Click on Series name for product info on aimtec.com Series AM6TW-Z 6 Watt | DC-DC Converter FEATURES: RoHS compliant 24 Pin DIP Package Wide 4:1 input range High efficiency up to 85% Operating temperature -40oC to + 85oC Input / output isolation 1500 and 3500VDC Pin compatible with multiple manufacturers Continuous short circuit protection Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Max Capacitive Load(uF) Efficiency (%) AM6TW-2403SZ AM6TW-2405SZ AM6TW-2407SZ AM6TW-2409SZ AM6TW-2412SZ AM6TW-2415SZ AM6TW-2418SZ AM6TW-2424SZ AM6TW-4803SZ AM6TW-4805SZ AM6TW-4807SZ AM6TW-4809SZ AM6TW-4812SZ AM6TW-4815SZ AM6TW-4818SZ AM6TW-4824SZ 9-36 9-36 9-36 9-36 9-36 9-36 9-36 9-36 18-72 18-72 18-72 18-72 18-72 18-72 18-72 18-72 3.3 5 7.2 9 12 15 18 24 3.3 5 7.2 9 12 15 18 24 1400 1200 830 660 500 400 330 250 1400 1200 830 660 500 400 330 250 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1000 680 680 330 100 100 100 68 1000 680 680 330 100 100 100 68 75 81 78 82 83 83 83 82 75 81 81 82 82 85 83 83 AM6TW-2403SH35Z AM6TW-2405SH35Z AM6TW-2407SH35Z AM6TW-2409SH35Z AM6TW-2412SH35Z AM6TW-2415SH35Z AM6TW-2418SH35Z AM6TW-2424SH35Z AM6TW-4803SH35Z AM6TW-4805SH35Z AM6TW-4807SH35Z AM6TW-4809SH35Z AM6TW-4812SH35Z AM6TW-4815SH35Z AM6TW-4818SH35Z AM6TW-4824SH35Z 9-36 9-36 9-36 9-36 9-36 9-36 9-36 9-36 18-72 18-72 18-72 18-72 18-72 18-72 18-72 18-72 3.3 5 7.2 9 12 15 18 24 3.3 5 7.2 9 12 15 18 24 1400 1200 830 660 500 400 330 250 1400 1200 830 660 500 400 330 250 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 1000 680 680 330 100 100 100 68 1000 680 680 330 100 100 100 68 75 81 78 82 83 83 83 82 75 81 81 82 82 85 83 83 Isolation (VDC) Max Capacitive Load(uF) Efficiency (%) 1500 1500 1500 1500 1500 1500 1500 ±470 ±330 ±330 ±100 ±68 ±68 ±68 80 82 80 82 84 80 80 Models Dual output Model AM6TW-2403DZ AM6TW-2405DZ AM6TW-2407DZ AM6TW-2409DZ AM6TW-2412DZ AM6TW-2415DZ AM6TW-2418DZ www.aimtec.com F 051e R8.H Input Voltage (V) 9-36 9-36 9-36 9-36 9-36 9-36 9-36 Output Voltage (V) ±3.3 ±5 ±7.2 ±9 ±12 ±15 ±18 Output Current max (mA) ±700 ±600 ±410 ±330 ±250 ±200 ±160 Tel: +1 514 620 2722 1 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM6TW-Z 6 Watt | DC-DC Converter Models Dual output (continued) Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Max Capacitive Load(uF) Efficiency (%) AM6TW-2424DZ AM6TW-4803DZ AM6TW-4805DZ AM6TW-4807DZ AM6TW-4809DZ AM6TW-4812DZ AM6TW-4815DZ AM6TW-4818DZ AM6TW-4824DZ 9-36 18-72 18-72 18-72 18-72 18-72 18-72 18-72 18-72 ±24 ±3.3 ±5 ±7.2 ±9 ±12 ±15 ±18 ±24 ±125 ±700 ±600 ±410 ±330 ±250 ±200 ±160 ±125 1500 1500 1500 1500 1500 1500 1500 1500 1500 ±22 ±470 ±330 ±330 ±100 ±68 ±68 ±68 ±22 81 79 82 81 81 83 81 81 81 AM6TW-2403DH35Z AM6TW-2405DH35Z AM6TW-2407DH35Z AM6TW-2409DH35Z AM6TW-2412DH35Z AM6TW-2415DH35Z AM6TW-2418DH35Z AM6TW-2424DH35Z AM6TW-4803DH35Z AM6TW-4805DH35Z AM6TW-4807DH35Z AM6TW-4809DH35Z AM6TW-4812DH35Z AM6TW-4815DH35Z AM6TW-4818DH35Z AM6TW-4824DH35Z 9-36 9-36 9-36 9-36 9-36 9-36 9-36 9-36 18-72 18-72 18-72 18-72 18-72 18-72 18-72 18-72 ±3.3 ±5 ±7.2 ±9 ±12 ±15 ±18 ±24 ±3.3 ±5 ±7.2 ±9 ±12 ±15 ±18 ±24 ±700 ±600 ±410 ±330 ±250 ±200 ±160 ±125 ±700 ±600 ±410 ±330 ±250 ±200 ±160 ±125 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 ±470 ±330 ±330 ±100 ±68 ±68 ±68 ±22 ±470 ±330 ±330 ±100 ±68 ±68 ±68 ±22 80 82 80 82 84 80 80 81 79 82 81 81 83 81 81 81 Input Specifications Parameters Voltage range Filter Turn on Transient process time Start up time Absolute Maximum Rating Nominal Typical 24 48 9-36 18-72 Maximum Units VDC (Pi) Network 24 Vin 48 Vin Peak Input Voltage time 350 500 -0.7-40 -0.7-80 100 ms ms VDC ms Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Conditions Typical 3 sec Rated Units 1500 or 3500 VDC MOhm pF Maximum Units > 1000 470 Output Specifications Parameters Voltage accuracy Voltage balance Short Circuit protection Short circuit restart Over current protection Line voltage regulation (Single) Line voltage regulation (Dual) www.aimtec.com F 051e R8.H Conditions Typical Dual Output ±1 ±1 Continuous Auto-recovery 120% Iout ±0.5 ±0.5 Tel: +1 514 620 2722 2 of 5 % % % % Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM6TW-Z 6 Watt | DC-DC Converter Output Specifications (continued) Parameters Load voltage regulation (Single) Load voltage regulation (Single) 3,3V output model Load voltage regulation (Dual) Load voltage regulation (Dual) ±3.3V output model Temperature coefficient Ripple & Noise Rising time Conditions Typical 0 – 100% load 0 – 100% load ±0.5 ±1.5 Maximum Units % % 0 – 100% load 0 – 100% load ±0.5 ±1.5 % % At 20MHz Bandwidth ±0.02 60 10 %/oC mV p-p ms General Specifications Parameters Switching frequency Operating temperature Storage temperature Max Case temperature Derating Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Conditions Typical 100% load Full Load without Derating Maximum 260 -40 to +85 -40 to +125 +100 Units KHz o C o C o C Not-Required Free air convection 90 % Nickel coated copper 26 g Tolerance ±0.5 mm or ±0.02 inches 1.28 x 0.84 x 0.41 inches 32.25 x 21.35 x 10.50 mm >960 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified Safety Specifications Parameters Agency Approval Standards www.aimtec.com F 051e R8.H CE EN55022 Class A, EN55024 IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria B (external 220uF/100V cap required) IEC61000-4-5, Perf. Criteria B (external 220uF/100V cap required) IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A NOTE: Also designed to meet IEC60950-1:2001 Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM6TW-Z 6 Watt | DC-DC Converter Pin Out Specifications Pin 1 2 3 9 10 11 12/13 14 15 16 22 23 24 1500VDC Single Dual +V Input N. C. N. C. Omitted -V Output +V Output -V Input +V Output -V Output Omitted N. C. N. C. +V Input +V Input -V Output Common Omitted Common +V Output -V Input +V Output Common Omitted Common -V Output +V Input 3500VDC Single Dual Omitted -V Input -V Input Omitted Omitted N.C. Omitted +V Output Omitted -V Output +V Input +V Input Omitted Omitted -V Input -V Input Common Omitted -V Output Omitted +V Output Omitted Common +V Input +V Input Omitted Dimensions www.aimtec.com F 051e R8.H Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM6TW-Z 6 Watt | DC-DC Converter Conducted Emissions: Dual Output 12uH L +V output +V input C1 DC/DC Converter 220uF 100V Load -V output -V input Load Common C2 1000pF 2KV Surge: Dual Output +V output +V input Load DC/DC Converter C1 -V output 220uF 100V Load -V input Common NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R8.H Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only