TSC DBS106G Single phase 1.0 amp. glass passivated bridge rectifier Datasheet

DB101G THRU DB107G
Single Phase 1.0 AMP. Glass Passivated Bridge Rectifiers
Voltage Range
50 to 1000 Volts
Current
1.0 Ampere
DB
Features
a
a
a
a
a
a
a
DBS
UL Recognized File # E-96005
Ideal for printed circuit board
Reliable low cost construction utilizing
molded plastic technique
High temperature soldering guaranteed:
250°C / 10 seconds / 0.375” ( 9.5mm )
lead length at 5 lbs., ( 2.3 kg ) tension
Small size, simple installation
Leads solderable per MIL-STD-202,
Method 208
High surge current capability
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25°C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Type Number
DB101G DB102G DB103G DB104G DB105G DB106G DB107G
DBS
DBS
DBS
DBS
DBS
DBS
DBS
101G
102G
103G
104G
105G
106G
107G
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
50
35
50
100
70
100
Maximum Average Forward Rectified Current
@TA = 40°C
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated Load
(JEDEC method )
Maximum Instantaneous Forward Voltage
@ 1.0A
Maximum DC Reverse Current @ TA=25°C
at Rated DC Blocking Voltage @ TA=125°C
Operating Temperature Range TJ
Storage Temperature Range TSTG
Note: DBS for Surface Mount Package.
- 470 -
200
140
200
400
280
400
600
420
600
800
560
800
Units
1000
V
700
V
1000
V
1.0
A
50
A
1.1
V
10
500
-55 to +150
-55 to +150
uA
uA
°C
°C
RATINGS AND CHARACTERISTIC CURVES (DB101G THRU DB107G)
FIG.1- MAXIMUM DERATING CURVE FOR OUTPUT
RECTIFIED CURRENT
60
.06" (1.5mm)
PCB
Copper Pauls
.51" x .51"
(13mm x 13mm)
0.5
60Hz RESISTIVE OR
INDUCTIVE LOAD
0
20
40
60
80
100
120
140
PEAK FORWARD SURGE CURRENT. (A)
AVERAGE FORWARD CURRENT. (A)
1.0
FIG.2- MAXIMUM NON-REPETITIVE PEAK FORWARD
SURGE CURRENT
Tj=25 0C
50
Single Sine - Wave
(JEDEC Method)
40
30
20
10
0
150
1
2
o
AMBIENT TEMPERATURE. ( C)
4
6
10
20
40
NUMBER OF CYCLES AT 60Hz
FIG.4- TYPICAL FORWARD CHARACTERISTICS
PER BRIDGE ELEMENT
FIG.3- TYPICAL REVERSE CHARACTERISTICS
PER BRIDGE ELEMENT
100
10
INSTANTANEOUS FORWARD CURRENT. (A)
INSTANTANEOUS REVERSE CURRENT. ( A)
Tj=125 0C
10
1.0
.10
Tj=25 0C
1
0.1
0
Tj=25 C
PULSE WIDTH-300 S
2% DUTY CYCLE
.01
CAPACITANCE.(pF)
100
0
20
40
60
80
100
120
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
1.0
Tj=25 0C
f=1.0MHz
Vsig=50mVp-p
10
0.6
0.8
1.0
1.2
FORWARD VOLTAGE. (V)
FIG.5- TYPICAL JUNCTION CAPACITANCE PER
BRIDGE ELEMENT
10
1
0.01
0.4
140
100
REVERSE VOLTAGE. (V)
- 471-
1.4
1.6
60
100
Similar pages