MPD MHI212D-15GRI8 Compact, 2w minidip ultra-high isolation dc/dc converter Datasheet

MHI200GRI8 Series
Compact, 2W MiniDIP
Ultra-High Isolation
DC/DC Converters
Electrical Specifications
Key Features:
• 2W Output Power
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
• 15 kV/µS CMTI
• EN 60950 Approved (Pend.)
• Reinforced Insulation
Typ.
Max.
5 VDC Input
4.5
5.0
5.5
12 VDC Input
10.8
12.0
13.2
24 VDC Input
21.6
24.0
26.4
• 8.0 kV Isolation
Input Voltage Range
Min.
Input Filter
Units
VDC
Capacitor Filter
Output
• Compact MiniDIP Case
Parameter
• -25°C to +80°C Operation
Output Voltage Accuracy
Conditions
• Industry Standard Pin-Out Output Voltage Balance
Line Regulation
Load Regulation, See Note 2
Min.
Typ.
Max.
Units
±2.0
±4.0
%
Dual Output, Balanced Loads
±0.1
±1.0
%
VIN = Min to Max
±1.2
±1.5
%
150
mV P - P
±0.02
%/°C
See Model Selection Guide
Ripple & Noise (20 MHz)
See Note 3
Temperature Coefficient
±0.01
Output Short Circuit
Momentary (0.5S Max)
General
Parameter
Conditions
Isolation Voltage
Min.
Typ.
Max.
Units
Rated For 60 Sec
4,000
VAC rms
Tested For 1 Sec
8,000
VDC
Isolation Resistance
500 VDC
Isolation Capacitance
10
100 kHz, 1V
G
15
20
pF
Common Mode Transient Immunity
15
kV/µS
Switching Frequency
50
80
100
kHz
Min.
Typ.
Max.
Units
-25
+25
+80
Environmental
Parameter
Conditions
Ambient
Operating Temperature Range
Case
Storage Temperature Range
+105
-50
Cooling
°C
+125
°C
95
%
Free Air Convection
Humidity
RH, Non-condensing
Physical
Case Size
See Mechanical Diagram (Page 2)
Case Material
Non-Conductive Black Plastic (UL94-V0)
MicroPower Direct
Weight
292 Page Street
Suite D
Stoughton, MA 02072
USA
0.17 Oz (5.1g)
Reliability Specifications
Parameter
Conditions
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
Safety Standards
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Min.
Typ.
Max.
2.0
Units
MHours
UL 60950, EN 60950 (Pending)
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (0.1 Sec)
Lead Temperature
Min.
Typ.
Max.
5 VDC Input
9.0
12 VDC Input
18.0
24 VDC Input
30.0
1.5 mm From Case for 10 Sec
260
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Model
Number
MHI205S-05GRI8
MHI205S-12GRI8
MHI205S-15GRI8
MHI205D-12GRI8
MHI205D-15GRI8
MHI212S-05GRI8
MHI212S-12GRI8
MHI212S-15GRI8
MHI212D-12GRI8
MHI212D-15GRI8
MHI224S-05GRI8
MHI224S-12GRI8
MHI224S-15GRI8
MHI224D-12GRI8
MHI224D-15GRI8
Input
Output
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
5
4.5 - 5.5
615
60
5
4.5 - 5.5
609
60
5
4.5 - 5.5
605
60
5
4.5 - 5.5
553
60
5
4.5 - 5.5
542
60
12
10.8 - 13.2
256
30
12
10.8 - 13.2
254
30
12
10.8 - 13.2
252
30
12
10.8 - 13.2
224
30
12
10.8 - 13.2
220
30
24
21.6 - 26.4
128
15
24
21.6 - 26.4
127
15
24
21.6 - 26.4
126
15
24
21.6 - 26.4
112
15
24
21.6 - 26.4
110
15
Voltage
Current
Current
(VDC)
(mA, Max)
(mA, Min)
5.0
12.0
15.0
±12.0
±15.0
5.0
12.0
15.0
±12.0
±15.0
5.0
12.0
15.0
±12.0
±15.0
Notes:
1. The specified maximum capacitive load is for each output.
2. Load regulation is measured over a range of 20% IOUT to 100% IOUT.
3. When measuring output ripple & noise, it is recommended that an external capacitor (3.3 µF typ.) be placed from
the +VOUT to the -VOUT pins for single output units and from each output to common for dual output models.
4. The converter should be connected to a low ac-impedance source. A source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and
input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (<1.0⍀ at 100 kHz) capacitor be mounted close to the converter. For 5V input units a 2.2 µF is recommended; for 12V input units, a 1.0 µF; and for 24V units a 0.47 µF.
5. Operation at no-load will not damage the unit, but they may not meet all specifications.
6. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection
tables for the correct rating.
400
165
133
±83
±66
400
165
133
±83
±66
400
165
133
±83
±66
Fuse
Capacitive
Load
Rating
Efficiency Regulation
Load
(%, Typ)
Slow-Blow
(%, Max)
(µF, Max)
8.0
3.0
2.5
±1.5
±1.0
8.0
3.0
2.5
±1.5
±1.0
8.0
3.0
2.5
±1.5
±1.0
(mA)
65
65
66
72
73
65
65
66
74
75
65
65
66
74
75
±12.0
±10.0
±10.0
±10.0
±10.0
±12.0
±10.0
±10.0
±10.0
±10.0
±12.0
±10.0
±10.0
±10.0
±10.0
330
330
330
100
100
330
330
330
100
100
330
330
330
100
100
1,200
1,200
1,200
1,200
1,200
600
600
600
600
600
250
250
250
250
250
Derating Curve
IGBT Applications
Notes:
The MHI200x-xxD series is a good
choice for applications involving high
speed switching, such as driving IGBTs.
They are designed to withstand the
extra stress caused by the high voltage
switching transients present in IGBT
drive circuits.
All of the MHIxxx series have isolation
levels that range from 5.2 to 8 kV. Many
of these have reinforced insulation. The
high isolation levels (and the correspondingly low capacitive coupling rates) allow
them to be safely used in applications
with highly dynamic switched AC or DC.
Mechanical Dimensions
Pin Connections
Pin
1
7
8
9
10
16
Pin
1
7
8
9
10
16
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
Single Output
-VIN
No Connection
No Connection
+VOUT
-VOUT
+VIN
Dual Output
-VIN
No Connection
Common
+VOUT
-VOUT
+VIN
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]