NEC NDL7408P1KC 1 310 nm ingaasp strained mqw dc-pbh laser diode coaxial module with single mode fiber Datasheet

DATA SHEET
LASER DIODE
NDL7408P Series
1 310 nm InGaAsP STRAINED MQW DC-PBH LASER DIODE
COAXIAL MODULE WITH SINGLE MODE FIBER
DESCRIPTION
NDL7408P Series is a 1 310 nm laser diode coaxial module with single mode fiber. It has a strained Multiple
Quantum Well (st-MQW) structure and a built-in InGaAs monitor photo diode. It is recommended for junction or
access network systems. The series is available in two types of output power: 1.0 mW and 0.2 mW.
FEATURES
• Center wavelength
λC = 1 310 nm
• Two types of output power : 1.0 mW (NDL7408PK Series)
0.2 mW (NDL7408PL Series)
• Low threshold current
lth = 12 mA TYP. @TC = 25 °C
• High cut-off frequency
f C = 2.0 GHz
• InGaAs monitor PIN-PD
• Wide operating temperature range: −40 to +85 °C
• Based on Bellcore TA-NWT-000983
The information in this document is subject to change without notice.
Document No. P10532EJ3V0DS00 (3rd edition)
Date Published June 1996 P
Printed in Japan
The mark • shows major revised points.
©
1994
NDL7408P Series
PACKAGE DIMENSIONS (in millimeters)
NDL7408P1
NDL7408P
Optical Fiber
SM-9/125
Length: 1 m
φ 0.9
φ 3.2±0.25
φ 0.9
φ 3.2±0.25
φ 7±0.2
25.3±1.0
20±1.0
20±1.0
4.1±0.8
5.3±0.8
2.0±0.2
5
2– φ 2.2
5
15
25.3±1.0
15
φ 7±0.2
4.0±0.2
Optical Fiber
SM-9/125
Length: 1 m
φ 0.45±0.05
φ 0.45±0.05
φ 6±1.0
12.7±0.2
17.0±0.2
φ 6±0.1
PD
4
φ 7±0.2
4 3
1 2
P.C.D. = φ 2
3
1
2
4 3
1 2
LD
CASE
NDL7408P2
φ 0.9
12.6±0.2
5
15
25.6±1.0
φ 7±0.2
CASE
Optical Fiber
SM-9/125
Length: 1 m
21.0±1.0
3
4
12±0.15
16.0
1.27±0.2
2.54±0.3
PIN CONNECTIONS
2
PD
3
4
LD
4–0.5
PIN 1, 4, 5, 8
3
1
CASE
2
1
7±0.2
2
2.54±0.3
3.6±0.5
4–φ 0.45±0.05
5.1±0.2
10.2±0.2
5.1±0.1
φ 7±0.2
0.2
0.3
2.5±1.0
19.5±1.0
0.3
P.C.D. = φ 2
2– φ 2.5
6
4
3
2
1
5
6
7
8
4– φ 0.45
PIN 2, 3, 6, 7
2
LD
12.6±0.2
3.81
±0.3
φ1
2
1
6.3±0.2
φ 3.2±0.25
3
4
NDL7408P4
12.6±0.2
Optical Fiber
SM-9/125
Length: 1 m
1.0±0.1
3.7±0.3
7.2±0.3
PD
P.C.D. = φ 2
0.5±0.2
•
Pin No.
1
2
3
4
5
6
7
8
Function
NC
PD anode
PD cathode
NC
NC
LD cathode
LD anode
NC
NDL7408P Series
•
ORDERING INFORMATION
NDL7408
P : No Flange
P1 : Flat Mount Flange
P2 : Vertical Mount Flange
K : 1.0 mW
L : 0.2 mW
No suffix : Without Connector
Part Number
NDL7408PK
Ranks
M
NDL7408PKC
M
Without Connector
No Flange
With FC-PC Connector
1.0 mW
Without Connector
Flat Mount Flange
With FC-PC Connector
With SC-PC Connector
M
NDL7408P2KC
1.0 mW
Without Connector
Vertical Flange
With FC-PC Connector
NDL7408P2KD
With SC-PC Connector
M
NDL7408P4KC
1.0 mW
Without Connector
8-pin DIP
With FC-PC Connector
NDL7408P4KD
NDL7408PL
With SC-PC Connector
N
NDL7408PLC
0.2 mW
Without Connector
No Flange
With FC-PC Connector
NDL7408PLD
NDL7408P1L
With SC-PC Connector
N
NDL7408P1LC
0.2 mW
Without Connector
Flat Mount Flange
With FC-PC Connector
NDL7408P1LD
NDL7408P2L
With SC-PC Connector
N
NDL7408P2LC
0.2 mW
Without Connector
Vertical Flange
With FC-PC Connector
NDL7408P2LD
NDL7408P4L
NDL7408P4LC
NDL7408P4LD
: With SC-PC Connector
1.0 mW
NDL7408P1KD
NDL7408P4K
D
With SC-PC Connector
NDL7408P1KC
NDL7408P2K
: With FC-PC Connector
Description
NDL7408PKD
NDL7408P1K
C
With SC-PC Connector
N
0.2 mW
Without Connector
8-pin DIP
With FC-PC Connector
With SC-PC Connector
3
NDL7408P Series
ABSOLUTE MAXIMUM RATINGS (TC = 25 °C, unless otherwise specified)
Parameter
Symbol
Ratings
Unit
Forward Current of LD
IF
Ith + 50
mA
Reverse Voltage of LD
VR
2.0
V
Forward Current of PD
IF
10
mA
Reverse Voltage of PD
VR
20
V
Operating Case Temperature
TC
−40 to +85
°C
Storage Temperature
Tstg
−40 to +85
°C
Lead Soldering Temperature (10 s)
Tsld
260
°C
ELECTRO-OPTICAL CHARACTERISTICS (TC = 25 °C, unless otherwise specified)
Parameter
Symbol
Operating Voltage
Vop
Threshold Current
Ith
Modulation Current
Imod
Conditions
MIN.
TYP.
MAX.
Unit
1.1
1.3
V
10
25
mA
TC = +85 °C
25
50
Pf = 1.0 mW @NDL7408PK Series
15
30
*1
mA
Pf = 0.2 mW @NDL7408PL Series
Differential Efficiency from Fiber
for NDL7408PK Series
Differential Efficiency from Fiber
for NDL7408PL Series
Center Emission Wavelength
Temperature Dependence of
Center Emission Wavelength
Spectral Width
ηd
0.025
0.050
0.018
0.035
0.010
0.015
TC = +85 °C
0.005
0.010
*1, RMS (−20 dB)
1 290
1 310
TC = −40 to +85 °C
1 260
TC = +85 °C
ηd
λC
1 330
nm
1 360
∆λ/∆T
TC = −40 to +85 °C
0.4
0.5
nm/°C
σ
*1, RMS (−20 dB)
1.3
2.5
nm
TC = +85 °C
1.5
4
Cut-off Frequency
fC
−3 dB
2.0
Rise Time
tr
10 to 90 %
0.2
0.5
ns
Fall Time
tf
90 to 10 %
0.3
0.5
ns
Monitor Current of PD
Im
VRD = 5 V, *1
Dark Current of PD
ID
VRD = 5 V
0.1
10
nA
Tracking Error
γ
Im = const., TC = −40 to +85 °C
0.5
1.0
dB
*2
*1 Pf = 1.0 mW @NDL7408PK Series
Pf = 0.2 mW @NDL7408PL Series
Pf
*2 γ = 10 log
XmW
100
TC = 25 ˚C
TC = –40 to +85 ˚C
Pf
0
Im
(@ Pf (25 ˚C)= X mW)
X = 1.0 mW @NDL7408PK Series
X = 0.2 mW @NDL7408PL Series
GHz
µA
700
Pf
XmW
X
4
W/A
Im
NDL7408P Series
TYPICAL CHARACTERISTICS (TC = −40 to +85 °C)
OUTPUT POWER FROM FIBER
vs. FORWARD CURRENT FOR
NDL7408PL SERIES
1.5
TC = –40 ˚C
TC = +25 ˚C
0.4
TC = +70 ˚C
TC = +85 ˚C
0.3
0.2
0.1
0
50
100
TC = +25 ˚C
0.5
50
0
100
150
Forward Current IF (mA)
THRESHOLD CURRENT AND OPERATION
CURRENT vs. CASE TEMPERATURE
TEMPERATURE DEPENDENCE OF CENTER
WAVELENGTH FOR NDL7408P SERIES
1 360
50
Center Wavelength λC (nm)
Iop (@ Pf = 0.2/1.0 mW)
30
Ith
20
10
5
3
2
0
20
40
60
80
100
1 340
1 320
1 300
1 280
1 260
–60 –40
–20
0
20
40
60
80
100
Case Temperature TC (˚C)
Case Temperature TC (˚C)
TEMPERATURE DEPENDENCE OF
DIFFERENTIAL EFFICIENCY FROM FIBER
FOR NDL7408PL SERIES
TEMPERATURE DEPENDENCE OF
DIFFERENTIAL EFFICIENCY FROM FIBER
FOR NDL7408PK SERIES
0.10
Differential Efficiency from Fiber for
NDL7408PK Series η d (W/A)
0.03
Differential Efficiency from Fiber for
NDL7408PL Series η d (W/A)
TC = +85 ˚C
Forward Current IF (mA)
1
–60 –40 –20
0.02
0.01
0
–60 –40 –20
0
20
40
60
Case Temperature TC (˚C)
6
TC = +70 ˚C
1.0
150
100
Threshold Current Ith (mA)
Operation Current Iop (mA)
TC = –40 ˚C
Output Power from Fiber for
NDL7408PK Series Pf (mW)
Output Power from Fiber for
NDL7408PL Series Pf (mW)
0.5
OUTPUT POWER FROM FIBER
vs. FORWARD CURRENT FOR
NDL7408PK SERIES
80
100
0.08
0.06
0.04
0.02
0
–60 –40 –20
0
20
40
60
Case Temperature TC (˚C)
80
100
NDL7408P Series
TYPICAL CHARACTERISTICS (TC = 25 °C)
LONGITUDINAL MODE FROM FIBER
FOR NDL7408P SERIES
OUTPUT POWER FROM FIBER vs.
LD MONITOR CURRENT
Relative Intensity
Output Power from Fiber Pf (mW)
1.5
1 300
1 310
1 320
NDL7408PK Series
1
0.5
NDL7408PL Series
0
1.0
0.5
Wavelength λ (nm)
1.5
LD Monitor Current Im (mA)
FORWARD CURRENT vs.
FORWARD VOLTAGE FOR
NDL7408P SERIES
FREQUENCY RESPONSE (Pf = 0.2 / 1.0 (mW))
50
9
Relative Intensity (dB)
Forward Current IF (mA)
6
40
30
20
10
3
0
–3
–6
–9
–12
0
1
Forward Voltage VF (V)
2
0
1
2
3
4
5
Modulation Frequency f (GHz)
7
NDL7408P Series
1.3 µm FABRY-PEROT DC-PBH LASER DIODE FAMILY
Features
Part Number
Remarks
Package
φ5.6 mm Small Can
NDL7001
With monitor photo diode
φ5.6 mm Small Can with Lens
NDL7001L
With monitor photo diode
4-pin Coaxial Module with SMF
NDL7401P Series
NDL7408P Series
Without TEC
With monitor photo diode
REFERENCE
Document Name
8
Document No.
NEC semiconductor device reliability/quality control system
LEI-1201
Quality grades on NEC semiconductor devices
IEI-1209
Semiconductor device mounting technology manual
C10535E
Guide to quality assurance for semiconductor devices
MEI-1202
Semiconductor selection guide
X10679E
NDL7408P Series
CAUTION
Within this device there exists GaAs (Gallium Arsenide) material which is a harmful
substance if ingested. Please do not under any circumstances break the hermetic seal.
SEMICONDUCTOR LASER
INVISIBLE LASER RADIATION
AVOID DIRECT EXPOSURE TO BEAM
OUTPUT POWER
mw MAX
WAVELENGTH
nm
CLASS IIIb LASER PRODUCT
AVOID EXPOSURE-Invisible
Laser Radiation is emitted from
this aperture
NEC Building, 7-1, Shiba 5-chome,
Minato-ku, Tokyo 108-01, Japan
Type number:
Manufactured:
Serial number:
This product conforms to FDA
regulations as applicable
to standards 21 CFR Chapter 1,
Subchapter J.
The export of this product from Japan is prohibited without governmental license. To export or re-export this product from
a country other than Japan may also be prohibited without a license from that country. Please call an NEC sales
representative.
No part of this document may be copied or reproduced in any form or by any means without the prior written
consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which may appear in this
document.
NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual
property rights of third parties by or arising from use of a device described herein or any other liability arising
from use of such device. No license, either express, implied or otherwise, is granted under any patents,
copyrights or other intellectual property rights of NEC Corporation or others.
While NEC Corporation has been making continuous effort to enhance the reliability of its semiconductor devices,
the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or
property arising from a defect in an NEC semiconductor device, customer must incorporate sufficient safety
measures in its design, such as redundancy, fire-containment, and anti-failure features.
NEC devices are classified into the following three quality grades:
"Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on
a customer designated "quality assurance program" for a specific application. The recommended applications
of a device depend on its quality grade, as indicated below. Customers must check the quality grade of each
device before using it in a particular application.
Standard: Computers, office equipment, communications equipment, test and measurement equipment,
audio and visual equipment, home electronic appliances, machine tools, personal electronic
equipment and industrial robots
Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster
systems, anti-crime systems, safety equipment and medical equipment (not specifically designed
for life support)
Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life
support systems or medical equipment for life support, etc.
The quality grade of NEC devices in "Standard" unless otherwise specified in NEC's Data Sheets or Data Books.
If customers intend to use NEC devices for applications other than those specified for Standard quality grade,
they should contact NEC Sales Representative in advance.
Anti-radioactive design is not implemented in this product.
M4 94. 11