AIMTEC AM2GH-2412SZ 2 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM2GH-Z
2 Watt | DC-DC Converter
FEATURES:




SIP8 Package
Low Ripple and Noise
Continuous Short Circuit Protection
-40ºC to +85ºC Operating Temperature Range




Ultra-Wide Input Range 4:1
1600 VDC I/O Isolation
Efficiency up to 79%
Remote ON/OFF Control
Models
Single output
Model
Input
Voltage (V)
Output
Voltage
(V)
Output Current
Max (mA)
Maximum
Capacitive
Load (µF)
4.5-18
4.5-18
4.5-18
4.5-18
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
500
400
166
133
500
400
166
133
500
400
166
133
1000
1000
220
100
1000
1000
220
100
1000
1000
220
100
Input
Voltage (V)
Output
Voltage
(V)
Output Current
Max (mA)
Maximum
Capacitive
Load (µF)
AM2GH-1203SZ
AM2GH-1205SZ
AM2GH-1212SZ
AM2GH-1215SZ
AM2GH-2403SZ
AM2GH-2405SZ
AM2GH-2412SZ
AM2GH-2415SZ
AM2GH-4803SZ
AM2GH-4805SZ
AM2GH-4812SZ
AM2GH-4815SZ
Input Current
Full Load | No
Load (mA)
196
225
213
213
96
106
105
105
47
55
55
54
40
40
40
40
25
20
30
30
10
15
15
15
Efficiency
(%)
70
74
78
78
71
78
79
79
72
75
75
76
Models
Dual output
Model
Input Current
Full Load | No
Load (mA)
Efficiency
(%)
AM2GH-1205DZ
4.5-18
±5
±200
±470
219
30
77
AM2GH-1212DZ
4.5-18
±12
±83
±100
213
30
78
AM2GH-1215DZ
4.5-18
±15
±66
±47
216
40
77
AM2GH-2405DZ
9-36
±5
±200
±470
111
30
75
AM2GH-2412DZ
9-36
±12
±83
±100
108
30
77
AM2GH-2415DZ
9-36
±15
±66
±47
106
30
78
AM2GH-4805DZ
18-75
±5
±200
±470
56
15
74
AM2GH-4812DZ
18-75
±12
±83
±100
56
15
74
AM2GH-4815DZ
18-75
±15
±66
±47
55
15
75
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
12
24
48
Filter
Start up time
Absolute Maximum Rating
Peak Input Voltage time
On/Off control
No Load Input Current
Input reflected current
www.aimtec.com
F 051e R12.D
12
24
48
Typical
4.5-18
9-36
18-75
Capacitor
30
Maximum
Units
VDC
ms
25
50
VDC
100
100
ms
ON: 0 to 0.6VDC (or open) ; OFF:2.7 to 15.0VDC, OFF idle current: 2-4mA
40
mA
20
mA
Tel: +1 514 620 2722
1 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2GH-Z
2 Watt | DC-DC Converter
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Resistance
Capacitance
Typical
60 sec
Rated
Units
1600
VDC
MOhm
pF
>1000
200
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
Cross Regulation (Dual Output Models)
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
25% load on one output - 100% load
on second load
Maximum
%
±5
%
Continuous
Auto-Recovery
±0.2
±1
±0.02
30
From 0% to 100% load
20MHz Bandwidth
Units
±1
%
%
%/oC
mV p-p
General Specifications
Parameters
Conditions
Typical
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Potting Material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
100% load
100
Maximum
-40 to 85
-40 to +125
100
Above 71°C
5
Free Air Convection
95
Non conductive black plastic
Silicon (UL94V-0 rated)
4.8
0.86 x 0.36 x 0.44 inches
21.85 x 9.20 x 11.10 mm
>1,700,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC)hours
1.5mm from case for 10 second
260
250
±3
Units
KHz
oC
oC
oC
%/ oC
% RH
g
oC
uS
%
Safety Specifications
Parameter
Agency Approvals
Standards
www.aimtec.com
F 051e R12.D
CE
EN55022: 2006 + A1:2007, Class A
EN55024:1998 + A1:2001 + A2:2003
IEC61000-4-2:1995 + A1:1998 + A2:2000, Perf. Criteria B
IEC61000-4-3:2006, Perf. Criteria A
IEC61000-4-4:2004, Perf. Criteria B (external 220uF/100V cap required)
IEC61000-4-5:2005, Perf. Criteria B (external 220uF/100V cap required)
IEC61000-4-6:2007, Perf. Criteria A
IEC61000-4-8, Perf:1993 + A1:2000, Criteria A
NOTE: Also designed to meet IEC 60950-1:2001
Tel: +1 514 620 2722
2 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2GH-Z
2 Watt | DC-DC Converter
Pin Out Specifications
Pin
Single
Dual
1
2
3
5
6
7
8
- V Input
+ V Input
On/Off Control
N.C.
+ V Output
- V Output
N.C.
- V Input
+ V Input
On/Off Control
N.C.
+ V Output
Common
- V Output
NC: Not Connected
Dimensions
21.85
(0.85)
9.20
(0.36)
PRINTED
FACE
10.60
(0.42)
11.10
(0.44)
0.50
(0.02)
3.05
(0.12)
2.54
(0.10)
17.78
(0.70)
0.50
(0.02)
1
2
5
3
6
7
8
9.20
(0.38)
0.25
(0.01)
0.50
(0.02)
3.50
(0.14)
Derating
Free Air Convection
71º C
Output Power (%)
100
80
Safe Operating Area
60
40
30
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
3 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2GH-Z
2 Watt | DC-DC Converter
Control ON/OFF pin connection example
VCC (VDC)
R1 (KΩ)
R2(KΩ)
ZD1(V , mA)
4.5 -18
9 - 36
18 - 75
7.5
18
33
0
2.2
6.8
10, 5
18, 5
36, 5
Recommended Circuits
Conducted and Radiated Emissions
Input Voltage (V)
12
24
48
C1 (uF/V)
10/35
2.2/35
2.2/35
L(uH)
2.5
10
18
EFT / Surge
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
4 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2GH-Z
2 Watt | DC-DC Converter
Typical Efficiency Example Charts
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
5 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2GH-Z
2 Watt | DC-DC Converter
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
6 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages