Specification for an Highpass LC Filter MtronPTI P/N: LF9412 I. General & Electrical Requirements 1. Corner Frequency (FON): 1215MHz 2. Passband: 1215MHz to 1400MHz 3. Passband Insertion Loss: ≤ 0.7dB 4. Passband VSWR: ≤ 1.4:1 5. Passband Phase Linearity: ≤ 9 6. Rejection (Minimum, Relative to Insertion Loss) 35dB: 960MHz to 1100MHz 7. Signal Level: ≤ -16dBm CW, ≤ +51dBm 2msec pulsed 40% duty cycle 8. ZS/ZL: 50Ω nominal Note: The filter shall meet all performance requirements over the full operating temperature range (-40C to +85C) II. Environmental & Physical Requirements: 1. Temperature Range Operating: -40C to +85C Non-Operating: -55C to +125C 2. Altitude: Operating: Sea Level to 10,000-ft Non-Operating: Sea Level to 40,000-ft 3. Humidity: 0 to 100% Relative Humidity 4. Salt Atmosphere: Per MIL-STD-810F, Method 521.2 5. Vibration: Per MIL-STD-810F, Method 514.5, Category 4, 6, 11, 17, 18 & 21, Procedure I, II & IV 6. Shock: Per MIL-STD-810F, Method 516.5, Procedure I (Functional) & VII (Rail) 7. Temperature Cycling: Per MIL-STD-883, Method 1010.8, Test Condition B 8. Materials and Finish: Non-nutrient to fungus and non-corrosive in the specified application environment 9. Package (see Figure 1): Figure 1 –Filter Package Outline Drawing Rev. - 09/06/12 Page 1 of 2 The information contained herein is proprietary to MtronPTI and is submitted in confidence. This information may not be copied or divulged without the express written permission of MtronPTI Specification for an Highpass LC Filter MtronPTI P/N: LF9412 Rev. - 09/06/12 Page 2 of 2 The information contained herein is proprietary to MtronPTI and is submitted in confidence. This information may not be copied or divulged without the express written permission of MtronPTI