STMicroelectronics M41T83SM6E Serial i2c bus rtc with battery switchover Datasheet

M41T82
M41T83
Serial I2C bus RTC with battery switchover
Features
■
Ultra-low battery supply current of 365 nA
■
Factory calibrated accuracy ±5 ppm
guaranteed after 2 reflows (SOX18)
– Much better accuracies achievable using
built-in programmable analog and digital
calibration circuits
■
2.0 V to 5.5 V clock operating voltage
■
Counters for tenths/hundredths of seconds,
seconds, minutes, hours, day, date, month,
year, and century
■
Automatic switchover and reset output circuitry
(fixed reference)
– M41T83S
VCC = 3.00 V to 5.50 V
(2.85 V ≤ VRST ≤ 3.00 V)
– M41T83R
VCC = 2.70 V to 5.50 V
(2.55 V ≤ VRST ≤ 2.70 V)
– M41T83Z
VCC = 2.38 V to 5.50 V
(2.25 V ≤ VRST ≤ 2.38 V)
2
■
Serial interface supports I C bus (400 kHz
protocol)
■
Programmable alarm with interrupt function
(valid even during battery backup mode)
■
Optional 2nd programmable alarm available
■
Square wave output defaults to 32 KHz on
power-up (M41T83 only)
■
RESET (RST) output
■
Watchdog timer
■
Programmable 8-bit counter/timer
■
7 bytes of battery-backed user SRAM
■
Battery low flag
■
Power-down time stamp (HT bit)
■
Low operating current of 80 µA
October 2010
QFN16, 4 mm x 4 mm (QA)
(VFQFPN16)
18
1
SOX18 (18-pin, 300 mil SOIC
with embedded crystal) (MY)
SO8 (M)
■
Oscillator stop detection
■
Battery or SuperCap™ backup
■
Operating temperature of –40 °C to 85 °C
■
Package options include:
– a 16-lead QFN (M41T83),
– an 18-lead embedded crystal SOIC
(M41T83), or
– an 8-lead SOIC (M41T82)
■
RoHS compliance: lead-free components are
compliant with the RoHS directive
Doc ID 12578 Rev 12
1/61
www.st.com
1
Contents
M41T82-M41T83
Contents
1
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.1
3
2/61
2-wire bus characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.1.1
Bus not busy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.1.2
Start data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.1.3
Stop data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.1.4
Data valid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.1.5
Acknowledge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.2
Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.3
Write mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.4
Data retention and battery switchover (VSO = VRST) . . . . . . . . . . . . . . . . 18
2.5
Power-on reset (trec) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Clock operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.1
Power-down time-stamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.2
Clock/control register map and divider chain . . . . . . . . . . . . . . . . . . . . . . 20
3.3
Real-time clock accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.4
Clock calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
3.4.1
Digital calibration (periodic counter correction) . . . . . . . . . . . . . . . . . . . 26
3.4.2
Analog calibration (programmable load capacitance) . . . . . . . . . . . . . . 29
3.5
Setting the alarm clock registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.6
Optional second programmable alarm and user SRAM . . . . . . . . . . . . . . 34
3.7
Watchdog timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
3.8
8-bit (countdown) timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
3.8.1
M41T83 timer interrupt/output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
3.8.2
Timer flag (TF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3.8.3
Timer interrupt enable (TIE, M41T83 only) . . . . . . . . . . . . . . . . . . . . . . 37
3.8.4
Timer enable (TE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3.8.5
TD1/0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3.9
Square wave output (M41T83 only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3.10
Battery low warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
3.11
Century bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Doc ID 12578 Rev 12
M41T82-M41T83
Contents
3.12
Oscillator fail detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
3.13
Oscillator fail interrupt enable (M41T83 only) . . . . . . . . . . . . . . . . . . . . . . 41
3.14
IRQ1/FT/OUT pin, frequency test, interrupts and the OUT bit
(M41T83 only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
3.14.1
Active mode operation on VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
3.14.2
Backup mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
3.15
FT/RST pin, frequency test and reset output pin (M41T82 only) . . . . . . . 44
3.16
Initial power-on defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
3.17
OTP bit operation (M41T83 in SOX18 package only) . . . . . . . . . . . . . . . 45
4
Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
5
DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
6
Package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
7
Part numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
8
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
9
Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Doc ID 12578 Rev 12
3/61
List of tables
M41T82-M41T83
List of tables
Table 1.
Table 2.
Table 3.
Table 4.
Table 5.
Table 6.
Table 7.
Table 8.
Table 9.
Table 10.
Table 11.
Table 12.
Table 13.
Table 14.
Table 15.
Table 16.
Table 17.
Table 18.
Table 19.
Table 20.
Table 21.
Table 22.
Table 23.
Table 24.
Table 25.
Table 26.
Table 27.
Table 28.
Table 29.
Table 30.
Table 31.
Table 32.
4/61
Signal names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
M41T82 clock/control register map (32 bytes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Key to Table 2: M41T82 clock/control register map (32 bytes). . . . . . . . . . . . . . . . . . . . . . 22
M41T83 clock/control register map (32 bytes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Key to Table 4: M41T83 clock/control register map (32 bytes). . . . . . . . . . . . . . . . . . . . . . 24
Digital calibration values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Analog calibration values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Alarm repeat modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Watchdog register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Timer control register map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Timer interrupt operation in free-running mode (with TI/TP = 1). . . . . . . . . . . . . . . . . . . . . 36
Timer source clock frequency selection (244.1 µs to 4.25 hrs). . . . . . . . . . . . . . . . . . . . . . 37
Square wave output frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Century bits examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Priority for IRQ1/FT/OUT pin when operating on VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Priority for IRQ1/FT/OUT pin when operating in backup mode . . . . . . . . . . . . . . . . . . . . . 43
Initial power-on default values (part 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Initial power-up default values (part 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Operating and AC measurement conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
DC characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Crystal electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Oscillator characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Power down/up trip points DC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
QFN16 – 16-lead, quad, flat package, no lead, 4 x 4 mm pack. mech. data . . . . . . . . . . . 53
SOX18 – 18-lead plastic small outline, 300 mils, embedded crystal, package mech. data 55
SO8 – 8-lead plastic small outline (150 mils body width), package mech. data . . . . . . . . . 56
Carrier tape dimensions for QFN16, SOX18, and SO8 packages . . . . . . . . . . . . . . . . . . . 57
Ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Doc ID 12578 Rev 12
M41T82-M41T83
List of figures
List of figures
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
Figure 6.
Figure 7.
Figure 8.
Figure 9.
Figure 10.
Figure 11.
Figure 12.
Figure 13.
Figure 14.
Figure 15.
Figure 16.
Figure 17.
Figure 18.
Figure 19.
Figure 20.
Figure 21.
Figure 22.
Figure 23.
Figure 24.
Figure 25.
Figure 26.
Figure 27.
Figure 28.
Figure 29.
Figure 30.
Figure 31.
Figure 32.
Figure 33.
M41T82 logic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
M41T83 logic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SO8 (M) connections (M41T82) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
QFN16 (QA) connections (M41T83) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SOX18 (MY) connections (M41T83). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
M41T82 block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
M41T82 hardware hookup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
M41T83 block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
M41T83 hardware hookup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Serial bus data transfer sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Acknowledgement sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Slave address location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Read mode sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Alternative read mode sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Write mode sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Internal load capacitance adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Crystal accuracy across temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Clock accuracy vs. on-chip load capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Clock divider chain and calibration circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Crystal isolation example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Timer output waveform in free-running mode (with TI/TP = 1) . . . . . . . . . . . . . . . . . . . . . . 36
Battery check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
IRQ1/FT/OUT output pin circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Measurement AC I/O waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
ICC2 vs. temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Power down/up mode AC waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Bus timing requirement sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
QFN16 – 16-lead, quad, flat package, no lead, 4 x 4 mm body size outline . . . . . . . . . . . 53
QFN16 – 16-lead, quad, flat package, no lead, 4 x 4 mm, recommended footprint . . . . . . 54
32 KHz crystal + QFN16 vs. VSOJ20 mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
SOX18 – 18-lead plastic small outline, 300 mils, embedded crystal, outline . . . . . . . . . . . 55
SO8 – 8-lead plastic small package outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Carrier tape for QFN16, SOX18, and SO8 packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Doc ID 12578 Rev 12
5/61
Description
1
M41T82-M41T83
Description
The M41T8x are low power serial I2C real-time clocks with a built-in 32.768 kHz oscillator
(external crystal-controlled for the QFN16 and SO8 packages, embedded crystal for the
SOX18 package). Eight bytes of the register map (see Table 2 on page 21) are used for the
clock/calendar function and are configured in binary coded decimal (BCD) format. An
additional 17 bytes of the register map provide status/control of the two alarms, watchdog,
8-bit counter, and square wave functions. An additional seven bytes are made available as
user SRAM.
Addresses and data are transferred serially via a two-line, bidirectional I2C interface. The
built-in address register is incremented automatically after each WRITE or READ data byte.
The M41T8x has a built-in power sense circuit which detects power failures and
automatically switches to the battery supply when a power failure occurs. The energy
needed to sustain the clock operations can be supplied by a small lithium button battery
when a power failure occurs.
Functions available to the user include a non-volatile, time-of-day clock/calendar, two alarm
interrupts, watchdog timer, programmable 8-bit counter, and square wave outputs. The eight
clock address locations contain the century, year, month, date, day, hour, minute, second,
and tenths/hundredths of a second in 24-hour BCD format. Corrections for 28, 29 (leap
year), 30, and 31 day months are made automatically. The M41T83 is supplied in either a
QFN16 (QA) or an SOX18 (MY), 300 mil SOIC which includes an embedded 32 KHz crystal.
The SOX18 package requires only a user-supplied battery to provide non-volatile operation.
The M41T82 is available only in an SO8 (M) package.
6/61
Doc ID 12578 Rev 12
M41T82-M41T83
Figure 1.
Description
M41T82 logic diagram
VBAT
VCC
XI
XO
(1)
FT/RST
SDA
SCL
VSS
AI11196
1. Open drain
Figure 2.
M41T83 logic diagram
VBAT VCC
SQW(2)
XI(1)
IRQ1/OUT/FT(3)
XO(1)
SDA
RST(3)
SCL
IRQ2(3)
VSS
AI11195
1. For QFN16 package only
2. Defaults to 32 KHz on power-up
3. Open drain
Doc ID 12578 Rev 12
7/61
Description
M41T82-M41T83
Table 1.
Signal names
Symbol
Description
XI(1)
XO
32 KHz oscillator input
(1)
IRQ1/OUT/FT
SQW(3)
RST
32 KHz oscillator output
(2)
Interrupt 1/output driver/frequency test output (open drain)
32 KHz programmable square wave output
Power-on reset output (open drain)
FT/RST
Frequency test output/power-on reset (open drain - M41T82 only)
IRQ2(2)
Interrupt for alarm 2 (open drain)
SDA
Serial data address input/output
SCL
Serial clock input
VBAT
Battery supply voltage (tie VBAT to VSS if no battery is connected.)
DU
(4)
Do not use
VCC
Supply voltage
VSS
Ground
1. For SO8 and QFN16 packages only.
2. For SOX18 and QFN16 packages only.
3. Defaults to 32 KHz on power-up.
4. DU pin must be tied to VCC.
8/61
Doc ID 12578 Rev 12
M41T82-M41T83
Figure 3.
Description
SO8 (M) connections (M41T82)
XI
XO
VBAT
VSS
1
2
3
4
M41T82
8
7
6
5
VCC
(1)
FT/RST
SCL
SDA
AI11199
1. Open drain output
RST(1)
1
NC
2
XI
VCC
NC
QFN16 (QA) connections (M41T83)
XO
Figure 4.
16
15
14
13
12
IRQ2(1)
11
(1)
IRQ1/FT/OUT
M41T83
(2)
4
9
SDA
SQW
5
6
7
8
NC
SCL
NC
10
VSS
3
VBAT
NC
AI11197
1. Open drain output.
2. Defaults to 32 KHz on power-up.
Figure 5.
SOX18 (MY) connections (M41T83)
NC
(1)
NF
(1)
NF
NC
(2)
RST
DU(3)
(4)
SQW
VBAT
VSS
1
2
3
4
5
6
7
8
9
18
17
16
15
M41T83 14
13
12
11
10
NC
(1)
NF
NF(1)
VCC
IRQ2(2)
NC
(2)
IRQ1/FT/OUT
SCL
SDA
AI11198
1. NF pins must be tied to VSS. Pins 2 and 3, and 16 and 17 are internally shorted together.
2. Open drain output.
3. Do not use (must be tied to VCC).
4. Defaults to 32 KHz on power-up.
Doc ID 12578 Rev 12
9/61
Description
M41T82-M41T83
Figure 6.
M41T82 block diagram
REAL TIME CLOCK
CALENDAR
OSCILLATOR FAIL
CIRCUIT
XI
32KHz
OSCILLATOR
XO
CRYSTAL
ALARM1
ALARM2
WATCHDOG
SDA
I2C
INTERFACE
FT
FREQUENCY TEST
SCL
OUTPUT DRIVER
WRITE
PROTECT
VCC < VRST
8-BIT COUNTER
USER SRAM (7 Bytes)
INTERNAL
POWER
VCC
VBAT
VRST/VSO(1)
COMPARE
trec
TIMER
RST (2)
AI11812
1. VRST = VSO = 2.93 V (S), 2.63 V (R), and 2.32 V (Z).
2. Open drain output.
Figure 7.
M41T82 hardware hookup
VCC
MCU
M41T82
VCC
XI
VCC
(1)
FT/RST
Reset Input
XO
VBAT
VSS
SCL
Serial Clock Line
SDA
Serial Data Line
AI11813
1. Open drain output.
10/61
Doc ID 12578 Rev 12
M41T82-M41T83
Description
Figure 8.
M41T83 block diagram
REAL TIME CLOCK
CALENDAR
OSCILLATOR FAIL
CIRCUIT
XI
32KHz
OSCILLATOR
XO
CRYSTAL
OFIE
A1IE
ALARM1
A2IE
ALARM2
IRQ2(1)
IRQ1/FT/OUT(1)
WATCHDOG
SDA
2
I C
INTERFACE
FT
FREQUENCY TEST
SCL
WRITE
PROTECT
VCC < VRST
OUT
OUTPUT DRIVER
TIE
8-BIT COUNTER
SQWE
SQUARE WAVE
SQW
8 BITS OF OTP
USER SRAM (7 Bytes)
INTERNAL
POWER
VCC
VBAT
VRST/VSO(2)
COMPARE
trec
TIMER
RST(1)
AI11800
1. Open drain output.
2. VRST = VSO = 2.93 V (S), 2.63 V (R), and 2.32 V (Z).
Figure 9.
M41T83 hardware hookup
VCC
MCU
M41T83
VCC
VCC
(1)
IRQ1/FT/OUT
XI
(1)
RST
(1)
XO
IRQ2
VBAT
VSS
INT
Reset Input
Port
SCL
Serial Clock Line
SDA
Serial Data Line
SQW
32KHz CLKIN
AI11801
1. Open drain output.
Doc ID 12578 Rev 12
11/61
Operation
2
M41T82-M41T83
Operation
The M41T8x clock operates as a slave device on the serial bus. Access is obtained by
implementing a start condition followed by the correct slave address (D0h). The 32 bytes
contained in the device can then be accessed sequentially in the following order:
●
1st byte: tenths/hundredths of a second register
●
2nd byte: seconds register
●
3rd byte: minutes register
●
4th byte: century/hours register
●
5th byte: day register
●
6th byte: date register
●
7th byte: month register
●
8th byte: year register
●
9th byte: digital calibration register
●
10th byte: watchdog register
●
11th - 15th bytes: alarm 1 registers
●
16th byte: flags register
●
17th byte: timer value register
●
18th byte: timer control register
●
19th byte: analog calibration register
●
20th byte: square wave register
●
21st - 25th bytes: alarm 2 registers
●
26th - 32nd bytes: user RAM
The M41T8x clock continually monitors VCC for an out-of-tolerance condition. Should VCC
fall below VRST, the device terminates an access in progress and resets the device address
counter. Inputs to the device will not be recognized at this time to prevent erroneous data
from being written to the device from an out-of-tolerance system. The power input will also
be switched from the VCC pin to the battery when VCC falls below the battery back-up
switchover voltage (VSO = VRST). At this time the clock registers will be maintained by the
attached battery supply. As system power returns and VCC rises above VSO, the battery is
disconnected, and the power supply is switched to external VCC.
12/61
Doc ID 12578 Rev 12
M41T82-M41T83
2.1
Operation
2-wire bus characteristics
The bus is intended for communication between different ICs. It consists of two lines: a bidirectional data signal (SDA) and a clock signal (SCL). Both the SDA and SCL lines must be
connected to a positive supply voltage via a pull-up resistor.
The following protocol has been defined:
●
Data transfer may be initiated only when the bus is not busy.
●
During data transfer, the data line must remain stable whenever the clock line is high.
●
Changes in the data line, while the clock line is high, will be interpreted as control
signals.
Accordingly, the following bus conditions have been defined:
2.1.1
Bus not busy
Both data and clock lines remain high.
2.1.2
Start data transfer
A change in the state of the data line, from high to low, while the clock is high, defines the
START condition.
2.1.3
Stop data transfer
A change in the state of the data line, from low to high, while the clock is high, defines the
STOP condition.
2.1.4
Data valid
The state of the data line represents valid data when after a start condition, the data line is
stable for the duration of the high period of the clock signal. The data on the line may be
changed during the low period of the clock signal. There is one clock pulse per bit of data.
Each data transfer is initiated with a start condition and terminated with a stop condition.
The number of data bytes transferred between the start and stop conditions is not limited.
The information is transmitted byte-wide and each receiver acknowledges with a ninth bit.
By definition a device that gives out a message is called “transmitter,” the receiving device
that gets the message is called “receiver.” The device that controls the message is called
“master.” The devices that are controlled by the master are called “slaves.”
Doc ID 12578 Rev 12
13/61
Operation
2.1.5
M41T82-M41T83
Acknowledge
Each byte of eight bits is followed by one acknowledge bit. This acknowledge bit is a low
level put on the bus by the receiver whereas the master generates an extra acknowledge
related clock pulse. A slave receiver which is addressed is obliged to generate an
acknowledge after the reception of each byte that has been clocked out of the slave
transmitter.
The device that acknowledges has to pull down the SDA line during the acknowledge clock
pulse in such a way that the SDA line is a stable low during the high period of the
acknowledge related clock pulse. Of course, setup and hold times must be taken into
account. A master receiver must signal an end of data to the slave transmitter by not
generating an acknowledge on the last byte that has been clocked out of the slave. In this
case the transmitter must leave the data line high to enable the master to generate the
STOP condition.
Figure 10. Serial bus data transfer sequence
DATA LINE
STABLE
DATA VALID
CLOCK
DATA
START
CONDITION
CHANGE OF
DATA ALLOWED
STOP
CONDITION
AI00587
Figure 11. Acknowledgement sequence
CLOCK PULSE FOR
ACKNOWLEDGEMENT
START
SCL FROM
MASTER
DATA OUTPUT
BY TRANSMITTER
1
2
MSB
8
9
LSB
DATA OUTPUT
BY RECEIVER
AI00601
14/61
Doc ID 12578 Rev 12
M41T82-M41T83
Read mode
In this mode the master reads the M41T8x slave after setting the slave address (see
Figure 13 on page 16). Following the WRITE mode control bit (R/W = 0) and the
acknowledge bit, the word address 'An' is written to the on-chip address pointer. Next the
START condition and slave address are repeated followed by the READ mode control bit
(R/W = 1). At this point the master transmitter becomes the master receiver. The data byte
which was addressed will be transmitted and the master receiver will send an acknowledge
bit to the slave transmitter. The address pointer is only incremented on reception of an
acknowledge clock. The M41T8x slave transmitter will now place the data byte at address
An+1 on the bus, the master receiver reads and acknowledges the new byte and the
address pointer is incremented to An+2.
This cycle of reading consecutive addresses will continue until the master receiver sends a
STOP condition to the slave transmitter. Most of the registers and memory locations are
accessed directly, but the RTC counters are accessed via a set of buffer/transfer registers at
addresses 00h to 07h. The counters are not directly read nor written. Instead, at the start of
a read or write cycle, the counters are copied into the eight buffer/transfer registers so that
the user can read them out sequentially, receiving a coherent set of data, copied from the
same instant in time.
An alternate READ mode may also be implemented whereby the master reads the M41T8x
slave without first writing to the (volatile) address pointer. The first address that is read is the
last one stored in the pointer (see Figure 14 on page 16).
Figure 12. Slave address location
R/W
SLAVE ADDRESS
START
1
A
LSB
MSB
2.2
Operation
1
0
1
0
0
0
AI00602
Doc ID 12578 Rev 12
15/61
Operation
M41T82-M41T83
R/W
DATA n+1
ACK
DATA n
ACK
BUS ACTIVITY:
S
ACK
ACK
WORD
ADDRESS (An)
ACK
S
START
SDA LINE
R/W
BUS ACTIVITY:
MASTER
START
Figure 13. Read mode sequence
SLAVE
ADDRESS
STOP
SLAVE
ADDRESS
P
NO ACK
DATA n+X
AI00899
STOP
DATA n+X
SLAVE
ADDRESS
16/61
ACK
BUS ACTIVITY:
DATA n+1
ACK
DATA n
P
NO ACK
R/W
S
ACK
SDA LINE
ACK
BUS ACTIVITY:
MASTER
START
Figure 14. Alternative read mode sequence
AI00895
Doc ID 12578 Rev 12
M41T82-M41T83
2.3
Operation
Write mode
In this mode the master transmitter transmits to the M41T8x slave receiver. Bus protocol is
shown in Figure 15. Following the START condition and slave address, a logic 0 (R/W = 0) is
placed on the bus and indicates to the addressed device that word address “An” will follow
and is to be written to the on-chip address pointer. The data word to be written to the
memory is strobed in next and the internal address pointer is incremented to the next
address location on the reception of an acknowledge clock. The M41T8x slave receiver will
send an acknowledge clock to the master transmitter after it has received the slave address
see Figure 12 on page 15 and again after it has received the word address and each data
byte.
STOP
SLAVE
ADDRESS
DATA n+X
P
ACK
DATA n+1
ACK
BUS ACTIVITY:
DATA n
ACK
WORD
ADDRESS (An)
ACK
S
R/W
SDA LINE
ACK
BUS ACTIVITY:
MASTER
START
Figure 15. Write mode sequence
AI00591
As in the case of reading, some registers and memory locations are written directly, but the
RTC counters are written via a set of eight buffer/transfer registers at addresses 00h to 07h.
The user will write the date and time information sequentially, and then, at the end of the I2C
write cycle or when the address pointer increments beyond 07h, the buffer/transfer registers
will be copied into the RTC counters. All the time parameters - fractions, seconds, minutes,
hours, day, date, month, year, and century bits - are copied simultaneously.
Whatever value is in the buffer/transfer registers will be copied to the counters, so if the user
only changes one of the eight bytes, the remaining seven bytes will receive the unchanged
contents of the buffer/transfer registers, which will contain whatever was in the counters at
the start of the write access.
For example, if the user starts a write cycle on Monday, November 16, 2009, at 17:52:27.03,
and writes a 22 to the minutes registers, the value Monday, November 16, 2009,
17:52:22.03 will be written back into the counters. At the start of the write cycle, the eight
bytes of counters were copied into the buffer/transfer registers. Then, the seconds register
was overwritten. Finally, the eight bytes were copied back into the counters with the result
that the seconds value was changed.
Doc ID 12578 Rev 12
17/61
Operation
2.4
M41T82-M41T83
Data retention and battery switchover (VSO = VRST)
Once VCC falls below the switchover voltage (VSO = VRST), the device automatically
switches over to the battery and powers down into an ultra low current mode of operation to
preserve battery life. If VBAT is less than, or greater than VRST, the device power is switched
from VCC to VBAT when VCC drops below VRST (see Figure 26 on page 50). At this time the
clock registers and user RAM will be maintained by the attached battery supply.
When it is powered back up, the device switches back from battery to VCC at VSO +
hysteresis. When VCC rises above VRST, it will recognize the inputs. For more information
on battery storage life refer to Application Note AN1012.
2.5
Power-on reset (trec)
The M41T8x continuously monitors VCC. When VCC falls to the power fail detect trip point,
the RST output pulls low (open drain) and remains low after power-up for trec (210 ms
typical) after VCC rises above VRST (max).
Note:
The trec period does not affect the RTC operation. Write protect only occurs when VCC is
below VRST. When VCC rises above VRST, the RTC will be selectable immediately. Only the
RST output is affected by the trec period.
The RST pin is an open drain output and an appropriate pull-up resistor to VCC should be
chosen to control the rise time.
18/61
Doc ID 12578 Rev 12
M41T82-M41T83
3
Clock operation
Clock operation
The M41T8x is driven by a quartz-controlled oscillator with a nominal frequency of
32.768 kHz. The accuracy of the real-time clock depends on the frequency of the quartz
crystal that is used as the time-base for the RTC.
The 8-byte clock register (see Table 2 on page 21 and Table 4 on page 23) is used to both
set the clock and to read the date and time from the clock, in binary coded decimal format.
Tenths/hundredths of seconds, seconds, minutes, and hours are contained within the first
four registers.
Bit D7 of register 01h contains the STOP bit (ST). Setting this bit to a '1' will cause the
oscillator to stop. When reset to a 0 the oscillator restarts within one second (typical).
Note:
Upon initial power-up, the user should set the ST bit to a '1,' then immediately reset the ST
bit to 0. This provides an additional “kick-start” to the oscillator circuit.
Bits D6 and D7 of clock register 03h (century/ hours register) contain the CENTURY bit 0
(CB0) and CENTURY bit 1 (CB1). Bits D0 through D2 of register 04h contain the day (day of
week). Registers 05h, 06h, and 07h contain the date (day of month), month, and years. The
ninth clock register is the digital calibration register, while the analog calibration register is
found at address 12h (these are both described in Section 3.4: Clock calibration). The RTC
includes an oscillator fail detect circuit which sets the OF bit in the flags register (bit 2,
register 0fh). For the M41T83, bit D7 of register 09h (watchdog register) contains the
oscillator fail interrupt enable bit (OFIE) which can be used to enable an interrupt when the
OF bit is set (see Section 3.12: Oscillator fail detection on page 40) will also generate an
interrupt output.
Note:
A WRITE to ANY location within the first eight bytes of the clock register (00h-07h),
including the ST bit and CB0-CB1 bits will result in an update of the RTC counters and a
reset of the divider chain. This could result in an inadvertent change of the current time. For
example, the ST bit is in the seconds register (address 01h) and the century bits (CB0-CB1)
are in the hours register (address 03h), so the user should take care to not alter these other
parameters when changing the ST bit or the century bits.
The eight clock registers may be read one byte at a time or in a sequential block. At the start
of a read cycle, a copy of the time/date counters is placed in the buffer/transfer registers and
can then be transferred out sequentially without concern that the time/date increments
during the transfer and thus yields a corrupt value. For example, if the user were to read the
seconds register, then start another bus cycle to read the minutes register, the minutes
counter could have incremented during the time between the two read cycles. The seconds
and minutes values would not be from the same instant in time; they would not be coherent.
By using the sequential read feature, the values shifted out are from the same instant in time
and are thus coherent.
Similarly, when writing to the RTC registers, during one write cycle, the user can
sequentially transfer all eight bytes of time/date into the buffer/transfer registers whereupon
they will be loaded simultaneously into the RTC counters thus ensuring a coherent update
of the time/date.
Doc ID 12578 Rev 12
19/61
Clock operation
3.1
M41T82-M41T83
Power-down time-stamp
When a power failure occurs, the time/date counters are copied into the buffer/transfer
registers and the halt update bit (HT) is automatically set to a "1". The HT bit prevents the
normal copying from counters to registers which occurs at the start of a read or write cycle.
Thus, upon power-up, the user can read the RTC registers to ascertain the time of powerdown. Additional reads will return the same time. It will appear to be frozen until the HT bit
(D6, address 0Ch) is written to 0 by the user. Then, subsequent reads will then return the
current time. For more information, see application notes AN1572 and AN3060.
Note:
Writes to the RTC registers (addresses 00h to 07h) with the HT bit set can cause time
corruption. Example: Assume a power-fail time of Monday, November 16, 2009, at
17:52:27.03. At the next power-up, that time will be frozen in the buffer/transfer registers.
On November 17, 2009, at 16:15:07.77, the user powers the system back up and tries to
write the seconds to 35 while the HT bit is still set. This will cause Monday, November 16,
2009, at 17:52:35.03 to be written into the counters because the other seven bytes of
buffer/transfer register still contain the time of power-down. The result is that the modified
time of power-down was written into the counters making it appear the part had lost time
while power was off. Thus, at power-up, the user should always clear the HT bit (write D6 to
0 in address 0Ch) before writing to any address in the range 00h to 07h.
A typical power-up flow is to read the time of power-down, then clear the HT bit, then read
the current time. If the time of power-down is not needed by the application, then the first
step can be omitted.
3.2
Clock/control register map and divider chain
The M41T8x is comprised of 32 addresses which contain registers for clock (time and date),
calibration (digital and analog), alarm 1 and 2, watchdog, flags, timer, and square wave
(M41T83 only). Clock and alarm registers store data in BCD format. Calibration, timer,
watchdog, and square wave bits are written in a binary format.
Whenever any of the eight RTC bytes (addresses 00h to 07h) are written, the internal divider
(or clock) chain will be reset upon the completion of the write cycle.
20/61
Doc ID 12578 Rev 12
M41T82-M41T83
Table 2.
Clock operation
M41T82 clock/control register map (32 bytes)(1)
Addr
D7
00h
D6
D5
D4
D3
D2
0.1 seconds
D1
D0
Function/range BCD
format
0.01 seconds
seconds
00-99
01h
ST
10 seconds
seconds
seconds
00-59
02h
0
10 minutes
minutes
minutes
00-59
03h
CB1
CB0
Hours (24 hour format)
Century/hours
0-3/00-23
04h
0
0
Day
01-7
05h
0
0
Date: day of month
Date
01-31
06h
0
0
Month
Month
01-12
Year
Year
00-99
07h
10 hours
0
0
0
10 date
0
Day of week
10M
10 years
08h
0
FT
DCS
DC4
DC3
DC2
DC1
DC0
Digital calibration
09h
0
BMB4
BMB3
BMB2
BMB1
BMB0
RB1
RB0
Watchdog
0Ah
0
0
ABE
Al1 10M
0Bh
RPT14
RPT15
0Ch
RPT13
HT
0Dh
RPT12
0Eh
RPT11
0Fh
WDF
Alarm1 month
Al1 month
01-12
AI1 10 date
Alarm1 date
Al1 date
01-31
AI1 10 hour
Alarm1 hour
Al1 hour
00-23
Alarm1 10 minutes
Alarm1 minutes
Al1 min
00-59
Alarm1 10 seconds
Alarm1 seconds
Al1 sec
00-59
AF1
(2)
AF2
10h
BL
TF
OF
0
0
Timer countdown value
Flags
Timer value
11h
TE
0
0
0
0
0
TD1
TD0
Timer control
12h
ACS
AC6
AC5
AC4
AC3
AC2
AC1
AC0
Analog calibration
13h
0
0
0
0
0
0
AL2E
0
SQW
14h
(3)
0(3)
0(3)
Al2 10M
0
Alarm2 month
SRAM/Al2 month
01-12
15h
RPT24
RPT25
AI2 10 date
Alarm2 month
SRAM/Al2 date
01-31
16h
RPT23
0(3)
AI2 10 hour
Alarm2 date
SRAM/Al2 hour
00-23
17h
RPT22
Alarm2 10 minutes
Alarm2 minutes
SRAM/Al2 min
00-59
18h
RPT21
Alarm2 10 seconds
Alarm2 seconds
SRAM/Al2 sec
00-59
19h-1Fh
User SRAM (7 bytes)
SRAM
1. See Table 3: Key to Table 2: M41T82 clock/control register map (32 bytes)
2. AF2 will always read 0, if the AL2E bit is set to 0.
3. As indicated in Table 3, the 0 bits should be written to 0. But in the case of these four bits, when AL2E is 0, registers 14-18h
are SRAM locations and these bits become SRAM cells which are thus excluded from that restriction.
Doc ID 12578 Rev 12
21/61
Clock operation
Table 3.
M41T82-M41T83
Key to Table 2: M41T82 clock/control register map (32 bytes)
Code
22/61
Explanation
0
Must be set to zero
ABE
Alarm in battery backup enable bit
AC0-AC6
Analog calibration bits
ACS
Analog calibration sign bit
AF1, AF2
Alarm flag bits
AL2E
Alarm 2 enable bit
BL
Battery low bit
BMB0-BMB4
Watchdog multiplier bits
CB0, CB1
Century bits
DC0-DC4
Digital calibration bits
DCS
Digital calibration sign bit
FT
Frequency test bit
HT
Halt update bit
OF
Oscillator fail bit
RB0-RB2
Watchdog resolution bits
RPT11-RPT15
Alarm 1 repeat mode bits
RPT21-RPT25
Alarm 2 repeat mode bits
ST
Stop bit
TD0, TD1
Timer frequency bits
TE
Timer enable bit
TF
Timer flag
WDF
Watchdog flag
Doc ID 12578 Rev 12
M41T82-M41T83
Clock operation
M41T83 clock/control register map (32 bytes)(1)
Table 4.
Addr
D7
00h
D6
D5
D4
D3
D2
0.1 seconds
D1
D0
Function/range BCD
format
0.01 seconds
seconds
00-99
01h
ST
10 seconds
seconds
seconds
00-59
02h
0
10 minutes
Minutes
Minutes
00-59
03h
CB1
CB0
Hours (24 hour format)
Century/hours
0-3/00-23
04h
0
0
Day
01-7
05h
0
0
Date: day of month
Date
01-31
06h
0
0
Month
Month
01-12
Year
Year
00-99
07h
10 hours
0
0
0
10 date
0
Day of week
10M
10 years
08h
OUT
FT
DCS
DC4
DC3
DC2
DC1
DC0
Digital calibration
09h
OFIE
BMB4
BMB3
BMB2
BMB1
BMB0
RB1
RB0
Watchdog
0Ah
A1IE
SQWE
ABE
Al1
10M
0Bh
RPT14
RPT15
0Ch
RPT13
HT
0Dh
RPT12
0Eh
RPT11
0Fh
WDF
Alarm 1month
Al1 month
01-12
AI1 10 date
Alarm1 date
Al1 date
01-31
AI1 10 hour
Alarm1 hour
Al1 hour
00-23
Alarm1 10 minutes
Alarm1 minutes
Al1 min
00-59
Alarm1 10 seconds
Alarm1 seconds
Al1 sec
00-59
AF1
AF2(2)
10h
BL
TF
OF
0
0
Timer countdown value
Flags
Timer value
11h
TE
TI/TP
TIE
0
0
0
TD1
TD0
Timer control
12h
ACS
AC6
AC5
AC4
AC3
AC2
AC1
AC0
Analog
calibration
13h
RS3
RS2
RS1
RS0
0
0
AL2E
OTP
SQW
14h
A2IE
0(3)
0(3)
Al2
10M
15h
RPT24
RPT25
SRAM/Al2 month
01-12
AI2 10 date
Alarm2 date
SRAM/Al2 date
01-31
AI2 10 hour
Alarm2 hour
SRAM/Al2 hour
00-23
16h
RPT23
17h
RPT22
Alarm2 10 minutes
Alarm2 minutes
SRAM/Al2 min
00-59
18h
RPT21
Alarm2 10 seconds
Alarm2 seconds
SRAM/Al2 sec
00-59
19h1Fh
0
(3)
Alarm2 month
User SRAM (7 bytes)
SRAM
1. See Table 5: Key to Table 4: M41T83 clock/control register map (32 bytes).
2. AF2 will always read 0, if the AL2E bit is set to 0.
3. As indicated in Table 5, the 0 bits should be written to 0. But in the case of these three bits, when AL2E is 0, registers
14-18h are SRAM locations and these bits become SRAM cells which are thus excluded from that restriction.
Doc ID 12578 Rev 12
23/61
Clock operation
Table 5.
M41T82-M41T83
Key to Table 4: M41T83 clock/control register map (32 bytes)
Code
24/61
Explanation
0
Must be set to zero
ABE
Alarm in battery back-up enable bit
A1IE, A2IE
Alarm interrupt enable bits
AC0-AC6
Analog calibration bits
ACS
Analog calibration sign bit
AF1, AF2
Alarm flag
AL2E
Alarm 2 enable bit
BL
Battery low bit
BMB0-BMB4
Watchdog multiplier bits
CB0, CB1
Century bits
DC0-DC4
Digital calibration bits
DCS
Digital calibration Sign bit
FT
Frequency test bit
HT
Halt update bit
OF
Oscillator fail bit
OUT
Output level
OFIE
Oscillator fail interrupt enable
OTP
OTP control bit
RB0-RB2
Watchdog resolution bits
RPT11-RPT15
Alarm 1 repeat mode bits
RPT21-RPT25
Alarm 2 repeat mode bits
RS0-RS3
SQW frequency
SQWE
Square wave enable
SRAM/ALM2
SRAM/alarm 2 bit
ST
Stop bit
TD0, TD1
Timer frequency bits
TE
Timer enable bit
TF
Timer flag
TI/TP
Timer interrupt or pulse
TIE
Timer interrupt enable
WDF
Watchdog flag
Doc ID 12578 Rev 12
M41T82-M41T83
3.3
Clock operation
Real-time clock accuracy
The M41T8x is driven by a quartz controlled oscillator with a nominal frequency of
32,768 Hz. The accuracy of the real-time clock is dependent upon the accuracy of the
crystal, and the match between the capacitive load of the oscillator circuit and the capacitive
load for which the crystal was trimmed. Temperature also affects the crystal frequency,
causing additional error (see Figure 17 on page 30).
The M41T8x provides the option of clock correction through either manufacturing calibration
or in-application calibration. The total possible compensation is typically –93 ppm to +156
ppm. The two compensation circuits that are available are:
1.
An analog calibration register (12h) can be used to adjust internal (on-chip) load
capacitors for oscillator capacitance trimming. The individual load capacitors CXI and
CXO (see Figure 16), are selectable from a range of –18 pF to +9.75 pF in steps of
0.25 pF. This translates to a calculated compensation of approximately ±30 ppm (see
Section 3.4.2: Analog calibration (programmable load capacitance) on page 29).
2.
A digital calibration register (08h) can also be used to adjust the clock counter by
adding or subtracting a pulse at the 512 Hz divider stage. This approach provides
periodic compensation of approximately –63 ppm to +126 ppm (see Section 3.4.1:
Digital calibration (periodic counter correction) on page 26).
Figure 16. Internal load capacitance adjustment
XI
CXI
Crystal Oscillator
XO
CXO
AI11804
Doc ID 12578 Rev 12
25/61
Clock operation
3.4
M41T82-M41T83
Clock calibration
The M41T8x oscillator is designed for use with a 12.5 pF crystal load capacitance. When
the calibration circuit is properly employed, accuracy improves to better than ±1 ppm at
25 °C.
The M41T8x design provides the following two methods for clock error correction.
3.4.1
Digital calibration (periodic counter correction)
This method employs the use of periodic counter correction by adjusting the ratio of the
100 Hz divider stage to the 512 Hz divider stage. Under normal operation, the 100 Hz
divider stage outputs precisely 100 pulses for every 512 pulses of the 512 Hz input stage to
provide the input frequency to the fraction of seconds clock register. By adjusting the
number of 512 Hz input pulses used to generate 100 output pulses, the clock can be sped
up or slowed down, as shown in Figure 19 on page 32.
When a non-zero value is loaded into the five calibration bits (DC4 – DC0) found in the
digital calibration register (08h) and the sign bit is 1, (indicating positive calibration), the
100 Hz stage outputs 100 pulses for every 511 input pulses instead of the normal 512.
Since the 100 pulses are now being output in a shorter window, this has the effect of
speeding up the clock by 1/512 seconds for each second the circuit is active. Similarly, when
the sign bit is 0, indicating negative calibration, the block outputs 100 pulses for every 513
input pulses. Since the 100 pulses are then being output in a longer window, this has the
effect of slowing down the clock by 1/512 seconds for each second the circuit is active.
The amount of calibration is controlled by using the value in the calibration register (N) to
generate the adjustment in one second increments. This is done for the first N seconds once
every eight minutes for positive calibration, and for N seconds once every sixteen minutes
for negative calibration (see Table 6 on page 28).
For example, if the calibration register is set to 100010, then the adjustment will occur for
two seconds in every minute. Similarly, if the calibration register is set to 000011, then the
adjustment will occur for 3 seconds in every alternating minute.
The digital calibration bits (DC4 – DC0) occupy the five lower order bits in the digital
calibration register (08h). These bits can be set to represent any value between 0 and 31 in
binary form. The sixth bit (DCS) is a sign bit; 1 indicates positive calibration, 0 indicates
negative calibration. Calibration occurs within an 8-minute (positive) or 16-minute (negative)
cycle. Therefore, each calibration step has an effect on clock accuracy of +4.068 or –2.034
ppm. Assuming that the oscillator is running at exactly 32,768 Hz, each of the 31 increments
in the calibration byte would represent +10.7 or –5.35 seconds per month, which
corresponds to a total range of +5.5 or –2.75 minutes per month.
One method of determining the amount of digital calibration required is to use the frequency
test output (FT) of the device (see Section 3.14: IRQ1/FT/OUT pin, frequency test,
interrupts and the OUT bit (M41T83 only) on page 41 for more information on enabling the
FT output).
When FT is enabled, a 512 Hz signal is output in the IRQ1/FT/OUT pin on the M41T83, and
on the FT/RST pin on the M41T82. This signal can be measured using a highly accurate
timing device such as a frequency counter. The measured value is then compared to 512 Hz
and the oscillator error in ppm is then determined.
The user should keep in mind that changes in the digital calibration value will not affect the
signal measured on the FT pin. While the analog calibration circuit does affect the oscillator,
26/61
Doc ID 12578 Rev 12
M41T82-M41T83
Clock operation
the digital calibration circuitry uses periodic counter correction which occurs downstream of
the 512 Hz divider chain and hence has no effect on the FT pin.
Note:
1
The modified pulses are not observable on the frequency test (FT) output, nor will the effect
of the calibration be measurable real-time, due to the periodic nature of the error
compensation.
2
Positive digital calibration is performed on an eight minute cycle, therefore the value in the
calibration register should not be modified more frequently than once every eight minutes for
positive values of calibration. Negative digital calibration is performed on a sixteen minute
cycle, therefore negative values in the calibration register should not be modified more
frequently than once every sixteen minutes.
Doc ID 12578 Rev 12
27/61
Clock operation
Table 6.
28/61
M41T82-M41T83
Digital calibration values
Calibration value (binary)
Calibration value rounded to the nearest ppm
DC4 – DC0
Negative calibration (DCS = 0) Positive calibration (DCS = 1)
to speed up a slow clock
to slow a fast clock
0 (00000)
0
0
1 (00001)
–2
4
2 (00010)
–4
8
3 (00011)
–6
12
4 (00100)
–8
16
5 (00101)
–10
20
6 (00110)
–12
24
7 (00111)
–14
28
8 (01000)
–16
33
9 (01001)
–18
37
10 (01010)
–20
41
11 (01011)
–22
45
12 (01100)
–24
49
13 (01101)
–26
53
14 (01110)
–28
57
15 (01111)
–31
61
16 (10000)
–33
65
17 (10001)
–35
69
18 (10010)
–37
73
19 (10011)
–39
77
20 (10100)
–41
81
21 (10101)
–43
85
22 (10110)
–45
90
23 (10111)
–47
94
24 (11000)
–49
98
25 (11001)
–51
102
26 (11010)
–53
106
27 (11011)
–55
110
28 (11100)
–57
114
29 (11101)
–59
118
30 (11110)
–61
122
31 (11111)
–63
126
N
N/491520 (per minute)
N/245760 (per minute)
Doc ID 12578 Rev 12
M41T82-M41T83
3.4.2
Clock operation
Analog calibration (programmable load capacitance)
A second method of calibration employs the use of programmable internal load capacitors to
adjust (or trim) the oscillator frequency. As discussed in Section 3.4.1, the 512 Hz frequency
test output can be used to determine the amount of frequency error in the oscillator.
Changes in the analog calibration value will affect the frequency test output, thus the user
can immediately see the effects of these changes (see Section 3.14 on page 41 for more
information on enabling the FT output).
By design, the oscillator is intended to be 0 ppm ± crystal accuracy at room temperature
(25 °C, see Figure 17 on page 30). For a 12.5 pF crystal, the default loading on each side of
the crystal will be 25 pF. For incrementing or decrementing the calibration value,
capacitance will be added or removed in increments of 0.25 pF to each side of the crystal.
Internally, CLOAD of the oscillator is changed via two digitally controlled capacitors, CXI and
CXO, connected from the XI and XO pins to ground (see Figure 16 on page 25). The
effective on-chip series load capacitance, CLOAD, ranges from 3.5 pF to 17.4 pF, with a
nominal value of 12.5 pF (AC0 – AC6 = 0).
The effective series load capacitance (CLOAD) is the combination of CXI and CXO:
C LOAD = 1 ⁄ ( 1 ⁄ C XI + 1 ⁄ C XO )
Seven analog calibration bits, AC0 to AC6, are provided in order to adjust the on-chip load
capacitance value for frequency compensation of the RTC. Each bit has a different weight
for capacitance adjustment. An analog calibration sign (ACS) bit determines if capacitance
is added (ACS bit = 0, negative calibration) or removed (ACS bit = 1, positive calibration).
The majority of the calibration adjustment is positive (i.e. to increase the oscillator frequency
by removing capacitance) due to the typical characteristic of quartz crystals to slow down
due to changes in temperature, but negative calibration is also available.
Since the analog calibration register adjustment is essentially pulling the frequency of the
oscillator, the resulting frequency changes will not be linear with incremental capacitance
changes. The equations which govern this mechanism indicate that smaller capacitor values
of analog calibration adjustment will provide larger increments. Thus, the larger values of
analog calibration adjustment will produce smaller incremental frequency changes. These
values typically vary from 6-10 ppm/bit at the low end to <1 ppm/bit at the highest
capacitance settings. The range provided by the analog calibration register adjustment with
a typical surface mount crystal is approximately ±30 ppm around the AC6-AC0 = 0 default
setting because of this property (see Table 7 on page 30).
Pre-programmed calibration value
Users of the M41T83 in the embedded crystal package have the option of using the factory
programmed analog calibration value (refer to Section 3.17: OTP bit operation (M41T83 in
SOX18 package only) on page 45).
Doc ID 12578 Rev 12
29/61
Clock operation
M41T82-M41T83
Figure 17. Crystal accuracy across temperature
Frequency (ppm)
20
0
–20
–40
–60
ΔF = K x (T – T )2
O
F
–80
2
2
K = –0.036 ppm/°C ± 0.006 ppm/°C
–100
TO = 25°C ± 5°C
–120
–140
–160
–40
–30
–20
–10
0
10
20
30
40
50
60
70
80
Temperature °C
Table 7.
Addr
AI07888
Analog calibration values
Analog
calibration
value
D7
D6
D5
D4
D3
D2
D1
D0
ACS
AC6
AC5
AC4
AC3
AC2
AC1
AC0
(±)
(16 pF) (8 pF)
CXI, CXO
CLOAD(1)
½(CXI, CXO)
(4 pF) (2 pF) (1 pF) (0.5 pF) (0.25 pF)
0 pF
x
0
0
0
0
0
0
0
25 pF
12.5 pF
3 pF
0
0
0
0
1
1
0
0
28 pF
14 pF
5 pF
0
0
0
1
0
1
0
0
30 pF
15 pF
–7 pF
1
0
0
1
1
1
0
0
18 pF
9 pF
9.75 pF(2)
0
0
1
0
0
1
1
1
34.75 pF
17.4 pF
(3)
1
1
0
0
1
0
0
0
7 pF
3.5 pF
12h
–18 pF
1. CLOAD = 1/(1/CXI + 1/CXO).
2. Maximum negative calibration value.
3. Maximum positive calibration value.
30/61
Doc ID 12578 Rev 12
M41T82-M41T83
Clock operation
The on-chip capacitance can be calculated as follows:
CLOAD =
1
[ ACS (AC6 : AC0 value, decimal)⋅ 0.25+ 25] pF
2
where ACS is the sign.
For example:
●
CLOAD (12h = x0000000) = 12.5 pF
●
CLOAD (12h =11001000) = 3.5 pF (sign is negative)
●
CLOAD (12h = 00100111) = 17.4 pF
With the analog calibration adjusted to its lowest value, the oscillator will see a minimum of
3.5 pF load capacitance as shown on the bottom row of Table 7.
Note:
These are typical values, and the total load capacitance seen by the crystal will include
approximately 1-2 pF of package and board capacitance in addition to the analog calibration
register value.
Any invalid value of analog calibration will result in the default capacitance of 25 pF.
The combination of analog and digital trimming can give up to –93 to +156 ppm of the total
adjustment.
Figure 18 represents a typical curve of clock ppm adjustment versus the analog calibration
value. This curve may vary with different crystals, so it is good practice to evaluate the
crystal to be used with an M41T8x device before establishing the adjustment values for the
application in question.
Figure 18. Clock accuracy vs. on-chip load capacitance
100.0
XI
XO
PPM ADJUSTMENT
80.0
Crystal
Oscillator
60.0
CXI
CXO
40.0
CLOAD =
20.0
CXI * CXO
CXI + CXO
On-Chip
FASTER
DECREASING LOAD CAP.
INCREASING LOAD CAP.
0.0
SLOWER
-20.0
OFFSET TO
CXI, CXO (pF)
NET EQUIV. LOAD
CAP., C LOAD, (pF)
Analog Calibration
Value, AC,
register 0x12
-18.0 -15.0
3.5
5.0
0xC8 0xBC
-10.0
-5.0
0.0
5.0
9.75
7.5
10
12.5
15
17.4
0xA8
0x94
0x00
0x14
0x27
ai13906
Doc ID 12578 Rev 12
31/61
Clock operation
M41T82-M41T83
Two methods are available for ascertaining how much calibration a given M41T8x may
require:
●
The first involves setting the clock, letting it run for a month and comparing it to a known
accurate reference and recording deviation over a fixed period of time. This allows the
designer to give the end user the ability to calibrate the clock as the environment
requires, even if the final product is packaged in a non-user serviceable enclosure. The
designer could provide a simple utility that accesses either or both of the calibration
bytes.
●
The second approach is better suited to a manufacturing environment, and uses the
512 Hz frequency test output. This is the IRQ1/FT/OUT pin on the M41T83, and the
FT/RST pin on the M41T82 (see Section 3.14 and Section 3.15 for more information on
enabling the FT output). The 512 Hz frequency test signal can be measured using a
highly accurate timing device such as a frequency counter. The measured value is then
compared to 512 Hz and the oscillator error in ppm is then determined.
Any deviation from 512 Hz indicates the degree and direction of oscillator frequency
shift at the test temperature. For example, a reading of 512.010124 Hz would indicate a
+20 ppm oscillator frequency error, requiring either a –10 (xx001010) to be loaded into
the digital calibration byte, or +6 pF (00011000) into the analog calibration byte for
correction.
Note:
Setting or changing the digital calibration byte does not affect the frequency test, square
wave, or watchdog timer frequency, but changing the analog calibration byte DOES affect all
functions derived from the low current oscillator (see Figure 19).
Figure 19. Clock divider chain and calibration circuits
512Hz Output
Frequency Test
÷64
Remainder of
Divider Circuit
÷2
CXI
Low Current
Oscillator
32KHz
÷64
Digital Calibration Circuitry
(divide by 511/512/513)
CXO
Clock
Counters
1Hz Signal
Analog Calibration
Circuitry
32/61
Square Wave
Watchdog Timer
8-bit Timer
Doc ID 12578 Rev 12
AI11806c
M41T82-M41T83
Clock operation
Figure 20. Crystal isolation example
Crystal
Local Grounding
Plane (Layer 2)
XI XO
VSS
AI11814
1. Substrate pad should be tied to VSS.
3.5
Setting the alarm clock registers
Codes not listed in the table default to the once-per-second mode to quickly alert the user of
an incorrect alarm setting. When the clock information matches the alarm clock settings
based on the match criteria defined by RPTx5–RPTx1 (x = 1 for alarm 1 or 2 for alarm 2),
the alarm flag, AFx, is set. Reading the flags register clears the alarm flags. A subsequent
read of the flags register is necessary to see that the value of the alarm flag has been reset
to 0.
M41T83 interrupts on alarm
In the M41T83, for alarm 1, setting the alarm interrupt enable, A1IE, allows an interrupt
output to be asserted upon AF1 being set provided that other configuration bits are set
accordingly (see Section 3.14 for more information on the IRQ/FT/OUT output).
Likewise for alarm 2, with A2IE set, IRQ2 will be asserted upon AF2 going high. To disable
either of the alarms, write a 0 to the alarm date registers and to the RPTx5–RPTx1 bits.
Note:
If the address pointer is allowed to increment to the flag register address, or the last address
written is “Alarm Seconds,” the address pointer will increment to the flag address, and an
alarm condition will not cause the interrupt/flag to occur until the address pointer is moved to
a different address.
Alarm IRQ outputs are de-asserted when the alarm flags are cleared by reading the flags
register (0Fh).
The IRQ1/FT/OUT pin can also be activated in the battery backup mode. This requires the
ABE bit (alarm in backup enable) to be set (see Section 3.14.2: Backup mode for additional
conditions which apply). Once an interrupt is asserted in backup mode, it will remain true
until VCC is restored and a subsequent read of the flags register occurs.
Doc ID 12578 Rev 12
33/61
Clock operation
3.6
M41T82-M41T83
Optional second programmable alarm and user SRAM
When the alarm 2 enable (AL2E) bit (D1 of address 13h) is set to a logic 1, registers 14h
through 18h provide control for a second programmable alarm which operates in the same
manner as the alarm function described in Section 3.5. The AL2E bit defaults on initial
power-up to a logic 0 (alarm 2 disabled). In this mode, the five alarm 2 bytes (14h-18h)
function as additional user SRAM, for a total of 12 bytes of user SRAM.
With AL2E set to 1, the alarm is enabled, and will cause the AF2 bit to be set when the
alarm condition is met. On the M41T83, if the A2IE (alarm 2 interrupt enable) bit is set, an
interrupt will be asserted on IRQ2. The interrupt is de-asserted when the alarm flags are
cleared by reading the flags register (0Fh).
IRQ2 can be enabled in backup mode by setting ABE to 1 (in conjuction with setting A2IE).
Table 8.
3.7
Alarm repeat modes
RPT5
RPT4
RPT3
RPT2
RPT1
Alarm setting
1
1
1
1
1
Once per second
1
1
1
1
0
Once per minute
1
1
1
0
0
Once per hour
1
1
0
0
0
Once per day
1
0
0
0
0
Once per month
0
0
0
0
0
Once per year
Watchdog timer
The watchdog timer can be used to detect an out-of-control microprocessor. The user
programs the watchdog timer by setting the desired amount of time-out into the watchdog
register, address 09h. Bits BMB4-BMB0 store a binary multiplier and the two lower order bits
RB1-RB0 select the resolution, where 00 = 1/16 second, 01 = 1/4 second, 10 = 1 second,
and 11 = 4 seconds. The amount of time-out is then determined to be the multiplication of
the five-bit multiplier value with the resolution. (For example: writing 00001110 in the
watchdog register = 3*1, or 3 seconds). If the processor does not reset the timer within the
specified period, the M41T8x sets the WDF (watchdog flag).
The watchdog timer is reset by writing to the watchdog register. The time-out period then
starts over.
M41T83 watchdog interrupt
On the M41T83, provided that the necessary configuration bits are set, the IRQ/FT/OUT
output will be asserted when the watchdog times out (see Section 3.14 for additional
conditions which apply).
Should the watchdog time out, to de-assert the IRQ1/FT/OUT output, the lower seven bits of
the watchdog register (09h) must be written. This will de-assert the output and re-initialize
the watchdog. Writing these seven bits to 0 will de-assert the output and disable the
watchdog.
34/61
Doc ID 12578 Rev 12
M41T82-M41T83
Clock operation
A READ of the flags register will reset the watchdog flag (bit D7; register 0Fh) but not deassert the IRQ1/FT/OUT output. The watchdog function is automatically disabled upon
power-up and the watchdog register is cleared.
Table 9.
3.8
Watchdog register
Addr
D7
D6
D5
D4
D3
D2
D1
D0
Function
09h
OFIE
BMB4
BMB3
BMB2
BMB1
BMB0
RB1
RB0
Watchdog
8-bit (countdown) timer
The timer value register is an 8-bit binary countdown timer. It is enabled and disabled via the
timer control register (11h) TE bit. Other timer properties such as the source clock, or
interrupt generation are also selected in the timer control register (see Table 10). For
accurate read back of the countdown value, the I2C-bus clock (SCL) must be operating at a
frequency of at least twice the selected timer clock.
The timer control register selects one of four source clock frequencies for the timer (4096,
64, 1, or 1/60 Hz), and enables/disables the timer. The timer counts down from a softwareloaded 8-bit binary value (register 10h) and decrements to 1. On the next tick of the counter,
it reloads the timer countdown value and sets the timer flag (TF) bit. The TF bit can only be
cleared by software. When asserted, the timer flag (TF) can also be used to generate an
interrupt (IRQ1/FT/OUT) on the M41T83. Writing the timer countdown value (10h) has no
effect on the TF bit or the IRQ1/FT/OUT output.
3.8.1
M41T83 timer interrupt/output
On the M41T83, there are two choices for the output depending on the TI/TP configuration
bit (timer interrupt/timer pulse, bit 6, register 11h).
Normal interrupt mode
With TI/TP = 0, the output will assert like a normal interrupt, staying low until the TF bit is
cleared by software by reading the flags register (0Fh).
Free-running mode
When TI/TP is a 1, the output is a free-running waveform as depicted in Figure 21. After
being low for the specified time (as shown in Table 11), the output automatically goes high
without need of software clearing any bits. The TF bit will still be set each time the timer
reloads, but it is not necessary for the software to clear it in this mode. Furthermore, clearing
the TF bit has no effect on the output in this mode.
While writes to the timer countdown register (10h) control the reload value, reads of this
register return the current countdown timer value.
Doc ID 12578 Rev 12
35/61
Clock operation
M41T82-M41T83
Timer control register map(1)
Table 10.
Addr
D7
D6
D5
D4
D3
0Fh
WDF
AF1
AF2
BL
TF
10h
Timer countdown value
11h
TE
TI/TP
TIE
0
D2
D1
D0
Function
OF
0
0
Flags
(2)
0
Timer value
0
TD1
TD0
Timer control
1. Bit positions labeled with 0 should always be written with logic 0.
2. Writing to the timer register will not reset the TF bit nor clear the interrupt.
When the timer is in the free-running mode, with a value of n programmed into the timer
countdown value, the output will nominally be low for one cycle of the specified clock source
and high for n-1 cycles with an overal period of n cycles. Thus, the countdown period is
n/source clock frequency.
For the special case of n = 1, as shown in Table 11, when the clock source is 4096 or 64 Hz,
the low time (TL) is half the clock period instead of a full clock period.
Table 11.
Timer interrupt operation in free-running mode (with TI/TP = 1)
IRQ low time – TL (seconds)(1)
Source clock (Hz)
n = 1(2)
n=1
n>1
1/8192 = 122 µs 1/4096 = 244 µs
1/4096 = 244 µs
n / 4096
64
1/128 = 7.8 ms
1/64 = 15.6 ms
1/64 = 15.6 ms
n / 64
1
1/64
1/64
1
n
1/60
1/64
1/64
1 minute
n minutes
4096
n>1
IRQ period – TIRQ (seconds)
1. IRQ1/FT/OUT is asserted coincident with TF going true.
2. n = loaded countdown timer value (0 < n < 255). The timer is stopped when n = 0.
Figure 21. Timer output waveform in free-running mode (with TI/TP = 1)
TIRQ
TL
IRQ1/FT/OUT
AM03012v1
36/61
Doc ID 12578 Rev 12
M41T82-M41T83
3.8.2
Clock operation
Timer flag (TF)
At the end of a timer countdown, when the timer reloads, TF is set to logic '1.' Regardless of
the state of TF bit (or TI/TP bit), the timer will continue decrementing and reloading.
If both timer and alarm interrupts are used in the application, the source of the interrupt can
be determined by reading the flag bits. Refer to Section 3.14 for more information on the
interaction of these bits. The TF bit is cleared by reading the flags register. This will deassert an interrupt output due to the timer.
3.8.3
Timer interrupt enable (TIE, M41T83 only)
In normal interrupt mode (TI/TP = 0), when TF is asserted, the interrupt output is asserted (if
TIE = 1). To de-assert the interrupt, the TF bit or the TIE bit must be reset. Disabling the
interrupt by clearing the TIE bit will de-assert the output, but does not clear the TF bit. Thus,
if TIE is re-enabled prior to clearing TF, the interrupt will assert immediately.
3.8.4
Timer enable (TE)
●
TE = 0
When the timer register (10h) is set to 0, the timer is disabled.
●
TE = 1
The timer is enabled. TE is reset (disabled) on power-down. When re-enabled, the
counter will begin counting from the same value as when it was disabled.
3.8.5
TD1/0
These are the timer source clock frequency selection bits (see Table 12). These bits
determine the source clock for the countdown timer (see Table 10 on page 36). When not in
use, the TD1 and TD0 bits should be set to 11 (1/60 Hz) for power saving.
Table 12.
3.9
Timer source clock frequency selection (244.1 µs to 4.25 hrs)
TD1
TD0
Timer source clock frequency (Hz)
0
0
4096 (244.1 µs)
0
1
64 (15.6 ms)
1
0
1 (1 s)
1
1
1/60 (60 s)
Square wave output (M41T83 only)
The M41T83 offers the user a programmable square wave function which is output on the
SQW pin. RS3-RS0 bits located in 13h establish the square wave output frequency. These
frequencies are listed in Table 13. Once the selection of the SQW frequency has been
completed, the SQW pin can be turned on and off under software control with the square
wave enable bit (SQWE) located in register 0Ah.
Note:
If the SQWE bit is set to '1' and VCC falls below the switchover (VSO) voltage, the square
wave output will be disabled.
Doc ID 12578 Rev 12
37/61
Clock operation
M41T82-M41T83
Table 13.
Square wave output frequency
Square wave bits
38/61
Square wave
RS3
RS2
RS1
RS0
Frequency
Units
0
0
0
0
None
–
0
0
0
1
32.768
kHz
0
0
1
0
8.192
kHz
0
0
1
1
4.096
kHz
0
1
0
0
2.048
kHz
0
1
0
1
1.024
kHz
0
1
1
0
512
Hz
0
1
1
1
256
Hz
1
0
0
0
128
Hz
1
0
0
1
64
Hz
1
0
1
0
32
Hz
1
0
1
1
16
Hz
1
1
0
0
8
Hz
1
1
0
1
4
Hz
1
1
1
0
2
Hz
1
1
1
1
1
Hz
Doc ID 12578 Rev 12
M41T82-M41T83
3.10
Clock operation
Battery low warning
The M41T8x automatically checks the battery each time VCC powers up and each time the
clock rolls over at midnight.
VBAT is compared to VBL (approximately 2.5 V), then the battery low (BL) bit, D4 of flags
register 0Fh, is set if the battery voltage is found to be less than VBL. Similarly, if VBAT is
greater than VBL, the BL bit is cleared during battery check.
The BL bit retains its state until the next battery check occurs. This means the BL bit will not
clear immediately upon battery replacement, but only after the next battery check occurs at
the next power-up or midnight rollover.
If a battery low is generated during a power-up sequence, this indicates that the battery is
below approximately 2.5 volts and may not be able to maintain data integrity. Clock data
should be considered suspect and verified as correct. A fresh battery should be installed.
If a battery low indication is generated during the 24-hour interval check, this indicates that
the battery is near end of life. However, data is not compromised due to the fact that a
nominal VCC is supplied. In order to ensure data integrity during subsequent periods of
battery backup mode, the battery should be replaced.
Midnight rollover check
As shown in Figure 22, during the midnight rollover check, the M41T8x applies a load to the
battery, then compares VBAT to VBL and updates the BL bit accordingly. Because a load is
present, an open condition on the VBAT pin will result in the BL bit being set. After the check
is performed, the RTC removes the load.
Power-up battery check
During the power-up check, no load is applied to the battery under the assumption the
battery has already been stressed to its working level by having powered the RTC in backup
mode. If no battery is present, VBAT will be floating and the battery check result will be
indeterminate.
Figure 22. Battery check
At power-up
and at rollover
VBAT
Only at
rollover
VBL=2.5V
RL
S
Q
FF
BL
R
AM03009v1
Doc ID 12578 Rev 12
39/61
Clock operation
M41T82-M41T83
The M41T8x only checks the battery when powered by VCC. It does not check the battery
while in backup mode. Thus, users are advised that during long periods in backup mode,
the battery can drop to a level at which timekeeping may fail or data becomes corrupted. If,
at power-up, a battery low is indicated, data integrity should be verified.
Forcing a battery check
If it is desired to check the battery at an arbitrary time, one common technique is for the
application software to write the time to just before midnight, 23:59:59, and then wait two
seconds thereby letting the clock rollover and causing the BL bit to update. The application
then restores the time back to its previous value plus two seconds.
3.11
Century bits
These two bits will increment in a binary fashion at the turn of the century, and handle all
leap years correctly. See Table 14 for additional explanation.
Table 14.
Century bits examples
CB0
CB1
Leap Year?
Example(1)
0
0
Yes
2000
0
1
No
2100
1
0
No
2200
1
1
No
2300
1. Leap year occurs every four years (for years evenly divisible by four), except for years evenly divisible by
100. The only exceptions are those years evenly divisible by 400 (the year 2000 was a leap year, year
2100 is not).
3.12
Oscillator fail detection
If the oscillator fail (OF) bit is internally set to a '1,' this indicates that the oscillator has either
stopped, or was stopped for some period of time. This bit can be used to judge the validity of
the clock and date data. This bit will be set to '1' any time the oscillator stops.
In the event the OF bit is found to be set to '1' at any time other than the initial power-up, the
STOP bit (ST) should be written to a '1,' then immediately reset to 0. This will restart the
oscillator. The following conditions can cause the OF bit to be set:
●
Note:
The first time power is applied (defaults to a '1' on power-up).
If the OF bit cannot be written to '0' four seconds after the initial power-up, the STOP bit (ST)
should be written to a '1,' then immediately reset to 0.
●
The voltage present on VCC or battery is insufficient to support oscillation.
●
The ST bit is set to '1.'
●
External interference of the crystal
For the M41T83, if the oscillator fail interrupt enable bit (OFIE) is set to a '1,' the
IRQ1/FT/OUT pin will also be asserted (see Section 3.13 and Section 3.14 for additional
conditions which apply). The IRQ1/FT/OUT output is de-asserted by resetting the OF bit to
0, NOT by reading the flags register. The OF bit will remain a '1' until written to 0. Reading
the flags register has no effect on OF.
40/61
Doc ID 12578 Rev 12
M41T82-M41T83
Clock operation
The oscillator must start and have run for at least 4 seconds before attempting to reset the
OF bit to 0.
The oscillator fail detect circuit funtions during backup mode. If a triggering event occurs to
disrupt the oscillator during a power-down condition, the OF bit will be set accordingly.
3.13
Oscillator fail interrupt enable (M41T83 only)
With the OFIE bit set, the OF bit will cause the IRQ1/FT/OUT output to be asserted (see
Section 3.14.1 and 3.14.2 for additional conditions that apply). The IRQ1/FT/OUT output is
cleared by resetting the OF bit to 0 (NOT by reading the flags register). Clearing the OFIE bit
will also cause the IRQ1/FT/OUT output to de-assert, but if OFIE is subsequently set prior to
clearing OF, the IRQ1/FT/OUT output will assert immediately upon setting OFIE. Clearing
the OF bit is necessary to prevent such an inadvertent interrupt.
If the alarm in backup enable bit, ABE, is set (along with OFIE), the oscillator fail detect will
cause an interrupt in the IRQ1/FT/OUT pin during backup mode. For additional information
on this, refer to Section 3.14.2.
3.14
IRQ1/FT/OUT pin, frequency test, interrupts and the OUT bit
(M41T83 only)
Four interrupt sources, the frequency test function, and the discrete output bit OUT all share
the IRQ1/FT/OUT pin. Priority is built into the part such that some functions dominate
others. Additionally, the priority depends on configuration bits such as OUT and ABE, and
on whether the part is operating on VCC or is in the backup mode. This pin is an open drain
output and requires an external pull-up resistor.
Figure 23 shows the various signal sources and controlling bits for the IRQ1/FT/OUT output
pin.
Figure 23. IRQ1/FT/OUT output pin circuit
TIMER
TE
reload
TF
TI/TP
TIE
OUT
FT
ABE
Write OF to 0
to clear
Read FLAGS register
to clear
IRQ1/OUT/FT
LOGIC
IRQ1/OUT/FT
A1IE
OFIE
TIE
w-dog running
OF
OFIE
AF1
AI1E
WDF
Write watchdog register
to clear
PRE
Q
WDOG
Doc ID 12578 Rev 12
AM03013v1
41/61
Clock operation
M41T82-M41T83
The timer, oscillator fail detect circuit, alarm 1, and watchdog are ORed together as the
primary interrupt sources. The frequency test signal, FT, is used to enable a 512 Hz output
on the IRQ1/FT/OUT pin for calibrating the RTC. When not used as an interrupt or
frequency test output, the pin can be used as a discrete logic output controlled by the OUT
bit. The ABE bit is used to enable interrupts during backup mode.
Operating on VCC, all four interrupt sources are available. During backup, the timer and
watchdog are disabled, and the only interrupt sources are alarm 1 and the oscillator fail
detect circuit.
3.14.1
Active mode operation on VCC
On VCC, the operation of the output circuit is as shown in Table 15.
Table 15.
Priority for IRQ1/FT/OUT pin when operating on VCC
OUT(1)
FT(2)
A1IE(3)
+ OFIE(4)
+ TIE(5)
+ watchdog(6)
running
0
0
x
0
1
x
Pin
0
Comment
When OUT is 0 and FT is not enabled, OUT dominates
and none of the interrupt sources have any effect.
512 Hz
When FT = 1 and OUT = 1 and no interrupts are enabled,
the output will be the 512 Hz frequency test (FT) signal.
x
1
0
1
x
1
IRQ
When one or more interrupts are enabled, and OUT is a 1,
the pin stays high until one of the interrupts is asserted.
1
0
0
1
When OUT is 1, FT is 0 and no interrupts are enabled, the
pin is high.
1. OUT is bit 7 of register 08h (digital calibration).
2. FT is bit 6 of register 08h (digital calibration).
3. A1IE is bit 7 of register 0Ah (alarm 1, month).
4. OFIE is bit 7 of register 09h (watchdog).
5. TIE is bit 5 of register 11h (timer control).
6. The watchdog is controlled by register 09h (watchdog).
When OUT is 0 and FT is 0, the pin will be 0 regardless of whether any interrupts are
enabled.
When FT is a 1, the 512 Hz signal will be output if OUT is 0 or if no interrupts are enabled.
The interrupt sources control the pin when OUT is 1 and one or more of the interrupts are
enabled.
If OUT is 1, FT is 0 and no interrupts are enabled, then the pin will be 1.
42/61
Doc ID 12578 Rev 12
M41T82-M41T83
3.14.2
Clock operation
Backup mode
In backup mode, the operation of the output circuit is as shown in Table 16.
Table 16.
Priority for IRQ1/FT/OUT pin when operating in backup mode
OUT(1)
ABE(2)
A1IE(3)
+ OFIE(4)
Pin
Comment
x
0
x
1
When ABE is 0, the pin is 1 regardless of OUT or
the interrupt sources.
1
x
0
1
When OUT is 1 and no interrupts are enabled,
the pin is 1. (A1IE and OFIE are the only
interrupts applicable in this mode).
0
1
x
0
When ABE is 1 and OUT is 0, OUT dominates
and regardless of the interrupt sources.
1
1
1
IRQ
When one or more interrupts are enabled, ABE is
a 1, and OUT is a 1, the pin stays high until one of
the interrupts is asserted.
1. OUT is bit 7 of register 08h (digital calibration).
2. ABE is bit 5 of register 0Ah (alarm 1, month).
3. A1IE is bit 7 of register 0Ah (alarm 1, month).
4. OFIE is bit 7 of register 09h (watchdog).
In backup mode, frequency test is disabled. Thus, the FT bit is a ‘don’t care’.
ABE enables interrupts in backup. If it is 0, the output pin is a 1 regardless of the other bits.
The pin is also a 1 when OUT is a 1 and no interrupts are enabled.
When OUT is 0 and ABE is a 1, the pin is 0 regardless of the interrupts.
Thus, in order to enable interrupts in backup mode, OUT must be a 1 and ABE must be a 1,
and one or more of the interrupt enables must be a 1.
Simultaneous interrupts
Since more than one interrupt source can cause the IRQ1/FT/OUT pin to go low, more than
one interrupt may be pending when the microprocessor services the interrupt. Therefore,
the application software should read the flags register (0Fh) to discern which condition or
conditions are causing the pin to be asserted.
Also be aware that once a flag causes the pin to assert, other flags could subsequently also
go true. Since the pin is already low due to the first, no additional output transition will occur.
That is why the software must check the flags register.
Example: If the watchdog is in use and the oscillator fail detect interrupt is enabled, and the
watchdog times out, the IRQ1/FT/OUT pin will go low. If, in the intervening time before the
processor services the interrupt, something disturbs the oscillator, such as a drop of
moisture landing on the crystal pins, the OF bit will also be set. Thus, when the software
services the interrupt, it must service both sources: it must re-initialize the watchdog and
clear the OF bit in order to de-assert the IRQ1/FT/OUT pin. By reading the flags register, the
software will know both flags were set and that both need service.
Doc ID 12578 Rev 12
43/61
Clock operation
3.15
M41T82-M41T83
FT/RST pin, frequency test and reset output pin (M41T82
only)
On the M41T82, the 512 Hz frequency test signal and the reset output share the same pin,
FT/RST. When the FT bit (bit 6 of register 08h) is a 1, the 512 Hz test signal is activated on
the pin. With FT a 0 and VCC good (above VRST), the output will be high. If the 512 Hz is
enabled when VCC fails, the FT bit will be cleared and the output will go low to assert reset.
At power-up, FT will be 0 leaving the pin functioning as the reset output.
3.16
Initial power-on defaults
Upon initial application of power to the device, the register bits will initially power-on in the
state indicated in Table 17 and Table 18.
Table 17.
Initial power-on default values (part 1)
Condition(1)
ST CB1 CB0 OUT FT
Initial
power-up
0
Subsequent
UC
power-up(4)(5)
WatchDCS Digital Analog
OFIE(2)
A1IE (2) SQWE(2) ABE
dog(3)
ACS calib. calib.
0
0
1
0
0
0
0
0
0
0
1
0
UC
UC
UC
0
UC
UC
UC
UC
0
UC
UC
UC
1. All other control bits power-up in an undetermined state.
2. M41T83 only
3. BMB0-BMB4, RB0, RB1
4. With battery backup
5. UC = unchanged
Table 18.
Initial power-up default values (part 2)
Condition(1)
RPT11
HT OF TE
-15
Initial
power-up
Subsequent
power-up(3)(4)
TI/TP
(2)
TIE(2) TD1 TD0 RS0 RS1-3
(2)
A2IE(2)
RPT21AL2E
25
0
1
1
0
0
0
1
1
1
0
0
0
0
0
UC
1
UC
0
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
1. All other control bits power-up in an undetermined state.
2. M41T83 only
3. With battery backup
4. UC = unchanged
44/61
OTP
Doc ID 12578 Rev 12
M41T82-M41T83
3.17
Clock operation
OTP bit operation (M41T83 in SOX18 package only)
When the OTP (one time programmable) bit is set to a '1,' the value in the internal OTP
registers will be transferred to the analog calibration register (12h) and are “Read only.” The
OTP value is programmed by the manufacturer, and will contain the calibration value
necessary to achieve ±5 ppm at room temperature after two SMT reflows. This clock
accuracy can then be guaranteed to drift no more than ±3 ppm the first year, and ±1 ppm for
each following year due to crystal aging.
If the OTP bit is set to 0, the analog calibration register will become a WRITE/READ register
and function like standard SRAM memory cells, allowing the user to implement any desired
value of analog calibration.
When the user sets the OTP bit, they need to wait for approximately 8 ms before the analog
registers transfer the value from the OTP to the analog registers due to the OTP read
operation.
Doc ID 12578 Rev 12
45/61
Maximum ratings
4
M41T82-M41T83
Maximum ratings
Stressing the device above the rating listed in the absolute maximum ratings table may
cause permanent damage to the device. These are stress ratings only and operation of the
device at these or any other conditions above those indicated in the operating sections of
this specification is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect device reliability. Refer also to the STMicroelectronics SURE
Program and other relevant quality documents.
Table 19.
Absolute maximum ratings
Sym
Parameter
Value(1)
Unit
TSTG
Storage temperature (VCC off, oscillator off)
–55 to 125
°C
VCC
Supply voltage
–0.3 to 7.0
V
QFN16
TSLD
Lead solder temperature for 10 seconds
SOX18
VIO
260(2)
SO8
Input or output voltages
°C
240(3)
–0.2 to VCC+0.3
V
IO
Output current
20
mA
PD
Power dissipation
1
W
θJA
Thermal resistance, junction to ambient
QFN16
35.7
SO8
128.4
SOX18
1. Data based on characterization results, not tested in production.
2. Reflow at peak temperature of 260 °C. The time above 255 °C must not exceed 30 seconds.
3. Reflow at peak temperature of 240 °C. The time above 235 °C must not exceed 20 seconds.
46/61
Doc ID 12578 Rev 12
°C/W
M41T82-M41T83
5
DC and AC parameters
DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the dc and
ac characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Table 20.
Operating and AC measurement conditions
Parameter(1)
M41T8x
Supply voltage (VCC)
2.38 V to 5.5 V
Ambient operating temperature (TA)
–40 to 85 °C
Load capacitance (CL)
50 pF
Input rise and fall times
≤ 5 ns
Input pulse voltages
0.2 VCC to 0.8 VCC
Input and output timing ref. voltages
0.3 VCC to 0.7 VCC
1. Output Hi-Z is defined as the point where data is no longer driven.
Figure 24. Measurement AC I/O waveform
0.8VCC
0.7VCC
0.3VCC
0.2VCC
Table 21.
AI02568
Capacitance
Parameter(1)(2)
Symbol
CIN
COUT(3)
tLP
Min
Max
Unit
Input capacitance
7
pF
Output capacitance
10
pF
Low-pass filter input time constant (SDA and SCL)
50
ns
1. Effective capacitance measured with power supply at 3.6 V; sampled only, not 100% tested.
2. At 25 °C, f = 1 MHz
3. Outputs deselected
Doc ID 12578 Rev 12
47/61
DC and AC parameters
Table 22.
Sym
M41T82-M41T83
DC characteristics
Test condition(1)
Min
Operating voltage (S)
–40 to 85 °C
Operating voltage (R)
Max
Unit
3.00
5.50
V
–40 to 85 °C
2.70
5.50
V
Operating voltage (Z)
–40 to 85 °C
2.38
5.50
V
ILI
Input leakage current
0V ≤ VIN ≤ VCC
±1
µA
ILO
Output leakage current
0V ≤ VOUT ≤ VCC
±1
µA
150
µA
VCC
ICC1
Parameter
Supply current
Typ
5.5 V
125
3.0 V
55
µA
2.5 (Z only)
45
µA
5.5 V
8
3.0 V
6.5
SCL = 400 kHz
(No load)
ICC2
SCL = 0 Hz;
All
inputs
≥ VCC – 0.2 V or
Supply current (standby)
≤ VSS + 0.2 V
(SQWE bit = 0)
VIL
Input low voltage
–0.3
0.3VCC
V
VIH
Input high voltage
0.7VCC
VCC+0.3
V
VOL
VOH
Output low voltage
Output high voltage
Pull-up supply voltage
(open drain)
VBAT
Backup supply voltage
(battery or capacitor)
VBL
Battery low (BL bit)
threshold
IBAT
Battery supply current
µA
µA
RST, FT/RST
VCC/VBAT = 3.0 V,
IOL = 1.0 mA
0.4
V
SQW, IRQ1/FT/OUT, IRQ2
VCC = 3.0 V,
IOL = 1.0 mA
0.4
V
SCL, SDA
VCC = 3.0 V,
IOL = 3.0 mA
0.4
V
VCC = 3.0 V, IOH = –1.0 mA (push-pull)
2.4
V
IRQ1/FT/OUT, IRQ2, FT/RST, RST
2.0
5.5
V
5.5
V
2.5
25 °C; VCC = 0 V; OSC on;
VBAT = 3 V; 32 KHz off
365
1. Valid for ambient operating temperature: TA = –40 to 85 °C; VCC = 2.38 V to 5.5 V (except where noted)
48/61
10
Doc ID 12578 Rev 12
V
450
nA
M41T82-M41T83
DC and AC parameters
Figure 25. ICC2 vs. temperature
10.000
9.000
8.000
Icc2 (µA)
7.000
(3.0V)
(5.0V)
6.000
5.000
4.000
3.000
2.000
-40
-20
0
20
40
60
80
Temperature (°C)
ai 13909
Table 23.
Crystal electrical characteristics
Parameter(1)(2)
Symbol
fO
Min
Resonant frequency
RS
Series resistance
CL
Load capacitance
Typ
Max
32.768
Units
kHz
65(3)
12.5
kΩ
pF
1. Externally supplied if using the QFN16 or SO8 package. STMicroelectronics recommends the Citizen CFS145 (1.5 x 5 mm) and the KDS DT-38 (3 x 8 mm) for thru-hole, or the KDS DMX-26S (3.2 x 8 mm) or Micro
Crystal MS3V-T1R (1.5 x 5 mm) for surface-mount, tuning fork-type quartz crystals. For contact
information, see Section 8: References on page 59.
2. Load capacitors are integrated within the M41T8x. Circuit board layout considerations for the 32.768 kHz
crystal of minimum trace lengths and isolation from RF generating signals should be taken into account.
3. Guaranteed by design.
Table 24.
Oscillator characteristics
Parameter(1)(2)
Symbol
VSTA
Oscillator start voltage
tSTA
Oscillator start time
CXI, CXO(1)
Conditions
Min
≤ 4s
2.0
IC-to-IC frequency
Max
1
25
–10
Units
V
VCC = VSO
Capacitor input, capacitor output
variation(2)(3)
Typ
s
pF
+10
ppm
1. With default analog calibration value ( = 0)
2. Reference value
3. TA = 25 °C, VCC = 5.0 V
Doc ID 12578 Rev 12
49/61
DC and AC parameters
M41T82-M41T83
Figure 26. Power down/up mode AC waveforms
VCC
VSO
VRST
trec
SDA, SCL
DON'T CARE
tRD
RST
AI00596
Table 25.
Power down/up trip points DC characteristics
Parameter(1)(2)
Sym
VRST
Reset threshold voltage
Min
Typ
Max
Unit
S
2.85
2.93
3.0
V
R
2.55
2.63
2.7
V
Z
2.25
2.32
2.38
V
Battery backup switchover
VSO
Hysteresis
trec
RST duration after VCC high
tRD
VCC to reset delay(3)
VRST
V
25
mV
140
280
2.5
ms
µs
1. All voltages referenced to VSS
2. Valid for ambient operating temperature: TA = –40 to 85 °C; VCC = 2.38 to 5.5 V (except where noted)
3. Measured with VCC falling slew rate of 10 mV/µs for VCC in the range VRST + 100 mV to VRST – 100 mV
50/61
Doc ID 12578 Rev 12
M41T82-M41T83
DC and AC parameters
Figure 27. Bus timing requirement sequence
SDA
tBUF
tHD:STA
tHD:STA
tR
tF
SCL
tHIGH
P
S
tLOW
tSU:DAT
tHD:DAT
tSU:STA
SR
tSU:STO
P
AI00589
Table 26.
AC characteristics
Parameter(1)
Sym
Min
Typ
Max
Units
400
kHz
fSCL
SCL clock frequency
tLOW
Clock low period
1.3
µs
tHIGH
Clock high period
600
ns
0
tR
SDA and SCL rise time
300
ns
tF
SDA and SCL fall time
300
ns
tHD:STA
START condition hold time
(after this period the first clock pulse is generated)
600
ns
tSU:STA
START condition setup time
(only relevant for a repeated start condition)
600
ns
100
ns
0
µs
tSU:DAT(2) Data setup time
tHD:DAT
Data hold time
tSU:STO
STOP condition setup time
600
ns
Time the bus must be free before a new transmission
can start
1.3
µs
tBUF
1. Valid for ambient operating temperature: TA = –40 to 85 °C; VCC = 2.38 to 5.5 V (except where noted).
2. Transmitter must internally provide a hold time to bridge the undefined region (300 ns max) of the falling
edge of SCL.
Doc ID 12578 Rev 12
51/61
Package mechanical data
6
M41T82-M41T83
Package mechanical data
In order to meet environmental requirements, ST offers these devices in different grades of
ECOPACK® packages, depending on their level of environmental compliance. ECOPACK®
specifications, grade definitions and product status are available at: www.st.com.
ECOPACK® is an ST trademark.
52/61
Doc ID 12578 Rev 12
M41T82-M41T83
Package mechanical data
Figure 28. QFN16 – 16-lead, quad, flat package, no lead, 4 x 4 mm body size outline
D
E
A3
A1
A
ddd C
e
b
L
1
2
E2
3
D2
QFN16-A
Note:
Drawing is not to scale.
Table 27.
QFN16 – 16-lead, quad, flat package, no lead, 4 x 4 mm pack. mech. data
mm
inches
Sym
Typ
Min
Max
Typ
Min
Max
A
0.90
0.80
1.00
0.035
0.031
0.039
A1
0.02
0.00
0.05
0.001
0.000
0.002
A3
0.20
–
–
0.008
–
–
b
0.30
0.25
0.35
0.012
0.010
0.014
D
4.00
3.90
4.10
0.157
0.154
0.161
D2
–
2.50
2.80
–
0.098
0.110
E
4.00
3.90
4.10
0.157
0.154
0.161
E2
–
2.50
2.80
–
0.098
0.110
e
0.65
–
–
0.026
–
–
L
0.40
0.30
0.50
0.016
0.012
0.020
ddd
–
0.08
–
–
0.003
–
Doc ID 12578 Rev 12
53/61
Package mechanical data
M41T82-M41T83
Figure 29. QFN16 – 16-lead, quad, flat package, no lead, 4 x 4 mm, recommended
footprint
2.70
0.70
0.20
4.50
2.70
0.35
0.325
0.65
Note:
AI11815
Dimensions are shown in millimeters (mm).
Figure 30. 32 KHz crystal + QFN16 vs. VSOJ20 mechanical data
6.0 ± 0.2
3.2
VSOJ20
SMT
CRYSTAL
1.5
7.0 ± 0.3
13
14
16 XO
3.9
15 XI
1
2
3
ST QFN16
4
3.9
AI11816
Note:
54/61
Dimensions shown are in millimeters (mm).
Doc ID 12578 Rev 12
M41T82-M41T83
Package mechanical data
Figure 31. SOX18 – 18-lead plastic small outline, 300 mils, embedded crystal, outline
SOX18
Note:
Drawing is not to scale.
Table 28.
SOX18 – 18-lead plastic small outline, 300 mils, embedded crystal,
package mech. data
millimeters
inches
Symbol
Typ
Min
Max
Typ
Min
Max
A
2.57
2.44
2.69
0.101
0.096
0.106
A1
0.23
0.15
0.31
0.009
0.006
0.012
A2
2.34
2.29
2.39
0.092
0.090
0.094
B
0.46
0.41
0.51
0.018
0.016
0.020
c
0.25
0.20
0.31
0.010
0.008
0.012
D
11.61
11.56
11.66
0.457
0.455
0.459
E
7.62
7.57
7.67
0.300
0.298
0.302
E1
10.34
10.16
10.52
0.407
0.400
0.414
e
1.27
–
–
0.050
–
–
L
0.66
0.51
0.81
0.026
0.020
0.032
Doc ID 12578 Rev 12
55/61
Package mechanical data
M41T82-M41T83
Figure 32. SO8 – 8-lead plastic small package outline
h x 45°
A2
A
c
ccc
b
e
0.25 mm
GAUGE PLANE
D
k
8
E1
E
1
A1
L
L1
SO-A
Note:
Drawing is not to scale.
Table 29.
SO8 – 8-lead plastic small outline (150 mils body width), package mech.
data
mm
inches
Symb
Typ
Min
A
Typ
Min
1.75
Max
0.069
A1
0.10
A2
1.25
b
0.28
0.48
0.011
0.019
c
0.17
0.23
0.007
0.009
ccc
0.25
0.004
0.010
0.049
0.10
0.004
D
4.90
4.80
5.00
0.193
0.189
0.197
E
6.00
5.80
6.20
0.236
0.228
0.244
E1
3.90
3.80
4.00
0.154
0.150
0.157
e
1.27
-
-
0.050
-
-
h
0.25
0.50
0.010
0.020
k
0°
8°
0°
8°
L
0.40
0.127
0.016
0.050
L1
56/61
Max
1.04
0.041
Doc ID 12578 Rev 12
M41T82-M41T83
Package mechanical data
Figure 33. Carrier tape for QFN16, SOX18, and SO8 packages
P0
E
P2
D
T
A0
F
TOP COVER
TAPE
W
B0
P1
CENTER LINES
OF CAVITY
K0
USER DIRECTION OF FEED
AM03073v1
Table 30.
Carrier tape dimensions for QFN16, SOX18, and SO8 packages
Package
W
D
QFN16
12.00
±0.30
1.50
+0.10/
–0.00
SOX18
24.00
±0.30
SO8
12.00
±0.30
E
P0
P2
F
B0
K0
P1
T
1.75
4.00
2.00
5.50
±0.10 ±0.10 ±0.10 ±0.05
4.30
±0.10
4.30
±0.10
1.10
±0.10
8.00
±0.10
0.30
±0.05
mm 1000
1.50
+0.10/
–0.00
1.75
4.00
2.00 11.50
±0.10 ±0.10 ±0.10 ±0.10
12.70
±0.10
11.90
±0.10
3.20
±0.10
16.00
±0.10
0.30
±0.05
mm 1000
1.50
+0.10/
–0.00
1.75
4.00
2.00
5.50
±0.10 ±0.10 ±0.10 ±0.05
6.50
±0.10
5.30
±0.10
2.20
±0.10
8.00
±0.10
0.30
±0.05
mm 2500
Doc ID 12578 Rev 12
Unit
Bulk
Qty
A0
57/61
Part numbering
7
M41T82-M41T83
Part numbering
Table 31.
Ordering information
Example:
M41T
83
S
QA
6
E
Device family
M41T
Device type
82 (SO8 package only)
83
Operating voltage
S = VCC = 3.00 to 5.5 V
R = VCC = 2.70 to 5.5 V
Z = VCC = 2.38 to 5.5 V
Package
QA = QFN16 (4 mm x 4 mm)
M(1) = SO8
MY(2)= SOX18
Temperature range
6 = –40 °C to 85 °C
Shipping method
E = ECOPACK® package, tubes
F = ECOPACK® package, tape & reel
1. M41T82 only
2. The SOX18 package includes an embedded 32,768 Hz crystal.
For other options, or for more information on any aspect of this device, please contact the
ST sales office nearest you.
58/61
Doc ID 12578 Rev 12
M41T82-M41T83
8
References
References
Below is a listing of the crystal component suppliers mentioned in this document.
●
KDS can be contacted at [email protected] or http://www.kdsj.co.jp.
●
Citizen can be contacted at [email protected] or
http://www.citizencrystal.com.
●
Micro Crystal can be contacted at [email protected] or
http://www.microcrystal.com.
Doc ID 12578 Rev 12
59/61
Revision history
M41T82-M41T83
9
Revision history
Table 32.
Document revision history
Date
Revision
Changes
09-Apr-2009
9
Updated Table 1, 2, 4, 6, 10, 11, 22, Figure 19, 26, Section 3, Section 3.4.1,
Section 3.4.2, Section 3.5, Section 3.6, Section 3.7, Section 3.8,
Section 3.8.2, Section 3.8.3, Section 3.8.4, Section 3.8.5, Section 3.12,
Section 3.13, Section 6; added Section 3.8.1, Section 3.14, Section 3.15,
Table 9, 15, 16, Figure 21, 23; removed “output driver pin” section, “alarm
interrupt reset waveform” figure, “backup mode alarm waveform” figure, “timer
countdown value register bits (addr 11h)” table; added tape and reel
information Figure 33, Table 30.
05-Jan-2010
10
Updated Section 2.2: Read mode, Section 2.3: Write mode, Section 3: Clock
operation, Section 3.1: Power-down time-stamp, Section 3.2: Clock/control
register map and divider chain, Table 26.
25-Mar-2010
11
Updated Figure 26; Table 25.
19-Oct-2010
12
Updated Note in Section 3.12: Oscillator fail detection.
60/61
Doc ID 12578 Rev 12
M41T82-M41T83
Please Read Carefully:
Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the
right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any
time, without notice.
All ST products are sold pursuant to ST’s terms and conditions of sale.
Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no
liability whatsoever relating to the choice, selection or use of the ST products and services described herein.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this
document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products
or services, or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoever of such
third party products or services or any intellectual property contained therein.
UNLESS OTHERWISE SET FORTH IN ST’S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED
WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED
WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS
OF ANY JURISDICTION), OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
UNLESS EXPRESSLY APPROVED IN WRITING BY AN AUTHORIZED ST REPRESENTATIVE, ST PRODUCTS ARE NOT
RECOMMENDED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING
APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJURY,
DEATH, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. ST PRODUCTS WHICH ARE NOT SPECIFIED AS "AUTOMOTIVE
GRADE" MAY ONLY BE USED IN AUTOMOTIVE APPLICATIONS AT USER’S OWN RISK.
Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void
any warranty granted by ST for the ST product or service described herein and shall not create or extend in any manner whatsoever, any
liability of ST.
ST and the ST logo are trademarks or registered trademarks of ST in various countries.
Information in this document supersedes and replaces all information previously supplied.
The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners.
© 2010 STMicroelectronics - All rights reserved
STMicroelectronics group of companies
Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Philippines - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America
www.st.com
Doc ID 12578 Rev 12
61/61
Similar pages