MPD MG212S12E Mg200xe sery Datasheet

MG200xE Series
Low Cost, 2W
Compact MiniDIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 2W Output Power
• Compact MiniDIP Case
Input
Parameter
Input Voltage Range
• High Efficiency
• 1,500 VDC Isolation
Input Filter
• Single and Dual Outputs
Output
• >3.5 MHour MTBF
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 1
• -40°C to +85°C Operation
• LOW COST
Ripple & Noise (20 MHz), See Note 2
3.0 kV Isolation
Models
Available
Conditions
Min.
3.3 VDC Input 2.97
5 VDC Input 4.50
12 VDC Input 10.80
24 VDC Input 21.60
Internal Capacitor
Typ.
3.3
5.0
12.0
24.0
Max.
3.63
5.50
13.20
26.40
Units
Conditions
Typ.
±2.5
Max.
Units
%
%
Min.
For VIN Change of 1%
See Model Selection Guide
Output Voltage <12 VDC
60
15 VDC, 24 VDC Output
75
Temperature Coefficient
5 VDC & 12 VDC Input
3.3 VDC & 24 VDC Input
Output Short Circuit
±1.2
VDC
mV P - P
±0.03
%/°C
Continuous (Autorecovery)
Momentary (1.0 Sec.)
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Conditions
60 Seconds
500 VDC
100 kHz, 0.1V
Conditions
EMC Compliance, Single Output
EMC Compliance, Dual Output
Typ.
Max.
20
100
300
Units
VDC
M
pF
kHz
Min.
Conducted
Radiated
EMI Compliance, See Note 4
Min.
1,500
1,000
Electrostatic Discharge (ESD)
Typ.
Max.
Units
CISPR22/EN 55022 Level B
CISPR22/EN 55022 Level B
EN 61000-4-2 Level B Contact ±8 kV
EN 61000-4-2 Level B Contact ±6 kV
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
Max.
+85
+125
Units
°C
°C
95
%
0.787 x 0.394 x 0.323 Inches (20.0 x 10.0 x 8.2 mm)
Non-Conductive Black Plastic (UL-94V0)
0.08 Oz (2.4g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
3.5
Typ.
Max.
Units
MHours
Conditions
3.3 VDC Input
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
5.0
9.0
18.0
30.0
300
Units
Absolute Maximum Ratings
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MG203S-05E
MG205S-05E
MG205S-12E
MG205S-15E
MG205D-05E
MG205D-09E
MG205D-12E
MG205D-15E
MG212S-05E
MG212S-12E
MG212S-24E
MG212D-05E
MG212D-09E
MG212D-12E
MG212D-15E
MG224S-05E
MG224S-09E
MG224S-12E
MG224D-05E
MG224D-09E
MG224D-15E
Output
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
3.3
2.97 - 3.63
757
40
5
4.5 - 5.5
500
25
5
4.5 - 5.5
476
25
5
4.5 - 5.5
476
25
5
4.5 - 5.5
500
25
5
4.5 - 5.5
482
25
5
4.5 - 5.5
476
25
5
4.5 - 5.5
476
25
12
10.8 - 13.2
205
15
12
10.8 - 13.2
198
15
12
10.8 - 13.2
198
15
12
10.8 - 13.2
205
15
12
10.8 - 13.2
198
15
12
10.8 - 13.2
196
15
12
10.8 - 13.2
198
15
24
21.6 - 26.4
101
8
24
21.6 - 26.4
99
8
24
21.6 - 26.4
99
8
24
21.6 - 26.4
101
8
24
21.6 - 26.4
99
8
24
21.6 - 26.4
99
8
Voltage
Current
(VDC)
(mA, Max)
5.0
5.0
12.0
15.0
±5.0
±9.0
±12.0
±15.0
5.0
12.0
24.0
±5.0
±9.0
±12.0
±15.0
5.0
9.0
12.0
±5.0
±9.0
±15.0
400
400
167
133
±200
±111
±83
±67
400
167
83
±200
±111
±83
±67
400
222
167
±200
±111
±67
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. When measuring output ripple, it is recommended that an external 1 µF ceramic capacitor & 10 µF electrolytic
capacitor be placed in parallel from the +Vout pin to the -Vout pin for single output models, or from each output
to common for dual output models.
3. Operation at no load will not damage these units, however, they may not meet all specifications.
4. These converters are specified for operation without external components. However, in some applications the
addition of input/output capacitors will enhance stability and reduce output ripple. The simple connection shown
below will typically meet EN 55022 Class B. For dual output units, a capacitor should be connected from each
output to common.
VIN
3.3 VDC
5 VDC
12 VDC
24 VDC
C1
4.7 µF/50V
4.7 µF/50V
2.2 µF/50V
1.0 µF/50V
L1
6.8 µH
6.8 µH
6.8 µH
6.8 µH
VOUT
5 VDC
9 VDC
12 VDC
15 VDC
24 VDC
±5 VDC
±7 VDC
±9 VDC
±12 VDC
±15 VDC
Output
Load
Capacitive Efficiency Fuse Rating
Regulation
Load
Slow-Blow
Current
(%, Typ)
(µF Max)
(mA)
(mA, Min)
% Typ.
40.0
12.0
220
80
1,500
40.0
12.0
220
80
1,000
17.0
8.0
220
84
1,000
13.0
7.0
220
84
1,000
±20.0
12.0
100
80
1,000
±11.0
9.0
100
83
1,000
±8.0
8.0
100
84
1,000
±7.0
7.0
100
84
1,000
40.0
12.0
220
81
500
17.0
8.0
220
84
500
8.0
6.0
220
84
500
±20.0
12.0
100
81
500
±11.0
9.0
100
84
500
±8.0
8.0
100
85
500
±7.0
7.0
100
84
500
40.0
12.0
220
82
250
22.0
9.0
220
84
250
17.0
8.0
220
84
250
±20.0
12.0
100
82
250
±11.0
9.0
100
84
250
±7.0
7.0
100
84
250
Derating Curve
Mechanical Dimensions
C2
10 µF
4.7 µF
2.2 µF
1.0 µF
1.0 µF
4.7 µF
2.2 µF
2.2 µF
1.0 µF
0.47 µF
5. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Pin Connections
Pin
Single
Dual
Pin
Single
Dual
1
-VIN
-VIN
9
+VOUT
+VOUT
7
NC
NC
11
No Pin
-VOUT
8
-VOUT
Common
14
+VIN
+VIN
NC = No Connection
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Pin 1 is marked by a “dot” or indentation on the unit
FAX: (781) 344-8481
•
E-Mail: [email protected]