MPD MB5024S24RU Mb5000ru sery Datasheet

MB5000RUSeries
Compact, 1 x 2 Inch
50W, 4:1 Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
Parameter
• 50W Output Power
Input Start Voltage
• 4:1 Input Voltage Range
• 1,500 VDC Isolation
• Very High Efficiency
• Compact 1 x 2 Inch Case
• Ten Standard Models
• Remote ON/OFF Control
• Industry Standard Pin-Out
Input Shutdown Voltage
Start-Up Time, See Note 1
Input Filter
Conditions
Min.
24 VDC Input
48 VDC Input
24 VDC Input
48 VDC Input
Nominal VIN, Constant Resistive Load
LC Filter
Typ.
Max.
9.0
18.0
7.5
16.0
Units
VDC
VDC
30
mS
Max.
±1.0
±0.5
±0.5
Units
%
%
%
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 2
Ripple & Noise, See Note 3
Transient Recovery Time, See Note 4
Transient Response Deviation
Temperature Coefficient
Output Power Protection
Over Temperature Protection
Output Short Circuit, See Note 5
Conditions
Min.
Typ.
VIN = Min to Max
3.3 & 5.0 VOUT Models
12, 15 & 24 VOUT Models
100
150
250
±3.0
25% Load Step Change
mV P - P
±5.0
±0.02
Hiccup Mode
150
Shutdown Temperature
+110
Continuous (Autorecovery)
µSec
%
%/°C
%
°C
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
Min.
60 Seconds 1,500
500 VDC 1,000
100 kHz, 1V
Typ.
Max.
2,200
285
Units
VDC
M⍀
pF
kHz
Environmental
Parameter
Operating Temperature Range,
Ambient Without Heatsink
Operating Temperature Range,
Ambient With Heatsink
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
3.3 VOUT Models
12, & 15 VOUT Models
5.0 & 24 VOUT Models
3.3 VOUT Models
12, & 15 VOUT Models
5.0 & 24 VOUT Models
Case
Min.
Typ.
-40
+25
-40
+25
-50
Free Air Convection
RH, Non-condensing
Max.
+61
+53
+46
+69
+62
+57
+105
+125
Units
95
%
°C
°C
°C
°C
2.0 x 1.0 x 0.43 Inches (50.8 x 25.4 x 11.0 mm)
Metal with Non-Conductive Base
1.20 Oz (34g)
Reliability Specifications
Parameter
MTBF
Conditions
Min.
MIL HDBK 217F, 25°C, Gnd Benign 233.5
Typ.
Max.
Units
kHours
Typ.
Max.
50.0
100.0
260.0
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
-0.7
-0.7
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Nominal
Range
24
24
24
24
24
48
48
48
48
48
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
MB5024S-03RU
MB5024S-05RU
MB5024S-12RU
MB5024S-15RU
MB5024S-24RU
MB5048S-03RU
MB5048S-05RU
MB5048S-12RU
MB5048S-15RU
MB5048S-24RU
Current (mA)
Output
Reflected
Over
Fuse Rating
Ripple
Voltage Efficiency Capacitive
Load
Slow-Blow
Current Voltage Current Current Protection (%, Typ)
(µF Max)
(A)
Full-Load No-Load (mA, Typ)
1,528
2,290
2,267
2,263
2,286
764
1,145
1,134
1,134
1,143
80
60
80
80
80
40
30
60
60
50
40
40
40
40
40
30
30
30
30
30
(VDC)
3.3
5.0
12.0
15.0
24.0
3.3
5.0
12.0
15.0
24.0
For heatsink option, add suffix “H” to model number (i.e. MB5024S-03RU-H)
Notes:
1. Start up time is measured at nominal input and with a constant resistive load.
2. Load regulation is specified for a load change of minimum load to full load.
3. When measuring output ripple, it is recommended that an external 1 µF capacitor and 10 µF capacitor be
connected in parallel from the +VOUT to the -VOUT pins.
4. Transient recovery is measured to within a 1% error band for a load step change of 25%.
5. Short circuit protection is provided by a “hiccup mode” circuit.
6. Operation at no-load will not damage the unit.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating.
External Trim
An external resister may be added to adjust the converter
output.
To adjust the output UP, connect a 5%, 3W resistor between
the minus output pin (5) and the Vout trim pin (6). To adjust
the output DOWN, connect a 5%, 3W resistor between the plus
output pin (4) and the Vout trim pin (6).
The trim table at right gives suggested resistor values for
this adjustment.
(mA, Max) (mA, Min)
10,000
10,000
4,170
3,330
2,080
10,000
10,000
4,170
3,330
2,080
(VDC)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
3.9
6.2
15.0
18.0
30.0
3.9
6.2
15.0
18.0
30.0
90
91
92
92
91
90
91
92
92
91
26,000
17,000
3,000
2,000
750
26,000
17,000
3,000
2,000
750
10.0
10.0
10.0
10.0
10.0
5.0
5.0
5.0
5.0
5.0
Remote On/Off
Applying a signal to pin 3 will turn the unit ON/OFF. If the pin is left open, the unit operates. If
grounded, the unit will shut off. The specifications for the ON/OFF function are:
Parameter
Min
Supply On
Supply Off
Standby Input Current
Control Common
Control Input Current (ON)
Control Input Current (OFF)
3.5
0.0
Typ
Max
Units
12.0
1.2
VDC
VDC
2.5
mA
Referenced to Negative Input (pin 2)
mA
0.5
-0.5
mA
MB50xxS-03RU
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
72.61
32.55
19.20
12.52
8.51
5.84
3.94
2.51
1.39
0.50
Volts
k⍀
Trim Up
Vout
RUP
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
60.84
27.40
16.25
10.68
7.34
5.11
3.51
2.32
1.39
0.65
Volts
k⍀
MB50xxS-05RU
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
138.88
62.41
36.92
24.18
16.53
11.44
7.79
5.06
2.94
1.24
Volts
k⍀
Trim Up
Vout
RUP
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
106.87
47.76
28.06
18.21
12.30
8.36
5.55
3.44
1.79
0.48
Volts
k⍀
MB50xxS-12RU
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
413.55
184.55
108.22
70.05
47.15
31.88
20.98
12.80
6.44
1.35
Volts
k⍀
Trim Up
Vout
RUP
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
351.00
157.50
93.00
60.75
41.40
28.50
19.29
12.37
7.00
2.70
Volts
k⍀
MB50xxS-15RU
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
530.73
238.61
141.24
92.56
63.35
43.87
29.96
19.53
11.41
4.92
Volts
k⍀
Trim Up
Vout
RUP
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
422.77
189.89
112.26
73.44
50.15
34.63
23.54
15.22
8.75
3.58
Volts
k⍀
MB50xxS-24RU
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
333.39
148.80
87.26
56.50
38.04
25.73
16.94
10.35
5.22
1.12
Volts
k⍀
Trim Up
Vout
RUP
Volts
k⍀
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
243.70
108.50
63.43
40.90
27.38
18.37
11.93
7.10
3.34
0.34
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Derating Curves
MB50xxS-03RU Without Heatsink
MB50xxS-03RU With Heatsink
MB50xxS-12RU, -15RU Without Heatsink
MB50xxS-12RU, -15RU With Heatsink
MB50xxS-05RU, -24RU Without Heatsink
MB50xxS-05RU, -24RU With Heatsink
EMC Specifications
Parameter
External Component Connection
Standard
Radiated Emissions
Conducted Emissions
ESD
EN 55022
Class A/B
EN 55022
Class A/B
EN 61000-4-2 Criteria B; ±8 kV Air, ±6 kV Contact
RS
EN 61000-4-3
Criteria A; 10V/m
EFT, See Notes
EN 61000-4-4
Criteria A; ±2 kV
Surge, See Notes
EN 61000-4-5
Criteria A; ±1 kV
CS
EN 61000-4-6
Criteria A; 10 V/m
Notes:
All units should meet EN 55022 (CE/RE) class A/B with the simple external circuit shown at right. To
meet the requirements of EN 61000-4-4 and EN 61000-4-5, the value of C1 should be changed to
220 µF/100V. Contact the factory for more information.
Standard
EN55022 Class A
EN55022 Class B
Model
MB5024S-xxRU
C1
10 µF/50V 1210 X7S
C2
---
L1
1.5 µH
L2
---
C3
---
C4
---
C5
1,000 pF/2kV 1206 MLCC
1,000 pF/2kV 1206 MLCC
MB5048S-xxRU
3.3 µF/100V 1210 X7S
---
6.8 µH
---
---
---
MB5024S-xxRU
3.3 µF/100V 1210/X7S
3.3 µF/100V 1210/X7S
---
1 mH
3.3 µF/100V 1210/X7S
1,200 pF/2kV 1808 X7R
1,200 pF/2kV 1808 X7R
MB5048S-xxRU
3.3 µF/100V 1210/X7S
3.3 µF/100V 1210/X7S
---
1 mH
3.3 µF/100V 1210/X7S
1,200 pF/2kV 1808 X7R
1,200 pF/2kV 1808 X7R
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
5
6
Mechanical Dimensions: With Optional Heatsink
Single Output
+Vin
-Vin
Remote On/Off
+Vout
-Vout
Trim
For the heatsink option, add suffix “H” to the
model number (i.e. MB5048S-24RU-H)
Notes:
MicroPower Direct
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Heatsink is black, anodized aluminum
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages