AIMTEC AME3-24SAZ Over load, short circuit protection Datasheet

Click on Series name for product info on aimtec.com
Series AME3-AZ
3Watt | AC-DC Converter
FEATURES:
•
•
•
•
•
I/O Isolation 3000VAC
Operating Temp: -40oCto +80oC
Over load, Short Circuit Protection
Input: 90-305VAC, 47-440Hz, or 130-430 VDC
Optional 90-528VAC, 47-440Hz, or 130-745 VDC
• RoHS compliant
• Energy Star compliant
• Ultra small package
Models
Single output
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
AME3-3.3SAZ
AME3-5SAZ
AME3-12SAZ
AME3-15SAZ
AME3-24SAZ
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
130-430
130-430
-40 to
-40 to
-40 to
-40 to
-40 to
AME3-3.3SBAZ
AME3-5SBAZ
AME3-12SBAZ
AME3-15SBAZ
AME3-24SBAZ
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
130-745
130-745
130-745
130-745
130-745
-40 to
-40 to
-40 to
-40 to
-40 to
Model
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input Dissipation (No Load)
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Transient Recovery Time
Transient Response Deviation
Minimum load
Output
Voltage
(V)
Output
Current max
(mA)
Maximum
capacitive
Load
(µF)
+80
+80
+80
+80
+80
3.3
5
12
15
24
900
600
250
200
125
+80
+80
+80
+80
+80
3.3
5
12
15
24
700
600
250
200
125
Temperature
range
(ºC)
Conditions
Typical
115 VAC
230 VAC
277 VAC
480VAC
115 VAC
230 VAC
277 VAC
480 VAC
Recommended slow blow type
Conditions
Efficiency
Full load (%)
115
230
277
480
VAC
VAC
VAC
VAC
2200
1100
680
560
470
63
67
75
78
81
64
67
73
74
81
62
65
70
71
80
2200
1100
680
560
470
61
67
72
72
71
61
67
72
71
71
60
66
70
70
69
Maximum
Units
80
40
35
30
10
15
20
30
0.15
mA
mA
mA
mA
A
A
A
A
mA
A
W
1
≦0.3
Typical
Maximum
±5
±3
±5
200
25% load step
±2
0
3.3/5 VDC With 560µF E/C
200
Ripple & Noise
12/15 VDC With 220µF E/C
400
24 VDC With 220µF E/C
500
*Ripple & Noise measured at 20MHz bandwidth with 0.1µF and 115/230/277/480VAC (Typical input ) with Full Load
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
www.aimtec.com
F 052e R8.J
Full load (typical)*
LL-HL, Full Load
0-100% load (typical)*
Conditions
Typical
60 sec
>1000
Tel: +1 514 620 2722
1 of 3
54
60
61
61
62
Units
%
%
%
µs
% of Vout
%
mV p-p
mV p-p
mV p-p
Rated
Units
3000
VAC
MΩ
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME3-AZ
3Watt | AC-DC Converter
General Specifications
Parameters
Conditions
Switching frequency
Over Load protection
Short circuit protection
Typical
Auto recovery
AME3-xxSBAZ derating at 50°C
AME3-xxSAZ derating at 55°C
Operating temperature
Maximum
100
>125%
Auto recovery
KHz
o
-40 to +80
Storage temperature
Maximum Case temperature
Humidity
Case material
Weight
Dimensions (L x W x H)
Units
C
o
-40 to +85
100
C
C
% RH
o
Non condensing
20~95
Plastic resin + Fiberglass (flammability to UL 94V-0)
25
g
1.40 x 0.92 x 0.76 (35.60 x 23.31 x 19.32mm)
o
> 400 000 hrs (MIL-HDBK -217F, t=+25 C)/Full Load
MTBF
> 100,000 hrs (MIL-HDBK -217F, t= at highest operating temperature)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Environment Approval
Parameters
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Shock
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Displacement: 1mm
Vibrations
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
Standards
cULus, CE, CB, FCC
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity (1KV)
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC/EN/UL 60950-1:2006+A11:2009
EN55022, class B (* see note)
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5(SAZ:Level2,SBAZ:Level 1)
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
FCC part 15 Subpart B, Class B, ANSI C63.4 :2003
* Note: for 528VAC models to meet the EN55022 class B spec an external 0.33uF X capacitor is needed to be installed between AC L and AC N as close
as possible to the input of the power supply itself
Pin Out Specifications*
Pin
Single
1*
2*
3
4
AC Input (N) or (L1)
AC Input (L) or (L2)
-V Output
+V Output
* Note: Input Pins 1 and 2 can be “N” and "L" respectively when the input voltage is supplied from a single phase.
Input Pins 1 and 2 can be “L1” and "L2" respectively when the input voltage is supplied from 3 phase line to line voltage 208-480Vac (208 Y/ 120V 3-phase,
240 Y/ 120V 3-phase, 400 Y/ 230V 3-phase or 480 Y/ 277V 3-phase).
www.aimtec.com
F 052e R8.J
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME3-AZ
3Watt | AC-DC Converter
Derating
Derating at 50°C for AME3-xxSBAZ models
Derating at 55°C for AME3-xxSAZ models
Dimensions
17.80
(0.70)
35.60
(1.40)
Top Vi ew
1
15.24
1
3
Top View
(0.60)
7.60
(0.29)
Temperaturem easuring point
11.655
3
(0.46)
23.31
4
4
(0.92)
2
2
28.00
DIV: 5.00(0.20)
(1.10)
Ø 10.0 ( Ø 0.40)
Ø 0.60 ( Ø 0.02)
19.32
Side View
(0.76)
6.00
(0.24)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter ±0.05 (±0.002)
Pin Pitch Tolerance ±0.50 (±0.02)
0.60
(0.02)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.J
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages