Transformers Chassis Mount Features: • • • • • • Single 230 V primary windings Double section metric bobbins Power : 6 to 200 VA, 50 / 60 Hz Temperature class : B (130°C) Dielectric strength : 3,750 Vrms Manufactured and tested in accordance with EN60950 and EN61558 Specifications: Dimensions : Millimetres Maximum winding temperature Overall insulation rating Flash test (isolation test) Winding wire Tape Core Finish : : : : : : : 55°C > 50 MΩ (at 500 V, 20°C) Primary / secondary / lamination 2.4 kVrms Polyurethane coated IEC317 grade 1 3M no 56 or 36M no 1350Y thermosetting 400 / 50 Ultimeg 3.72 clear Dimension Table Dimensions VA Rating Reg% A B C D E 6 24 55 68 37 45 36 12 16 20 12 74 90 50 60 50 9 94 106 65 79 45 52 53 F G H I J K Weight (g) 170 - - - - - - 390 530 985 Dimensions : Millimetres www.element14.com www.farnell.com www.newark.com www.cpc.co.uk <Page 1> 20/12/11 V1.1 Transformers Chassis Mount Dimension Table Dimensions VA Rating Reg% 100 10 150 9 200 8 Tolerance 2 A - B - C - D - E - F G H I J K Weight (g) 45 57 57 89 75 65 1,550 68 72 56 102 85 85 2,750 ±1 approximate Dimensions : Millimetres Specifications Table Output Vac Part Number Transformer, 6 VA, 2 × 5 V 2×5 CTFCS6-5 Transformer, 6 VA, 2 × 6 V 2×6 CTFCS6-6 Transformer, 6 VA, 2 × 9 V 2×9 CTFCS6-9 2 × 12 CTFCS6-12 2 × 15 CTFCS6-15 Transformer, 6 VA, 2 ×18 V 2 × 18 CTFCS6-18 Transformer, 6 VA, 2 × 20 V 2 × 20 CTFCS6-20 Transformer, 6 VA, 2 × 24 V 2 × 24 CTFCS6-24 Transformer, 12 VA, 2 × 6 V 2×6 CTFCS12-6 Transformer, 12 VA, 2 × 9 V 2×9 CTFCS12-9 2 × 12 CTFCS12-12 Transformer, 12 VA, 2 × 20 V 2 × 20 CTFCS12-20 Transformer, 12 VA, 2 × 24 V 2 × 24 CTFCS12-24 Transformer, 20 VA, 2 × 6 V 2×6 CTFCS20-6 Transformer, 20 VA, 2 × 9 V 2×9 CTFCS20-9 Transformer, 20 VA, 2 × 12 V 2 × 12 CTFCS20-12 2 × 15 CTFCS20-15 Transformer, 20 VA, 2 × 18 V 2 × 18 CTFCS20-18 Transformer, 20 VA, 2 × 20 V 2 × 20 CTFCS20-20 Transformer, 20 VA, 2 × 24 V 2 × 24 CTFCS20-24 Transformer, 50 VA, 2 × 6 V 2×6 CTFCS50-6 Transformer, 50 VA, 2 × 12 V 2 × 12 CTFCS50-12 2 × 15 CTFCS50-15 Transformer, 50 VA, 2 × 18 V 2 × 18 CTFCS50-18 Transformer, 50 VA, 2 × 24 V 2 × 24 CTFCS50-24 Description Transformer, 6 VA, 2 × 12 V Transformer, 6 VA, 2 × 15 V Transformer, 12 VA, 2 × 12 V Transformer, 20 VA, 2 × 15 V Transformer, 50 VA, 2 × 15 V VA 6 12 20 50 www.element14.com www.farnell.com www.newark.com www.cpc.co.uk <Page 2> 20/12/11 V1.1 Transformers Chassis Mount Specifications Table Output Vac Part Number Transformer, 100 VA, 2 × 9 V 2×9 CTFCS100-9 Transformer, 100 VA, 2 × 12 V 2 × 12 CTFCS100-12 2 × 18 CTFCS100-18 Transformer, 100 VA, 2 × 24 V 2 × 24 CTFCS100-24 Transformer, 100 VA, 2 ×50 V 2 × 50 CTFCS100-50 Transformer, 150 VA, 2 × 12 V 2 ×12 CTFCS150-12 2 × 18 CTFCS150-18 Transformer, 150 VA, 2 × 24 V 2 × 24 CTFCS150-24 Transformer, 200 VA, 2 × 9 V 2×9 CTFCS200-9 2 × 18 CTFCS200-18 2 × 24 CTFCS200-24 2 × 50 CTFCS200-50 Description Transformer, 100 VA, 2 × 18 V Transformer, 150 VA, 2 × 18 V Transformer, 200 VA, 2 × 18 V Transformer, 200 VA, 2 × 24 V Transformer, 200 VA, 2 × 50 V VA 100 150 200 Important Notice : This data sheet and its contents (the "Information") belong to the members of the Premier Farnell group of companies (the "Group") or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Pro-POWER is the registered trademark of the Group. © Premier Farnell plc 2011. www.element14.com www.farnell.com www.newark.com www.cpc.co.uk <Page 3> 20/12/11 V1.1