MBR2040CTD~MBR20200CTD 20 AMPERES SCHOTTKY BARRIER RECTIFIERS VOLTAGE 40 to 200 Volts CURRENT 20 Amperes FEATURES TO-220AB • Plastic package has Underwriters Laboratory Flammability Classification 94V-0. Flame Retardant Epoxy Molding Compound. • Metal silicon junction, majority carrier conduction • Low power loss, high efficiency. • High current capability • For use in low voltage, high frequency inverters free wheeling, and polarlity protection applications. • Lead free in comply with EU RoHS MECHANICAL DATA • Case: TO-220AB molded plastic • Terminals: Solder plated, solderable per MIL-STD-750, Method 2026 • Polarity: As marked. • Mounting Position: Any MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20% PARAMETER Maximum Recurrent P e a k Reverse V o l t a g S YMB OL V RRM Maximum RMS Voltage V Maximum DC B locking Voltage V Maximum Average Forward Current (See fi g.1 ) I Peak Forward Surge Current :8 .3 ms s i ngle half s i ne- wa ve superimposed on rated l oad(JED EC t h d) Maximum Forward Voltage at 10 A, per leg I RMS DC MBR 2040CTD MBR 2045CTD MBR 2050CTD MBR 2060CTD MBR 2080CTD UNITS 60 80 90 100 150 200 V 28 31.5 35 42 56 63 70 105 140 V 40 45 50 60 80 90 100 150 200 V FSM 0 .7 20 A 150A A 0.85 0.8 0.05 20 Typical Thermal Resistance R 2 Apr,2015-REV.02 MBR 20200CTD 50 IR 0.92 V mA O θJ C T ,T J MBR 20150CTD 45 Maximum DC Reverse Current TJ =25 OC at Rated DC B locking Voltage TJ=125 OC Operating Junction and Storage Temperature Range MBR 20100CTD 40 F ( A V) VF MBR 2090CTD S TG -50 to + 150 www.dyelec.com -55 to +175 C/ W O C PAGE . 1 MBR2040CTD~MBR20200CTD 20.0 = 40 - 100V =150 - 200V 16.0 12.0 8.0 RESISTIVE OR INDUCTIVE LOAD 4.0 0 0 20 40 60 80 100 120 140 160 180 PEAK FORWARD SURGE CURRENT, Amps AVERAGE FORWARD RECTIFIED CURRENT AMPERES RATING AND CHARACTERISTIC CURVES LEAD TEMPERATURE, C O 240 210 8.3m s S i n g l e Half Since-Wave JEDEC M e th o d 180 150 120 90 60 30 0 1 2 5 10 20 50 100 NO. OF CYCLE AT 60Hz Fig.1- FORWARD CURRENT DERATING CURVE Fig.2- MAXIMUM NON - REPETITIVE SURGE CURRENT 40 40-45V FORWARD CURRENT, Amps INSTANTANEOUS REVERSE CURRENT, mA 10 O T J =100 C 1.0 T J = 75 O C 0.1 T J = 25 C O 0.01 0.001 50-60V 80-100V 2 20 40 60 80 100 120 140 150-200V 1.0 0.8 0.6 0.4 TJ = 25OC Pulse Width = 300 us 1% Duty Cycle 0.2 0.1 0 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 FORWARD VOLTAGE, VOLTS PERCENT OF INSTANTANEOUS REVERSE VOLTAGE,(%) Fig.3- TYPICAL REVERSE CHARACTERISTICS Apr,2015-REV.02 10 8 6 4 www.dyelec.com Fig.4- TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS PAGE . 2 MBR2040CTD~MBR20200CTD Important Notice and Disclaimer •Reproducing and modifying information of the document is prohibited without permission from DIYI. •DIYI reserves the right to make changes to this document and its products and specifications at any time without notice. Customers should obtain and confirm the latest product information and specifications before final design, purchase or use. •DIYI disclaims any and all liability arising out of the application or use of any product including damages incidentally and consequentially occurred. •DIYI does not assume any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. •Applications shown on the herein document are examples of standard use and operation. Customers are responsible in comprehending the suitable use in particular applications. DIYI makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. •The products shown herein are not designed and authorized for equipments requiring high level of reliability or relating to human life and for any applications concerning life-saving or life-sustaining, such as medical instruments, transportation equipment, aerospace machinery et cetera. Customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify DIYI for any damages resulting from such improper use or sale. •Since DIYI uses lot number as the tracking base, please provide the lot number for tracking when complaining. Apr,2015-REV.02 www.dyelec.com PAGE . 3