XP Power JTD2024S15 Dc-dc converter Datasheet

JTD20 Series
DC-DC Converter
20 Watts
xxx Series
• Single and Dual Outputs
• Wide 4:1 Input Range
• 1.6” x 1” Footprint
• -40 °C to +100 °C Operation
• Full Load at 65 °C Ambient
• 3000 VDC Isolation
• Output Trim ±10%
• Remote On/Off
• 3 Year Warranty
Dimensions:
JTD20:
1.6 x 1.0 x 0.41” (40.6 x 25.4 x 10.4 mm)
Models & Ratings
Input
Voltage
9-36V
18-75V
Output
Voltage
Input Current(1)
Output Current
No Load
Full Load
Efficiency
Max. capacitive
load(2)
Model Number
3.3 V
5500 mA
10 mA
850 mA
89.0%
10000 µF
JTD2024S3V3
5V
4000 mA
10 mA
935 mA
89.0%
6800 µF
JTD2024S05
12 V
1670 mA
10 mA
945 mA
88.5%
1000 µF
JTD2024S12
15 V
1330 mA
15 mA
945 mA
88.0%
680 µF
JTD2024S15
±5 V
±2000 mA
10 mA
970 mA
86.0%
±2200 µF
JTD2024D05
±12 V
±835 mA
15 mA
945 mA
88.5%
±470 µF
JTD2024D12
±15 V
±665 mA
15 mA
940 mA
88.5%
±330 µF
JTD2024D15
3.3 V
5500 mA
8 mA
425 mA
89.5%
10000 µF
JTD2048S3V3
5V
4000 mA
8 mA
465 mA
90.0%
6800 µF
JTD2048S05
12 V
1670 mA
8 mA
465 mA
90.0%
1000 µF
JTD2048S12
15 V
1330 mA
8 mA
455 mA
91.0%
680 µF
JTD2048S15
±5 V
±2000 mA
8 mA
480 mA
87.0%
±2200 µF
JTD2048D05
±12 V
±835 mA
8 mA
465 mA
90.0%
±470 µF
JTD2048D12
±15 V
±665 mA
10 mA
460 mA
90.5%
±330 µF
JTD2048D15
Notes
1. Input currents measured at nominal input voltage.
2. Maximum capacitive load is per output.
Mechanical Details
1.00 (25.4)
0.10
(2.54)
0.40
0.40
(10.16) (10.16)
0.41
(10.4)
0.10
(2.54)
0.02
(0.5)
0.40
(10.16)
Dia 0.04 (1.0)
1.60
(40.64)
0.80
(20.32)
Dia 0.04 (1.0)
0.40
(10.16)
Pin Connections
Single
+Vin
-Vin
+Vout
Trim
-Vout
Remote On/Off
Dual
+Vin
-Vin
+Vout
Common
-Vout
Remote On/Off
Notes
0.40
(10.16)
1
Pin
1
2
3
4
5
6
0.40
(10.16)
0.24
(6.0)
0.20
(5.08)
1. All dimensions are in inches (mm)
2. Weight: 0.064 lbs (29.0 g) approx.
3. Pin diameter: 0.04 ±0.002 (1.0 ±0.05)
www.xppower.com
4. Pin pitch tolerance: ±0.014 (±0.35)
5. Case tolerance: ±0.02 (±0.5)
JTD20 Series
DC-DC Converter
Input
Characteristic
Input Voltage Range
Minimum
Units
36
VDC
24 V nominal
18
75
VDC
48 V nominal
50
VDC for 100 ms
24 V models
100
VDC for 100 ms
48 V models
Maximum
Units
Notes & Conditions
30
VDC
See Models and Ratings table
Input Reflected Ripple Current
Typical
Notes & Conditions
Maximum
9
20
mA pk-pk
Input Surge
Through 12 µH inductor and 47 µF capacitor
Output
Characteristic
Minimum
Output Voltage
3.3
Output Trim
±10
Typical
Initial Set Accuracy
Minimum Load
±1
0
%
Single output only, see Application Note
%
At full load
%
No minimum load required
From minimum to maximum input at full load
Line Regulation
±0.5
%
Load Regulation
0.5/1.0
`%
From 0% to full load for single/dual output
%
On dual output models, when one output is at 100% load
and other is varied from 25% load to full load
Cross Regulation
±5
Start Up Time
30
ms
Ripple & Noise
Overload Protection
75/60
mV pk-pk
170
%
Short Circuit Protection
Continuous hiccup mode, with auto recovery
Maximum Capacitive Load
See Models and Ratings table
Temperature Coefficient
Overvoltage Protection
Remote On/Off
Single/Dual Output, Measured using 20 MHz bandwidth and
10 µF/25 V MLCC per output
0.02
%/ ˚C
140
%
Output is on if remote on/off (pin 3) is open or high (3-12 VDC)
Output turns off if remote on/off (pin 3) is low (<1.2 VDC max)
General
Characteristic
Minimum
Efficiency
Maximum
85
Isolation: Input to Output
3000
Isolation: Input and output to Case
1600
Switching Frequency
Isolation Resistance
Typical
%
270/330
2000
Power Density
Mean Time Between Failure
30
400
Weight
See Models and Ratings table
60 s
VDC
60 s
kHz
3V3 & 5 V models/other models
pF
W/in3
kHrs
0.064 (29.0)
Notes & Conditions
VDC
Ω
109
Isolation Capacitance
Units
MIL-HDBK-217F, +25 °C GB
lb (g)
Environmental
Characteristic
Minimum
Operating Temperature
-40
Storage Temperature
-55
Case Temperature
Humidity
Typical
Maximum
Units
Notes & Conditions
+100
°C
See Derating Curve
+125
°C
+105
°C
95
%RH
Cooling
Thermal Impedance to Air
Non-condensing
Natural convection
12
°C/W
www.xppower.com
2
JTD20 Series
DC-DC Converter
EMC: Emissions
Phenomenon
Standard
Test Level
Conducted
EN55032
Class A
Notes & Conditions
No external components required
Radiated
EN55032
Class A
No external components required
EMC: Immunity
Phenomenon
Standard
Test Level
Criteria
ESD Immunity
EN61000-4-2
±6 kV/±8 kV
B
Notes & Conditions
Radiated Immunity
EN61000-4-3
20 Vrms
A
EFT/Burst
EN61000-4-4
2 kV
A
Requires 330 µF/100 V electrolytic and 3 kW TVS
(SMDJ58A for 24 V input, SMDJ120A for 48 V input)
Surge
EN61000-4-5
2 kV
A
Required 330 µF/100 V electrolytic and 3 kW TVS
(SMDJ58A for 24 V input, SMDJ120A for 48 V input)
Conducted Immunity
EN61000-4-6
10 V rms
A
Magnetic Fields
EN61000-4-8
100 A/m
A
Contact Discharge/Air Discharge
Mechanical Details
0.10
(2.54)
1.00 (25.4)
0.40
0.40
(10.16) (10.16)
0.41
(10.4)
0.10
(2.54)
0.02
(0.5)
0.40
(10.16)
Dia 0.04 (1.0)
0.80
(20.32)
1.60
(40.64)
Dia 0.04 (1.0)
0.40
(10.16)
0.40
(10.16)
0.40
(10.16)
Pin Connections
Pin
Single
Dual
1
+Vin
+Vin
2
-Vin
-Vin
3
+Vout
+Vout
4
Trim
Common
5
-Vout
-Vout
6 Remote On/Off Remote On/Off
Notes
1. All dimensions are in inches (mm)
2. Weight: 0.042 lbs (19.0 g) approx.
3. Pin diameter: 0.04±0.002 (1.0 ±0.05)
4. Pin pitch tolerance: ±0.014 (±0.35)
5. Case tolerance: ±0.02 (±0.5)
0.24
(6.0)
0.20
(5.08)
Output Power
Derating Curve
100%
A
75%
Note: Point A is 60 °C for dual 5 V output models
50%
25%
-40
65 80
100
Ambient Temperature (°C)
3
www.xppower.com
JTD20 Series
DC-DC Converter
Application Notes
External Output Trimming
Output can be externally trimmed by using the method as below, (single output models only)
5
5
6
6
Ru
Trim Up
JTD20
Bottom View
4
JTD20
Bottom View
4
2
Trim Down
1
Rd
2
1
3
3
Trim Down Resistor Values (Rd)
Models
3V3
5V
12V
15V
1%
309.0 k
119.9 k
345.0 k
174.4 k
2%
165.4 k
77.70 k
138.1 k
91.10 k
3%
105.6 k
50.50 k
79.90 k
56.60 k
4%
72.9 k
35.2 k
51.5 k
37.7 k
5%
52.3 k
25.3 k
34.6 k
25.8 k
6%
38.0 k
18.4 k
23.4 k
17.6 k
7%
27.6 k
13.4 k
15.5 k
11.6 k
8%
19.7 k
9.50 k
9.50 k
7.00 k
9%
13.5 k
6.40 k
4.90 k
3.50 k
10%
8.40 k
3.90 k
1.26 k
0.55 k
3%
96.40 k
92.80 k
113.6 k
134.0 k
4%
60.8 k
61.1 k
79.9 k
91.0 k
5%
40.8 k
43.8 k
59.5 k
66.8 k
6%
27.9 k
32.9 k
45.8 k
51.3 k
7%
19.0 k
25.4 k
35.9 k
40.4 k
8%
12.4 k
20.0 k
28.5 k
32.5 k
9%
7.30 k
15.8 k
22.7 k
26.4 k
10%
3.40 k
12.5 k
18.1 k
21.5 k
Trim Up Resistor Values (Ru)
Models
3V3
5V
12V
15V
1%
537.7 k
635.2 k
367.4 k
661.5 k
2%
177.1 k
170.0 k
179.6 k
231.3 k
www.xppower.com
22 May 17