FUJITSU SEMICONDUCTOR DATA SHEET DS05-20851-4E FLASH MEMORY CMOS 4M (512K × 8/256K × 16) BIT MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ FEATURES • Single 5.0 V read, write, and erase Minimizes system level power requirements • Compatible with JEDEC-standard commands Uses same software commands as E2PROMs • Compatible with JEDEC-standard world-wide pinouts 48-pin TSOP (Package suffix: PFTN – Normal Bend Type, PFTR – Reversed Bend Type) 44-pin SOP (Package suffix: PF) • Minimum 100,000 write/erase cycles • High performance 55 ns maximum access time • Sector erase architecture One 16K byte, two 8K bytes, one 32K byte, and seven 64K bytes. Any combination of sectors can be concurrently erased. Also supports full chip erase. • Boot Code Sector Architecture T = Top sector B = Bottom sector • Embedded EraseTM Algorithms Automatically pre-programs and erases the chip or any sector • Embedded ProgramTM Algorithms Automatically writes and verifies data at specified address • Data Polling and Toggle Bit feature for detection of program or erase cycle completion • Ready/Busy output (RY/BY) Hardware method for detection of program or erase cycle completion • Low Vcc write inhibit ≤ 3.2 V • Erase Suspend/Resume Suspends the erase operation to allow a read in another sector within the same device • Hardware RESET pin Resets internal state machine to the read mode • Sector protection Hardware method disables any combination of sectors from write or erase operations • Temporary sector unprotection Temporary sector unprotection via the RESET pin. Embedded EraseTM and Embedded ProgramTM are trademarks of Advanced Micro Devices, Inc. MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ PACKAGE 48-pin TSOP (I) 44-pin SOP Marking Side Marking Side Marking Side (FPT-48P-M19) 2 (FPT-48P-M20) (FPT-44P-M16) MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ GENERAL DESCRIPTION The MBM29F400TC/BC is a 4M-bit, 5.0 V-only Flash memory organized as 512K bytes of 8 bits each or 256K words of 16 bits each. The MBM29F400TC/BC is offered in a 48-pin TSOP and 44-pin SOP packages. This device is designed to be programmed in-system with the standard system 5.0 V VCC supply. 12.0 V VPP is not required for write or erase operations. The devices can also be reprogrammed in standard EPROM programmers. The standard MBM29F400TC/BC offers access times 55 ns and 90 ns allowing operation of high-speed microprocessors without wait states. To eliminate bus contention the device has separate chip enable (CE), write enable (WE), and output enable (OE) controls. The MBM29F400TC/BC is pin and command set compatible with JEDEC standard. Commands are written to the command register using standard microprocessor write timings. Register contents serve as input to an internal state-machine which controls the erase and programming circuitry. Write cycles also internally latch addresses and data needed for the programming and erase operations. Reading data out of the devices is similar to reading from12.0 V Flash or EPROM devices. The MBM29F400TC/BC is programmed by executing the program command sequence. This will invoke the Embedded Program Algorithm which is an internal algorithm that automatically times the program pulse widths and verifies proper cell margin. Typically, each sector can be programmed and verified in less than 0.5 seconds. Erase is accomplished by executing the erase command sequence. This will invoke the Embedded Erase Algorithm which is an internal algorithm that automatically preprograms the array if it is not already programmed before executing the erase operation. During erase, the device automatically times the erase pulse widths and verifies proper cell margin. A sector is typically erased and verified in 1.0 second (if already completely preprogrammed.). The devices also features a sector erase architecture. The sector mode allows each sector to be erased and reprogrammed without affecting other sectors. The MBM29F400TC/BC is erased when shipped from the factory. The devices features single 5.0 V power supply operation for both read and write functions. Internally generated and regulated voltages are provided for the program and erase operations. A low VCC detector automatically inhibits write operations on the loss of power. The end of program or erase is detected by Data Polling of DQ7, by the Toggle Bit feature on DQ6, or the RY/BY output pin. Once the end of a program or erase cycle has been completed, the device internally resets to the read mode. Fujitsu’s Flash technology combines years of EPROM and E2PROM experience to produce the highest levels of quality, reliability, and cost effectiveness. The MBM29F400TC/BC memory electrically erase the entire chip or all bits within a sector simultaneously via Fowler-Nordhiem tunneling. The bytes/words are programmed one byte/word at a time using the EPROM programming mechanism of hot electron injection. 3 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ FLEXIBLE SECTOR-ERASE ARCHITECTURE • One 16K byte, two 8K bytes, one 32K byte, and seven 64K bytes. • Individual-sector, multiple-sector, or bulk-erase capability. • Individual or multiple-sector protection is user definable. (×8) (×16) 7FFFFH 3FFFFH 7BFFFH 3DFFFH 64K byte 16K byte 6FFFFH 37FFFH 64K byte 8K byte 79FFFH 5FFFFH 2FFFFH 3CFFFH 64K byte 8K byte 77FFFH 4FFFFH 27FFFH 3BFFFH 64K byte 32K byte 6FFFFH 3FFFFH 1FFFFH 37FFFH 64K byte 64K byte 5FFFFH 2FFFFH 17FFFH 2FFFFH 64K byte 64K byte 4FFFFH 1FFFFH 0FFFFH 27FFFH 64K byte 64K byte 3FFFFH 0FFFFH 07FFFH 1FFFFH 32K byte 64K byte 2FFFFH 17FFFH 07FFFH 03FFFH 05FFFH 02FFFH 03FFFH 01FFFH 00000H 00000H 8K byte 64K byte 1FFFFH 0FFFFH 8K byte 64K byte 0FFFFH 07FFFH 16K byte 64K byte 00000H MBM29F400TC Sector Architecture 4 (×8) (×16) 7FFFFH 3FFFFH 00000H MBM29F400BC Sector Architecture MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ PRODUCT LINE UP Part No. MBM29F400TC/MBM29F400BC VCC = 5.0 V ± 5 % -55 — — VCC = 5.0 V ± 10 % — -70 -90 Max. Address Access Time (ns) 55 70 90 Max. CE Access Time (ns) 55 70 90 Max. OE Access Time (ns) 30 30 35 Ordering Part No. ■ BLOCK DIAGRAM RY/BY Buffer DQ0 to DQ15 RY/BY VCC VSS WE BYTE RESET Input/Output Buffers Erase Voltage Generator State Control Command Register Program Voltage Generator Chip Enable Output Enable Logic CE OE STB Low VCC Detector Timer for Program/Erase Address Latch STB Data Latch Y-Decoder Y-Gating X-Decoder Cell Matrix A0 to A17 A-1 5 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ CONNECTION DIAGRAMS SOP (Top View) TSOP (I) A15 A14 A13 A12 A11 A10 A9 A8 N.C. N.C. WE RESET N.C. N.C. RY/BY N.C. A17 A7 A6 A5 A4 A3 A2 A1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 (Marking Side) MBM29F400TC/MBM29F400BC Standard Pinout 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 A16 BYTE VSS DQ15/A-1 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VCC DQ11 DQ3 DQ10 DQ2 DQ9 DQ1 DQ8 DQ0 OE VSS CE A0 FPT-48P-M19 A1 A2 A3 A4 A5 A6 A7 A17 N.C. RY/BY N.C. N.C. RESET WE N.C. N.C. A8 A9 A10 A11 A12 A13 A14 A15 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 (Marking Side) MBM29F400TC/MBM29F400BC Reverse Pinout FPT-48P-M20 6 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 A0 CE VSS OE DQ0 DQ8 DQ1 DQ9 DQ2 DQ10 DQ3 DQ11 VCC DQ4 DQ12 DQ5 DQ13 DQ6 DQ14 DQ7 DQ15/A-1 VSS BYTE A16 N.C. 1 44 RESET RY/BY 2 43 WE A17 3 42 A8 A7 4 41 A9 A6 5 40 A10 A5 6 39 A11 A4 7 38 A12 A3 8 37 A13 A2 9 36 A14 A1 10 35 A15 A0 11 34 A16 CE 12 33 BYTE VSS 13 32 VSS OE 14 31 DQ15/A-1 DQ0 15 30 DQ7 DQ8 16 29 DQ14 DQ1 17 28 DQ6 DQ9 18 27 DQ13 DQ2 19 26 DQ5 DQ10 20 25 DQ12 DQ3 21 24 DQ4 DQ11 22 23 VCC FPT-44P-M16 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ LOGIC SYMBOL Table 1 MBM29F400TC/BC Pin Configuration Pin A-1 18 A0 to A17 CE OE RESET A-1, A0 to A17 Address Inputs DQ0 to DQ15 Data Inputs/Outputs 16 or 8 DQ0 to DQ15 WE Function CE Chip Enable OE Output Enable WE Write Enable RY/BY RY/BY Ready-Busy Output RESET Hardware Reset Pin/ Temporary Sector Unprotection BYTE BYTE Selects 8-bit or 16-bit mode N.C. No Internal Connection VSS Device Ground VCC Device Power Supply 7 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 Table 2 MBM29F400TC/BC User Bus Operation (BYTE = VIH) CE OE WE A0 A1 A6 A9 DQ0 to DQ15 RESET Auto-Select Manufacturer Code (1) L L H L L L VID Code H Auto-Select Device Code (1) L L H H L L VID Code H Read (3) L L H A0 A1 A6 A9 DOUT H Standby H X X X X X X HIGH-Z H Output Disable L H H X X X X HIGH-Z H Write L H L A0 A1 A6 A9 DIN H Enable Sector Protection (2) L VID X X L VID X H Verify Sector Protection (2) L L H L H L VID Code H Temporary Sector Unprotection X X X X X X X X VID Reset (Hardware)/Standby X X X X X X X HIGH-Z L Operation Table 3 MBM29F400TC/BC User Bus Operation (BYTE = VIL) 15 WE DQ /A-1 CE OE A0 A1 A6 A9 Auto-Select Manufacturer Code (1) L L H L L L L VID Code H Auto-Select Device Code (1) L L H L H L L VID Code H Read (3) L L H A-1 A0 A1 A6 A9 DOUT H Standby H X X X X X X X HIGH-Z H Output Disable L H H X X X X X HIGH-Z H Write L H L A-1 A0 A1 A6 A9 DIN H Enable Sector Protection (2) L VID L X X L VID X H Verify Sector Protection (2) L L H L L H L VID Code H Temporary Sector Unprotection X X X X X X X X X VID Reset (Hardware)/Standby X X X X X X X X HIGH-Z L Operation Legend: L = VIL, H = VIH, X = VIL or VIH, DQ0 to DQ7 RESET = Pulse input. See DC Characteristics for voltage levels. Notes: 1. Manufacturer and device codes may also be accessed via a command register write sequence. Refer to Table 7. 2. Refer to the section on Sector Protection. 3. WE can be VIL if OE is VIL, OE at VIH initiates the write operations. 8 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ ORDERING INFORMATION Standard Products Fujitsu standard products are available in several packages. The order number is formed by a combination of: MBM29F400 T C -55 PFTN PACKAGE TYPE PFTN = 48-Pin Thin Small Outline Package (TSOP (I)) Standard Pinout PFTR = 48-Pin Thin Small Outline Package (TSOP (I)) Reverse Pinout PF = 44-Pin Small Outline Package SPEED OPTION See Product Selector Guide C = Device Revision BOOT CODE SECTOR ARCHITECTURE T = Top sector B = Bottom sector DEVICE NUMBER/DESCRIPTION MBM29F400 4Mega-bit (512K × 8-Bit or 256K × 16-Bit) CMOS Flash Memory 5.0 V-only Read, Write, and Erase 9 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ FUNCTIONAL DESCRIPTION Read Mode The MBM29F400TC/BC has two control functions which must be satisfied in order to obtain data at the outputs. CE is the power control and should be used for a device selection. OE is the output control and should be used to gate data to the output pins if a device is selected. Address access time (tACC) is equal to the delay from stable addresses to valid output data. The chip enable access time (tCE) is the delay from stable addresses and stable CE to valid data at the output pins. The output enable access time is the delay from the falling edge of OE to valid data at the output pins (Assuming the addresses have been stable for at least tACC - tCE time). Standby Mode There are two ways to implement the standby mode on the MBM29F400TC/BC devices, one using both the CE and RESET pins; the other via the RESET pin only. When using both pins, a CMOS standby mode is achieved with CE and RESET inputs both held at VCC ± 0.3 V. Under this condition the current consumed is less than 5 µA max. A TTL standby mode is achieved with CE and RESET pins held at VIH. Under this condition the current is reduced to approximately 1mA. During Embedded Algorithm operation, VCC Active current (ICC2) is required even CE = VIH. The device can be read with standard access time (tCE) from either of these standby modes. When using the RESET pin only, a CMOS standby mode is achieved with RESET input held at VSS ± 0.3 V (CE = “H” or “L”). Under this condition the current is consumed is less than 5 µA max. A TTL standby mode is achieved with RESET pin held at VIL, (CE= “H” or “L”). Under this condition the current required is reduced to approximately 1mA. Once the RESET pin is taken high, the device requires tRH of wake up time before outputs are valid for read access. In the standby mode the outputs are in the high impedance state, independent of the OE input. Output Disable With the OE input at a logic high level (VIH), output from the device is disabled. This will cause the output pins to be in a high impedance state. Autoselect The autoselect mode allows the reading out of a binary code from the device and will identify its manufacturer and type. This mode is intended for use by programming equipment for the purpose of automatically matching the devices to be programmed with its corresponding programming algorithm. This mode is functional over the entire temperature range of the device. To activate this mode, the programming equipment must force VID (11.5 V to 12.5 V) on address pin A9. Two identifier bytes may then be sequenced from the devices outputs by toggling address A0 from VIL to VIH. All addresses are don't cares except A0, A1 and A6 ( A-1) (See Tables 4.1). The manufacturer and device codes may also be read via the command register, for instances when the MBM29F400TC/BC is erased or programmed in a system without access to high voltage on the A9 pin. The command sequence is illustrated in Table 7 (refer to Autoselect Command section). A0 = VIL represents the manufacturer’s code (Fujitsu = 04H) and A0 = VIH the device identifier code (MBM29F400TC = 23H and MBM29F400BC = ABH for ×8 mode; MBM29F400TC = 2223H and MBM29F400BC = 22ABH for ×16 mode). These two bytes/words are given in the tables 4.1 and 4.2. All identifiers for manufacturer and device will exhibit odd parity with DQ7 defined as the parity bit. In order to read the proper device codes when executing the autoselect, A1 must be VIL (See Tables 4.1 and 4.2). 10 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 Table 4 .1 MBM29F400TC/BC Sector Protection Verify Autoselect Codes Type A12 to A17 A6 A1 A0 A-1*1 Code (HEX) X VIL VIL VIL VIL 04H VIL 23H X VIL VIL VIH X 2223H VIL ABH X 22ABH VIL 01H*2 Manufacturer’s Code Byte MBM29F400TC Word Device Code Byte MBM29F400BC X VIL VIL VIH Word Sector Addresses Sector Protection VIH VIL VIL *1: A-1 is for Byte mode. *2: Outputs 01H at protected sector addresses and outputs 00H at unprotected sector addresses. Table 4 .2 Expanded Autoselect Code Table Type Manufacturer’s Code Device Code DQ DQ DQ DQ DQ DQ DQ Code DQ15 DQ14 DQ13 DQ12 DQ11 DQ10 DQ9 DQ8 DQ 7 6 5 4 3 2 1 0 0 0 0 0 0 1 0 0 MBM29F400TC 23H A-1 HI-Z HI-Z HI-Z HI-Z HI-Z HI-Z HI-Z 0 (B) 2223 0 0 1 0 0 0 1 0 0 (W) H 0 0 1 1 0 0 0 0 0 0 1 1 1 1 MBM29F400BC ABH A-1 HI-Z HI-Z HI-Z HI-Z HI-Z HI-Z HI-Z 1 (B) 22AB 0 0 1 0 0 0 1 0 1 (W) H 0 0 1 1 0 0 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 Sector Protection 04H A-1/0 01H A-1/0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (B): Byte mode (W): Word mode Write Device erasure and programming are accomplished via the command register. The contents of the register serve as inputs to the internal state machine. The state machine outputs dictate the function of the device. The command register itself does not occupy any addressable memory location. The register is a latch used to store the commands, along with the address and data information needed to execute the command. The command register is written by bringing WE to VIL, while CE is at VIL and OE is at VIH. Addresses are latched on the falling edge of WE or CE, whichever happens later; while data is latched on the rising edge of WE or CE, whichever happens first. Standard microprocessor write timings are used. Refer to AC Write Characteristics and the Erase/Programming Waveforms for specific timing parameters. Sector Protection The MBM29F400TC/BC features hardware sector protection. This feature will disable both program and erase operations in any number of sectors (0 through 10). The sector protection feature is enabled using programming equipment at the user’s site. The device is shipped with all sectors unprotected. 11 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 To activate this mode, the programming equipment must force VID on address pin A9 and control pin OE, (suggest VID = 11.5V), CE = VIL, and A6 = VIL. The sector addresses (A17, A16, A15, A14, A13, and A12) should be set to the sector to be protected. Tables 5 and 6 define the sector address for each of the eleven (11) individual sectors. Programming of the protection circuitry begins on the falling edge of the WE pulse and is terminated with the rising edge of the same. Sector addresses must be held constant during the WE pulse. Refer to Figures 16 and 23 for sector protection waveforms and algorithm. To verify programming of the protection circuitry, the programming equipment must force VID on address pin A9 with CE and OE at VIL and WE at VIH. Scanning the sector addresses (A17, A16, A15, A14, A13, and A12) while (A6, A1, A0) = (0, 1, 0) will produce a logical “1” code at device output DQ0 for a protected sector. Otherwise the devices will produce 00H for unprotected sector. In this mode, the lower order addresses, except for A0, A1, and A6 are don't care. Address locations with A1 = VIL are reserved for Autoselect manufacturer and device codes. A-1 requires to apply to VIL on byte mode. It is also possible to determine if a sector is protected in the system by writing an Autoselect command. Performing a read operation at the address location XX02H, where the higher order addresses (A17, A16, A15, A14, A13, and A12) are the desired sector address will produce a logical “1” at DQ0 for a protected sector. See Tables 4.1 and 4.2 for Autoselect codes. Temporary Sector Unprotection This feature allows temporary unprotection of previously protected sectors of the MBM29F400TC/BC device in order to change data. The Sector Unprotection mode is activated by setting the RESET pin to high voltage (12 V). During this mode, formerly protected sectors can be programmed or erased by selecting the sector addresses. Once the 12 V is taken away from the RESET pin, all the previously protected sectors will be protected again. Refer to Figures 17 and 24. 12 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 Table 5 Sector Address Tables (MBM29F400TC) Sector Address A17 A16 A15 A14 A13 A12 Address Range SA0 0 0 0 X X X 00000H to 0FFFFH SA1 0 0 1 X X X 10000H to 1FFFFH SA2 0 1 0 X X X 20000H to 2FFFFH SA3 0 1 1 X X X 30000H to 3FFFFH SA4 1 0 0 X X X 40000H to 4FFFFH SA5 1 0 1 X X X 50000H to 5FFFFH SA6 1 1 0 X X X 60000H to 6FFFFH SA7 1 1 1 0 X X 70000H to 77FFFH SA8 1 1 1 1 0 0 78000H to 79FFFH SA9 1 1 1 1 0 1 7A000H to 7BFFFH SA10 1 1 1 1 1 X 7C000H to 7FFFFH Table 6 Sector Address Tables (MBM29F400BC) Sector Address A17 A16 A15 A14 A13 A12 Address Range SA0 0 0 0 0 0 X 00000H to 03FFFH SA1 0 0 0 0 1 0 04000H to 05FFFH SA2 0 0 0 0 1 1 06000H to 07FFFH SA3 0 0 0 1 X X 08000H to 0FFFFH SA4 0 0 1 X X X 10000H to 1FFFFH SA5 0 1 0 X X X 20000H to 2FFFFH SA6 0 1 1 X X X 30000H to 3FFFFH SA7 1 0 0 X X X 40000H to 4FFFFH SA8 1 0 1 X X X 50000H to 5FFFFH SA9 1 1 0 X X X 60000H to 6FFFFH SA10 1 1 1 X X X 70000H to 7FFFFH 13 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 Table 7 Command Sequence Read/Reset Read/Reset Autoselect Program Chip Erase Sector Erase Bus Write Cycles Req'd Word Byte Word Byte Word Byte Word Byte Word Byte Word Byte 1 3 3 4 6 6 MBM29F400TC/BC Command Definitions Second Bus Fifth Bus First Bus Third Bus Fourth Sixth Bus Bus Read/Write Write Cycle Write Cycle Write Cycle Write Cycle Write Cycle Cycle Addr Data Addr Data Addr Data Addr Data Addr Data Addr Data XXXH F0H 555H AAAH 555H AAAH 555H AAAH 555H AAAH 555H AAAH AAH AAH AAH AAH AAH — 2AAH 555H 2AAH 555H 2AAH 555H 2AAH 555H 2AAH 555H — 55H 55H 55H 55H 55H — 555H AAAH 555H AAAH 555H AAAH 555H AAAH 555H AAAH — — — — — — — F0H RA RD — — — — 90H — — — — — — A0H PA PD — — — — 80H 80H 555H AAAH 555H AAAH AAH AAH 2AAH 555H 2AAH 555H 55H 555H AAAH 55H SA 10H 30H Sector Erase Suspend Erase can be suspended during sector erase with Addr (“H” or “L”). Data (B0H) Sector Erase Resume Erase can be resumed after suspend with Addr (“H” or “L”). Data (30H) Notes: 1. Address bits A15 to A11 = X = “H” or “L” for all address commands except or Program Address (PA) and Sector Address (SA). 2. Bus operations are defined in Tables 2 and 3. 3. RA = Address of the memory location to be read. PA = Address of the memory location to be programmed. Addresses are latched on the falling edge of the WE pulse. SA = Address of the sector to be erased. The combination of A17, A16, A15, A14, A13, and A12 will uniquely select any sector. 4. RD = Data read from location RA during read operation. PD = Data to be programmed at location PA. Data is latched on the falling edge of WE. 5. The system should generate the following address patterns: Word Mode: 555H or 2AAH to addresses A0 to A10 Byte Mode: AAAH or 555H to addresses A-1 to A10 6. Both Read/Reset commands are functionally equivalent, resetting the device to the read mode. Command Definitions Device operations are selected by writing specific address and data sequences into the command register. Writing incorrect address and data values or writing them in the improper sequence will reset the device to the read mode. Table 7 defines the valid register command sequences. Note that the Erase Suspend (B0H) and Erase Resume (30H) commands are valid only while the Sector Erase operation is in progress. Moreover both Read/Reset commands are functionally equivalent, resetting the device to the read mode. Please note that commands are always written at DQ0 to DQ7 and DQ8 to DQ15 bits are ignored. Read/Reset Command The read or eset operation is initiated by writing the read/reset command sequence into the command register. Microprocessor read cycles retrieve array data from the memory. The devices remain enabled for reads until the command register contents are altered. 14 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 The device will automatically power-up in the read/reset state. In this case, a command sequence is not required to read data. Standard microprocessor read cycles will retrieve array data. This default value ensures that no spurious alteration of the memory content occurs during the power transition. Refer to the AC Read Characteristics and Waveforms for the specific timing parameters. Autoselect Command Flash memories are intended for use in applications where the local CPU alters memory contents. As such, manufacture and device codes must be accessible while the devices reside in the target system. PROM programmers typically access the signature codes by raising A9 to a high voltage. However, multiplexing high voltage onto the address lines is not generally desired system design practice. The device contains an autoselect command operation to supplement traditional PROM programming methodology. The operation is initiated by writing the autoselect command sequence into the command register. Following the command write, a read cycle from address XX00H retrieves the manufacture code of 04H. A read cycle from address XX01H for ×16 (XX02H for ×8) returns the device code (MBM29F400TC = 23H and MBM29F400BC = ABH for ×8 mode; MBM29F400TC = 2223H and MBM29F400BC = 22ABH for ×16 mode). (See Tables 4.1 and 4.2.) All manufacturer and device codes will exhibit odd parity with DQ7 defined as the parity bit. Scanning the sector addresses (A17, A16, A15, A14, A13, and A12) while (A6, A1, A0) = (0, 1, 0) will produce a logical “1” at device output DQ0 for a protected sector. The programming verification should be perform margin mode on the protected sector (See Tables 2 and 3). To terminate the operation, it is necessary to write the read/reset command sequence into the register and also to write the autoselect command during the operation, execute it after writing read/reset command sequence. Byte/Word Programming The device is programmed on a byte-by-byte (or word-by-word) basis. Programming is a four bus cycle operation. There are two “unlock” write cycles. These are followed by the program set-up command and data write cycles. Addresses are latched on the falling edge of CE or WE, whichever happens later and the data is latched on the rising edge of CE or WE, whichever happens first. The rising edge of CE or WE (whichever happens first) begins programming. Upon executing the Embedded ProgramTM Algorithm command sequence the system is not required to provide further controls or timings. The device will automatically provide adequate internally generated program pulses and verify the programmed cell margin. The automatic programming operation is completed when the data on DQ7 is equivalent to data written to this bit at which time the devices return to the read mode and addresses are no longer latched (see Table 8, Hardware Sequence Flags) Therefore, the devices require that a valid address to the devices be supplied by the system at this particular instance of time. Hence, Data Polling must be performed at the memory location which is being programmed. Any commands written to the chip during this period will be ignored. If hardware reset occurs during the programming operation, it is impossible to guarantee the data are being written. Programming is allowed in any sequence and across sector boundaries. Beware that a data “0” cannot be programmed back to a “1”. Attempting to do so may either hang up the device or result in an apparent success according to the data polling algorithm but a read from read/reset mode will show that the data is still “0”. Only erase operations can convert “0”s to “1”s. Figure 19 illustrates the Embedded Programming Algorithm using typical command strings and bus operations. Chip Erase Chip erase is a six bus cycle operation. There are two “unlock” write cycles. These are followed by writing the “set-up” command. Two more “unlock” write cycles are then followed by the chip erase command. 15 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 Chip erase does not require the user to program the device prior to erase. Upon executing the Embedded EraseTM Algorithm command sequence the device will automatically program and verify the entire memory for an all zero data pattern prior to electrical erase. The system is not required to provide any controls or timings during these operations. The automatic erase begins on the rising edge of the last WE pulse in the command sequence and terminates when the data on DQ7 is “1” (see Write Operation Status section) at which time the device returns to read the mode. Figure 20 illustrates the Embedded Erase Algorithm using typical command strings and bus operations. Sector Erase Sector erase is a six bus cycle operation. There are two “unlock” write cycles. These are followed by writing the “set-up” command. Two more “unlock” write cycles are then followed by the sector erase command. The sector address (any address location within the desired sector) is latched on the falling edge of WE, while the command (Data = 30H) is latched on the rising edge of WE. After time-out of 50 µs from the rising edge of the last sector erase command, the sector erase operation will begin. Multiple sectors may be erased concurrently by writing the six bus cycle operations on Table 7. This sequence is followed with writes of the Sector Erase command to addresses in other sectors desired to be concurrently erased. The time between writes must be less than 50 µs otherwise that command will not be accepted and erasure will start. It is recommended that processor interrupts be disabled during this time to guarantee this condition. The interrupts can be re-enabled after the last Sector Erase command is written. A time-out of 50 µs from the rising edge of the last WE will initiate the execution of the Sector Erase command(s). If another falling edge of the WE occurs within the 50 µs time-out window the timer is reset. (Monitor DQ3 to determine if the sector erase timer window is still open, see section DQ3, Sector Erase Timer.) Any command other than Sector Erase or Erase Suspend during this time-out period will reset the devices to the read mode, ignoring the previous command string. Resetting the device once execution has begun will corrupt the data in that sector. In that case, restart the erase on those sectors and allow them to complete. (Refer to the Write Operation Status section for Sector Erase Timer operation.) Loading the sector erase buffer may be done in any sequence and with any number of sectors (0 to 10). Sector erase does not require the user to program the devices prior to erase. The device automatically programs all memory locations in the sector(s) to be erased prior to electrical erase. When erasing a sector or sectors the remaining unselected sectors are not affected. The system is not required to provide any controls or timings during these operations. The automatic sector erase begins after the 50 µs time out from the rising edge of the WE pulse for the last sector erase command pulse and terminates when the data on DQ7 is “1” (see Write Operation Status section) at which time the device returns to the read mode. Data polling must be performed at an address within any of the sectors being erased. Figure 20 illustrates the Embedded Erase Algorithm using typical command strings and bus operations. Erase Suspend The Erase Suspend command allows the user to interrupt a Sector Erase operation and then perform data reads from or programs to a sector not being erased. This command is applicable ONLY during the Sector Erase operation which includes the time-out period for sector erase. The Erase Suspend command will be ignored if written during the Chip Erase operation or Embedded Program Algorithm. Writting the Erase Suspend command during the Sector Erase time-out results in immediate termination of the time-out period and suspension of the erase operation. Writing the Erase Resume command resumes the erase operation. The addresses are “don’t cares” when writing the Erase Suspend or Erase Resume command. 16 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 When the Erase Suspend command is written during the Sector Erase operation, the device will take a maximum of 20 µs to suspend the erase operation. When the device has entered the erase-suspended mode, the RY/BY output pin and the DQ7 bit will be at logic “1”, and DQ6 will stop toggling. The user must use the address of the erasing sector for reading DQ6 and DQ7 to determine if the erase operation has been suspended. Further writes of the Erase Suspend command are ignored. When the erase operation has been suspended, the device defaults to the erase-suspend-read mode. Reading data in this mode is the same as reading from the standard read mode except that the data must be read from sectors that have not been erase-suspended. Successively reading from the erase-suspended sector while the device is in the erase-suspend-read mode will cause DQ2 to toggle. (See the section on DQ2). After entering the erase-suspend-read mode, the user can program the device by writing the appropriate command sequence for Program. This program mode is known as the erase-suspend-program mode. Again, programming in this mode is the same as programming in the regular Program mode except that the data must be programmed to sectors that are not erase-suspended. Successively reading from the erase-suspended sector while the device is in the erase-suspend-program mode will cause DQ2 to toggle. The end of the erase-suspended program operation is detected by the RY/BY output pin, Data polling of DQ7, or by the Toggle Bit I (DQ6) which is the same as the regular Program operation. Note that DQ7 must be read from the program address while DQ6 can be read from any address. To resume the operation of Sector Erase, the Resume command (30H) should be written. Any further writes of the Resume command at this point will be ignored. Another Erase Suspend command can be written after the chip has resumed erasing. Write Operation Status Table 8 Hardware Sequence Flags Status DQ7 DQ6 DQ5 DQ3 DQ2 DQ7 Toggle 0 0 1 0 Toggle 0 1 Toggle 1 1 0 0 Toggle Erase Suspend Read (Non-Erase Suspended Sector) Data Data Data Data Data Erase Suspend Program (Non-Erase Suspended Sector) DQ7 Toggle (Note 1) 0 0 1 (Note 2) DQ7 Toggle 1 0 1 0 Toggle 1 1 N/A DQ7 Toggle 1 0 N/A Embedded Program Algorithm Embedded Erase Algorithm In Progress Erase Suspend Read (Erase Suspended Sector) Erase Suspended Mode Embedded Program Algorithm Exceeded Time Limits Embedded Erase Algorithm Erase Suspended Mode Erase Suspend Program (Non-Erase Suspended Sector) Notes: 1. Performing successive read operations from any address will cause DQ6 to toggle. 2. Reading the byte address being programmed while in the erase-suspend program mode will indicate logic “1” at the DQ2 bit. However, successive reads from the erase-suspended sector will cause DQ2 to toggle. 3. DQ0 and DQ1 are reserve pins for future use. DQ4 is Fujitsu internal use only. 4. DQ8 to DQ15 are “DON’T CARES” because there is for × 16 mode. 17 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 DQ7 Data Polling The MBM29F400TC/BC device feature Data Polling as a method to indicate to the host that the Embedded Algorithms are in progress or completed. During the Embedded Program Algorithm an attempt to read the device will produce the complement of the data last written to DQ7. Upon completion of the Embedded Program Algorithm, an attempt to read the device will produce the true data last written to DQ7. During the Embedded Erase Algorithm, an attempt to read the device will produce a “0” at the DQ7 output. Upon completion of the Embedded Erase Algorithm an attempt to read the device will produce a “1” at the DQ7 output. The flowchart for Data Polling (DQ7) is shown in Figure 21. For Programing, the Data Polling is valid after the rising edge of fourth write pulse in the four write pulse sequence. For chip erase and sector erase, the Data Polling is valid after the rising edge of the sixth write pulse in the six write pulse sequence. Data Polling must be performed at sector address within any of the sectors being erased and not a protected sector. Otherwise, the status may not be valid. Once the Embedded Algorithm operation is close to being completed, the MBM29F400TC/BC data pins (DQ7) may change asynchronously while the output enable (OE) is asserted low. This means that the device is driving status information on DQ7 at one instant of time and then that byte’s valid data at the next instant of time. Depending on when the system samples the DQ7 output, it may read the status or valid data. Even if the device has completed the Embedded Algorithm operation and DQ7 has a valid data, the data outputs on DQ0 to DQ6 may be still invalid. The valid data on DQ0 to DQ7 will be read on the successive read attempts. The Data Polling feature is only active during the Embedded Programming Algorithm, Embedded Erase Algorithm or sector erase time-out (See Table 8). See Figure 9 for the Data Polling timing specifications and diagrams. DQ6 Toggle Bit I The MBM29F400TC/BC also feature the “Toggle Bit I” as a method to indicate to the host system that the Embedded Algorithms are in progress or completed. During an Embedded Program or Erase Algorithm cycle, successive attempts to read (OE toggling) data from the device will result in DQ6 toggling between one and zero. Once the Embedded Program or Erase Algorithm cycle is completed, DQ6 will stop toggling and valid data will be read on the next successive attempts. During programming, the Toggle Bit I is valid after the rising edge of the fourth write pulse in the four write pulse sequence. For chip erase and sector erase, the Toggle Bit I is valid after the rising edge of the sixth write pulse in the six write pulse sequence. The Toggle Bit I is active during the sector time out. In programming, if the sector being written to is protected, the toggle bit l will toggle for about 2 µs and then stop toggling without the data having changed. In erase, the device will erase all the selected sectors except for the ones that are protected. If all selected sectors are protected, the chip will toggle the toggle bit for about 100 µs and then drop back into read mode, having changed none of the data. Either CE or OE toggling will cause the DQ6 to toggle. In addition, an Erase Suspend/Resume command will cause DQ6 to toggle. See Figure 10 for the Toggle Bit I timing specifications and diagrams. DQ5 Exceeded Timing Limits DQ5 will indicate if the program or erase time has exceeded the specified limits (internal pulse count). Under these conditions DQ5 will produce a “1”. This is a failure condition which indicates that the program or erase cycle was not successfully completed. Data Polling is the only operating function of the devices under this 18 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 condition. The CE circuit will partially power down the device under these conditions (to approximately 2 mA). The OE and WE pins will control the output disable functions as described in Tables 2 and 3. The DQ5 failure condition may also appear if a user tries to program a non blank location without erasing. In this case the device locks out and never complete the Embedded Algorithm operation. Hence, the system never reads a valid data on DQ7 bit and DQ6 never stops toggling. Once the device has exceeded timing limits, the DQ5 bit will indicate a “1.” Please note that this is not a device failure condition since the device was incorrectly used. DQ3 Sector Erase Timer After the completion of the initial sector erase command sequence the sector erase time-out will begin. DQ3 will remain low until the time-out is complete. Data Polling and Toggle Bit are valid after the initial sector erase command sequence. If Data Polling or the Toggle Bit I indicates the device has been written with a valid erase command, DQ3 may be used to determine if the sector erase timer window is still open. If DQ3 is high (“1”) the internally controlled erase cycle has begun; attempts to write subsequent commands to the device will be ignored until the erase operation is completed as indicated by Data Polling or Toggle Bit I. If DQ3 is low (“0”), the device will accept additional sector erase commands. To insure the command has been accepted, the system software should check the status of DQ3 prior to and following each subsequent sector erase command. If DQ3 were high on the second status check, the command may not have been accepted. Refer to Table 8: Hardware Sequence Flags. DQ2 Toggle Bit II This toggle bit II, along with DQ6, can be used to determine whether the device is in the Embedded Erase Algorithm or in Erase Suspend. Successive reads from the erasing sector will cause DQ2 to toggle during the Embedded Erase Algorithm. If the device is in the erase-suspended-read mode, successive reads from the erase-suspended sector will cause DQ2 to toggle. When the device is in the erase-suspended-program mode, successive reads from the byte address of the non-erase suspended sector will indicate a logic “1” at the DQ2 bit. DQ6 is different from DQ2 in that DQ6 toggles only when the standard program or Erase, or Erase Suspend Program operation is in progress. The behavior of these two status bits, along with that of DQ7, is summarized as follows: DQ7 DQ6 DQ2 DQ7 toggles 1 Erase 0 toggles toggles Erase Suspend Read (Erase-Suspended Sector) (Note 1) 1 1 toggles DQ7 (Note 2) toggles 1 (Note 2) Mode Program Erase Suspend Program Notes: 1. These status flags apply when outputs are read from a sector that has been erase-suspended. 2. These status flags apply when outputs are read from the byte address of the non-erase suspended sector. For example, DQ2 and DQ6 can be used together to determine the erase-suspend-read mode (DQ2 toggles while DQ6 does not). See also Table 8 and Figure 22. 19 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 Furthermore, DQ2 can also be used to determine which sector is being erased. When the device is in the erase mode, DQ2 toggles if this bit is read from the erasing sector. RY/BY Ready/Busy The MBM29F400TC/BC provides a RY/BY open-drain output pin as a way to indicate to the host system that the EmbeddedTM Algorithms are either in progress or completed. If the output is low, the device is busy with either a program or erase operation. If the output is high, the device is ready to accept any read/write or erase operation. When the RY/BY pin is low, the device will not accept any additional program or erase commands. If the MBM29F400TC/BC is placed in an Erase Suspend mode, the RY/BY output will be high. Also, since this is an open drain output, many RY/BY pins can be tied together in parallel with a pull up resistor to VCC. During programming, the RY/BY pin is driven low after the rising edge of the fourth write pulse. During an erase operation, the RY/BY pin is driven low after the rising edge of the sixth write pulse. The RY/BY pin will indicate a busy condition during the RESET pulse. Refer to Figure 11 and 12 for a detailed timing diagram. Since this is an open-drain output, several RY/BY pins can be tied together in parallel with a pull-up resistor to VCC. RESET Hardware Reset The MBM29F400TC/BC device may be reset by driving the RESET pin to VIL. The RESET pin has a pulse requirement and has to be kept low (VIL) for at least 500 ns in order to properly reset the internal state machine. Any operation in the process of being executed will be terminated and the internal state machine will be reset to the read mode 20 µs after the RESET pin is driven low. Furthermore, once the RESET pin goes high, the device requires time of tRH before it will allow read access. When the RESET pin is low, the device will be in the standby mode for the duration of the pulse and all the data output pins will be tri-stated. If a hardware reset occurs during a program or erase operation, the data at that particular location will be corrupted. Please note that the RY/BY output signal should be ignored during the RESET pulse. Refer to Figure 12 for the timing diagram. Refer to Temporary Sector Unprotection for additional functionality. If hardware reset occurs during Embedded Erase Algorithm, there is a possibility that the erasing sector(s) cannot be used. Byte/Word Configuration The BYTE pin selects the byte (8-bit) mode or word (16-bit) mode for the MBM29F400TC/BC device. When this pin is driven high, the device operates in the word (16-bit) mode. The data is read and programmed at DQ0 to DQ15. When this pin is driven low, the device operates in byte (8-bit) mode. Under this mode, the DQ15/A-1 pin becomes the lowest address bit and DQ8 to DQ14 bits are tri-stated. However, the command bus cycle is always an 8-bit operation and hence commands are written at DQ0 to DQ7 and the DQ8 to DQ15 bits are ignored. Refer to Figures 13, 14 and 15 for the timing diagram. Data Protection The MBM29F400TC/BC are designed to offer protection against accidental erasure or programming caused by spurious system level signals that may exist during power transitions. During power up the device automatically resets the internal state machine in the read mode. Also, with its control register architecture, alteration of the memory contents only occurs after successful completion of specific multi-bus cycle command sequences. The device also incorporate several features to prevent inadvertent write cycles resulting form VCC power-up and power-down transitions or system noise. 20 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 Low VCC Write Inhibit To avoid initiation of a write cycle during VCC power-up and power-down, a write cycle is locked out for VCC less than 3.2 V (typically 3.7 V). If VCC < VLKO, the command register is disabled and all internal program/erase circuits are disabled. Under this condition the device will reset to the read mode. Subsequent writes will be ignored until the VCC level is greater than VLKO. It is the users responsibility to ensure that the control pins are logically correct to prevent unintentional writes when VCC is above 3.2 V. If Embedded Erase Algorithm is interrupted, there is possibility that the erasing sector(s) cannot be used. Write Pulse “Glitch” Protection Noise pulses of less than 5 ns (typical) on OE, CE, or WE will not initiate a write cycle. Logical Inhibit Writing is inhibited by holding any one of OE = VIL, CE = VIH, or WE = VIH. To initiate a write cycle CE and WE must be a logical zero while OE is a logical one. Power-Up Write Inhibit Power-up of the device with WE = CE = VIL and OE = VIH will not accept commands on the rising edge of WE. The internal state machine is automatically reset to the read mode on power-up. 21 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ ABSOLUTE MAXIMUM RATINGS Storage Temperature .................................................................................................. –55°C to +125°C Ambient Temperature with Power Applied .................................................................. –40°C to +85°C Voltage with respect to Ground All pins except A9, OE, RESET (Note 1) ................... –2.0 V to +7.0 V VCC (Note 1) ................................................................................................................ –2.0 V to +7.0 V A9, OE, RESET (Note 2) ............................................................................................. –2.0 V to +13.5 V Notes: 1. Minimum DC voltage on input or I/O pins are –0.5 V. During voltage transitions, inputs may negative overshoot VSS to –2.0 V for periods of up to 20 ns. Maximum DC voltage on output and I/O pins are VCC +0.5 V. During voltage transitions, outputs may positive overshoot to VCC +2.0 V for periods of up to 20 ns. 2. Minimum DC input voltage on A9, OE, RESET pins are –0.5 V. During voltage transitions, A9, OE, RESET pins may negative overshoot VSS to –2.0 V for periods of up to 20 ns. Maximum DC input voltage on A9, OE, RESET pins are +13.0 V which may positive overshoot to 14.0 V for periods of up to 20 ns. Voltage difference between input voltage and power supply. (VIN - VCC) do not exceed 9 V. WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current, temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings. ■ RECOMMENDED OPERATING RANGES Commercial Devices Ambient Temperatue (TA) .............................................................................–40°C to +85°C VCC Supply Voltages MBM29F400TC/BC-55..............................................................................+4.75 V to +5.25 V MBM29F400TC/BC-70/-90 .......................................................................+4.50 V to +5.50 V Operating ranges define those limits between which the functionality of the devices are guaranteed. WARNING: The recommended operating conditions are required in order to ensure the normal operation of the semiconductor device. All of the device’s electrical characteristics are warranted when the device is operated within these ranges. Always use semiconductor devices within their recommended operating condition ranges. Operation outside these ranges may adversely affect reliability and could result in device failure. No warranty is made with respect to uses, operating conditions, or combinations not represented on the data sheet. Users considering application outside the listed conditions are advised to contact their FUJITSU representatives beforehand. 22 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ MAXIMUM OVERSHOOT 20 ns 20 ns +0.8 V –0.5 V –2.0 V 20 ns Figure 1 Maximum Negative Overshoot Waveform 20 ns VCC+2.0 V VCC+0.5 V +2.0 V 20 ns Figure 2 20 ns Maximum Positive Overshoot Waveform 20 ns +14.0 V +13.0 V VCC+0.5 V 20 ns 20 ns Note: This waveform is applied for A9, OE, and RESET. Figure 3 Maximum Positive Overshoot Waveform 23 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ DC CHARACTERISTICS Parameter Symbol Parameter Description Test Conditions Min. Max. Unit ILI Input Leakage Current VIN = VSS to VCC, VCC = VCC Max. –1.0 +1.0 µA ILO Output Leakage Current VOUT = VSS to VCC, VCC = VCC Max. –1.0 +1.0 µA ILIT A9, OE, RESET Inputs Leakage Current VCC = VCC Max. A9, OE, RESET = 12.5 V — 50 µA ICC1 VCC Active Current (Note 1) CE = VIL, OE = VIH Byte 35 — Word ICC2 ICC3 ICC4 VCC Active Current (Note 2) VCC Current (Standby) mA 40 CE = VIL, OE = VIH — 50 mA VCC = VCC Max., CE = VIH, RESET = VIH — 1 mA VCC = VCC Max., CE = VCC ± 0.3 V, RESET = VCC ± 0.3 V — 5 µA VCC = VCC Max., RESET = VIL — 1 mA VCC = VCC Max., RESET = VSS ± 0.3 V — 5 µA VCC Current (Standby, Reset) VIL Input Low Level — –0.5 0.8 V VIH Input High Level — 2.0 VCC + 0.5 V VID Voltage for Autoselect and Sector Protection (A9, OE, RESET) (Note 3, 4) — 11.5 12.5 V VOL Output Low Voltage Level IOL = 5.8mA, VCC = VCC Min. — 0.45 V IOH = –2.5 mA, VCC = VCC Min. 2.4 — V VCC – 0.4 — V 3.2 4.2 V VOH1 Output High Voltage Level VOH2 VLKO IOH = –100 µA Low VCC Lock-Out Voltage — Notes: 1. The ICC current listed includes both the DC operating current and the frequency dependent component (at 6 MHz). The frequency component typically is 2 mA/MHz, with OE at VIH. 2. ICC active while Embedded Algorithm (program or erase) is in progress. 3. Applicable to sector protection function. 4. (VID - VCC) do not exceed 9 V. 24 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ AC CHARACTERISTICS • Read Only Operations Characteristics Parameter Symbols Description -55 -70 -90 (Note1) (Note2) (Note2) Unit Test Setup JEDEC Standard tAVAV tRC Read Cycle Time tAVQV tACC Address to Output Delay tELQV tCE Chip Enable to Output Delay tGLQV tOE Output Enable to Output Delay tEHQZ tDF tGHQZ — Min. 55 70 90 ns CE = VIL OE = VIL Max. 55 70 90 ns OE = VIL Max. 55 70 90 ns — Max. 30 30 35 ns Chip Enable to Output High-Z — Max. 15 20 20 ns tDF Output Enable to Output High-Z — Max. 15 20 20 ns tAXQX tOH Output Hold Time From Addresses, CE or OE, Whichever Occurs First — Min. 0 0 0 ns — tREADY RESET Pin Low to Read Mode — Max. 20 20 20 µs — tELFL tELFH CE or BYTE Switching Low or High — Max. 5 5 5 ns Note: 2. Test Conditions: Output Load: 1 TTL gate and 100 pF Input rise and fall times: 5 ns Input pulse levels: 0.45 V to 2.4 V Timing measurement reference level Input: 0.8 V and 2.0 V Output: 0.8 V and 2.0 V Note: 1. Test Conditions: Output Load: 1 TTL gate and 30 pF Input rise and fall times: 5 ns Input pulse levels: 0.0 V to 3.0 V Timing measurement reference level Input: 1.5 V Output: 1.5 V 5.0 V IN3064 or Equivalent 2.7 kΩ Device Under Test 6.2 kΩ CL Diodes = IN3064 or Equivalent Notes: 1. CL = 30 pF including jig capacitance 2. CL = 100 pF including jig capacitance Figure 4 Test Conditions 25 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 • Write/Erase/Program Operations Parameter Symbols MBM29F400TC/BC Description JEDEC Standard tAVAV tWC Write Cycle Time tAVWL tAS tWLAX Unit -55 -70 -90 Min. 55 70 90 ns Address Setup Time Min. 0 0 0 ns tAH Address Hold Time Min. 45 45 45 ns tDVWH tDS Data Setup Time Min. 30 30 45 ns tWHDX tDH Data Hold Time Min. 0 0 0 ns — tOES Output Enable Setup Time Min. 0 0 0 ns 0 0 0 ns tOEH Output Read Enable Hold Toggle and Data Polling Time Min. — Min. 10 10 10 ns tGHWL tGHWL Read Recover Time Before Write Min. 0 0 0 ns tGHEL tGHEL Read Recover Time Before Write Min. 0 0 0 ns tELWL tCS CE Setup Time Min. 0 0 0 ns tWLEL tWS WE Setup Time Min. 0 0 0 ns tWHEH tCH CE Hold Time Min. 0 0 0 ns tEHWH tWH WE Hold Time Min. 0 0 0 ns tWLWH tWP Write Pulse Width Min. 30 35 45 ns tELEH tCP CE Pulse Width Min. 30 35 45 ns tWHWL tWPH Write Pulse Width High Min. 20 20 20 ns tEHEL tCPH CE Pulse Width High Min. 20 20 20 ns tWHWH1 tWHWH1 Byte Programming Operation Typ. 8 8 8 µs Typ. 1 1 1 sec tWHWH2 tWHWH2 Sector Erase Operation (Note 1) Max. 8 8 8 sec — tVCS VCC Setup Time Min. 50 50 50 µs — tVIDR RiseTime to VID Min. 500 500 500 ns — tVLHT Voltage Transition Time (Note 2) Min. 4 4 4 µs — tWPP Write Pulse Width (Note 2) Min. 100 100 100 µs — tOESP OE Setup Time to WE Active (Note 2) Min. 4 4 4 µs — tCSP CE Setup Time to WE Active (Note 2) Min. 4 4 4 µs — tRB Recover Time from RY/BY Min. 0 0 0 ns (Continued) 26 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 (Continued) Parameter Symbols MBM29F400TC/BC Description JEDEC Standard — tRP RESET Pulse Width — tRH — Unit -55 -70 -90 Min. 500 500 500 ns RESET Hold Time Before Read Min. 50 50 50 ns tFLQZ BYTE Switching Low to Output High-Z Max. 30 20 30 ns — tFHQV BYTE Switching High to Output Active Min. 30 20 30 ns — tBUSY Program/Erase Valid to RY/BY Delay Max. 55 70 90 ns — tEOE Delay Time from Embedded Output Enable Max. 30 30 35 ns Notes: 1. This does not include the preprogramming time. 2. These timing is for Sector Protection operation. 27 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ SWITCHING WAVEFORMS • Key to Switching Waveforms WAVEFORM INPUTS OUTPUTS Must Be Steady Will Be Steady May Change from H to L Will Be Changing from H to L May Change from L to H Will Be Changing from L to H “H” or “L” Any Change Permitted Changing State Unknown Does Not Apply Center Line is HighImpedance “Off” State tRC Addresses Stable Addresses tACC CE tDF tOE OE tOEH WE tCE Outputs High-Z Figure 5 28 tOH Output Valid AC Waveforms for Read Operations High-Z MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 3rd Bus Cycle Addresses Data Polling 555H PA PA tAH tWC tRC tAS CE tCH tGHWL OE tWP tWHWH1 WE tCS tWPH tDF tDH A0H Data tOE PD DQ7 DOUT tDS tOH 5.0 V tCE Notes: 1. 2. 3. 4. 5. 6. PA is address of the memory location to be programmed PD is data to be programmed at byte address. DQ7 is the output of the complement of the data written to the device. DOUT is the output of the data written to the device. Figure indicates last two bus cycles out of four bus cycle sequence. These waveforms are for the × 16 mode. Figure 6 AC Waveforms for Alternate WE Controlled Program Operations 29 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 3rd Bus Cycle Addresses Data Polling 555H PA PA tAH tWC tAS tWH WE tGHEL OE tWHWH1 tCP CE tCPH tWS tDH A0H Data PD DQ7 DOUT tDS 5.0 V Notes: 1. 2. 3. 4. 5. 6. PA is address of the memory location to be programmed. PD is data to be programmed at byte address. DQ7 is the output of the complement of the data written to the device. DOUT is the output of the data written to the device. Figure indicates last two bus cycles out of four bus cycle sequence. These waveforms are for the × 16 mode. Figure 7 30 AC Waveforms for Alternate CE Controlled Program Operations MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 tAH Addresses 555H 2AAH 555H 555H 2AAH SA tAS CE tCH tGHWL OE tWP WE tCS tWPH tDH AAH Data 55H 80H AAH 55H 10H/ 30H tDS VCC tVCS Notes: 1. SA is the sector address for Sector Erase. Addresses = 555H (Word), AAAH (Byte) for Chip Erase. 2. These waveforms are for the × 16 mode. The addresses differ from × 8 mode. Figure 8 AC Waveforms Chip/Sector Erase Operations 31 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 tCH CE tDF tOE OE tOEH WE tCE * DQ7 Data DQ7 = Valid Data DQ7 High-Z tWHWH1 or 2 Data DQ0 to DQ6 DQ0 to DQ6 = Output Flag DQ0 to DQ6 Valid Data High-Z *DQ7 = Valid Data (The device has completed the Embedded operation). Figure 9 AC Waveforms for Data Polling during Embedded Algorithm Operations CE tOEH WE tOES OE * DQ6 Data (DQ0 to DQ7) DQ6 = Toggle DQ6 = Stop Toggling DQ6 = Toggle DQ0 to DQ7 Valid tOE *DQ6 stops toggling (The device has completed the Embedded operation). Figure 10 32 AC Waveforms for Toggle Bit I during Embedded Algorithm Operations MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 CE The rising edge of the last WE signal WE Entire programming or erase operations RY/BY tBUSY Figure 11 RY/BY Timing Diagram during Program/Erase Operations WE RESET tRP tRB RY/BY tREADY Figure 12 RESET/RY/BY Timing Diagram 33 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 CE BYTE Data Output (DQ0 to DQ7) DQ0 to DQ14 tELFH DQ15/A-1 Data Output (DQ0 to DQ14) tFHQV DQ15 A-1 Figure 13 Timing Diagram for Word Mode Configuration CE BYTE tELFL DQ0 to DQ14 DQ15/A-1 Data Output (DQ0 to DQ14) Data Output (DQ0 to DQ7) DQ15 A-1 tFLQZ Figure 14 Timing Diagram for Byte Mode Configuration The falling edge of the last write signal CE or WE BYTE tSET (tAS) Figure 15 34 tHOLD (tAH) BYTE Timing Diagram for Write Operations MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 A17, A16, A15 A14, A13, A12 SAX SAY A0 A1 A6 VID 5V A9 tVLHT VID 5V OE tOESP tVLHT tWPP tVLHT tVLHT WE tCSP CE 01H Data tOE tVLHT VCC SAX = Sector Address for initial sector SAY = Sector Address for next sector Note: A-1 is VIL on byte mode. Figure 16 AC Waveforms for Sector Protection Timing Diagram 35 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 VCC tVIDR tVCS tVLHT VID 5V 5V RESET CE WE tVLHT tVLHT Program or Erase Command Sequence RY/BY Unprotection period Figure 17 Enter Embedded Erasing WE Erase Suspend Erase Temporary Sector Unprotection Timing Diagram Enter Erase Suspend Program Erase Suspend Read Erase Suspend Program Erase Resume Erase Suspend Read DQ6 DQ2 Toggle DQ2 and DQ6 with OE Note: DQ2 is read from the erase-suspended sector. Figure 18 36 DQ2 vs. DQ6 Erase Erase Complete MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 EMBEDDED ALGORITHMS Start Write Program Command Sequence (See Below) Data Polling Device Increment Address No Last Address ? Yes Programming Completed Program Command Sequence* (Address/Command): 555H/AAH 2AAH/55H 555H/A0H Program Address/Program Data * : The sequence is applied for × 16 mode. The addresses differ from × 8 mode. Figure 19 Embedded Programming Algorithm 37 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 EMBEDDED ALGORITHMS Start Write Erase Command Sequece (See Below) Data Polling or Toggle Bit Successfully Completed Erasure Completed Chip Erase Command Sequence* (Address/Command): Individual Sector/Multiple Sector* Erase Command Sequence (Address/Command): 555H/AAH 555H/AAH 2AAH/55H 2AAH/55H 555H/80H 555H/80H 555H/AAH 555H/AAH 2AAH/55H 2AAH/55H 555H/10H Sector Address/30H * : The sequence is applied for × 16 mode. The addresses differ from × 8 mode. Sector Address/30H Additional sector erase commands are optional. Sector Address/30H Figure 20 38 Embedded Erase Algorithm MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 VA = Byte address for programming = Any of the sector addresses within the sector being erased during sector erase operation = Any of the sector addresses within the sector not being protected during chip erase operation Start Read Byte (DQ0 to DQ7) Addr. = VA DQ7 = Data? Yes No No DQ5 = 1? Yes Read Byte (DQ0 to DQ7) Addr. = VA DQ7 = Data? Yes No Fail Pass Note: DQ7 is rechecked even if DQ5 = “1” because DQ7 may change simultaneously with DQ5. Figure 21 Data Polling Algorithm 39 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 Start Read Byte (DQ0 to DQ7) Addr. = “H” or “L” No DQ6 = Toggle ? Yes No DQ5 = 1? Yes Read Byte (DQ0 to DQ7) Addr. = “H” or “L” DQ6 = Toggle ? No Yes Fail Pass Note: DQ6 is rechecked even if DQ5 = “1” because DQ6 may stop toggling at the same time as DQ5 changing to “1”. Figure 22 40 Toggle Bit Algorithm MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 Start Setup Sector Addr. (A17, A16, A15, A14, A13, A12) PLSCNT = 1 OE = VID, A9 = VID, A6 = CE = VIL, RESET = VIH Activate WE Pulse Time out 100 µs Increment PLSCNT WE = VIH, CE = OE = VIL (A9 should remain VID) Read from Sector (Addr. = SA, A1 = 1, A0 = V6 = 0)* No No PLSCNT = 25? Yes Remove VID from A9 Write Reset Command Data = 01H? Yes Yes Protect Another Sector? No Device Failed Remove VID from A9 Write Reset Command Sector Protection Completed * : A-1 is VIL on byte mode. Figure 23 Sector Protection Algorithm 41 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 Start RESET = VID (Note 1) Perform Erase or Program Operations RESET = VIH Temporary Sector Unprotection Completed (Note 2) Notes: 1. All protected sectors unprotected. 2. All previously protected sectors are protected once again. Figure 24 42 Temporary Sector Unprotection Algorithm MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ ERASE AND PROGRAMMING PERFORMANCE Limits Parameter Unit Comment 8 sec Excludes 00H programming prior to erasure 16 200 µs — 8 150 µs — 4.2 10 sec 100,000 — — Cycles Min. Typ. Max. Sector Erase Time — 1 Word Programming Time — Byte Programming Time Chip Programming Time Erase/Program Cycle Excludes system-level overhead Excludes system-level overhead ■ TSOP (I) PIN CAPACITANCE Parameter Symbol Parameter Description Test Setup Typ. Max. Unit CIN Input Capacitance VIN = 0 8 9 pF COUT Output Capacitance VOUT = 0 8 10 pF CIN2 Control Pin Capacitance VIN = 0 8.5 11.5 pF Typ. Max. Unit 7.5 9 pF 8 10 pF 8.5 11 pF Note: Test conditions TA = 25°C, f = 1.0 MHz ■ SOP PIN CAPACITANCE Parameter Symbol Parameter Description Test Setup CIN Input Capacitance VIN = 0 COUT Output Capacitance VOUT = 0 CIN2 Control Pin Capacitance VIN = 0 Note: Test conditions TA = 25°C, f = 1.0 MHz 43 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 ■ PACKAGE DIMENSIONS 48-pin plastic TSOP (I) (FPT-48P-M19) *: Resin protrusion. (Each side: 0.15(.006) Max) LEAD No. 1 48 Details of "A" part INDEX 0.15(.006) MAX 0.35(.014) MAX "A" 0.15(.006) 24 25 * 12.00±0.20 20.00±0.20 (.787±.008) * 18.40±0.20 (.724±.008) 0.10(.004) (.472±.008) 11.50REF (.460) 19.00±0.20 (.748±.008) 1996 FUJITSU LIMITED F48029S-2C-2 +0.10 1.10 –0.05 +.004 .043 –.002 (Mounting height) 0.50(.0197) TYP 0.15±0.05 (.006±.002) C 0.25(.010) 0.05(0.02)MIN (STAND OFF) 0.20±0.10 (.008±.004) 0.10(.004) M 0.50±0.10 (.020±.004) Dimension in mm ( inches) (Continued) 44 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 48-pin plastic TSOP (I) (FPT-48P-M20) *: Resin protrusion. (Each side: 0.15(.006) Max) LEAD No. 48 1 Details of "A" part INDEX 0.15(.006) MAX 0.35(.014) MAX "A" 0.15(.006) 0.25(.010) 25 24 19.00±0.20 (.748±.008) 0.50±0.10 (.020±.004) 0.20±0.10 (.008±.004) 0.15±0.10 (.006±.002) 0.10(.004) 0.10(.004) M 0.05(0.02)MIN STAND OFF 0.50(.0197) TYP +0.10 * 18.40±0.20 (.724±.008) 20.00±0.20 (.787±.008) C 1996 FUJITSU LIMITED F48030S-2C-2 11.50(.460)REF 1.10 −0.05 +.004 .043 −.002 (Mounting height) * 12.00±0.20(.472±.008) Dimension in mm ( inches) (Continued) 45 MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 (Continued) 44-pin plastic SOP (FPT-44P-M16) +0.25 +.010 28.45 −0.20 1.120 −.008 2.50(.098)MAX (Mounting height) 0.80±0.20 (.031±.008) 23 44 13.00±0.10 (.512±.004) 16.00±0.20 (.630±.008) 14.40±0.20 (.567±.008) INDEX "A" LEAD No. 1 22 1.27(.050)TYP 0.10(.004) +0.10 0.40 −0.05 +.004 .016 −.002 Ø0.13(.005) M 0.15±0.05 (.006±.002) 0.05(.002)MIN (Stand off) 26.67(1.050)REF C 46 1995 FUJITSU LIMITED F44023S-3C-3 Dimension in mm ( inches) MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90 FUJITSU LIMITED For further information please contact: Japan FUJITSU LIMITED Corporate Global Business Support Division Electronic Devices KAWASAKI PLANT, 4-1-1, Kamikodanaka Nakahara-ku, Kawasaki-shi Kanagawa 211-8588, Japan Tel: 81(44) 754-3763 Fax: 81(44) 754-3329 http://www.fujitsu.co.jp/ North and South America FUJITSU MICROELECTRONICS, INC. Semiconductor Division 3545 North First Street San Jose, CA 95134-1804, USA Tel: (408) 922-9000 Fax: (408) 922-9179 Customer Response Center Mon. - Fri.: 7 am - 5 pm (PST) Tel: (800) 866-8608 Fax: (408) 922-9179 http://www.fujitsumicro.com/ Europe FUJITSU MIKROELEKTRONIK GmbH Am Siebenstein 6-10 D-63303 Dreieich-Buchschlag Germany Tel: (06103) 690-0 Fax: (06103) 690-122 http://www.fujitsu-ede.com/ Asia Pacific FUJITSU MICROELECTRONICS ASIA PTE LTD #05-08, 151 Lorong Chuan New Tech Park Singapore 556741 Tel: (65) 281-0770 Fax: (65) 281-0220 All Rights Reserved. The contents of this document are subject to change without notice. Customers are advised to consult with FUJITSU sales representatives before ordering. The information and circuit diagrams in this document are presented as examples of semiconductor device applications, and are not intended to be incorporated in devices for actual use. Also, FUJITSU is unable to assume responsibility for infringement of any patent rights or other rights of third parties arising from the use of this information or circuit diagrams. FUJITSU semiconductor devices are intended for use in standard applications (computers, office automation and other office equipment, industrial, communications, and measurement equipment, personal or household devices, etc.). CAUTION: Customers considering the use of our products in special applications where failure or abnormal operation may directly affect human lives or cause physical injury or property damage, or where extremely high levels of reliability are demanded (such as aerospace systems, atomic energy controls, sea floor repeaters, vehicle operating controls, medical devices for life support, etc.) are requested to consult with FUJITSU sales representatives before such use. The company will not be responsible for damages arising from such use without prior approval. Any semiconductor devices have an inhereut chance of failure. You must protect against injury, damage or loss from such failures by incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels and other abnormal operating conditions. If any products described in this document represent goods or technologies subject to certain restrictions on export under the Foreign Exchange and Foreign Trade Law of Japan, the prior authorization by Japanese government will be required for export of those products from Japan. http://www.fmap.com.sg/ F9903 FUJITSU LIMITED Printed in Japan 47