Click on Series name for product info on aimtec.com Series AME3-AZ 3Watt | AC-DC Converter FEATURES: • • • • • I/O Isolation 3000VAC Operating Temp: -40oCto +80oC Over load, Short Circuit Protection Input: 90-305VAC, 47-440Hz, or 130-430 VDC Optional 90-528VAC, 47-440Hz, or 130-745 VDC • RoHS compliant • Energy Star compliant • Ultra small package Models Single output Input Voltage (VAC/Hz) Input Voltage (VDC) AME3-3.3SAZ AME3-5SAZ AME3-12SAZ AME3-15SAZ AME3-24SAZ 90-305/47-440 90-305/47-440 90-305/47-440 90-305/47-440 90-305/47-440 130-430 130-430 130-430 130-430 130-430 -40 to -40 to -40 to -40 to -40 to AME3-3.3SBAZ AME3-5SBAZ AME3-12SBAZ AME3-15SBAZ AME3-24SBAZ 90-528/47-440 90-528/47-440 90-528/47-440 90-528/47-440 90-528/47-440 130-745 130-745 130-745 130-745 130-745 -40 to -40 to -40 to -40 to -40 to Model Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External fuse Input Dissipation (No Load) Output Specifications Parameters Voltage accuracy Line regulation Load regulation (single output) Transient Recovery Time Transient Response Deviation Minimum load Output Voltage (V) Output Current max (mA) Maximum capacitive Load (µF) +80 +80 +80 +80 +80 3.3 5 12 15 24 900 600 250 200 125 +80 +80 +80 +80 +80 3.3 5 12 15 24 700 600 250 200 125 Temperature range (ºC) Conditions Typical 115 VAC 230 VAC 277 VAC 480VAC 115 VAC 230 VAC 277 VAC 480 VAC Recommended slow blow type Conditions Efficiency Full load (%) 115 230 277 480 VAC VAC VAC VAC 2200 1100 680 560 470 63 67 75 78 81 64 67 73 74 81 62 65 70 71 80 2200 1100 680 560 470 61 67 72 72 71 61 67 72 71 71 60 66 70 70 69 Maximum Units 80 40 35 30 10 15 20 30 0.15 mA mA mA mA A A A A mA A W 1 ≦0.3 Typical Maximum ±5 ±3 ±5 200 25% load step ±2 0 3.3/5 VDC With 560µF E/C 200 Ripple & Noise 12/15 VDC With 220µF E/C 400 24 VDC With 220µF E/C 500 *Ripple & Noise measured at 20MHz bandwidth with 0.1µF and 115/230/277/480VAC (Typical input ) with Full Load Isolation Specifications Parameters Tested I/O voltage Isolation Resistance www.aimtec.com F 052e R8.J Full load (typical)* LL-HL, Full Load 0-100% load (typical)* Conditions Typical 60 sec >1000 Tel: +1 514 620 2722 1 of 3 54 60 61 61 62 Units % % % µs % of Vout % mV p-p mV p-p mV p-p Rated Units 3000 VAC MΩ Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME3-AZ 3Watt | AC-DC Converter General Specifications Parameters Conditions Switching frequency Over Load protection Short circuit protection Typical Auto recovery AME3-xxSBAZ derating at 50°C AME3-xxSAZ derating at 55°C Operating temperature Maximum 100 >125% Auto recovery KHz o -40 to +80 Storage temperature Maximum Case temperature Humidity Case material Weight Dimensions (L x W x H) Units C o -40 to +85 100 C C % RH o Non condensing 20~95 Plastic resin + Fiberglass (flammability to UL 94V-0) 25 g 1.40 x 0.92 x 0.76 (35.60 x 23.31 x 19.32mm) o > 400 000 hrs (MIL-HDBK -217F, t=+25 C)/Full Load MTBF > 100,000 hrs (MIL-HDBK -217F, t= at highest operating temperature)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Conditions Wave form: Half sine wave Acceleration amplitude: 5gn Shock Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Displacement: 1mm Vibrations Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals Standards cULus, CE, CB, FCC Information technology Equipment EMI - Conducted and radiated emission Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity (1KV) RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity IEC/EN/UL 60950-1:2006+A11:2009 EN55022, class B (* see note) IEC/EN 61000-3-2, Class A IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5(SAZ:Level2,SBAZ:Level 1) IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 FCC part 15 Subpart B, Class B, ANSI C63.4 :2003 * Note: for 528VAC models to meet the EN55022 class B spec an external 0.33uF X capacitor is needed to be installed between AC L and AC N as close as possible to the input of the power supply itself Pin Out Specifications* Pin Single 1* 2* 3 4 AC Input (N) or (L1) AC Input (L) or (L2) -V Output +V Output * Note: Input Pins 1 and 2 can be “N” and "L" respectively when the input voltage is supplied from a single phase. Input Pins 1 and 2 can be “L1” and "L2" respectively when the input voltage is supplied from 3 phase line to line voltage 208-480Vac (208 Y/ 120V 3-phase, 240 Y/ 120V 3-phase, 400 Y/ 230V 3-phase or 480 Y/ 277V 3-phase). www.aimtec.com F 052e R8.J Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME3-AZ 3Watt | AC-DC Converter Derating Derating at 50°C for AME3-xxSBAZ models Derating at 55°C for AME3-xxSAZ models Dimensions 17.80 (0.70) 35.60 (1.40) Top Vi ew 1 15.24 1 3 Top View (0.60) 7.60 (0.29) Temperaturem easuring point 11.655 3 (0.46) 23.31 4 4 (0.92) 2 2 28.00 DIV: 5.00(0.20) (1.10) Ø 10.0 ( Ø 0.40) Ø 0.60 ( Ø 0.02) 19.32 Side View (0.76) 6.00 (0.24) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter ±0.05 (±0.002) Pin Pitch Tolerance ±0.50 (±0.02) 0.60 (0.02) NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.J Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only