Mini-spectrometers TG series C11713CA C11714CB For Raman spectrophotometry, high resolution type (spectral resolution: 0.3 nm) The C11713CA and C11714CB are polychromators integrated with optical elements, an image sensor and a driver circuit. Light to be measured is guided into the entrance port of TG series through an optical fiber and the spectrum measured with the built-in image sensor is output from the USB port to a PC for data acquisition. The C11713CA has sensitivity in a wavelength range of 500 to 600 nm, while the C11714CB covers a range of 790 to 920 nm. Both types offer a spectral resolution of 0.3 nm. Their products come supplied with free evaluation software that allows setting measurement conditions, acquiring and saving data, and displaying graphs. Original measurement software can be designed on an end-user’s side as DLL’s function specification is disclosed. Features Applications High accuracy optical characteristics: spectral resolution 0.3 nm Raman spectrophotometry Easy to install into equipment due to compact design High throughput due to transmission grating made of quartz Wavelength conversion factor is recorded in internal memory *1 *1: A conversion factor for converting the image sensor pixel number into a wavelength is recorded in the module. A calculation factor for converting the A/D converted count into the input light intensity is not provided. Selection guide (Typ.) Parameter Spectral response range Spectral resolutiion Built-in image sensor C11713CA 500 to 600 C11714CB 790 to 920 Unit nm nm 0.3 IR-enhanced back-thinned CCD image sensor Back-thinned CCD image sensor - High sensitivity in near infrared region (C11714CB) Spectral response Using a CCD image sensor with enhanced near infrared sensitivity, the C11714CB offers higher sensitivity than that of the previous product. (Typ. Ta=25 °C) 100 90 Relative photosensitivity (%) C11714CB 80 70 Previous product 60 50 40 30 20 10 0 750 800 850 900 950 Wavelength (nm) KACCB0371EA www.hamamatsu.com 1 TG series Mini-spectrometers C11713CA, C11714CB Structure Parameter Dimensions (W × D × H) Weight Image sensor Number of pixels Slit*2 (H × V) NA*3 Connector for optical fiber A/D conversion Interface External power supply (AC adapter) C11713CA C11714CB 120 × 70 × 60 592 Back-thinned type CCD image sensor IR-enhanced back-thinned CCD image sensor (S10420-1106-01) (S11510-1006) 2048 1024 10 × 1000 0.11 SMA905D 16 USB 1.1 AC 100V-240V, 50/60Hz Unit mm g pixels μm bit °C *2: Entrance slit aperture size *3: Numeric aperture (solid angle) Absolute maximum ratings Parameter External power supply voltage Operating temperature*4 Storage temperature*4 Value 5.25 +5 to +40 -20 to +70 Unit V °C °C *4: No dew condensation When there is a temperature difference between a product and the surrounding area in high humidity environment, dew condensation may occur on the product surface. Dew condensation on the product may cause deterioration in characteristics and reliability. Note: Exceeding the absolute maximum ratings even momentarily may cause a drop in product quality. Always be sure to use the product within the absolute maximum ratings. Electrical characteristics (Ta=25 °C, unless otherwise noted) Parameter Integration time Consumption current of USB bus power*5 External power supply voltage Consumption current of external power supply*5 Min. - Typ. 10 to 10000 5 - Max. Unit ms mA V A 150 0.8 *5: When operated with the supplied evaluation software (at default settings, dark state, excluding start-up). Electrical and optical characteristics (Ta=25 °C, unless otherwise noted) Parameter Spectral response range Spectral resolution (FWHM)*6 Wavelength reproducibility*7 Wavelength temperature dependence Spectral stray light*6 *8 Min. - - C11713CA Typ. 500 to 600 0.3 -0.1 to +0.1 -0.04 to +0.04 - Max. Min. 0.5 - -30 - C11714CB Typ. 790 to 920 0.3 -0.1 to +0.1 -0.04 to +0.04 - Max. 0.5 -30 Unit nm nm nm nm/°C dB *6: Depends on the slit opening. Values were measured with the slit listed in the table “ Structure”. *7: Measured under constant light input conditions *8: When monochromatic light of the following wavelengths is input, spectral stray light is defined as the ratio of the count measured at the input wavelength, to the count measured in a region of the input wavelength ±10 nm C11713CA: 550 nm, C11714CB: 860 nm 2 TG series Mini-spectrometers C11713CA, C11714CB Spectral response (typical example) C11713CA C11714CB (Typ. Ta=25 °C) 90 90 80 80 70 60 50 40 30 70 60 50 40 30 20 20 10 10 0 450 500 550 600 (Typ. Ta=25 °C) 100 Relative sensitivity (%) Relative sensitivity (%) 100 0 750 650 800 850 900 950 Wavelength (nm) Wavelength (nm) KACCB0240EA KACCB0372EA Spectral resolution vs. wavelength C11713CA C11714CB (Typ. Ta=25 °C) 0.5 0.4 Spectral resolution (nm) Spectral resolution (nm) 0.4 0.3 0.2 0.1 0 450 (Typ. Ta=25 °C) 0.5 0.3 0.2 0.1 500 550 600 650 0 750 800 850 900 950 Wavelength (nm) Wavelength (nm) KACCB0224EA KACCB0373EA 3 TG series Mini-spectrometers C11713CA, C11714CB Linearity (typical example) Typical example of A/D output Ideal value of A/D output Difference between ideal value and typical example 8 6 10000 4 A/D output 2 0 1000 -2 -4 100 -6 -8 10 10 100 -10 10000 1000 100000 10 Typical example of A/D output Ideal value of A/D output Difference between ideal value and typical example 8 6 10000 4 A/D output 10 100000 Difference between ideal value and typical example (%) C11714CB Difference between ideal value and typical example (%) C11713CA 2 1000 0 -2 -4 100 -6 -8 10 10 100 -10 10000 1000 Integration time (ms) Integration time (ms) KACCB0235EA KACCB0374EA A/D output is the output with dark output is subtracted when light is input. The difference between the ideal value and typical example contains a measurement error. The smaller the A/D output, the larger the measurement error. Dark output vs. ambient temperature (typical example) C11713CA (Integration time 1 s) 60000 50000 40000 30000 20000 10000 (Integration time 1 s) 70000 A/D output (averaged over all pixels) 70000 A/D output (averaged over all pixels) C11714CB 60000 50000 40000 30000 20000 10000 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Ambient temperature (°C) Ambient temperature (°C) KACCB0237EA KACCB0375EA A/D output is the sum of the sensor and circuit offset outputs and the sensor dark output. 4 Mini-spectrometers TG series C11713CA, C11714CB Connection example (transmission light measurement) Light to be measured is guided into the entrance port of TG series through an optical fiber and the spectrum measured with the built-in image sensor is output through the USB port to a PC for data acquisition. There are no moving parts inside the unit so stable measurements are obtained at all times. An optical fiber that guides light input from external sources allows a flexible measurement setup. AC adapter Minispectrometer PC USB cable Exciting LD light source Fiber Raman probe Measuring cell KACCC0577EB Optical component layout TG series mini-spectrometers use a transmission holographic grating made of quartz and precision optical components arranged on a rugged optical base, making it possible to deliver high throughput and highly accurate optical characteristics. Focus lens Transmission grating Image sensor Collimating lens Input slit KACCC0256EA 5 TG series Mini-spectrometers C11713CA, C11714CB Measurement example Raman spectrophotometry using nophthalene (C11714CB) 14000 (Pump laser 785 nm/60 mW, connection fiber 200 μm core dia., integration time 5 s) 12000 A/D counts 10000 8000 6000 4000 2000 0 790 800 820 840 860 880 900 920 Wavelength (nm) KACCB0229EA Evaluation software package (supplied with unit) Installing the evaluation software package (Spec Evaluation.exe)*8 into your PC allows running the following basic tasks: · Measurement data acquisition and save · Measurement condition setup · Module information acquisition (wavelength conversion factor, polychromator type, etc.) · Graphic display · Arithmetic operation Pixel number to wavelength conversion Comparison calculation with reference data (transmittance, reflectance) Dark subtraction Gaussian approximation (peak position and count, FWHM) Note: · Two or more mini-spectrometers can be connected and used with one PC simultaneously. · The external trigger input function does not work with the evaluation software. If using an external trigger input or designing original application software, the user software must be configured to support that function. *8: Compatible OS: Microsoft® Windows® 7 Professional SP1 (32-bit, 64-bit) Microsoft® Windows® 8 Professional (32-bit, 64-bit) DLL for controlling hardware is also provided. You can develop your own measurement programs by using a following software development environment. Microsoft® Visual Studio® 2008 (SP1) Visual C++® Microsoft® Visual Studio® 2008 (SP1) Visual Basic® Note: Microsoft, Windows, Visual Studio, Visual C++ and Visual Basic are either registerd trademarks or trademarks of Microsoft Corporation in the United States and other countries. 6 TG series Mini-spectrometers C11713CA, C11714CB Dimensional outline (unit: mm, tolerance unless otherwise noted: ±0.5) 120.0 50.0 ± 0.2 60.0 70.0 (4 ×) M3.0 tap depth 5 (from backside) 110.0 ± 0.2 Weight: 592 g KACCA0281EB Accessories · USB cable · Dedicated software (evaluation software, sample software, DLL) · AC adapter (for power supply) Options (sold separately) · Coaxial cable for external trigger input A10670 · Optical fibers for light input Type no. Product name Fiber for visible/near infrared range A9763-01 Core diameter (μm) Specification 600 NA=0.22, length 1.5 m, connectorized SMA905D at both ends ϕ14.5 Dimensional outline (A10670, unit: mm) ϕ6.4 Cable length: 1.5 m Cable specification: 1.5QEV 26.0 LEMO connector FFA.00.250 (made by LEMO) 31.7 BNC connector BNC-P-1.5 (40) (made by HIROSE or equivalent) KACCA0220EB 7 TG series Mini-spectrometers C11713CA, C11714CB Mini-spectrometer/micro-spectrometer lineup Type no. Type TM-UV/VIS-CCD High sensitivity C10082CAH TM-UV/VIS-CCD High resolution C10082MD C10083CA C10083CAH Mini-spectrometer TM series C10082CA TM-VIS/NIR-MOS-II Trigger-compatible Mini-spectrometer TG series TG-UV-CCD High resolution C11482GA Non-cooled type C13053MA C13054MA C11007MA C11008MA Back-thinned CCD image sensor CMOS linear image sensor 3 200 to 400 1* 500 to 1100 500 to 600 790 to 920 Back-thinned CCD image sensor 5 (λ=550 to 900 nm) IR-enhanced back-thinned CCD image sensor 0.3* Back-thinned CCD image sensor 0.3* IR-enhanced back-thinned CCD image sensor Mini-spectrometer TG series TG2-NIR Mini-spectrometer Mini-spectrometer RC series FT series C11118GA Image sensor 8 (λ=320 to 900 nm) Back-thinned CCD image sensor 1* (λ=320 to 900 nm) CMOS linear 8 image sensor High-sensitivity CMOS 8 linear image sensor 320 to 1000 TG-RAMAN-I High resolution TG-RAMAN-II High resolution C9914GB 1* 6 TG-SWNIR-CCD-II IR-enhanced C11714CB C9913GC 200 to 800 TG-UV-CCD High sensitivity C9404CA Spectral resolution max. (nm) 6 TM-VIS/NIR-CCD High resolution C11697MB C11713CA Spectral response range (nm) 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 600 TM-VIS/NIR-CCD High sensitivity TM-VIS/NIR-MOS Wide dynamic range C9405CB 400 TM-UV/VIS-MOS Wide dynamic range C10083MD C9404CAH 200 7 900 to 1700 TG-cooled NIR-I Low noise (cooled type) 7 TG-cooled NIR-II Low noise (cooled type) 1100 to 2200 TG-cooled NIR-III Low noise (cooled type) 900 to 2550 FT-SWIR-MOS-II 500 to 1100 Compact, thin case FT2-RAMAN 790 to 920 Compact, thin case RC-VIS-MOS 340 to 780 Spectrometer module RC-SWNIR-MOS 640 to 1050 Spectrometer module 8 InGaAs linear image sensor 20 0.4* High-sensitivity CMOS linear image sensor 9 CMOS linear image sensor 8 IR-enhanced CMOS linear image sensor Spectral resolution max. (nm) Image sensor 9 CMOS linear image sensor 8 IR-enhanced CMOS linear image sensor Spectral resolution max. (nm) Image sensor 20 CMOS linear image sensor 15 CMOS linear image sensor 15 High-sensitivity CMOS linear image sensor 3.5 * Typ. For installation into mobile measuring equipment C11009MA C11010MA Type Mini-spectrometer RC series Type no. 200 RC-VIS-MOS 400 Spectral response range (nm) 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 600 340 to 780 Spectrometer head RC-SWNIR-MOS 640 to 1050 Spectrometer head For installation into mobile measuring equipment (ultra-compact) C11708MA C12666MA C12880MA Type MicroMini-spectrometer spectrometer MS series Type no. MS-SWNIR-MOS Spectrometer head Spectrometer head Spectrometer head 200 400 600 Spectral response range (nm) 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 640 to 1050 340 to 780 340 to 850 8 Mini-spectrometers TG series C11713CA, C11714CB Related information www.hamamatsu.com/sp/ssd/doc_en.html Precautions · Disclamer · Mini-spectrometers Technical information · Mini-spectrometers Information described in this material is current as of October, 2015. Product specifications are subject to change without prior notice due to improvements or other reasons. This document has been carefully prepared and the information contained is believed to be accurate. In rare cases, however, there may be inaccuracies such as text errors. Before using these products, always contact us for the delivery specification sheet to check the latest specifications. The product warranty is valid for one year after delivery and is limited to product repair or replacement for defects discovered and reported to us within that one year period. However, even if within the warranty period we accept absolutely no liability for any loss caused by natural disasters or improper product use. Copying or reprinting the contents described in this material in whole or in part is prohibited without our prior permission. www.hamamatsu.com HAMAMATSU PHOTONICS K.K., Solid State Division 1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184 U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, N.J. 08807, U.S.A., Telephone: (1) 908-231-0960, Fax: (1) 908-231-1218 Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 8152-375-0, Fax: (49) 8152-265-8 France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10 United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777 North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 16440 Kista, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01 Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6, 20020 Arese (Milano), Italy, Telephone: (39) 02-93581733, Fax: (39) 02-93581741 China: Hamamatsu Photonics (China) Co., Ltd.: B1201, Jiaming Center, No.27 Dongsanhuan Beilu, Chaoyang District, Beijing 100020, China, Telephone: (86) 10-6586-6006, Fax: (86) 10-6586-2866 Cat. No. KACC1225E02 Oct. 2015 DN 9