MORNSUN LH15-13B24 5-25w, ac/dc converter Datasheet

AC/DC Converter
LH(05-25)-13Bxx Series
5-25W, AC/DC converter
FEATURES
z
z
z
z
z
CB
Wide input range: 85~305VAC/100~430VDC
Operating temperature range : -40~70℃
Conversion efficiency up to 87%
Meet IEC60950, EN60950 and UL60950 standards
Over-current, short circuit and over- voltage
protection
RoHS
LH(05-25)-13Bxx series -----a compact size power converter offered by Mornsun. It features universal input voltage, taking both DC and AC
input voltage, low power consumption, high efficiency, high reliability, safer isolation. It offers good EMC performance, which meet
IEC/EN61000-4, CISPR22/EN55022, UL60950 and EN60950 standards, and it’s widely used in industrial, office and civil applications.
Note: Please refer to Design Reference when module being used in a bad EMC environment.
Selection Guide
Certification
Part No.
Output Power
Nominal Output Voltage and
Current(Vo/Io)
Efficiency
(230VAC, %/Typ.)
Max. Capacitive
Load(μF)
LH05-13B03
4W
3.3V/1250mA
72
4000
LH05-13B05
5V/1000mA
77
4000
LH05-13B09
9V/550mA
79
1800
5W
12V/420mA
81
1800
LH05-13B15
15V/330mA
82
1500
LH05-13B24
24V/230mA
84
330
3.3V/2000mA
70
26000
5V/2000mA
76
9400
9V/1100mA
78
3600
12V/900mA
80
2400
LH10-13B15
15V/700mA
81
1200
LH10-13B24
24V/450mA
82
370
LH05-13B12
LH10-13B03
6.6W
LH10-13B05
LH10-13B09
LH10-13B12
10W
LH15-13B03
9.9W
3.3V/3000mA
74
36000
LH15-13B05
14W
5V/2800mA
78
20000
9V/1600mA
79
6000
12V/1250mA
82
3000
15V/1000mA
82
3000
LH15-13B24
24V/625mA
84
900
LH15-13B48
48V/320mA
85
370
LH15-13B09
UL/CE
LH15-13B12
LH15-13B15
15W
LH20-13B03
13.5W
3.3V/3500mA
75
48000
LH20-13B05
17.5W
5V/3500mA
78
12240
LH20-13B09
9V/2100mA
79
5600
LH20-13B12
12V/1600mA
83
5400
15V/1300mA
84
2400
LH20-13B15
20W
24V/850mA
85
1840
LH25-13B03
13.5W
3.3V/4100mA
75
48000
LH25-13B05
20.5W
5V/4100mA
78
12240
9V/2500mA
79
5600
12V/2100mA
83
5400
15V/1600mA
84
2400
LH25-13B24
24V/1100mA
85
1440
LH25-13B48
48V/500mA
87
800
LH20-13B24
LH25-13B09
LH25-13B12
LH25-13B15
25W
2015.03.02-A/1
Page 1 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH(05-25)-13Bxx Series
Input Specifications
Item
Operating Conditions
Input Voltage Range
Min.
Typ.
AC input
85
--
305
VAC
100
--
430
VDC
Hz
115VAC
Input current
230VAC
115VAC
Inrush current
230VAC
47
--
63
LH05 models
--
--
0.125
LH10 models
--
--
0.26
LH15 models
--
--
0.37
LH20/LH25 models
--
--
0.6
LH05 models
--
--
0.08
LH10 models
--
--
0.16
LH15 models
--
--
0.22
LH20/LH25 models
--
--
0.34
LH05/LH10/LH15 models
--
10
--
LH20/LH25 models
--
15
--
LH05/LH10 models
--
15
--
LH15 models
--
20
--
LH20/ LH25 models
--
30
--
0.3mA
Leakage current
LH05 models
Fuse(Special package series include fuse)
Unit
DC input
Input Frequency
Recommended External Input
Max.
A
RMS typ./230VAC/50Hz
1A/300V, slow fusing
LH10/LH15 models
2A/300V, slow fusing
LH20/ LH25 models
3.15A/300V, slow fusing
Hot Plug
Unavailable
Output Specifications
Item
Operating Conditions
Min.
Typ.
Max.
--
±2
--
Full load
--
±0.5
--
Load Regulation
10%-100% load
--
±1
--
Ripple & Noise*
20MHz bandwidth (peak-peak value)
--
50
100
mV
Temperature Coefficient
--
±0.02
--
%/℃
Short Circuit Protection
Hiccup, Continuous, self-recovery
Over-current Protection
≥110%Io self-recovery
Output Voltage Accuracy
Line Regulation
LH05 models
LH10/ LH15/ LH20/ LH25
models
Hold-up Time
≤7.5VDC
9VDC Output
≤12VDC
12 / 15VDC Output
≤20VDC
24VDC Output
≤30VDC
48VDC Output
≤60VDC
0
--
--
LH20/ LH25 models
--
--
±10
115VAC input
--
15
--
230VAC input
--
80
--
Min. Load
Trim
%
Over-voltage shutdown
3.3 / 5VDC Output
Over-voltage Protection
Unit
%
ms
Note: * Ripple and noise tested with “parallel cable” method, please see AC-DC Converter Application Notes for specific operation methods.
General Specifications
Item
Isolation Voltage*
Operating Conditions
Input-output
Input-
Operating Temperature
Test time: 1min
Min.
Typ.
Max.
3000
--
--
2000
--
--
-40
--
+70
2015.03.02-A/1
Unit
VAC
℃
Page 2 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH(05-25)-13Bxx Series
-40
Storage Temperature
Storage Humidity
--
Welding Temperature
Switching Frequency
Power Derating
--
+105
--
95
%RH
Wave-soldering
260±5℃; time:5~10s
Manual-welding
360±10℃; time:3~5s
LH05 models
--
65
132
LH10 models
--
100
--
LH15/LH20/LH25 models
--
65
--
-40℃ to -10℃
2
--
--
50℃ to +70℃ (LH25-13Bxx)
3
--
--
4
--
--
55℃ To +70℃ (Others)
kHz
%/℃
IEC60950/EN60950/UL60950
Safety Standard
EN60950/UL60950
Safety Certification
Safety Class
LH15-13Bxx
CLASS II
Others
CLASS I
MIL-HDBK-217F@25℃ > 300,000 h
MTBF
Note:* There is no pin
on LH15-13Bxx .
Physical Specifications
Casing Material
Black flame-retardant and heat-resistant plastic (UL94-V0)
Package Dimensions
Refer to the Dimensions
Weight
Refer to the Dimensions
Cooling method
Free convection
EMC Specifications
EMI
CE
CISPR22/EN55022, CLASS B
RE
CISPR22/EN55022, CLASS B
ESD
IEC/EN61000-4-2
Contact ±6KV/Air ±8KV
Perf. Criteria B
RS
IEC/EN61000-4-3
10V/m
perf. Criteria A
IEC/EN61000-4-4
±2KV
perf. Criteria B
IEC/EN61000-4-4
±4KV (See Fig. 2 for recommended circuit)
perf. Criteria B
IEC/EN61000-4-5
±1KV/±2KV
perf. Criteria B
IEC/EN61000-4-5
±2KV/4KV (See Fig. 2 for recommended circuit)
perf. Criteria B
EFT
EMS
Surge
CS
IEC/EN61000-4-6
10 Vr.m.s
perf. Criteria A
PFM
Voltage dips, short interruptions
and voltage variations immunity
IEC/EN61000-4-8
10A/m
perf. Criteria A
IEC/EN61000-4-11
0%-70%
perf. Criteria B
Te mperature Derating C ur ve
Other s ser ies
100
LH25-13B seri es
80
60
Inpu t vol tage: 100~ 277VAC
40
20
-40
-10
50 55
Ambient temperature(℃ )
70
Output Power Perc ent(%)
Output Power Percent (%)
Product Characteristic Curve
Input Voltage Derating Cur ve
10 0
80
75
60
40
Ambient temperature :25℃
20
85
10 0
10 0
12 0
27 7
39 0
Input Voltage
30 5
43 0
VAC
VD C
Note: ①Input voltage should be derated based on temperature derating when it is 85-100VAC/277~305VAC/100-120VDC/390~430VDC;
②This product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company’s FAE.
2015.03.02-A/1
Page 3 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH(05-25)-13Bxx Series
100
Efficiency Vs Output Load(Vin=230VAC)
Efficiency Vs Input Voltage(Full Load)
100
LH25-13B24
LH15-13B24
90
90
Efficiency(%)
Efficiency(%)
95
LH25-13B24
85
LH15-13B24
LH05-13B24
80
LH05-13B24
80
70
60
75
70
85
230
277
50
305
10
Input Voltage(VAC)
20
30
40
50
60
70
80
90
100
Output Power Percentage(%)
Design Reference
1. Typical application circuit
AC(L)
FUS E
C1
AC(L) +Vo
C2
TVS1
AC / DC
M OV 1
LOAD
AC(N)
AC(N)
-Vo
Fig. 1
C1(uF)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Model
LH05-13B03
LH05-13B05
LH05-13B09
LH05-13B12
LH05-13B15
LH05-13B24
LH10-13B03
LH10-13B05
LH10-13B09
LH10-13B12
LH10-13B15
LH10-13B24
LH15-13B03
LH15-13B05
LH15-13B09
LH15-13B12
C2(uF)
330
330
120
120
68
68
470
330
120
120
120
68
680
680
470
220
TVS1
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
C1(uF)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Model
LH15-13B15
LH15-13B24
LH15-13B48
LH20-13B03
LH20-13B05
LH20-13B09
LH20-13B12
LH20-13B15
LH20-13B24
LH25-13B03
LH25-13B05
LH25-13B09
LH25-13B12
LH25-13B15
LH25-13B24
LH25-13B48
C2(uF)
220
68
33
330
330
220
220
220
220
330
330
330
330
330
120
68
TVS1
SMBJ20A
SMBJ30A
SMBJ64A
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
SMBJ64A
Note:
Output filtering capacitor C2 is electrolytic capacitor, it is recommended to apply electrolytic capacitor with high frequency and low resistance. For
capacitance and current of capacitor please refer to manufacture’s datasheet. Capacitance withstand voltage derating should be 80% or above. C1 is
ceramic capacitor, which is used to filter high-frequency noise. TVS is a recommended component to protect post-circuits if converter fails.
2. EMC solution-recommended circuit
Can u se M OR NSUN ' s FC-LX1 D
FUSE
LDM
LCM
AC( L)
AC( L)
+Vo
CY1
C1
C2
TVS1
RL
+
AC/DC
MOV1 CX
CY2
-Vo
AC( N)
AC(N)
Fig 2
2015.03.02-A/1
Page 4 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH(05-25)-13Bxx Series
EMC solution-recommended circuit PCB layout
Fig 3
Suggestions for safety regulation and wiring width: wire width≥3mm, distance between wires≥6mm, and distance between wire and
ground≥6mm
Element model
MOV1
Recommended value
S14K350
CY1 , CY2
1000pF/400VAC
CX
0.1μF/310VAC
Element model
FC-LX1D
FUSE
10mH, recommended to use MORNSUN’s
FL2D-Z5-103
4.7μH/2A
LCM
LDM
Recommended value
EMC filter
LH05
1A/300V slow fusing, necessary
LH10/15
2A/300V slow fusing, necessary
LH20/25
3.15A/300V slow fusing, necessary
--
--
3. Application of Trim and calculation of Trim resistance
+Vot
+Vot
R1
V ref
R2
RT
R1
R3
Trim
V ref
RT
R3
Trim
R2
0V
0V
Trim up
Trim down
Applied circuits of Trim (Part in broken line is the interior of models)
Calculation formula of Trim resistance:
up: R T =
aR 2
R 2 -a
-R 3
a=
Vref
R1
Vot-Vref
down : R T =
aR 1
R 1 -a
-R 3
a=
Vot-Vref
R2
Vref
RT is Trim resistance
a is a self-defined parameter, with
no real meaning.
Vout
R1(KΩ)
R2(KΩ)
R3(KΩ)
Vref(V)
3.3V
3.3
1.98
1
1.24
5V
3.3
3.3
1
2.5
9V
7.5
2.87
1
2.5
12V
3.83
1
1
2.5
15V
7.5
1.5
1
2.5
24V
8.66
1
1
2.5
48V
68
3.73
1
2.5
Vot(V)
Output voltage
after regulation,
variation ≤ ±10%
4. For more information about Mornsun EMC Filter products, please visit www.mornsun-power.com to
download the Selection Guide of EMC Filter
2015.03.02-A/1
Page 5 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH(05-25)-13Bxx Series
Dimensions and Recommended Layout
Pin Connection
Dimensions (Unit: mm)
Pin
LHxx-13Bxx
NO.
LH05
LH10
LH15
LH20
LH25
A
55.00
55.00
62.00
70.00
70.00
B
45.00
45.00
45.00
48.00
48.00
C
21.00
21.00
22.50
23.50
23.50
4
-Vo
D
40.50
47.00
54.00
62.00
62.00
5
No Pin
E
12.50
17.50
17.50
20.00
20.00
6
No Pin
7
No Pin
F
--
--
--
5.75
5.75
G
16.00
20.00
20.00
23.00
23.00
Models Weight
Weight
LH05
LH10
LH15
LH20
LH25
(Typ.)
75g
75g
85g
120g
120g
1
2
AC(N)
3
AC(L)
8
+Vo
Trim
Trim**
There is no pin “1”
on LH15-13Bxx
Trim**: only for LH20/25-13Bxx Series.
Note:
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com. Packing
bag number: 58220006;
2. If the product is not operated within the required load range, the product performance cannot be guaranteed to comply with all
parameters in the datasheet;
3. Unless otherwise specified, data in this datasheet should be tested under the conditions of Ta=25°C, humidity<75% when inputting
4.
5.
6.
7.
nominal voltage and outputting rated load;
All index testing methods in this datasheet are based on our Company’s corporate standards;
The performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model products
will exceed the above-mentioned requirements, and please directly contact our technician for specific information;
We can provide product customization service;
Specifications of this product are subject to changes without prior notice.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: [email protected]
2015.03.02-A/1
Page 6 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Similar pages