MACOM HF393 Signal and rf relay Datasheet

HF3 Relay
108-98000
Sept 06 Rev. C
ECOC: JM10
AXICOM
Telecom-, Signal and RF Relays
108-98000 Rev. C
HF3 Relay
Index
UL 508
UL 60950
File No. E 111441
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Dimensions
Coil Operating Range
Coil Data and Ordering Informations
Contact Data
Insulation
General Data
Packing
4
5
6
7
7
7
10
of 12
AXICOM
Telecom-, Signal and RF Relays
108-98000 Rev. C
HF3 Relay
High performance low cost plastic sealed high frequency
relay for 50 and 75 Ohm systems, 1 pole, polarized coil
Surface Mount Technology (SMT)
Relay types:
non latching
latching 1 coil
latching 2 coils
ROHS compliant (Directive 2002/95/EC) all date codes.
Features
•
•
•
•
•
•
•
Y-Design
Frequency range DC to 3 GHz
Impendance 50 Ω or 75 Ω
Small dimensions (14.6 mm x 7.2 mm x 10 mm)
1 change over contact (1 form C / SPDT)
Immersion cleanable
Low power consumption (≤140 mW)
Typical applications
•
•
•
•
•
Cable modems and linecards/ CATV
TAP's
Measurement and test equipment ATE
Satellite / audio / video tuners
Wireless base stations and antennas
All specifications subject to change. Consult Tyco Electronics for latest specifications.
of 12
AXICOM
Telecom-, Signal and RF Relays
108-98000 Rev. C
HF3 Relay
Dimensions
50 Ohm Version
AXICOM CZECH
HF3 27
24V DC 10640
Dimensions in mm
75 Ohm Version
AXICOM CZECH
HF3 27
24V DC 10640
Solder pad layout View onto the component side of the PCB (Top view)
50 Ohm Version
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Dimensions in mm
75 Ohm Version
of 12
AXICOM
Telecom-, Signal and RF Relays
108-98000 Rev. C
HF3 Relay
Terminal assignment
Relay top view
Non-latching type,
not energized condition
Latching type, 1 coil
rest condition
Latching type, 2 coils
reset condition
Coil Operating Range
140 mW
70 mW
3.5
70 mW
3
Umax. at 0 A
Unom. nominal coil voltage
Uop. min.
Coil Voltage [U/Unom]
Coil Voltage [U/Unom]
140 mW
Umax. at 0 A
2.5
2
1.5
1
Unom. nominal coil voltage
0.5
Uop. min.
Urel. min.
0
-55 -45 -35 -25 -15
Ambient Temperature [°C]
Unom =
Umax. =
-5
5
15 25 35
45 55 65 75 85 95 105 115 125 135
Ambient Temperature [°C]
Nominal coil voltage
Upper limit of the operative range of
the coil voltage (limiting voltage)
Uop. min. = Lower limit of the operative range of
the coil voltage (reliable operate voltage)
For latching relays Uset min. resp. Ureset min.
Urel. min. = Lower limit of the operative range of
the coil voltage (reliable release voltage)
All specifications subject to change. Consult Tyco Electronics for latest specifications.
of 12
AXICOM
Telecom-, Signal and RF Relays
108-98000 Rev. C
HF3 Relay
Coil Data (values at 23 °C)
Nominal
voltage
Unom
Vdc
Operate/set voltage range
Ordering Information
Release/
reset voltage
Minimum
Coil
power
Coil
Resistance
Ω / ± 10 %
Relay
code
Tyco part
number
Minimum
voltage Umin
Maximum
voltage Umax
Vdc
Vdc
Vdc
mW
6.50
9.80
10.90
13.00
19.60
26.10
52.30
0.30
0.45
0.50
0.60
0.90
1.20
2.40
140
140
140
140
140
140
140
64
145
178
257
574
1028
4114
HF3 51
HF3 52
HF3 53
HF3 54
HF3 55
HF3 56
HF3 57
1462051-1
1-1462051-6
1462051-2
1-1462051-7
1462051-3
1462051-4
1462051-5
9.20
13.85
15.30
18.50
27.70
37.00
74.00
2.25
3.38
3.75
4.50
6.75
9.00
18.00
70
70
70
70
70
70
70
128
289
357
514
1157
2057
8228
HF3 71
HF3 72
HF3 73
HF3 74
HF3 75
HF3 76
HF3 77
1462051-6
1-1462051-8
1462051-7
1-1462051-9
1462051-8
1462051-9
1-1462051-0
6.50
9.80
10.90
13.00
19.60
26.10
52.30
2.25
3.38
3.75
4.50
6.75
9.00
18.00
140
140
140
140
140
140
140
64
145
178
257
574
1028
4114
HF3 91
HF3 92
HF3 93
HF3 94
HF3 95
HF3 96
HF3 97
1-1462051-1
2-1462051-0
1-1462051-2
2-1462051-1
1-1462051-3
1-1462051-4
1-1462051-5
6.50
9.80
10.90
13.00
19.60
26.10
52.30
0.30
0.45
0.50
0.60
0.90
1.20
2.40
140
140
140
140
140
140
140
64
145
178
257
574
1028
4114
HF3 01
HF3 02
HF3 03
HF3 04
HF3 05
HF3 06
HF3 07
1462050-1
1-1462050-6
1462050-2
1-1462050-7
1462050-3
1462050-4
1462050-5
9.20
13.85
15.30
18.50
27.70
37.00
74.00
2.25
3.38
3.75
4.50
6.75
9.00
18.00
70
70
70
70
70
70
70
128
289
357
514
1157
2057
8228
HF3 21
HF3 22
HF3 23
HF3 24
HF3 25
HF3 26
HF3 27
1462050-6
1-1462050-8
1462050-7
1-1462050-9
1462050-8
1462050-9
1-1462050-0
Non-Latching, 1 coil, 50 Ω version
3
4.5
5
6
9
12
24
2.25
3.38
3.75
4.50
6.75
9.00
18.00
Latching, 1 coil, 50 Ω version
3
4.5
5
6
9
12
24
2.25
3.38
3.75
4.50
6.75
9.00
18.00
Latching, 2 coils, 50 Ω version
3
4.5
5
6
9
12
24
2.25
3.38
3.75
4.50
6.75
9.00
18.00
Non-Latching, 1 coil, 75 Ω version
3
4.5
5
6
9
12
24
2.25
3.38
3.75
4.50
6.75
9.00
18.00
Latching, 1 coil, 75 Ω version
3
4.5
5
6
9
12
24
2.25
3.38
3.75
4.50
6.75
9.00
18.00
Latching, 2 coils, 75 Ω version
3
2.25
6.50
2.25
140
64
HF3 41
1-1462050-1
4.5
3.38
9.80
3.38
140
145
HF3 42
2-1462050-0
5
3.75
10.90
3.75
140
178
HF3 43
1-1462050-2
6
4.50
13.00
4.50
140
257
HF3 44
2-1462050-1
9
6.75
19.60
6.75
140
574
HF3 45
1-1462050-3
12
9.00
26.10
9.00
140
1028
HF3 46
1-1462050-4
24
18.00
52.30
18.00
140
4114
HF3 47
1-1462050-5
Values given are valid for the coil at ambient temperature of 23 °C after preenergizing with nominal voltage without contact current.
All specifications subject to change. Consult Tyco Electronics for latest specifications.
of 12
AXICOM
Telecom-, Signal and RF Relays
108-98000 Rev. C
HF3 Relay
Contact Data
Number of contacts and type
1 changeover (SPDT)
Contact material
Silver, gold-covered
Limiting continuous current at max. ambient temperature
2A
Maximum switching current
2A
Maximum swichting voltage
220 Vdc / 250 Vac
Maximum switching capacity
60 W / 62.5 VA / 50 W (2.5 GHz)
Initial contact resistance at10 mA / 20 mV
< 100 mΩ
Mechanical endurance
107 operations
Insulation
Insulation resistance at 500 VDC
> 100 MΩ
Dielectric test voltage (1 min)
between coil and contacts
between open contacts
1000 Vrms
600 Vrms
Surge voltage resistance according to FCC 68 (10 / 160 μs)
and (2 / 10 μs)
between coil and contacts
between open contacts
1500 V
1000 V
General Data
Operate time at Unom typ./max.
3 ms / 5 ms
Reset time (latching) at Unom typ. / max.
3 ms / 5 ms
Release time without diode in parallel (non-latching) typ./max.
2 ms / 4 ms
Release time with diode in parallel (non-latching) typ./max.
4 ms / 6 ms
Bounce time at closing contact typ. / max.
1 ms / 3 ms
Maximum switching rate without load
50 operations/s
Ambient temperature
-55 °C ... +85 °C
Thermal resistance
> 165 K/W
Maximum permissable coil temperature
125 °C
Vibration resistance (function)
35 G
10 to 1000 Hz
Shock resistance, half sinus, 11 ms
50 G (function)
150 G (damage)
Degree of protection / Environmental protection
immersion cleanable, IP 67 / RT III
Needle flame test
application time 20 s, burning time < 15 s
Mounting position
any
Processing information
Ultrasonic cleaning is not recommended
Weight (mass)
max. 2,5 g
Terminal surface
SnCu 0.7
Moisture sensitive level (JEDEC J-STD-020B)
MSL 3
Resistance to soldering heat
265 °C/10 s
All specifications subject to change. Consult Tyco Electronics for latest specifications.
of 12
AXICOM
Telecom-, Signal and RF Relays
108-98000 Rev. C
HF3 Relay
High Frequency Data
RF characteristics
Isolation at 100 MHz / 900 MHz / 3 GHz
Insertion loss at 100 MHz / 900 MHz / 3 GHz
V.S.W.R. at 100 MHz / 900 MHz / 3 GHz
1
50 Ω
-80dB / -72dB / -45dB
-0.03dB / -0.12dB / -0.35dB
1.05 / 1.15 / 1.20
75 Ω
-80dB / -72dB / -40dB1
-0.03dB / -0.12dB / -0.4dB1
1.05 / 1.20 / 1.401
Values given at frequency of 2.5 GHz
75 Ohm Version
0
0
-20
-20
Isolation [dB]
Isolation [dB]
50 Ohm Version
-40
NO
-60
NC
-80
-40
NO
-60
-80
NC
-100
-100
-120
-120
0
500
1000
1500
2000
2500
0
3000
500
1000
1500
2000
2500
2000
2500
2000
2500
Frequency [Mhz]
Frequency [Mhz]
0.1
Insertion-loss [dB]
Insertion-loss [dB]
0.1
0.0
NC
-0.1
-0.2
NO
-0.3
0.0
NO
-0.1
NC
-0.2
-0.3
-0.4
0
-0.4
0
500
1000
1500
2000
2500
500
3000
1.25
1.25
1.20
1.20
1.15
1.15
VSWR
VSWR
1500
Frequency [Mhz]
Frequency [Mhz]
1.10
1000
NC
1.10
NO
NC
1.05
1.05
NO
1.00
0
500
1000
1500
2000
2500
3000
Frequency[Mhz]
All specifications subject to change. Consult Tyco Electronics for latest specifications.
1.00
0
500
1000
1500
Frequency[Mhz]
of 12
AXICOM
Telecom-, Signal and RF Relays
108-98000 Rev. C
HF3 Relay
Recommended Soldering Conditions
Soldering conditions according IEC 60058-2-58 and IPC/JEDEC J-STD-020B
20 - 40 sec
Temperature °C
240 °C
Full line:
typical
Dotted line: process limits
180 °C
forced
cooling
130 °C
external preheating
100 °C
Time (s)
Vapor Phase Soldering: Temperature/Time Profile
(Lead and Housing Peak Temperature)
Temperature °C
Recommended reflow soldering profile
Time (s)
Infrared Soldering: Temperature/Time Profile
(Lead and Housing Peak Temperature)
Temperature
Temperature
°C °C
Resistance to soldering heat - Reflow profile
Time (s)
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Infrared Soldering: Temperature/Time Profile
(Lead and Housing Peak Temperature)
of 12
AXICOM
Telecom-, Signal and RF Relays
108-98000 Rev. C
HF3 Relay
Packing
Dimensions in mm
Tape and reel for SMT version
400 relays / reel
400 or 2’000 relays / box
Reel dimension
All specifications subject to change. Consult Tyco Electronics for latest specifications.
10 of 12
AXICOM
Telecom-, Signal and RF Relays
108-98000 Rev. C
HF3 Relay
IM Relays
D2n Relays
4th generation slim line – low profile polarized 2 c/o telecom relay with
bifurcated contacts, available as non latching or latching relay with 1
coil. Nominal voltage range from 1.5 ... 24 V, coil power consumption of
50 ... 200 mW, latching relays with 1 coil 100 mW. The IM relay is available as through hole and surface mount type (J-Legs and Gull Wings)
and capable to switch loads up to 60 W/62,5 VA. It is currently the only
2 A rated 4G relay on the market. Dielectric strength fulfills the Telcordia
requirements according GR 1089 (2,5 kV – 2 / 10 µs) and FCC part 68
(1,5 kV – 10 / 160 µs). The IM relay is tested according CECC/IECQ and
certified in accordance with IEC/EN 60950 and UL 60950. Dimensions
approx. 10 x 6 mm board space and 5.65 mm height.
2nd generation non polarized 2 c/o relay for telecom and various
other applications. Nominal voltage range from 3 ... 48 V, coil power consumption from 150 .... 500 mW. The D2n relay is capable to
switch currents up to 3 A. Dielectric strength fulfills the requirements
according FCC part 68 (1,5 kV – 10 / 160 µs). Dimensions approx. 20
x10 mm board space and 11 mm height.
P2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,
available as non latching or latching relay with 1 or 2 coils. Nominal
voltage range from 3 ... 24 V, coil power consumption 140 mW, latching relays with 1 coil 70 mW. The P2 Relay is available as through
hole or surface mount type and capable to switch currents up to 5 A.
Dielectric strength fulfills the Telcordia requirements according GR
1089 (2,5 kV – 2 / 10 µs) and FCC part 68 (1,5 kV – 10 / 160 µs). The P2
relay is tested according CECC/IECQ and certified in accordance with
IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board
space and 10 mm height.
P1 Relays
Extremely sensitive, polarized 1 c/o relay with bifurcated contacts for a
wide range of applications, available as non latching or latching relay
with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power
consumption 65 mW, latching relays with 1 coil 30 mW. The P1 relay
is available as through hole or surface mount type and capable to
switch currents up to 1 A. Dielectric strength fulfills the requirements
according FCC part 68 (1,5 kV – 10 / 160 µs). Dimensions approx. 13
x 7,6 mm board space and 7 mm height for THT or 8 mm height for
SMT version.
W11 Relays
Low cost, non polarized 1 c/o relay for various applications. Nominal
voltage range from 3 ... 24 V, coil power consumption 450 mW, sensitive versions 200 mW. The W11 relay is capable to switch currents
up to 3 A. Dielectric strength 1000 Vrms. Dimensions approx. 15,6 x
10,6 mm board space and 11,5 mm height.
FX2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,
available as non latching or latching relay with 1 coil. Nominal voltage
range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for
the high sensitive version, 140... 300 mW for the standard version,
latching relays with 1 coil 100 mW. The FX2 relay is available as
through hole type and capable to switch loads up to 60 W/62,5 VA.
Dielectric strength fulfills the Telcordia requirements according GR
1089 (2,5 kV – 2 / 10 µs) and FCC part 68 (1,5 kV – 10 / 160 µs). The
FX2 relay is tested according CECC/IECQ and certified in accordance
with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm
board space and 10,7 mm height.
FT2 / FU2 Relays
3rd generation non polarized, non latching 2 c/o telecom relay with
bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power
consumption 200 ... 300 mW. Most sensitive 48 V relay. Available as
through hole and surface mount type. Dielectric strength fulfills the
Telcordia requirements according GR 1089 (2,5 kV – 2 / 10 µs) and FCC
part 68 (1,5 kV – 10 / 160 µs). The FT2/FU2 relay is tested according
CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950.
Dimensions approx. 15 x 7,5 mm board space and 10 mm height.
Reed Relays
High sensitive, non polarized relay for telecom and various other
applications, available with 1 n/o, 2 n/o or 1c/o contacts. Nominal
voltage range from 5 ... 24 V, coil power consumption 50...280 mW
for 1 n/o and 125 ... 280 mW for 2 n/o or 1 c/o versions. Reedrelays are
available in DIP or SIL housing and capable to switch currents up to
0,5 A. Integrated diode and/or electrostatic shield optional. Dielectric
strength 1500 Vdc. Dimensions approx. 19,3 x 7 mm board space and
5 ... 7,5 mm height for DIP or 19,8 x 5 mm board space and 7,8 mm
height for SIL version.
Cradle Relays
Extremely reliable and mature relay family of 1st generation for
various signal switching applications. Available as non polarized,
polarized / latching and relay with AC coil. The benefit is the possibility
of combining various contact sets from 1 up to 6 poles, single and bifurcated contacts, different contact materials with a coil voltage range
from 1,5 Vdc to 220 Vac. Cradle relays are available as dust protected
and hermetically sealed versions, with plug in or solder terminals
and are capable to switch currents up to 5 A. Forcibly guided (linked)
contact sets optional. Dielectric strength 500 Vrms. Dimensions from
approx. 19 x 24 to 19x35 mm board space and 30 mm height.
FP2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,
available as non latching or latching relay with 1 or 2 coils. Nominal
voltage range from 3 ... 48 V, coil power consumption of 80 ... 260
mW for the high sensitive version, 140... 300 mW for the standard
version, latching relays with 1 coil 100 mW.. The FP2 Relay is available
as through hole type and capable to switch loads up to 60 W/62,5 VA.
Dielectric strength fulfills FCC part 68 (1,5 kV – 10 / 160 µs). The FP2
is tested according CECC/IECQ approved. Dimensions approx. 14 x
9 mm board space and 5 mm height.
Other Relays
MT2
High performance low cost RF relay with excellent RF characteristics.
Available with an impedance of 50 and 75 Ohm. Suitable for frequencies up to 3 GHz. Actually smallest RF relay available combining small
size, excellent RF performance and SMD solderability. Available as non
latching or latching relay with 1 or 2 coils and a nominal coil voltage
range from 3 ... 24 V, coil power consumption 140 mW, latching relays
with 1 coil 70 mW. Dimensions 14.6 x 7.3 x 10 mm.
2nd generation non polarized, non latching 2 c/o telecom and signal relay with bifurcated contacts. Nominal voltage range from
3 ... 48 V, coil power consumption 150/200/300/400 and 550 mW.
Dielectric strength fulfills the requirements according FCC part 68
(1,5 kV – 10 / 160 µs).
Dimensions approx. 20 x 10 mm board space and 11 mm height.
All specifications subject to change. Consult Tyco Electronics for latest specifications.
We offer a variety of different relay families for maintenance and
replacement purposes. These relays are up to 60 years old now, such
as Card Relay SN (V23030 / V23031 series), Small General Purpose
Relay (V23006 series), Small Polarized Relay (V23063 ... V23067 and
V23163 ... V23167 series). Accessories like sockets, hold down springs,
etc. optional.
HF3 Relay
11 of 12
Tyco Electronics Logistics AG
Werk Axicom Au
Seestrasse 295
CH-8804 Au-Wädenswil / Switzerland
Phone +41 44 782 91 11
Fax
+41 44 782 90 00
E-mail: [email protected]
Tyco Electronics
Paulsternstrasse 26
D-13629 Berlin / Germany
Phone +49 30 386 38573
Fax
+49 30 386 38575
E-mail: [email protected]
Tyco Electronics EC Trutnov s.r.o.
Komenského 821
CZ-541 01 Trutnov / Czech Republic
E-mail: [email protected]
Tyco Electronics Corporation
POB 3608,
Harrisburg, PA 17105, USA
Phone +1 800-522-6752
Similar pages