ACDC 240 Watts xppower.com DSL240 Series • Ultra Slim Design • 150% Peak Load for 3 seconds • Full Power from 40 °C to +60°C • High Efficiency – Up to 93% • Hazardous Locations Approval • Parallel Capability • 3 Year Warranty Specification Input General 88-264 VAC (120-375 VDC) 47-63 Hz 2.3 A at 115 VAC, 1.15 A at 230 VAC 24/48 A max at 115/230 VAC 0.97 typical at 230 VAC Conforms to EN61000-3-2 Class A. Earth Leakage Current • 3.5 mA maximum Input Protection • Internal fuse in line, T5.0 A/250 VAC Input Voltage Input Frequency Input Current Inrush Current Power Factor • • • • • Efficiency Isolation Switching Frequency DC OK Signal Output LED Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response • • • • • • • • • • Ripple & Noise • Overvoltage Protection • Overload Protection • Short Circuit Protection • Temperature Coefficient Thermal Protection Parallel Operation Maximum Capacitive Load • See table See table +1% at 100% load No minimum load required 1.0 s max 150 ms max 25 ms minimum at full load and 115 VAC ±1% ±1% (±5% in parallel mode) 10% maximum deviation, recovering to less than 1% within 2 ms for 50% step load change at 0.2 A/µs 100 mV pk-pk maximum, measured with 20 MHz bandwidth 12 V output: 15-16.5 V, 24 V output: 30-33 V 120-150% of rated current (see application note) Trip and restart (hiccup mode) auto recovery within 7 s ±0.03%/°C • 110°C max, measured on internal heatsink auto recovery • A maximum of 3 units can be paralleled. Max power available is 90% of total rated power. Minimum load of 10% required per unit • 7000 µF (start up delay increases to 1.5s and rise time to 500 ms) MTBF • See table • 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground • 100 kHz typical PFC & main converter at 230 VAC and full load • Volt free contacts rated at 60 VDC/ 0.3 A on 24 V versions only • Green LED to indicate output on. Red LED to indicate low output voltage. See mechanical details for operating range. • >370 kHrs to BELLCORE Issue 6 at 40 °C, GB Environmental Operating Temperature Cooling Operating Humidity Protection Storage Temperature Operating Altitude Shock Vibration • • • • • • • -40 °C to +70 °C (see derating curves) Natural convection 20-95% RH, non-condensing IP20 -40 °C to +85 °C 4850 m IEC68-2-27, 4 g, 22 ms half sine, 3 times in each of 6 axes • IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep. 60 mins for each of 3 axes EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity • • • • Radiated Immunity EFT/Burst Surge • • • Conducted Immunity Magnetic Field Dips & Interruptions • • • Safety Approvals • EN55022, class B conducted & radiated EN61000-3-2, class A EN61000-3-3 EN61000-4-2, 8 KV Contact, 15 KV Air Discharge, Perf Criteria A EN61000-4-3, 10 V/m Perf Criteria A EN61000-4-4, level 4 Perf Criteria A EN61000-4-5, Installation Class 4 Perf Criteria A EN61000-4-6, 10 V Perf Criteria A EN61000-4-8, level 4, Perf Criteria A EN55024, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B UL508, UL60950-1, EN60950-1, ANSI/ISA 12.12.01 (Class I, Division 2, Groups A, B, C and D) Output Voltage 12 V 24 V Output Power 192 W 240 W Output Voltage Trim(4) 11.75-14.5 V 22.5-28.5 V Output Current 16.0 A 10.0 A Peak Load(3) 24.0 A 15.0 A Typical Efficiency(2) 90% 93% Model Number(1) DSL240PS12-I DSL240PS24-I Notes 1. Add suffix ‘D’ for detachable connector option e.g. DSL240PS24-ID. 2. Typical efficiency at 230 VAC and full load. 3. Peak load is for a maximum of 3 s with 20% duty cycle. Average power is not to exceed nominal output power. 4. Output current should be limited so that nominal output power is not exceeded. Mechanical Details The green LED is lit if the output voltage is OK (10-11.2 VDC for 12 V units, 17.6-19.4 VDC for 24 V units at start up) The red LED is lit if the output voltage is low (10-11.2 VDC for 12 V units, 17.6-19.4 VDC for 24 V units after start up) 6 6 4.59 (116.6) 1 0.3 (7.0) 1 Pin Connections Conn AC Input 5.65 (143.5) 4.9 (124.50) DC Output 1 Pin Designation 1 Ground 2 Neutral 3 Line 1 DC OK* 2 DC OK* 3 Positive 4 Positive 5 Negative 6 Negative 3 1 2.52 (64.0) * 24 V models only. 3 ‘-D’ version (detachable connectors) Notes 1. All dimensions in inches (mm) 2. Weight: 1.916 lbs (860g) 3. Tolerance: ±0.02 in (±0.5 mm) 4. Screw terminal: 10-24 AWG cables size. Detachable connector version: 14-24 AWG cable size. 5. Connection screw maximum torque: Input: 9lbs-in (1.0 Nm), Output: 5.5 lbs-in (0.6 Nm). Application Notes Derating Curves DC OK 100 DCOK Load (%) 80 Open = Output fail Closed = Output good 60 40 DCOK 20 0 -40 -20 0 10 20 30 40 50 60 Contact Rating: 0.3 A at 60 VDC 500 VDC isolation 70 Ambient Temp (˚C) Peak Loading 258 W for 12 V 360 W for 24 V Peak 3 sec 3 sec Auto recovery within 7 sec 198 W for 12 V 240W for 24 V Continuous OCP OCP < 7 sec < 7 sec 04-Jan-13 ACDC DSL240 Models and Ratings