MPD MD105MS05HI Md100mhi sery Datasheet

MD100MHI Series
Miniature, 1W SIP
Medical Approved
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
Parameter
Conditions
• 1W Output Power
• 3 kVAC rms Isolation
Input Voltage Range
• Reinforced Insulation
• Miniature SIP Case
• Single & Dual Outputs
• 12 Standard Models
• 2.0 MH MTBF
• Industry Standard Pin-Out
• EN 60950 Approved
• EN 60601 Approved
Input Filter
Reverse Polarity Input Current
Min.
5 VDC Input
4.5
12 VDC Input 10.8
LC Filter
Typ.
5.0
12.0
Max.
5.5
13.2
Units
0.3
A
Max.
±3.0
±1.0
±1.5
Units
%
%
%
150
200
15
±0.02
mV P - P
mV P - P
mV rms
%/°C
Typ.
Max.
15
80
20
100
Units
VAC rms
VPk
G
pF
kHz
Typ.
Max.
+85
+90
+125
Units
°C
°C
°C
95
%
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz), See Note 2
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Typ.
±1.0
Dual Output , Balanced Loads
±0.1
For Vin Change of 1%
±1.2
See Model Selection Guide
100
Over Line, Load & Temp.
±0.01
Momentary (0.5 Sec.)
General
Parameter
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
Min.
60 Seconds 3,000
Flash Tested for 1 Sec 4,500
500 VDC
10
100 kHz, 1V
50
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
Min.
-25
-50
Free Air Convection
RH, Non-condensing
0.87 x 0.30 x 0.49 Inches (22.0 x 7.5 x 12.5 mm)
Non-Conductive Black Plastic (UL94-V0)
0.13 Oz (3.9g)
Reliability Specifications
Parameter
MTBF
Safety Approvals
Conditions
Min.
Typ.
Max.
MIL HDBK 217F, 25°C, Gnd Benign
2.0
UL 60601, UL 60950, EN 60601, EN 60950
Units
MHours
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
5 VDC Input
12 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
Typ.
Max.
9.0
29.0
260
650
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
°C
mW
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Output
Current (mA)
Full-Load No-Load
Voltage
Current
Current
(VDC)
(mA, Max)
(mA, Min)
Load
ciency
Regulation Effi
(%, Typ)
(%, Max)
Fuse Rating
Slow-Blow
(mA)
Nominal
Range
MD105MS-05HI
5
4.5 - 5.5
303
55
5.0
200.0
4.0
10
66
500
MD105MS-12HI
5
4.5 - 5.5
291
55
12.0
80.0
2.0
8
66
500
MD105MS-15HI
5
4.5 - 5.5
295
55
15.0
65.0
1.0
8
66
500
MD105MD-05HI
5
4.5 - 5.5
303
55
±5.0
±100.0
±2.0
10
66
500
MD105MD-12HI
5
4.5 - 5.5
267
55
±12.0
±40.0
±1.0
8
72
500
MD105MD-15HI
5
4.5 - 5.5
287
55
±15.0
±35.0
±1.0
8
73
500
MD112MS-05HI
12
10.8 - 13.2
126
30
5.0
200.0
4.0
10
66
200
MD112MS-12HI
12
10.8 - 13.2
121
30
12.0
80.0
2.0
8
66
200
MD112MS-15HI
12
10.8 - 13.2
123
30
15.0
65.0
1.0
8
66
200
MD112MD-05HI
12
10.8 - 13.2
126
30
±5.0
±100.0
±2.0
10
66
200
MD112MD-12HI
12
10.8 - 13.2
108
30
±12.0
±40.0
±1.0
8
74
200
MD112MD-15HI
12
10.8 - 13.2
117
30
±15.0
±35.0
±1.0
8
75
200
Notes:
1. Output load regulation is specified for a load change of 20% to 100%.
2. When measuring output ripple, it is recomended that an external 0.33 µF
ceramic capacitor be placed from the +Vout pin to the -Vout pin for single
output units and from each output to common for dual output units.
3. Operation at no-load will not damage these units. However, they may not meet
all specifications.
4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC
output. To do this, connect the load across the positive (+Vout) and negative
(-Vout) outputs and float the output common.
5. It is recommended that a fuse be used on the input of a power supply for
protection. See the table above for the correct rating.
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
1
+Vin
+Vin
2
-Vin
-Vin
5
-Vout
-Vout
6
No Pin
Common
7
+Vout
+Vout
NC: No Connection
Capacitive Load
Single Output
Dual Output
µF Max
µF Max
680
±220
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages