NXJ1 Series www.murata-ps.com Isolated 1W Single Output SM DC/DC Converters Isolation Capacitance % % kHz pF kHrs FEATURES 11.5 75 105 66 69.5 80 2 2430 Patents pending NXJ1S0305MC 3.3 5 400 200 8.5 10 25 45 70 72 90 2.5 3065 NXJ1S0505MC 5 5 250 200 12 13.5 20 50 69 73.5 205 2.5 1988 NXJ1S1205MC 12 5 110 200 6 8.5 22 45 69 72 110 2.5 2244 NXJ1S1212MC 12 12 115 83 4.5 5 15 40 65 71 125 2.5 3473 ANSI/AAMI ES60601-1, 2 MOOP, 1MOPP Recognition pending NXJ1S1215MC 12 15 120 67 4 5 15 40 69 71 135 2.5 3208 4.2kVDC Isolation “Hi Pot Test” INPUT CHARACTERISTICS Lower Profile UL60950 Recognition pending Parameter Substrate Embedded Transformer Automated Manufacture Industry Standard Footprint Short Circuit Protection3 Halogen Free PRODUCT OVERVIEW The NXJ1 series is a new range of low cost, lower profile, fully automated manufacture surface mount DC/DC converters. The NXJ1 series automated manufacturing process with substrate Embedded Transformer, offers increased product reliability and repeatability of performance in a halogen free, iLGA inspectable package. The NXJ1 series, industry standard footprint is compatible with existing designs. Voltage range Input reflected ripple current mVp-p MTTF2 Switching Frequency (Typ) % 10.5 Efficiency (Min) % 333 Output Ripple & Noise (Max) mA 400 Output Ripple & Noise (Typ) mA 3.3 Output Current V 3.3 Output Voltage V NXJ1S0303MC Order Code1 Nominal Input Voltage Efficiency (Typ) Load Regulation (Max) Load Regulation (Typ) Rated Input Current SELECTION GUIDE Conditions Min. Typ. Max. Units Continuous operation, 3V input types Continuous operation, 5V input types Continuous operation, 12V input types 3V input 5V input 12V input 2.97 4.5 10.8 3.3 5.0 12 6 2 2 3.63 5.5 13.2 V Typ. Max. mA p-p ISOLATION CHARACTERISTICS Parameter Conditions Min. Isolation voltage Resistance Flash tested for 1 minute Viso= 1000VDC 4200 10 Units VDC GΩ OUTPUT CHARACTERISTICS Parameter Conditions Rated power Voltage set point accuracy TA=-40°C to 85°C See tolerance envelope Min. Line regulation High VIN to low VIN 0505 variant All other variants Typ. Max. Units 1.0 W 1.15 1.1 1.2 1.2 %/% Typ. Max. Units 85 125 °C TEMPERATURE CHARACTERISTICS The NXJ1 series has a MSL rating 2, and is compatible with a peak reflow solder temperature of 245ÚC as per J-STD-020 and J-STD-075. Parameter Conditions Min. Specification Storage Product temperature rise above ambient Cooling All output types -40 -50 All output types Free air convection 16 ABSOLUTE MAXIMUM RATINGS Input voltage VIN, NXJ1S03 types Input voltage VIN, NXJ1S05 types Input voltage VIN, NXJ1S12 types For full details go to www.murata-ps.com/rohs www.murata-ps.com 5.5V 7V 15V 1. Components are supplied in tape and reel packaging, please refer to package specification section. Orderable part numbers are NXJ1S0505MC-R7 (180 pieces per reel), or NXJ1S0505MC-R13 (800 pieces per reel). 2. Calculated using MIL-HDBK-217 FN2 calculation model with nominal input voltage at full load. 3. Please refer to short circuit application notes. All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. All enquiries: www.murata-ps.com/support KDC_NXJ1.A01 Page 1 of 10 NXJ1 Series Isolated 1W Single Output SM DC/DC Converters TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NXJ1 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 4.2kVDC for 1 minute. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” For a part holding no specific agency approvals, such as the NXJ1 series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NXJ1 series has a PCB embedded isolated transformer, using FR4 as an insolation barrier between primary and secondary windings. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the FR4 insulation properties. Any material, including FR4 is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage should be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL ANSI/AAMI ES60601-1 The NXJ1 series is pending recognition by Underwriters Laboratory (UL) to meet ANSI/AAMI ES60601-1 medical safety standard providing the following MOOP (Means Of Operator Protection), and MOPP (Means Of Patient Protection). 2 MOOP and 1 MOPP based upon a working voltage of 200Vrms. UL 60950 The NXJ1 series is pending recognition by Underwriters Laboratory (UL) to UL 60950 for reinforced insulation to a working voltage of 200Vrms. FUSING The NXJ1 Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as defined below. Input Voltage, 3.3V: 1A Input Voltage, 5V: 0.5A Input Voltage, 12V: 0.25A All fuses should be UL recognized and rated to at least the maximum allowable DC input voltage. www.murata-ps.com All enquiries: www.murata-ps.com/support KDC_NXJ1.A01 Page 2 of 10 NXJ1 Series Isolated 1W Single Output SM DC/DC Converters CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter 10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less C2 than 100mΩ at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450Ω resistor, carbon film, ±1% tolerance R2 50Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. Differential Mode Noise Test Schematic DC/DC Converter OSCILLOSCOPE C1 C2 C3 + SUPPLY Input - R1 + T1 R2 Y INPUT Output - R LOAD RoHS COMPLIANCE, MSL AND PSL INFORMATION This series is compatible with Pb-Free soldering systems and is also backward compatible with Sn/Pb soldering systems. The NXJ1 series has a process, moisture, and reflow sensitivity classification of MSL2 PSL R7F as defined in J-STD-020 and J-STD-075. This translates to: MSL2 = 1 year floor life, PSL R7F = Peak reflow temperature 245°C with a limitation on the time above liquidus (217°C) which for this series is 90sec max. The pin termination finish on this product series is Gold with a plating thickness of 0.12 microns. www.murata-ps.com All enquiries: www.murata-ps.com/support KDC_NXJ1.A01 Page 3 of 10 NXJ1 Series Isolated 1W Single Output SM DC/DC Converters TOLERANCE ENVELOPES The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading. NXJ1S0303MC NXJ1S0305MC 8% 5% 0% -5% 1% Output Voltage Output Voltage 4% -5% -10% 10 25 50 75 100 25 10 50 75 100 Output Load Current (%) Output Load Current (%) NXJ1S0505MC NXJ1S1205MC 9% 4% -2% Output Voltage Output Voltage 6% 0% -1% -4% -8% 10 25 75 50 Output Load Current (%) 100 10 NXJ1S1212MC 25 75 50 Output Load Current (%) 100 NXJ1S1215MC 6% 4% Output Voltage 2% -2% 10 25 www.murata-ps.com 75 50 Output Load Current (%) 100 Output Voltage 3% 0% 0% -3% 10 25 75 50 Output Load Current (%) 100 All enquiries: www.murata-ps.com/support KDC_NXJ1.A01 Page 4 of 10 NXJ1 Series Isolated 1W Single Output SM DC/DC Converters EFFICIENCY VS LOAD 3V Input 80 70 Efficiency (%) 60 50 NXJ1S0303MC 40 NXJ1S0305MC 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Load (%) 5V Input 80 70 Efficiency (%) 60 50 NXJ1S0505MC 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Load (%) 12V Input 80 70 Efficiency (%) 60 50 NXJ1S1205MC 40 NXJ1S1212MC NXJ1S1215MC 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Load (%) www.murata-ps.com All enquiries: www.murata-ps.com/support KDC_NXJ1.A01 Page 5 of 10 NXJ1 Series Isolated 1W Single Output SM DC/DC Converters TEMPERATURE DERATING The derating graphs are based on the following airflow conditions, for a component mounted on a 25mm x 25mm copper covered pcb and are provided for information only. Actual performance in an application is likely to differ from these results, and a customer should evaluate the thermal environment the NXJ1 is used in, to achieve a recommended maximum component surface temperature of 85°C for the NXJ1S0303SC or 105°C for all other variants. NXJ1S0305MC 1 1 0.8 0.8 still air 0.6 100 lfm 200 lfm 0.4 Power (W) Power (W) NXJ1S0303MC still air 0.6 100 lfm 200 lfm 0.4 400 lfm 400 lfm 0.2 0.2 0 0 50 60 70 80 50 Ambient Temperature (°C) NXJ1S0505MC NXJ1S1205MC 1 1 still air 0.6 100 lfm 200 lfm 0.4 400 lfm Power (W) Power (W) 70 80 0.8 0.8 still air 0.6 100 lfm 200 lfm 0.4 400 lfm 0.2 0.2 0 0 50 60 70 50 80 Ambient Temperature (°C) 60 70 80 Ambient Temperature (°C) NXJ1S1212MC NXJ1S1215MC 1 1 0.8 still air 0.6 100 lfm 200 lfm 0.4 400 lfm Power (W) 0.8 Power (W) 60 Ambient Temperature (°C) still air 0.6 100 lfm 200 lfm 0.4 400 lfm 0.2 0.2 0 0 50 60 70 Ambient Temperature (°C) www.murata-ps.com 80 50 60 70 80 Ambient Temperature (°C) All enquiries: www.murata-ps.com/support KDC_NXJ1.A01 Page 6 of 10 NXJ1 Series Isolated 1W Single Output SM DC/DC Converters APPLICATION NOTES Short Circuit Performance NXJ1 short circuit protection is not continuous and varies with output voltage and temperature as shown in the following graph: 1000 100 Time (s) NXJ1S0303MC NXJ1S0305MC 10 NXJ1S0505MC NXJ1S1205MC NXJ1S1212MC 1 NXJ1S1215MC 0.1 25 35 45 55 65 75 Ta (°C) Advisory Notes Minimum Load The NXJ1 series is not hermetically sealed, customers should ensure that parts are fully dried before input power application. The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%. Capacitive Loading & Start Up Typical start up times for this series, with a typical input voltage rise time of 2.2μs with resistive only load, and with added output capacitance of 47μF, are shown in the table below. Typical Start-Up Wave Form Resistive Load and Resistive Load 47μF Part Number Start-up time (μS) NXJ1S0303MC 40 190 NXJ1S0305MC 95 1700 NXJ1S0505MC 50 1100 NXJ1S1205MC 35 600 NXJ1S1212MC 80 2650 NXJ1S1215MC 100 4000 Output Ripple Reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. Component selection Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended. The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter. Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be >20MHz. L, μH NXJ1S0303MC NXJ1S0305MC NXJ1S0505MC NXJ1S1205MC NXJ1S1212MC NXJ1S1215MC www.murata-ps.com Inductor SMD Through Hole Capacitor C, μF L Power Source DC C Load DC All enquiries: www.murata-ps.com/support KDC_NXJ1.A01 Page 7 of 10 NXJ1 Series Isolated 1W Single Output SM DC/DC Converters EMC FILTERING AND SPECTRA FILTERING The module includes a basic level of filtering. The following plots show typical spectra with EN 55022 Curve A Quasi-Peak EMC limit, with the addition of an input capacitor of 2.2μF and input inductor of 22μH. 0305 80 80 70 70 60 60 50 50 dBuV dBuV 0303 40 40 30 30 20 20 10 10 0 1.00E+05 1.00E+06 1.00E+07 0 1.00E+05 1.00E+08 1.00E+06 Frequency (Hz) 80 80 70 70 60 60 50 50 40 30 20 20 10 10 1.00E+07 0 1.00E+05 1.00E+08 1.00E+06 Frequency (Hz) 70 60 60 50 50 dBuV dBuV 80 70 40 30 20 20 10 10 www.murata-ps.com 1.00E+08 40 30 1.00E+07 Frequency (Hz) 1.00E+07 1215 80 1.00E+06 1.00E+08 Frequency (Hz) 1212 0 1.00E+05 1.00E+07 40 30 1.00E+06 1.00E+08 1205 dBuV dBuV 0505 0 1.00E+05 1.00E+07 Frequency (Hz) 1.00E+08 0 1.00E+05 1.00E+06 Frequency (Hz) All enquiries: www.murata-ps.com/support KDC_NXJ1.A01 Page 8 of 10 NXJ1 Series Isolated 1W Single Output SM DC/DC Converters PACKAGE SPECIFICATIONS Mechanical Dimensions Pin Connections 13.72 [0.540] (8.13 [0.320]) SMA PICKUP POINT Pin Function 1 3 7 8 14 -Vin +Vin -Vout +Vout NC NC - No connection. Dimension Information S # SEATING PLANE SMA PICKUP POINT (TOP OF PCB) 3.11±0.19 [0.122±0.007] 0.1 (0.004) 2.54 [0.100] S x5 PINS Variant Dim # NXJ1S0303MC NXJ1S0305MC NXJ1S0505MC NXJ1S1205MC NXJ1S1212MC NXJ1S1215MC 4.36±0.35mm [0.172±0.014] 4.16±0.35mm [0.164±0.014] All dimensions in mm(inches), Controlling dimension is mm. Tolerances (unless otherwise stated) ±0.25(0.010). 1 3 7 10.46 [0.412] 14 8 1.52 [0.060] x 5 PLACES 0.61 [0.024] 7.62 [0.300] 3.05 [0.120] All dimensions in mm(inches), Controlling dimension is mm. Tolerances (unless otherwise stated) ±0.25 (0.010). Weight: 1.12g Recommended Footprint Details 7.62 [0.300] x5 PLACES 2.30 [0.091] 9.40 [0.370] RECOMMENDED ISOLATION BARRIER x5 PLACES 1.00 [0.039] www.murata-ps.com 2.54 [0.100] All enquiries: www.murata-ps.com/support KDC_NXJ1.A01 Page 9 of 10 NXJ1 Series Isolated 1W Single Output SM DC/DC Converters TAPE & REEL SPECIFICATIONS REEL OUTLINE DIMENSIONS REEL PACKAGING DETAILS 30.4 [1.197] MAX# Ø332 [13.071] MAX OR Ø180 [7.087] MAX [ +0.020 Ø13.0 +0.5 -0.2 Ø0.512 -0.008 ] GOODS ENCLOSURE SECTION LEADER SECTION 400 [15.748] MIN TRAILER SECTION 160 [6.299] MIN 100 [3.937] MIN 1.5 [0.059] MIN ## Ø20.2 [Ø0.795] MIN Carrier tape pockets shown are illustrative only - Refer to carrier tape diagram for actual pocket details. Tape & Reel specifications shall conform with current EIA-481 standard Unless otherwise stated all dimensions in mm(inches) Controlling dimension is mm # Measured at hub ## Six equi-spaced slots on 180mm/7” reel Reel Quantity: 7” - 180 or 13” - 800 TAPE OUTLINE DIMENSIONS 2.0 [0.079] Ø1.5 [Ø0.059] MIN 1.75 [0.069] [ +0.004 +0.10 Ø1.5 -0.00 Ø0.059 -0.000 [ 4.0 [0.157] 11.5 [0.453] 22.25 [0.876] MIN 24.3 [0.957] MAX 14.3 [0.563]# COVER TAPE 3° MAX 0.6 [0.024] MAX 11.0 [0.433]# 5.0 [0.197] 16.0 [0.630] DIRECTION OF UNREELING Tape & Reel specifications shall conform with current EIA-481 standard Unless otherwise stated all dimensions in mm(inches) ±0.1mm (±0.004 Inches) Controlling dimension is mm Components shall be orientated within the carrier tape as indicated # Measured on a plane 0.3mm above the bottom pocket Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED www.murata-ps.com/support This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2015 Murata Power Solutions, Inc. All enquiries: www.murata-ps.com/support KDC_NXJ1.A01 Page 10 of 10