNECTIONS INCHES Head 1" NPT Threaded & Socket Weld Model Flg. Code rating B C (lbs.) A C34 B3F G3F Z3F K3F 300 600 150 300 600 150 300 600 600 900 15.63 15.63 9.12 9.12 9.12 10.12 10.12 10.12 10.11 10.11 3.13 3.13 3.63 3.63 3.63 4.69 4.69 4.69 4.68 4.68 22.59 22.72 16.64 17.32 18.45 18.30 19.12 20.56 20.19 21.13 A B C 150 11.62 5.69 20.38 300 11.62 5.69 21.25 600 11.62 5.69 22.93 1" Flanged Upper Side/Bottom D F E Std. 14" Std. 14" 18.33 — 5.45 25.29 — 18.33 — 5.45 25.42 — 12.06 14.00 6.13 19.58 21.51 12.06 14.00 6.13 20.26 22.19 12.06 14.00 6.13 21.39 23.32 13.06 14.00 7.19 21.25 22.19 13.06 14.00 7.19 22.06 23.00 13.06 14.00 7.19 23.50 24.44 13.06 14.00 7.19 23.14 24.08 13.06 14.00 7.19 23.14 25.37 D F E Std. 16" Std. 16" 14.56 16.00 8.19 23.33 24.77 14.56 16.00 8.19 24.20 25.64 14.56 16.00 8.19 25.88 27.32 MILLIMETERS 1" Flanged Side/Side G Std. 14" 18.97 — 18.97 — 12.71 14.00 12.71 14.00 12.71 14.00 13.71 14.00 13.71 14.00 13.71 14.00 13.71 14.00 13.71 14.00 G Std. 15.21 15.21 15.21 H 5.45 5.45 6.13 6.13 6.13 7.19 7.19 7.19 7.19 7.19 1" NPT Thread & Socket Weld J Std. 25.93 26.06 20.23 20.91 22.04 21.89 22.71 24.15 23.79 23.79 14" — — 21.51 22.19 23.32 22.19 23.00 24.43 24.08 24.08 A B C 397 397 232 232 232 257 257 257 257 257 80 80 92 92 92 119 119 119 119 119 574 577 423 440 469 465 486 522 513 537 J H A B C 16" Std. 16" 16.00 8.19 23.98 24.77 295 145 518 16.00 8.19 24.85 25.64 295 145 540 16.00 8.19 26.53 27.32 295 145 582 1" Flanged Upper Side/Bottom D F E Std. 14" Std. 14" 466 — 138 642 — 466 — 138 646 — 306 356 156 497 546 306 356 156 515 564 306 356 156 543 592 332 356 183 540 564 332 356 183 560 584 332 356 183 597 621 332 356 183 588 612 332 356 183 588 612 D F E Std. 16" Std. 16" 370 406 208 593 629 370 406 208 615 651 370 406 208 657 694 1" Flanged Side/Side G Std. 14" 482 — 482 — 323 356 323 356 323 356 348 356 348 356 348 356 348 356 348 356 G Std. 386 386 386 H 138 138 156 156 156 183 183 183 183 183 J Std. 659 662 514 531 560 556 577 613 604 604 14" — — 546 564 592 564 584 621 612 612 J H 16" Std. 16" 406 208 609 629 406 208 631 651 406 208 674 694 *See page 15 for ASME B31.1 600# dimensional information. CHAMBERS WITH 112⁄ - INCH CONNECTIONS INCHES 11⁄2" Flanged Head 11⁄2" NPT Threaded & Socket Weld Upper Side/Bottom Model Flg. Code rating D F B C E (lbs.) A Std. 14" Std. 14" 300 15.63 3.19 22.59 18.33 — 6.19 25.29 — C34 600 15.63 3.19 22.72 18.33 — 6.19 25.42 — 150 9.12 3.69 16.64 13.06 14.00 7.13 20.58 21.51 B3F 300 9.12 3.69 17.32 13.06 14.00 7.13 21.26 22.19 600 9.12 3.69 18.45 13.06 14.00 7.13 22.39 23.32 150 10.12 4.75 18.30 14.06 14.00 8.19 22.25 22.19 G3F 300 10.12 4.75 19.12 14.06 14.00 8.19 23.06 23.00 600 10.12 4.75 20.56 14.06 14.00 8.19 24.50 24.44 600 10.11 4.75 20.19 14.06 14.00 8.18 24.14 24.08 Z3F 900 10.11 4.75 21.13 14.06 14.00 8.18 24.14 24.08 D F A B C E Std. 16" Std. 16" 150 11.62 5.75 20.38 15.56 16.00 9.19 24.33 24.77 K3F 300 11.62 5.75 21.25 15.56 16.00 9.19 25.50 25.64 600 11.62 5.75 22.93 15.56 16.00 9.19 26.88 27.32 MILLIMETERS 11⁄2" Flanged Side/Side G Std. 14" 18.97 — 18.97 — 13.71 14.00 13.71 14.00 13.71 14.00 14.71 14.00 14.71 14.00 14.71 14.00 14.71 14.00 14.71 14.00 G Std. 16" 16.21 16.00 16.21 16.00 16.21 16.00 H 6.19 6.19 7.13 7.13 7.13 8.19 8.19 8.19 8.18 8.18 11⁄2" NPT Thread & Socket Weld J Std. 25.93 26.06 21.23 21.91 23.04 22.89 23.71 25.15 24.79 24.79 14" — — 21.51 22.19 23.32 22.19 23.00 24.44 24.08 24.08 J H Std. 9.19 24.98 9.19 25.85 9.19 27.53 A B C 397 397 232 232 232 257 257 257 257 257 81 81 94 94 94 121 121 121 121 121 574 577 423 440 469 465 486 522 513 537 A B C 16" 24.77 295 146 518 25.64 295 146 540 27.32 295 146 582 11⁄2" Flanged Upper Side/Bottom D F E Std. 14" Std. 14" 466 — 157 642 — 466 — 157 646 — 332 356 181 523 546 332 356 181 540 564 332 356 181 568 592 357 356 208 564 563 357 356 208 586 584 357 356 208 622 621 357 356 208 613 612 357 356 208 613 612 D F E Std. 16" Std. 16" 395 406 233 618 629 395 406 233 648 651 395 406 233 683 694 11⁄2" Flanged Side/Side G Std. 14" 482 — 482 — 348 356 348 356 348 356 374 356 374 356 374 356 374 356 374 356 G Std. 16" 412 406 412 406 412 406 H 157 157 181 181 181 208 208 208 208 208 J Std. 659 662 539 556 585 581 602 639 630 630 14" — — 546 564 592 564 584 621 612 612 J H 16" Std. 233 634 233 657 233 699 629 651 694 *See page 15 for ASME B31.1 600# dimensional information. CHAMBERS WITH 2 - INCH CONNECTIONS INCHES Head 2" NPT Threaded & Socket Weld Model Flg. Code rating B C (lbs.) A C34 B3F G3F Z3F K3F 300 600 150 300 600 150 300 600 600 900 15.63 15.63 9.12 9.12 9.12 10.12 10.12 10.12 10.11 10.11 3.31 3.31 3.81 3.81 3.81 4.88 4.88 4.88 4.87 4.87 22.59 22.72 16.64 17.32 18.45 18.30 19.12 20.56 20.19 21.13 A B C 150 11.62 5.88 20.38 300 11.62 5.88 21.25 600 11.62 5.88 22.93 2" Flanged Upper Side/Bottom D F E Std. 14" Std. 14" 18.33 — 6.25 25.29 — 18.33 — 6.25 25.42 — 13.06 14.00 7.13 20.58 21.51 13.06 14.00 7.13 21.26 22.19 13.06 14.00 7.13 22.39 23.32 14.06 14.00 8.19 22.25 22.19 14.06 14.00 8.19 23.06 23.00 14.06 14.00 8.19 24.50 24.44 14.06 14.00 8.18 24.14 24.08 14.06 14.00 8.18 24.14 24.08 D F E Std. 16" Std. 16" 15.56 16.00 9.19 24.33 24.77 15.56 16.00 9.19 25.50 25.64 15.56 16.00 9.19 26.88 27.32 MILLIMETERS 2" Flanged Side/Side G Std. 14" 18.97 — 18.97 — 13.71 14.00 13.71 14.00 13.71 14.00 14.71 14.00 14.71 14.00 14.71 14.00 14.71 14.00 14.71 14.00 G Std. 16" 16.21 16.00 16.21 16.00 16.21 16.00 H 6.25 6.25 7.13 7.13 7.13 8.19 8.19 8.19 8.18 8.18 H 2" NPT Thread & Socket Weld J Std. 25.93 26.06 21.23 21.91 23.04 22.89 23.71 25.15 24.79 24.79 Std. 9.19 24.98 9.19 25.85 9.19 27.53 14" — — 21.51 22.19 23.32 22.19 23.00 24.44 24.08 24.08 J A B C 397 397 232 232 232 257 257 257 257 257 84 84 97 97 97 124 124 124 124 124 574 577 423 440 469 465 486 522 513 537 A B C 16" 24.77 295 149 518 25.64 295 149 540 27.32 295 149 582 2" Flanged Upper Side/Bottom D F E Std. 14" Std. 14" 466 — 159 642 — 466 — 159 646 — 332 356 181 523 546 332 356 181 540 564 332 356 181 569 592 357 356 208 565 564 357 356 208 586 584 357 356 208 622 621 357 356 208 613 612 357 356 208 613 612 D F E Std. 16" Std. 16" 395 406 233 618 629 395 406 233 648 651 395 406 233 683 694 2" Flanged Side/Side G Std. 14" 482 — 482 — 348 356 348 356 348 356 374 356 374 356 374 356 374 356 374 356 G Std. 16" 412 406 412 406 412 406 H 159 159 181 181 181 208 208 208 208 208 J Std. 659 662 539 556 585 581 602 639 630 630 H Std. 233 634 233 657 233 699 *See page 15 for ASME B31.1 600# dimensional information. 14" — — 546 564 592 564 584 621 612 612 J 16" 629 651 694 13 D I M E N S I O N A L I N C H E S S P E C I F I C A T I O N S ( m m ) M ASME B31.1 & B31.3 FLANGED CAGE MODELS L All housings rotatable 360°. Allow 8 inches (203 mm) overhead clearance for cover removal. NEMA 1: 8.50 (216) TYPE 4X/7/9: 10.12 (257) Group B: 10.12 (257) K Plugged K Conduit Connections K Electrical Switches TYPE 4X/7/9: 1" NPT Group B: 1" NPT Pneumatic Switches 1 NEMA 1: ⁄4" NPT HL LL (Ref) C Outline Dimensions L M TYPE4X/7/9 TYPE4X/7/9 Group B 3.87 (98) 5.93 (151) NEMA 1 5.00 (127) 4.62 (117) A B Threaded and Socket Weld Upper Side/Bottom L M L K Plugged M K K Plugged HL K K LL HL (Ref) J G (Ref) F LL D H Flanged Side/Side 14 E Flanged Upper Side/Bottom D I M E N S I O N A L S P E C I F I C A T I O N S FLANGED CAGE MODELS — ASME B31.1 600# & 900# ANSI PRESSURE RATING CHAMBERS WITH 1- INCH CONNECTIONS INCHES Flg. Model Size Code (lbs.) B3F 600 1" NPT Threaded & Socket Weld 1" Flanged 1" Flanged 1" NPT Thread 1" Flanged 1" Flanged Upper Side/Bottom Side/Side & Socket Weld Upper Side/Bottom Side/Side D F G J D F G J A B C E H A B C E H Std. 14" Std. 14" Std. 14" Std. 14" Std. 14" Std. 14" Std. 14" Std. 14" 9.12 3.63 18.39 — 14.00 9.00 — 23.32 — 14.00 9.00 — 23.32 232 92 467 — 356 229 — 592 — 356 229 — 592 A G3F Z3F B C 600 10.12 4.69 20.51 600 10.11 4.68 20.19 900 10.11 4.68 21.13 D Std. — — — F 16" 16.00 10.00 16.00 10.00 16.00 10.00 B 16" Std. — — — 26.44 26.08 26.08 — — — Std. 18" Std. — 29.32 — F C H 16" 16.00 10.00 16.00 10.00 16.00 10.00 — 18" 18.00 11.00 J Std. 16" — — — G 1 ⁄2" NPT Threaded & Socket Weld 600 A G3F Z3F B C 600 10.12 4.75 20.51 600 10.11 4.75 20.19 900 10.11 4.75 21.13 D Std. 16" 18" A Std. 18.00 11.00 E D H F G Std. 16" Std. 16" H J Std. 16" B C 18" — F G E Std. 18" 671 662 662 J H Std. 18" Std. 18" Std. 18" 29.32 295 145 581 — 457 279 — 745 — 457 279 — 745 MILLIMETERS 1 1 D Std. — — — F 16" 16.00 10.00 16.00 10.00 16.00 10.00 B 16" Std. — — — 26.44 26.08 26.08 — — — Std. 18" Std. — 29.32 — F C 16" — 18" 18.00 11.00 H 16.00 10.00 16.00 10.00 16.00 10.00 J Std. 16" — — — G A B C D Std. 16" D H 18" A Std. 18.00 11.00 E F G Std. 16" Std. 16" H J Std. 16" 26.43 257 121 521 — 406 254 — 672 — 406 254 — 26.08 257 121 513 — 406 254 — 662 — 406 254 — 26.08 257 121 537 — 406 254 — 662 — 406 254 — J E Std. 600 11.62 5.75 22.89 G Std. D A K3F C 1 ⁄2" Flanged 1 ⁄2" Flanged 11⁄2" NPT Thread 11⁄2" Flanged 11⁄2" Flanged Upper Side/Bottom Side/Side & Socket Weld Upper Side/Bottom Side/Side D F G J D F G J A B C E H A B C E H Std. 14" Std. 14" Std. 14" Std. 14" Std. 14" Std. 14" Std. 14" Std. 14" 9.12 3.69 18.39 — 14.00 9.00 — 23.32 — 14.00 9.00 — 23.32 232 94 467 — 356 229 — 592 — 356 229 — 592 1 B3F B 26.43 257 119 521 — 406 254 — 672 — 406 254 — 26.08 257 119 513 — 406 254 — 662 — 406 254 — 26.08 257 119 537 — 406 254 — 662 — 406 254 — CHAMBERS WITH 112⁄ - INCH CONNECTIONS INCHES Flg. Model Size Code (lbs.) A J E Std. 600 11.62 5.69 22.89 G Std. D A K3F MILLIMETERS B C 18" — F G E Std. 18" 671 662 662 J H Std. 18" Std. 18" Std. 18" 29.32 295 146 581 — 457 279 — 745 — 457 279 — CHAMBERS WITH 2 - INCH CONNECTIONS INCHES 745 MILLIMETERS 2" NPT Threaded & Socket Weld 2" Flanged 2" Flanged 2" NPT Thread 2" Flanged 2" Flanged Flg. Side/Side & Socket Weld Upper Side/Bottom Side/Side Upper Side/Bottom Model Size Code D F G J D F G J (lbs.) A B C E H A B C E H Std. 14" Std. 14" Std. 14" Std. 14" Std. 14" Std. 14" Std. 14" Std. 14" B3F 600 9.12 3.81 18.39 — 14.00 9.00 — 23.32 — 14.00 9.00 — 23.32 232 97 467 — 356 229 — 592 — 356 229 — 592 A G3F Z3F B C 600 10.12 4.88 20.51 600 10.11 4.87 20.19 900 10.11 4.87 21.13 D Std. — — — F 16" 16.00 10.00 16.00 10.00 16.00 10.00 16" Std. — — — 26.44 26.08 26.08 — — — Std. 18" Std. — 29.32 — D A B F C 600 11.62 5.88 22.89 16" — 18" 18.00 11.00 H 16.00 10.00 16.00 10.00 16.00 10.00 J Std. 16" — — — G A B C 18.00 11.00 A Std. — E D H 18" D Std. 16" F G Std. 16" Std. 16" H J Std. 16" 26.43 257 124 521 — 406 254 — 672 — 406 254 — 26.08 257 124 513 — 406 254 — 662 — 406 254 — 26.08 257 124 537 — 406 254 — 662 — 406 254 — J E Std. K3F G Std. 18" B C F G E Std. 18" 671 662 662 J H Std. 18" Std. 18" Std. 18" 29.32 295 149 581 — 457 279 — 745 — 457 279 — 745 15 A S M E B 3 1 . 1 S E A L E D C A G E M O D E L N U M B E R S M O D E L S Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP) MODEL NUMBER CODE Pressure Rating Model Code Minimum Specific Gravity 100 550 750 800 38 288 399 427 B35 0.69 830 830 716 594 57.2 57.2 49.6 41.0 C35 0.57 500 435 400 395 34.5 30.0 27.6 27.2 G35 0.54 750 653 600 593 51.7 45.0 41.4 40.9 0.71 1680 1680 1455 1210 115.8 115.8 100.3 83.4 0.66 1645 1645 1425 1185 113.4 113.4 98.3 81.7 V35 Z35 psig @ ° F bar @ ° C MATERIALS OF CONSTRUCTION P Carbon steel chamber, 316L stainless steel float, 400 series stainless steel sleeve, ASME B31.1 Construction 7 P22/F22 Chrome-Moly chamber, 347 SS float, 400 series SS sleeve, ASME B31.1 Construction, model B35 only SEALED CAGE SIZE AND TANK CONNECTION TYPE Type C/C 1" Connection Size 11⁄2" 2" Threaded Socket Weld Std. Std. B20 B30 C20 C30 D20 D30 Cage Mounting ANSI Flange Rating (lbs.) Flanged Upper Side/ Bottom Flanged Side/Side Std. 14" 16" Std. 14" 16" 150 300 600 900 150 300 600 900 150 300 600 900 N30 N34 — S30 S34 — N40 N44 — S40 S44 — — N54 N56 — S54 S56 — N64 N66 — S64 S66 P30 P34 — T30 T34 — P40 P44 — T40 T44 — — P54 P56 — T54 T56 — P64 P66 — T64 T66 Q30 Q34 — V30 V34 — Q40 Q44 — V40 V44 — — Q54 Q56 — V54 V56 — Q64 Q66 — V64 V66 PNEUMATIC SWITCH MECHANISM AND ENCLOSURE Switch Description Series J Bleed Type Series K Non-Bleed Maximum Supply Pressure Maximum Process Temperature Bleed Orifice Diameter Models B35, C35, & G35 Models V35 & Z35 psig bar °F °C inches mm NEMA 1 NEMA 1 100 7 400 204 .063 1.6 JGH JGF 60 4 400 204 .094 2.3 JHH JHF 60 4 700 371 .055 1.3 JJH JJF 100 7 400 204 — — — KOF 40 3 400 204 — — KOH — Models are limited to maximum temperature rating of selected switch mechanism. Minimum specific gravity ratings apply to single stage units only. Consult factory for two or three stage units. Models V35 and Z35 contain 17–7 ph stainless steel floats. Codes for a 16-inch center to center dimension are applicable to Models G35 with 600# flanges and Z35 with 600 & 900# flanges only. Process temperature based on +100° F (+38° C) ambient. For models built to ASME B31.1 in applications over +750° F (+399°C), 100% radiographic examination is required. Consult factory for pricing. HS & H1 switches can be used with only materials of construction code 1 on models V35 & Z35 16 ELECTRIC SWITCH MECHANISM AND ENCLOSURE Switch Description Series B Snap Switch Series C Snap Switch Series D DC Current Snap Switch Series F Hermetically Sealed Snap Switch Series HS Hermetically Sealed 5-amp Snap Switch with Wiring Leads Models B35, C35 & G35 Models V35 & Z35 Process TYPE 4X/7/9 Aluminum Enclosure Temperature Set Contacts Range ATEX ATEX Points Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 Ex II 2 G EEx Ex II 2 G EEx °F (°C) Groups C&D Group B Groups C&D Group B d IIC T6 d IIC T6 1 BKA BKJ BCC BKB BKK BC9 SPDT 2 BLA BLJ BDC BLB BLK BD9 -40 to +250 3 BMA BMJ BEC BMB BMK BE9 (-40 to +121) 1 BNA BNJ BFC BNB BNK BF9 DPDT 2 BOA BOJ BGC BOB BOK BG9 1 CKA CKJ CCC CKB CKK CC9 SPDT 2 CLA CLJ CDC CLB CLK CD9 -40 to +450 3 CMA CMJ CEC CMB CMK CE9 (-40 to +232) 1 CNA CNJ CFC CNB CNK CF9 DPDT 2 COA COJ CGC COB COK CG9 1 DKB DKK DC9 DKB DKK DC9 SPDT 2 DLB DLK DD9 DLB DLK DD9 -40 to +250 3 DMB DMK DE9 DMB DMK DE9 (-40 to +121) 1 DNB DNK DF9 DNB DNK DF9 DPDT 2 DOB DOK DG9 DOB DOK DG9 1 FKA FKJ FCC FKB FKK FC9 SPDT 2 FLA FLJ FDC FLB FLK FD9 -50 to +750 (-46 to +399) 1 FNA FNJ FFC FNB FNK FF9 DPDT 2 FOA FOJ FGC FOB FOK FG9 1 HMJ HMK HMJ HMK SPDT 2 HMN HMP HMN HMP -50 to +400 N/A N/A (-46 to +204) 1 HMS HMT HMS HMT DPDT 2 HMY HMZ HMY HMZ Series HS Hermetically Sealed 5-amp Snap Switch with Terminal Block -50 to +400 (-46 to +204) Series H1 Hermetically Sealed 1-amp Snap Switch with Wiring Leads -50 to +750 (-46 to +399) Series R High Temperature Snap Switch -40 to +750 (-40 to +399) Series 8 Hermetically Sealed Snap Switch -50 to +750 (-46 to +399) Series 9 High Temperature Hermetically Sealed Snap Switch -50 to +750 (-46 to +399) Switch Description Series R High Temperature Snap Switch Series 9 High Temperature Hermetically Sealed Snap Switch SPDT 1 HM3 HM4 HA9 HM3 HM4 HA9 DPDT 1 HM7 HM8 HB9 HM7 HM8 HB9 SPDT 1 HKJ HKK HKJ HKK HKN HKP RKB RLB RNB ROB 8KB 8LB 8MB 8NB 8OB 9KB 9LB 9MB 9NB 9OB RKK RLK RNK ROK 8KK 8LK 8MK 8NK 8OK 9KK 9LK 9MK 9NK 9OK N/A DPDT SPDT DPDT SPDT DPDT SPDT DPDT 2 HKN HKP 1 2 1 2 1 2 3 1 2 1 2 3 1 2 RKB RLB RNB ROB 8KA 8LA 8MA 8NA 8OA 9KA 9LA 9MA 9NA 9OA RKK RLK RNK ROK 8KJ 8LJ 8MJ 8NJ 8OJ 9KJ 9LJ 9MJ 9NJ 9OJ RC9 RD9 RF9 RG9 8CC 8DC 8EC 8FC 8GC 9CC 9DC 9EC 9FC 9GC N/A RC9 RD9 RF9 RG9 8C9 8D9 8E9 8F9 8G9 9C9 9D9 9E9 9F9 9G9 Process Cast Iron Cast Iron CS/Aluminum CS/Aluminum Set Temp. Range Contacts Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 Points NEMA 4X NEMA 4X °F (°C) Groups C&D Group B Groups C&D Group B 1 R1M RKM RKW R1M RKM RKW SPDT 2 R3M RLM RLW R3M RLM RLW -40 to +1000 (-40 to +538) 1 RDM RNM RNW RDM RNM RNW DPDT 2 REM ROM ROW REM ROM ROW 1 9AD 9KD 9KV 9AM 9KM 9KW SPDT 2 9BD 9LD 9LV 9BM 9LM 9LW -50 to +1000 3 9CD 9MD 9MV 9CM 9MM 9MW (-46 to +538) 1 9DD 9ND 9NV 9DM 9NM 9NW DPDT 2 9ED 9OD 9OV 9EM 9OM 9OW 17 A S M E B 3 1 . 1 F L A N G E D M O D E L C A G E N U M B E R S M O D E L S Models available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP) MODEL NUMBER CODE Model Code B3F G3F K3F Z3F Pressure Rating Head Flange ANSI Class Minimum S.G. Gravity 1 100 550 750 150# 0.78 285 155 95 300# 0.66 740 588 600# 0.66 960 150# 0.41 285 300# 0.55 740 600# 0.70 1000 600# 0.60 1410 1480 1147 1645 1645 600# 900# psig @ ° F 0.67 bar @ ° C 38 288 399 80 19.6 10.7 6.5 5.5 505 410 51.0 39.6 34.8 28.3 870 800 790 66.1 60.1 55.6 54.5 155 95 80 19.6 10.7 6.5 5.5 588 505 410 51.0 45.0 41.4 28.3 870 800 790 68.9 60.0 55.6 54.5 1147 1010 825 97.2 79.1 69.6 56.9 1010 825 102.0 79.1 69.6 56.9 1425 1185 151.2 113.4 98.3 81.7 800 427 MATERIALS OF CONSTRUCTION P Carbon steel chamber, 316L stainless steel float, 400 stainless steel sleeve, ASME B31.1 Construction CAGE SIZE AND TANK CONNECTION TYPE Connection Type C/C Connection Size 11⁄2" 1" 2" ANSI Head Flange Rating (lbs.) Threaded Socket Weld Flanged Upper Side/ Bottom Flanged Side/Side Std. Std. Std. 14" 16" 18" Std. 14" 16" 18" 150 300 600 900 150 300 600 900 150 300 600 900 B20 B30 N30 N34 — — S30 S34 — — B60 B70 N40 N44 — — S40 S44 — — B80 B90 — N54 N56 N58 — S54 S56 S58 B40 B50 — N64 N66 — — S64 S66 — C20 C30 P30 P34 — — T30 T34 — — C60 C70 P40 P44 — — T40 T44 — — C80 C90 — P54 P56 P58 — T54 T56 T56 C40 C50 — P64 P66 — — T64 T66 — D20 D30 Q30 Q34 — — V30 V34 — — D60 D70 Q40 Q44 — — V40 V44 — — D80 D90 — Q54 Q56 Q58 — V54 V56 Q58 D40 D50 — Q64 Q66 — — V64 V66 — PNEUMATIC SWITCH MECHANISM AND ENCLOSURE Switch Description Series J Bleed Type Series K Non-Bleed Maximum Supply Pressure Maximum Process Temperature Bleed Orifice Diameter All Models Models except: B3F, G3F, B3F, G3F, K3F & Z3F K3F & Z3F with 600 lb. with 600 & 900 lb. Head Flanges Head Flanges psig bar °F °C inches mm NEMA 1 NEMA 1 100 7 400 204 .063 1.6 JGH JGF 50 4 400 204 .094 2.3 JHH JHF 60 4 700 371 .055 1.3 JJH JJF 100 7 400 204 — — — KOF 40 3 400 204 — — KOH — Minimum specific gravity ratings apply to single stage units only. Consult factory for two or three stage units. Models are limited to maximum temperature rating of selected switch mechanism. Models Z3F & K3F contain 7–17 ph stainless steel floats. Codes for a 16 inch center to center dimension are applicable to models G3F and Z3F with 600# flanges only. Codes for an 18-inch center to center dimension are applicable to K3F model only. Process temperature based on +100° F (+38° C) ambient. For models built to ASME B31.1 in applications over +750° F (+399°C), 100% radiographic examination is required. Consult factory for pricing. 18 HS & H1 switches can be used with only materials of construction code 1 on all models with 600# or 900# ANSI rating. ELECTRIC SWITCH MECHANISM AND ENCLOSURE Switch Description Series B Snap Switch Series C Snap Switch Series D DC Current Snap Switch Series F Hermetically Sealed Snap Switch Series HS Hermetically Sealed 5-amp Snap Switch with Wiring Leads All models except B3F, G3F, K3F & Z3F Models B3F, G3F, K3F & Z3F with 600# or 900# ANSI ratings with 600# or 900# ANSI ratings Process Temperature Set TYPE 4X/7/9 Aluminum Enclosure Contacts Range Points ATEX ATEX Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 °F (°C) Ex II 2 G EEx Ex II 2 G EEx Groups C&D Group B Groups C&D Group B d IIC T6 d IIC T6 1 BKA BKJ BCC BKB BKK BC9 SPDT 2 BLA BLJ BDC BLB BLK BD9 -40 to +250 3 BMA BMJ BEC BMB BMK BE9 (-40 to +121) 1 BNA BNJ BFC BNB BNK BF9 DPDT 2 BOA BOJ BGC BOB BOK BG9 1 CKA CKJ CCC CKB CKK CC9 SPDT 2 CLA CLJ CDC CLB CLK CD9 -40 to +450 3 CMA CMJ CEC CMB CMK CE9 (-40 to +232) 1 CNA CNJ CFC CNB CNK CF9 DPDT 2 COA COJ CGC COB COK CG9 1 DKB DKK DC9 DKB DKK DC9 SPDT 2 DLB DLK DD9 DLB DLK DD9 -40 to +250 3 DMB DMK DE9 DMB DMK DE9 (-40 to +121) 1 DNB DNK DF9 DNB DNK DF9 DPDT 2 DOB DOK DG9 DOB DOK DG9 1 FKA FKJ FCC FKB FKK FC9 SPDT 2 FLA FLJ FDC FLB FLK FD9 -50 to +750 (-46 to +399) 1 FNA FNJ FFC FNB FNK FF9 DPDT 2 FOA FOJ FGC FOB FOK FG9 1 HMJ HMK HMJ HMK SPDT 2 HMN HMP HMN HMP -50 to +400 N/A N/A (-46 to +204) 1 HMS HMT HMS HMT DPDT 2 HMY HMZ HMY HMZ Series HS Hermetically Sealed 5-amp Snap Switch with Terminal Block -50 to +400 (-46 to +204) Series H1 Hermetically Sealed 1-amp Snap Switch with Wiring Leads -50 to +750 (-46 to +399) Series R High Temperature Snap Switch -40 to +750 (-40 to +399) Series 8 Hermetically Sealed Snap Switch -50 to +750 (-46 to +399) Series 9 High Temperature Hermetically Sealed Snap Switch -50 to +750 (-46 to +399) Switch Description Series R High Temperature Snap Switch Series 9 High Temperature Hermetically Sealed Snap Switch SPDT 1 HM3 HM4 HA9 HM3 HM4 HA9 DPDT 1 HM7 HM8 HB9 HM7 HM8 HB9 SPDT 1 HKJ HKK HKJ HKK HKN HKP RKB RLB RNB ROB 8KB 8LB 8MB 8NB 8OB 9KB 9LB 9MB 9NB 9OB RKK RLK RNK ROK 8KK 8LK 8MK 8NK 8OK 9KK 9LK 9MK 9NK 9OK N/A DPDT SPDT DPDT SPDT DPDT SPDT DPDT 2 HKN HKP 1 2 1 2 1 2 3 1 2 1 2 3 1 2 RKB RLB RNB ROB 8KA 8LA 8MA 8NA 8OA 9KA 9LA 9MA 9NA 9OA RKK RLK RNK ROK 8KJ 8LJ 8MJ 8NJ 8OJ 9KJ 9LJ 9MJ 9NJ 9OJ RC9 RD9 RF9 RG9 8CC 8DC 8EC 8FC 8GC 9CC 9DC 9EC 9FC 9GC N/A RC9 RD9 RF9 RG9 8C9 8D9 8E9 8F9 8G9 9C9 9D9 9E9 9F9 9G9 Process Cast Iron Cast Iron CS/Aluminum CS/Aluminum Set Temp. Range Contacts Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 Points NEMA 4X NEMA 4X °F (°C) Groups C&D Group B Groups C&D Group B 1 R1M RKM RKW R1M RKM RKW SPDT 2 R3M RLM RLW R3M RLM RLW -40 to +1000 (-40 to +538) 1 RDM RNM RNW RDM RNM RNW DPDT 2 REM ROM ROW REM ROM ROW 1 9AD 9KD 9KV 9AM 9KM 9KW SPDT 2 9BD 9LD 9LV 9BM 9LM 9LW -50 to +1000 3 9CD 9MD 9MV 9CM 9MM 9MW (-46 to +538) 1 9DD 9ND 9NV 9DM 9NM 9NW DPDT 2 9ED 9OD 9OV 9EM 9OM 9OW 19 A S M E B 3 1 . 3 S E A L E D C A G E M O D E L N U M B E R S M O D E L S MODEL NUMBER CODE Model Code Pressure Rating Min. S.G. for Models with Material of Construction Code 1 psig @ ° F bar @ ° C 2 100 550 750 800 900 1000 38 288 399 427 482 538 — — — — — 138 68.9 60.0 49.6 41.0 34.5 30.0 27.6 27.2 134 51.7 45.0 41.4 40.9 121 41.4 36.0 33.1 32.7 20.7 154.4 18.0 131.9 16.5 100.3 16.3 83.4 — — — — — 9.5 138 50.2 9.2 n/a 151.2 131.9 98.3 81.7 49.2 n/a 38 93 149 89.6 84.4 78.9 FLOAT MODELS B35 0.69 0.72 1000 870 716 594 C35 0.57 0.59 500 435 400 395 G35 0.54 0.56 750 653 600 593 0.40 0.40 600 522 480 474 0.41 0.71 0.43 0.81 300 2240 261 1913 240 1455 237 1210 728 134 n/a 0.66 0.71 2193 1913 1425 1185 713 n/a 100 200 300 1300 1225 1145 K35 L35 V35 Z35 DISPLACER MODEL B34 0.40 0.40 n/a 9.5 9.2 8.3 n/a MATERIALS OF CONSTRUCTION 1 2 Carbon steel chamber, 316L stainless steel float, 400 stainless steel sleeve, ASME B31.3 construction Carbon steel chamber, 316L stainless steel float, 316 stainless steel sleeve, ASME B31.3 construction TANK CONNECTION TYPE AND SIZE Type Threaded Socket Weld Size 11⁄2" C/C 1" Std. Std. B20 B30 2" D20 D30 C20 C30 Cage Mounting ANSI Flange Rating (lbs.) Flanged Upper Side/ Bottom Flanged Side/Side Std. 14" 16" Std. 14" 16" 150 300 600 900 150 300 600 900 150 300 600 900 N30 N34 N36 S30 S34 S36 N40 N44 N46 S40 S44 S46 N50 N54 N56 S50 S54 S56 N60 N64 N66 S60 S64 S66 P30 P34 P36 T30 T34 T36 P40 P44 P46 T40 T44 T46 P50 P54 P56 T50 T54 T56 P60 P64 P66 S60 S64 S66 Q30 Q34 Q36 V30 V34 V36 Q40 Q44 Q46 V40 V44 V46 Q50 Q54 Q56 V50 V54 V56 Q60 Q64 Q66 V60 V64 V66 PNEUMATIC SWITCH MECHANISM AND ENCLOSURE Switch Description Series J Bleed Type Series K Non-Bleed 20 Maximum Supply Pressure Maximum Process Temperature Bleed Orifice Diameter Models B35, C35, Models B34, V35, G35, K35 & L35 Z35 & All Models with Material of with Material of Constr. Code 1 Constr. Code 2 psig bar °F °C inches mm NEMA 1 NEMA 1 100 7 400 204 .063 1.6 JGH JGF 60 4 400 204 .094 2.3 JHH JHF 60 4 700 371 .055 1.3 JJH JJF 100 7 400 204 — — — KOF 40 3 400 204 — — KOH — Minimum SG ratings apply to single stage units. Consult factory for two and three stage units. Models are limited to maximum temperature rating of selected switch mechanism. Consult factory for 14" center-to-center dimensions on models K35 & B34. Models V35 and Z35 contain 17–7 ph stainless steel floats. Consult factory for Model B34 above +300° F (+149° C). Available with single switch only. Codes 11⁄2" and 2" NPT tank connections are not applicable to the B34 displacer model. Codes for a 16" center-to-center dimension are applicable to the K35 model only. Process temperature based on +100° F (+38° C) ambient. On condensing applications, temperature down-rated to +400° F (+204° C) process at +100° F (+38° C) ambient. HS & H1 switches can be used with only materials of construction code 1 on models V35 & Z35 ELECTRIC SWITCH MECHANISM AND ENCLOSURE Switch Description Series B Snap Switch Series C Snap Switch Series D DC Current Snap Switch Series F Hermetically Sealed Snap Switch Series HS Hermetically Sealed 5-amp Snap Switch with Wiring Leads Models B35, C35, K35 & L35 Models B34, V35, Z35 & all models with Material of Construction Code 1 with Material of Construction Code 2 Process Temperature Set TYPE 4X/7/9 Aluminum Enclosure Contacts Range Points ATEX ATEX Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 °F (°C) Ex II 2 G EEx Ex II 2 G EEx Groups C&D Group B Groups C&D Group B d IIC T6 d IIC T6 1 BKA BKJ BCC BKB BKK BC9 SPDT 2 BLA BLJ BDC BLB BLK BD9 -40 to +250 3 BMA BMJ BEC BMB BMK BE9 (-40 to +121) 1 BNA BNJ BFC BNB BNK BF9 DPDT 2 BOA BOJ BGC BOB BOK BG9 1 CKA CKJ CCC CKB CKK CC9 SPDT 2 CLA CLJ CDC CLB CLK CD9 -40 to +450 3 CMA CMJ CEC CMB CMK CE9 (-40 to +232) 1 CNA CNJ CFC CNB CNK CF9 DPDT 2 COA COJ CGC COB COK CG9 1 DKB DKK DC9 DKB DKK DC9 SPDT 2 DLB DLK DD9 DLB DLK DD9 -40 to +250 3 DMB DMK DE9 DMB DMK DE9 (-40 to +121) 1 DNB DNK DF9 DNB DNK DF9 DPDT 2 DOB DOK DG9 DOB DOK DG9 1 FKA FKJ FCC FKB FKK FC9 SPDT 2 FLA FLJ FDC FLB FLK FD9 -50 to +750 (-46 to +399) 1 FNA FNJ FFC FNB FNK FF9 DPDT 2 FOA FOJ FGC FOB FOK FG9 1 HMJ HMK HMJ HMK SPDT 2 HMN HMP HMN HMP -50 to +550 N/A N/A (-46 to +288) 1 HMS HMT HMS HMT DPDT 2 HMY HMZ HMY HMZ Series HS Hermetically Sealed 5-amp Snap Switch with Terminal Block -50 to +550 (-46 to +288) Series H1 Hermetically Sealed 1-amp Snap Switch with Wiring Leads -50 to +750 (-46 to +399) Series R High Temperature Snap Switch -40 to +750 (-40 to +399) Series 8 Hermetically Sealed Snap Switch -50 to +750 (-46 to +399) Series 9 High Temperature Hermetically Sealed Snap Switch -50 to +750 (-46 to +399) Switch Description Series R High Temperature Snap Switch Series 9 High Temperature Hermetically Sealed Snap Switch SPDT 1 HM3 HM4 HA9 HM3 HM4 HA9 DPDT 1 HM7 HM8 HB9 HM7 HM8 HB9 SPDT 1 HKJ HKK HKJ HKK HKN HKP RKB RLB RNB ROB 8KB 8LB 8MB 8NB 8OB 9KB 9LB 9MB 9NB 9OB RKK RLK RNK ROK 8KK 8LK 8MK 8NK 8OK 9KK 9LK 9MK 9NK 9OK N/A DPDT SPDT DPDT SPDT DPDT SPDT DPDT 2 HKN HKP 1 2 1 2 1 2 3 1 2 1 2 3 1 2 RKB RLB RNB ROB 8KA 8LA 8MA 8NA 8OA 9KA 9LA 9MA 9NA 9OA RKK RLK RNK ROK 8KJ 8LJ 8MJ 8NJ 8OJ 9KJ 9LJ 9MJ 9NJ 9OJ RC9 RD9 RF9 RG9 8CC 8DC 8EC 8FC 8GC 9CC 9DC 9EC 9FC 9GC N/A RC9 RD9 RF9 RG9 8C9 8D9 8E9 8F9 8G9 9C9 9D9 9E9 9F9 9G9 Process Cast Iron Cast Iron CS/Aluminum CS/Aluminum Set Temp. Range Contacts Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 Points NEMA 4X NEMA 4X °F (°C) Groups C&D Group B Groups C&D Group B 1 R1M RKM RKW R1M RKM RKW SPDT 2 R3M RLM RLW R3M RLM RLW -40 to +1000 (-40 to +538) 1 RDM RNM RNW RDM RNM RNW DPDT 2 REM ROM ROW REM ROM ROW 1 9AD 9KD 9KV 9AM 9KM 9KW SPDT 2 9BD 9LD 9LV 9BM 9LM 9LW -50 to +1000 3 9CD 9MD 9MV 9CM 9MM 9MW (-46 to +538) 1 9DD 9ND 9NV 9DM 9NM 9NW DPDT 2 9ED 9OD 9OV 9EM 9OM 9OW 21 A S M E B 3 1 . 3 F L A N G E D C A G E a n d N A C E M O D E L M O D E L S MODEL NUMBER CODE Model Code Head Flange ANSI Class FLOAT MODELS 150# B3F 300# 600# 150# G3F 300# 600# 150# K3F 300# 600# 600# Z3F 900# DISPLACER MODELS 300# C34 600# Minimum SG N U M B E R S Min. S.G. for Models with Material of Construction Code Pressure Rating psig @ ° F bar @ ° C 1 2 or N 100 550 750 800 900 1000 38 288 399 427 482 538 0.78 0.66 0.66 0.41 0.55 0.70 0.33 0.40 0.60 0.67 0.67 0.83 0.68 0.71 0.43 0.56 0.76 0.33 0.40 0.62 0.74 0.73 285 740 1000 285 740 1000 285 600 1480 1480 2193 100 740 1480 0.40 155 588 870 155 588 870 155 522 1147 1147 1718 300 655 1310 0.40 95 505 800 95 505 800 95 480 1010 1010 1425 500 600 1200 0.44 80 410 790 80 410 790 80 474 825 825 1185 — — — — — — — — 20 50 105 20 50 105 20 50 n/a n/a n/a 19.6 51.0 68.9 19.6 51.0 68.9 19.6 41.4 102.0 102.0 151.2 100 51.0 102.0 0.40 10.7 39.6 60.0 10.7 45.0 60.0 10.7 36.0 79.1 79.1 118.5 300 45.2 90.7 0.40 6.5 34.8 55.6 6.5 41.1 55.6 6.5 33.1 69.6 69.6 98.3 500 41.1 82.7 0.44 5.5 28.3 54.5 5.5 28.3 54.5 5.5 32.7 56.9 56.9 81.7 — — — — — — — — 1.4 3.4 7.2 1.4 3.4 7.2 1.4 3.4 n/a n/a n/a n/a 345 345 515 n/a 92.7 92.7 35.5 n/a MATERIALS OF CONSTRUCTION 1 2 N Carbon steel chamber, 316L stainless steel float, 400 stainless steel sleeve, ASME B31.3 Construction Carbon steel chamber, 316L stainless steel float, 316 stainless steel sleeve, ASME B31.3 Construction Carbon steel chamber, 316L stainless steel float, 316 stainless steel sleeve, NACE and ASME B31.3 Construction NACE construction: float cage is thermally stress relieved after welding, then hardness tested to assure compliance. Complies with NACE MR0175 & MR0103 latest revisions. TANK CONNECTION TYPE AND SIZE Connection Type Threaded s/b Socket Weld s/b Flanged Upper Side/ Bottom Flanged Side/Side C/C Std. Std. Std. 14" 16" Std. 14" 16" 1" 150 B20 B30 N30 N34 N36 S30 S34 S36 300 B60 B70 N40 N44 N46 S40 S44 S46 600 B80 B90 N50 N54 N56 S50 S54 S56 Size 11⁄2" ANSI Head Flange Rating (lbs.) 900 150 300 600 900 150 B40 C20 C60 C80 C40 D20 B50 C30 C70 C90 C50 D30 N60 P30 P40 P50 P60 Q30 N64 P34 P44 P54 P64 Q34 N66 P36 P46 P56 P66 Q36 S60 T30 T40 T50 T60 V30 S64 T34 T44 T54 T64 V34 S66 T36 T46 T56 T66 V36 2" 300 D60 D70 Q40 Q44 Q46 V40 V44 V46 600 D80 D90 Q50 Q54 Q56 V50 V54 V56 900 D40 D50 Q60 Q64 Q66 V60 V64 V66 PNEUMATIC SWITCH MECHANISM AND ENCLOSURE Switch Description Series J Bleed Type Series K Non-Bleed Maximum Maximum Supply Process Pressure Temperature psig 100 50 60 100 40 bar 7 4 4 7 3 °F 400 400 700 400 400 °C 204 204 371 204 204 Bleed Orifice Diameter inches .063 .094 .055 — — mm 1.6 2.3 1.3 — — All Models with Material of Construction Code 1 except B3F, C34, K34, G3F & Z3F with 600# or 900# ANSI rating Model C34 and All Models with Material of Construction Code 2 or N and B3F, G3F, K3F & Z3F with 600# or 900# ANSI rating NEMA 1 JGH JHH JJH — KOH NEMA 1 JGF JHF JJF KOF — Minimum SG ratings apply to single stage units. Consult factory for two and three stage units. Models are limited to maximum temperature rating of selected switch mechanism. 600# and 900# flanged cage models must use switch codes listed under heading “Model C34 & All Models w/Materials of Construction Codes 2 or N and B3F, G3F, K3F & Z3F with 600# or 900# ANSI rating”. HS switches can be used with Materials of Construction Code 1 only. Consult factory for 14" center-to-center dimensions on models K3F and C34. Construction Code N is not applicable to this unit due to 17–7 ph stainless steel float Example: B3F-1B80-HSG. 22 material. Consult factory for Model C34 up to +750° F (+399° C). Codes for 150 lb. flanges are not applicable to the C34 displacer model. Codes for a 16" center-to-center dimension are applicable to the K3F model only. Process temperature based on +100° F (+38° C) ambient. 11 On condensing applications, temperature down-rated to +400° F (+204° C) process at +100° F (+38° C) ambient. 12 On condensing applications, temperature down-rated to +400° F (+204° C) process at +100° F (+38° C) ambient ELECTRIC SWITCH MECHANISM AND ENCLOSURE Switch Description Process Temperature Set Contacts Range Points °F (°C) Series B Snap Switch -40 to +250 (-40 to +121) SPDT DPDT Series C Snap Switch -40 to +450 (-40 to +232) SPDT DPDT Series D DC Current Snap Switch -40 to +250 (-40 to +121) SPDT DPDT Series F Hermetically Sealed Snap Switch -50 to +750 (-46 to +399) Series HS Hermetically Sealed 5-amp Snap Switch with Wiring Leads -50 to +550 11 (-46 to +288) Series HS Hermetically Sealed 5-amp Snap Switch with Terminal Block -50 to +550 11 (-46 to +288) Series H1 Hermetically Sealed 1-amp Snap Switch with Wiring Leads -50 to +750 (-46 to +399) Series R High Temperature Snap Switch -40 to +750 (-40 to +399) Series 8 Hermetically Sealed Snap Switch -50 to +750 (-46 to +399) Series 9 High Temperature Hermetically Sealed Snap Switch -50 to +750 (-46 to +399) Switch Description Series R High Temperature Snap Switch Series 9 High Temperature Hermetically Sealed Snap Switch SPDT DPDT SPDT DPDT 1 2 3 1 2 1 2 3 1 2 1 2 3 1 2 1 2 1 2 1 2 1 2 All models C34 and all models with Material of Construction Code 1 except B3F, G3F, K3F & Z3F with 600# or 900# ANSI ratings All models C34 and all models with Material of Construction Codes 2 & N and B3F, G3F, K3F & Z3F with 600# or 900# ANSI ratings TYPE 4X/7/9 Aluminum Enclosure ATEX ATEX Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 Ex II 2 G EEx Ex II 2 G EEx Groups C&D Group B Groups C&D Group B d IIC T6 d IIC T6 BKA BKJ BCC BKB BKK BC9 BLA BLJ BDC BLB BLK BD9 BMA BMJ BEC BMB BMK BE9 BNA BNJ BFC BNB BNK BF9 BOA BOJ BGC BOB BOK BG9 CKA CKJ CCC CKB CKK CC9 CLA CLJ CDC CLB CLK CD9 CMA CMJ CEC CMB CMK CE9 CNA CNJ CFC CNB CNK CF9 COA COJ CGC COB COK CG9 DKB DKK DC9 DKB DKK DC9 DLB DLK DD9 DLB DLK DD9 DMB DMK DE9 DMB DMK DE9 DNB DNK DF9 DNB DNK DF9 DOB DOK DG9 DOB DOK DG9 FKA FKJ FCC FKB FKK FC9 FLA FLJ FDC FLB FLK FD9 FNA FNJ FFC FNB FNK FF9 FOA FOJ FGC FOB FOK FG9 HMJ HMK HMJ HMK HMN HMP HMN HMP N/A N/A HMS HMT HMS HMT HMY HMZ HMY HMZ SPDT 1 HM3 HM4 HA9 HM3 HM4 HA9 DPDT 1 HM7 HM8 HB9 HM7 HM8 HB9 SPDT 1 HKJ HKK HKJ HKK HKN HKP RKB RLB RNB ROB 8KB 8LB 8MB 8NB 8OB 9KB 9LB 9MB 9NB 9OB RKK RLK RNK ROK 8KK 8LK 8MK 8NK 8OK 9KK 9LK 9MK 9NK 9OK N/A DPDT SPDT DPDT SPDT DPDT SPDT DPDT 2 HKN HKP 1 2 1 2 1 2 3 1 2 1 2 3 1 2 RKB RLB RNB ROB 8KA 8LA 8MA 8NA 8OA 9KA 9LA 9MA 9NA 9OA RKK RLK RNK ROK 8KJ 8LJ 8MJ 8NJ 8OJ 9KJ 9LJ 9MJ 9NJ 9OJ RC9 RD9 RF9 RG9 8CC 8DC 8EC 8FC 8GC 9CC 9DC 9EC 9FC 9GC N/A RC9 RD9 RF9 RG9 8C9 8D9 8E9 8F9 8G9 9C9 9D9 9E9 9F9 9G9 Process Cast Iron Cast Iron CS/Aluminum CS/Aluminum Set Temp. Range Contacts Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 Points NEMA 4X NEMA 4X °F (°C) Groups C&D Group B Groups C&D Group B 1 R1M RKM RKW R1M RKM RKW SPDT 2 R3M RLM RLW R3M RLM RLW -40 to +1000 (-40 to +538) 1 RDM RNM RNW RDM RNM RNW DPDT 2 REM ROM ROW REM ROM ROW 1 9AD 9KD 9KV 9AM 9KM 9KW SPDT 2 9BD 9LD 9LV 9BM 9LM 9LW -50 to +1000 3 9CD 9MD 9MV 9CM 9MM 9MW (-46 to +538) 1 9DD 9ND 9NV 9DM 9NM 9NW DPDT 2 9ED 9OD 9OV 9EM 9OM 9OW 23 Q U A L I T Y The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. Magnetrol’s quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product/service quality available. Several Series 3 level switches are available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. E S P Expedite Ship Plan To take advantage of ESP, match the color coded model number codes in the selection charts (standard dimensions apply). W A R R A N T Y All Magnetrol mechanical level and flow controls are warranted free of defects in materials or workmanship for five full years from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products. 5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com 145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306 Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317 Copyright © 2010 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Performance specifications are effective with date of issue and are subject to change without notice. Magnetrol and Magnetrol logotype are registered trademarks of Magnetrol International. Hastelloy® is a registered trademark of Haynes International, Inc. Monel® and Inconel® are registered trademarks of Special Metals Corporation (Formerly Inco Alloys International) CSA logotype is a registered trademark of Canadian Standards Association Carpenter 20 is a registred trademark of Carpenter Technology Corp. Carbo Zinc® 11 is a registered trademark of Carboline Company. Amercote® and Dimetcoat® are registered trademarks of Amercoat Corporation. BULLETIN: 46-123.16 EFFECTIVE: August 2010 SUPERSEDES: June 2009