Systemsensor CZ-6 Multiple input and output module Datasheet

500 Series
Multiple Input and Output
Modules
System Sensor multiple input and output modules
are designed to meet a range of applications in which
numerous single modules are used.
Features
• Removable 12 to 18 AWG plug-in terminal blocks
• Individual LED indicators
• Unused addresses may be disabled
• Rotary address switches
• Class A or B operation
• Mount up to two modules in BB-2 enclosure (optional)
• Mount up to six modules in BB-6 enclosure with CH-6 chassis
(optional)
• Mounting hardware included
The design of the System Sensor 500 Series multiple input and output
modules allows for installation ease and time savings The monitor and control
modules can be used to supervise and activate sounders, strobes, door
closers, pull stations, waterflow switches, conventional smoke detectors and
more. The conventional zone interface module is ideal for retrofit applications
to monitor zones of conventional two-wire detectors. Each module has its
own address. Modules are addressed with easy-to-use rotary code switches.
Provisions are included for disabling unused addresses. Up to two modules
mount in a BB-2 enclosure with built-in chassis and up to six modules
mount in a BB-6 enclosure with the CH-6 chassis. Wiring terminals are easily
accessible for trouble-shooting purposes.
CR-6 SIX RELAY CONTROL MODULE
The CR-6 Six Relay Control module consists of six Form-C relays. The first
address is set from 01 to 94, while the remaining modules are automatically
assigned to the next five higher addresses. Provisions are included for
disabling a maximum of three unused addresses. A single isolated set of
dry relay contacts is provided for each module address which is capable of
being wired for either a normally open or normally closed operation. The
module allows the control panel to switch these contacts on command. No
supervision is provided for the controlled circuit.
SC-6 SIX SUPERVISED CONTROL MODULE
The SC-6 Six Supervised Control module provides supervised monitoring
of wiring to load devices that require an external power supply or amplifier
to operate, such as horns, strobes, speakers or bells. Upon command from
the control panel, the SC-6 will disconnect the supervision and connect the
external power supply across the load device. The first module is addressed
from 01 to 94, while the remaining modules are assigned to the next five
higher addresses. Provisions are included for disabling a maximum of three
unused modules. Each module has terminals for connection to an external
supply circuit for powering devices on its notification appliance circuit. One
or multiple power supplies or amplifiers may be used.
There is a short circuit protection monitor for each module. This is provided
to protect the external power supply against short circuit conditions on the
NAC. When an alarm condition occurs, the relay which connects the external
continued
continued
supply to the NAC will not be allowed to close if a short circuit condition
currently exists on the NAC. In addition, an algorithm is incorporated to find a
short when the module is active. The module will close all circuits that are not
shorted to find the NAC with the problem.
SYNC-1 ACCESSORY CARD
The SYNC-1 is an optional accessory to the SC-6 and is designed to provide
a means of synchronizing a series of horns, strobes, and horn/strobes. The
SYNC-1 is able to synchronize the temporal-coded horns, the one second
flash timing of the strobe, and silencing the horns of the horn/strobe
combination over a two-wire circuit while leaving the strobes active. Each
SYNC-1 accessory card has the capability of synchronizing six Class B circuits
or three Class A circuits.
CZ-6 SIX ZONE INTERFACE MODULE
The CZ-6 Six Zone Interface module provides an interface between the
intelligent alarm system and a two-wire conventional detection zone. A
common SLC input is used for all modules, and the initiating device circuits
share a common external supply. Otherwise, each module operates
independently from the others. The first module is addressed from 01 to 94
while the remaining modules are assigned to the next five higher addresses.
Provisions are included for disabling a maximum of two unused modules.
All two-wire detectors being monitored must be two-wire compatibility
listed with the modules. The CZ-6 transmits the status of a zone of two-wire
detectors to the fire alarm control panel. Status conditions are reported as
normal, open or alarm. The interface module supervises the zone of detectors
and the connection of the external power supply.
IM-10 TEN INPUT MONITOR MODULE
The IM-10 Ten Input Monitor module provides an interface between a
control panel and normally open contact devices such as pull stations,
security contacts, or flow switches. The first address is set from 01 to 90 and
the remaining modules are automatically assigned to the next nine higher
addresses. Provisions are included for disabling a maximum of two unused
addresses. The supervised state (normal, open or short) of the monitored
device is sent back to the panel.
500 Series Module Specifications
General Specifications
Operating Voltage
Maximum SLC Wiring Resistance
Temperature Range
Relative Humidity
Wire Gauge
Dimensions
Specifications: CR-6
Standby Current
Alarm Current
15 to 32 VDC
40 Ohms
32°F to 120°F (0° to 49°C)
10% to 85% noncondensing
12 to 18 AWG
6.8˝H × 5.8˝W × 1.25˝D
1.45 mA maximum
32 mA maximum (assumes all six relays
have been switched once and all six
LEDs solid on)
Maximum IDC Wiring Resistance 40 Ohms
Relay Current
30 mA/Relay Pulse (15.6 mS pulse
duration) pulse under panel control
Relay Contact Ratings
30 VDC; 70.7 VAC
Specifications: CZ-6
Standby Current
2 mA maximum
Alarm Current
40 mA maximum (assumes all six LEDs
solid on)
Maximum IDC Wiring Resistance 25 Ohms
External Supply Voltage
DC Voltage: 18 to 28 volts power
limited
Ripple Voltage: 0.1 volts RMS maximum
Current: 90 mA per circuit
Compatible Detectors
Contact System Sensor for a current list
Specifications: SC-6
Standby Current
2.25 mA maximum
Alarm Current
35 mA maximum (assumes all six relays
have been switched once and all six
LEDs solid on)
Maximum NAC Circuit Wiring
40 Ohms
Resistance
Power Rating Per Circuit
63 W @ 70.7 VAC
Relay Contact Ratings
30 VDC; 110 VAC
Specifications: IM-10
Standby Current
Alarm Current
3.5 mA maximum
60 mA maximum (assumes all ten LEDs
solid on)
Maximum IDC Wiring Resistance 40 Ohms
Maximum IDC Voltage
12 VDC
Maximum IDC Current
1 mA
Accessories
SYNC-1 Accessory Card
BB-6 Enclosure with CH-6 Chassis
Specifications: SYNC-1
Operating Voltage
Maximum Load on a Loop
Standby Current
Specifications: BB-2 Enclosure
Dimensions
Specifications: BB-6 Enclosure
Dimensions
3825 Ohio Avenue • St. Charles, IL 60174
Phone: 800-SENSOR2 • Fax: 630-377-6495
11 to 30 VDC
Class A/Style Z: 3A
Class A/Style Y: 3A per pair
+0 Position: 15 mA
+2 or +4 Position if connected to
supply: 2.5 mA
12˝H × 9˝W × 3.67˝D
24˝H × 12.55˝W × 6.47˝D
©2008 System Sensor.
Product specifications subject to change without notice. Visit systemsensor.com for
current product information, including the latest version of this data sheet.
A05-0344-003 • 1/09 • #2088