Mean Well APV-16-24 16w single output switching power supply Datasheet

A P V- 1 6
16W Single Output Switching Power Supply
series
Features :
Constant voltage design
Universal AC input / Full range
Protections: Short circuit / Over current / Over voltage
Fully isolated plastic case
Cooling by free air convection
Small and compact size
Pass LPS
Suitable for LED lighting and moving sign applications
100% full load burn-in test
Low cost, high reliability
2 years warranty
F
SPECIFICATION
MODEL
OUTPUT
APV-16-5
APV-16-12
APV-16-15
5V
12V
15V
24V
RATED CURRENT
2.6A
1.25A
1A
0.67A
CURRENT RANGE
0 ~ 2.6A
0 ~ 1.25A
0 ~ 1A
0 ~ 0.67A
RATED POWER
13W
15W
15W
16.08W
120mVp-p
120mVp-p
150mVp-p
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE TOLERANCE Note.3
5.0%
LINE REGULATION
1.0%
SETUP, RISE TIME
VOLTAGE RANGE
20ms/230VAC
Note.4 90 ~ 264VAC
76%
80%
AC CURRENT
INRUSH CURRENT(max.)
0.3A/230VAC 0.5A/115VAC
COLD START 35A/115VAC
70A/230VAC
LEAKAGE CURRENT
0.25mA / 240VAC
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
NOTE
127 ~ 370VDC
EFFICIENCY (Typ.)
PROTECTION
OTHERS
1500ms,30ms / 115VAC at full load
47 ~ 63Hz
81%
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16V
17.5 ~ 21V
27.6 ~ 32.4V
Protection type : Shut off o/p voltage, clamping by zener diode
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
VIBRATION
SAFETY STANDARDS
Design refer to TUV EN60950-1, EN61347-2-13,UL8750
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015,EN61000-3-2 Class A,EN61000-3-3
ISOLATION RESISTANCE
EMC EMISSION
83%
Above 105% rated output power
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
EMC IMMUNITY
MTBF
APV-16-24
12ms/115VAC at full load
FREQUENCY RANGE
OVER CURRENT
EMC
LPS
2.0%
Note.6 1500ms, 30ms / 230VAC
HOLD UP TIME (Typ.)
SAFETY &
SELV
DC VOLTAGE
LOAD REGULATION
INPUT
110
Compliance to EN61547,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A
DIMENSION
1145.7K hrs min. MIL-HDBK-217F (25 )
77*40*29mm (L*W*H)
PACKING
0.1Kg; 120pcs/14Kg/0.93CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:APV-16-SPEC 2011-07-09
A P V- 1 6
16W Single Output Switching Power Supply
Mechanical Specification
series
Unit:mm
90
82.5
77
150 10
UL1569 18AWG
AC/N(Blue)
AC/L(Brown)
15.5
40
19
+V(Red)
-V(Black)
31
UL1569 20AWG
T case
150 10
29
T case: Max. Case Temperature
Block Diagram
I/P
fosc : 67KHz
EMI FILTER
POWER
SWITCHING
RECTIFIERS
RECTIFIERS
&
FILTER
+V
-V
DETECTION
CIRCUIT
PWM
CONTROL
Derating Curve
Static Characteristics
100
100
90
80
80
70
50
LOAD (%)
LOAD (%)
60
40
20
-30
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
100
200
210
220
230
240
250
264
INPUT VOLTAGE (VAC) 60Hz
File Name:APV-16-SPEC 2011-07-09