MACOM MAMUSS0007 Catv amplifier splitter module 50 - 860 mhz Datasheet

CATV Amplifier Splitter Module Preliminary
50 - 860 MHz
MAMUSS0007
MAMUSS0007
V1P
Features
•
•
•
•
•
•
Functional Schematic
Low Noise Figure
Low Distortion
Surface Mount Package
Multifunction Integration
Single Positive Supply
75 ohm Impedance
OUT3
OUT2
OUT1
Description
M/A-COM’s MAMUSS0007 is an
integrated module consisting of an
amplifier and two equal split power
dividers. The push-pull, low distortion,
amplifier includes the baluns and DC bias
circuitry. The device is ideally suited for
use in the CATV market where low noise
figure, low distortion and high linearity are
required.
Ordering Information
Part Number
Package
Vdd
IN
PIN Configuration
No.
PIN Name
Pin
Description
1
GND
Ground
2
GND
Ground
3
GND
Ground
MAMUSS0007
SMT Package
4
GND
Ground
MAMUSS0007SMB
Sample Test Board (Includes 5 Samples)
5
GND
Ground
6
GND
Ground
7
GND
Ground
8
GND
Ground
9
IN
RF Input
10
GND
Ground
11
VDD
+5V
12
GND
Ground
13
OUT 1
RF Output 1
14
GND
Ground
15
OUT 2
RF Output 2
16
GND
Ground
17
OUT 3
RF Output 3
18
GND
Ground
Absolute Maximum Ratings 1
Parameter
Absolute
Maximum
Input Power
+20 dBm
Operating Voltage
+10 volts
Operating Temperature
-40 oC to +85 oC
Storage Temperature
-65 oC to +150 oC
1. Exceeding any one or combination of these limits
may cause permanent damage.
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s)
or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
1
„ North America: Tel. (800) 366-2266
„ Asia/Pacific: Tel. +81-44-844-8296, Fax +81-44-844-8298
„ Europe: Tel. +44 (1908) 574 200, Fax +44 (1908) 574 300
CATV Amplifier Splitter Module, 50 - 860 MHz
MAMUSS0007
V1P
Electrical Specifications:
Parameter
TA = 25°C, Freq: 50 - 860 MHz, VDD = +5 Volts, Z0 = 75 ohms
Test Conditions
Units
Gain
IN-OUT1, IN-OUT2
dB
5
Gain
IN-OUT3
dB
8.5
IN-OUT1 vs IN-OUT2
dB
0.6
Gain Flatness
IN-OUT1/2
dB
1.6
Gain Flatness
IN-OUT 3
dB
1.0
Noise Figure
dB
dB
3.7
3.4
Return Loss
IN-OUT1, IN-OUT2
50 – 150 MHz
150 – 860 MHz
IN-OUT 3
50 – 150 MHz
150 – 860 MHz
IN
dB
dB
dB
3.4
3.0
15
Return Loss
OUT
dB
17
OUT-OUT
dB
24
135 channels, +13 dBmV/
channel at the input.
135 channels, +13 dBmV/
channel at the input
135 channels, +13 dBmV/
channel at the input.
VDD = + 5 Volts
dBc
-70
dBc
-73
dBc
-66
mA
200
Gain Unbalance
Noise Figure
Isolation
Composite Triple Beat, CTB
Composite Second Order, CSO
Cross modulation
IDD
Min.
Typ.
Max.
Static Sensitivity
Gallium Arsenide Integrated Circuits are
sensitive to electrostatic discharge (ESD) and
can be damaged by static electricity. Proper
ESD control techniques should be used when
handling these devices.
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s)
or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
2
„ North America: Tel. (800) 366-2266
„ Asia/Pacific: Tel. +81-44-844-8296, Fax +81-44-844-8298
„ Europe: Tel. +44 (1908) 574 200, Fax +44 (1908) 574 300
CATV Amplifier Splitter Module, 50 - 860 MHz
MAMUSS0007
V1P
Outline 2
2. All dimensions in mm.
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s)
or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
3
„ North America: Tel. (800) 366-2266
„ Asia/Pacific: Tel. +81-44-844-8296, Fax +81-44-844-8298
„ Europe: Tel. +44 (1908) 574 200, Fax +44 (1908) 574 300
CATV Amplifier Splitter Module, 50 - 860 MHz
MAMUSS0007
V1P
Typical Performance Curves
Noise Figure
In – Out 1
8.0
5.0
-40°C
+25°C
+85°C
7.0
In to Out 1
In to Out 2
In to Out 3
4.0
6.0
3.0
5.0
2.0
4.0
3.0
1.0
0
250
500
750
1000
0
200
Frequency (MHz)
400
600
800
1000
Frequency (MHz)
In – Out 2
Isolation
8.0
0.0
-40°C
+25°C
+85°C
7.0
Out 1 to Out 3
Out 1 to Out2
Out 2 to Out 3
-10.0
6.0
-20.0
5.0
-30.0
4.0
3.0
-40.0
0
200
400
600
800
1000
Frequency (MHz)
0
200
400
600
800
1000
Frequency (MHz)
In – Out 3
11.0
-40°C
+25°C
+85°C
10.0
9.0
8.0
7.0
6.0
0
200
400
600
800
1000
Frequency (MHz)
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s)
or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
4
„ North America: Tel. (800) 366-2266
„ Asia/Pacific: Tel. +81-44-844-8296, Fax +81-44-844-8298
„ Europe: Tel. +44 (1908) 574 200, Fax +44 (1908) 574 300
CATV Amplifier Splitter Module, 50 - 860 MHz
MAMUSS0007
V1P
Typical Performance Curves
Output Return Loss
Input Return Loss
0.0
0.0
-5.0
-5.0
-10.0
-10.0
-15.0
-15.0
-20.0
-20.0
-25.0
-25.0
-30.0
-30.0
-35.0
Out 1
Out 2
Out 3
-35.0
0
200
400
600
800
1000
Frequency (MHz)
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s)
or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
0
200
400
600
800
1000
Frequency (MHz)
5
„ North America: Tel. (800) 366-2266
„ Asia/Pacific: Tel. +81-44-844-8296, Fax +81-44-844-8298
„ Europe: Tel. +44 (1908) 574 200, Fax +44 (1908) 574 300
Similar pages