XP Power ECE80US15 Ac-dc power supply Datasheet

ECE80 Series
AC-DC Power Supplies
80 Watts
• Ultra Compact Size
• Single Outputs from 12 to 48 V
• Encapsulated
• PCB, Chassis Mount and DIN Rail Versions
• <0.3 W No Load Input Power
• -40 to +70 °C Operation
• Peak Load Capability
• 3 Year Warranty
Dimensions:
The ECE80 series of compact encapsulated AC-DC power modules are available in both PCB &
chassis mount versions offering exceptional power density of >11W/in3. Output voltages are
available from 12 – 48 VDC and these “green power” modules offer high active mode efficiency and
low no load power consumption. They also provide a peak load capability up to 130% of nominal
power for up to 30s and a wide operating temperature range from -40 to +70°C.
ECE80:
3.60 x 1.80 x 1.10” (91.4 x 45.72 x 28.0 mm)
ECE80-S:
4.45 x 1.87 x 1.12” (113.0 x 47.5 x 28.5 mm)
Models & Ratings
Output Power
Output Current
Output Voltage
Nominal
Peak
(1)
Efficiency
(4)
Model Number
80 W
12.0 V
6.67 A
8.67 A
88%
ECE80US12
80 W
15.0 V
5.33 A
6.93 A
88%
ECE80US15
80 W
24.0 V
3.33 A
4.33 A
87%
ECE80US24
80 W
36.0 V
2.22 A
2.89 A
87%
ECE80US36
80 W
48.0 V
1.67 A
2.17 A
87%
ECE80US48
(2,3)
Notes
1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal power.
2. Add suffix -S to model number to denote chassis mount with screw terminal type, e.g. ECE80US12-S.
3. A screw terminal version (-S) is available with DIN Clip attached. Add suffix ‘D’, e.g. ECE80US24-SD. DIN Rail mounting clip is available as a separate item, order
code ECE80 DIN CLIP.
4. Average of efficiencies measured at 25%, 50%, 75% & 100% load with 230 VAC input.
Summary
Characteristic
Input Range
Minimum
Typical
85
No Load Input Power
1
Efficiency
86
Operating Temperature
-40
87
Maximum
Units
Notes & Conditions
264
VAC
Derate load from 100% at 90 VAC to 90% at 85 VAC
<0.3
W
<0.5
W
48 V version
88
%
See note 4 above
+70
°C
Some specification parameters may not met below -25 °C.
Derate linearly from 100% load at +50 °C to 50% load at
70 °C.
EMC
EN55022 & 32 Level B Conducted & Radiated, EN61000-4, EN61000-3
Safety Approvals
EN60950-1, UL60950-1, CSA22.2 No. 234 per cUL
www.xppower.com
12-36 V versions
ECE80 Series
AC-DC Power Supplies
Input
Maximum
Units
Notes & Conditions
Input Voltage - Operating
85
264
VAC
Derate load from 100% at 90 VAC to 90% at 85 VAC
Input Frequency
47
63
Hz
Characteristic
Minimum
Typical
Power Factor
EN61000-3-2 class A compliant
Input Current
1.4/0.87
No Load Input Power
Inrush Current
A rms
At 115/230 VAC
0.3
W
12-36 V versions
0.5
W
48 V version
A
115/230 VAC cold start at 25 °C
60/120
Earth Leakage Current
Input Protection
Class II construction no earth
Internal T3.15 A/250 VAC fuse
Output
Characteristic
Minimum
Output Voltage
12
Typical
Initial Set Accuracy
Minimum Load
Maximum
Units
Notes & Conditions
48
VDC
See Models and Ratings table
1
%
At 100% load
A
No minimum load required
0
Start Up Delay
0.5
s
Start Up Rise Time
30
ms
Hold Up Time
8.4
15
ms
At full load and 115 VAC
Line Regulation
±0.5
%
Load Regulation
±1
%
Transient Response
4
%
Recovery within 1% in less than 500 µs
for a 25% load change
For ECE80/ECE80-S, 20 MHz bandwidth
1/2
% pk-pk
Overvoltage Protection
Ripple & Noise
115
140
% Vnom
Overload Protection
110
185
%
0.02
%/˚C
Short Circuit Protection
Trip & restart (hiccup mode)
Temperature Coefficient
General
Characteristic
Minimum
Typical
Maximum
Units
Efficiency
86
87
88
%
Isolation
3000
Switching Frequency
VAC
65
Power Density
Weight
See Models & Ratings table
Input to Output
kHz
11.2
Mean Time Between Failure
Notes & Conditions
W/in3
>300
kHrs
MIL-HDBK-217F, +25 °C GB
0.66 (260)
lb (g)
ECE80
0.71 (280)
lb (g)
ECE80-S
Maximum
Units
Notes & Conditions
Environmental
Characteristic
Minimum
Typical
Operating Temperature
-40
+70
°C
Storage Temperature
-40
+85
°C
95
%RH
3048
m
Cooling
Humidity
Operating Altitude
Vibration
Some specification parameters may not met below -25 °C.
Derate linearly from 100% load at +50 °C to 50% load at 70 °C.
Convection-cooled
Non-condensing
2 g, 10 Hz to 500 Hz, 10 mins/cycle, 60 mins each cycle
www.xppower.com
2
ECE80 Series
AC-DC Power Supplies
EMC: Emissions
Phenomenon
Test Level
Standard
Conducted
EN55022/55032
Class B
Radiated
EN55022/55032
Class B
Harmonic Current
EN61000-3-2
Voltage Flicker
EN61000-3-3
Criteria
Notes & Conditions
Class A
EMC: Immunity
Test Level
Criteria
EN61000-4-2
±6 kV/±8 kV
A
Radiated
EN61000-4-3
10 V/m 80% mod
A
EFT
EN61000-4-4
3
A
Phenomenon
Standard
ESD
Surges
EN61000-4-5
2
A
Conducted
EN61000-4-6
3
A
Magnetic Fields
EN61000-4-8
3
A
EN61000-4-11
DIP: >95% 10 ms
DIP: 30% 500 ms
INT: >95% 5000 ms
A
A
B
Dips and Interruptions
Notes & Conditions
Contact/Air Discharge
At 100 VAC and 230 VAC
Safety Approvals
Safety Agency
Safety Standard
UL
UL60950-1, CSA 22.2 No.234 per cUL
Notes & Conditions
TUV
EN60950-1
CB
IEC60950-1
Mechanical Details
ECE80
ECE80 Screw Terminal (-S)
0.139 (3.54)
3.60 (91.4)
ACL
1.80
(45.7)
1.18
(30.0)
0.50
(12.7)
0.18 (4.5)
4x ø0.14
(4x ø3.5)
0.44
(11.2)
+Vo
TOP VIEW
4.09 (104.0)
ACN
-Vo
1.87
(47.5)
0.159
(4.05)
+Vo
TOP VIEW
ACL
-Vo
0.84
(21.3)
1.50
(38.1)
ACN
0.14
(3.55)
3.32 (84.3)
3.50 (89.7)
0.54 (13.8)
1.10
(28.0)
0.20
(4.7)
1º
1.12
(28.5)
4x ø 0.06 (ø1.5)
0.24
(6.2)
0.4 (10.2)
0.10
(2.5)
4.45 (113.0)
Optional
DIN clip
0.58
(14.73)
1.38 (35.0)
Notes
1. All dimensions in inches (mm).
2. Weight: ECE80: 0.66 lbs (260 g)
ECE80-S: 0.71 lbs (270 g)
3. Tolerances: x.xx = ± 0.02 (x.x = ± 0.5), x.xxx = ± 0.01 (x.xx = ± 0.25)
3
www.xppower.com
20 Dec 16