Infineon BAS3005A-02V Low vf schottky diode Datasheet

BAS3005A...
Low VF Schottky Diode
• Forward current: 0.5 A
• Reverse voltage: 30 V
• Very low forward voltage
(typ. 0.45 V @ IF = 0.5 A)
• For low loss, fast-recovery protecting
and clamping applications
• Pb-free (RoHS compliant) package 1)
• Qualified according AEC Q101
BAS3005A-02V
Type
BAS3005A-02V*
Package
SC79
Configuration
single
Marking
2
* Preliminary data
Maximum Ratings at TA = 25°C, unless otherwise specified
Parameter
Symbol
Diode reverse voltage2)
VR
30
V
Forward current 2)
IF
500
mA
500
mA
3.5
A
Average rectified forward current (50/60Hz, sinus) I FAV
Repetitive peak forward current
I FRM
Value
Unit
(tp ≤ 1 ms, D ≤ 0.25)
Non-repetitive peak surge forward current
I FSM
5
(t ≤ 10 ms)
150
Junction temperature
Tj
Operating temperature range
T op
-55 ... 125
Storage temperature
T stg
-65 ... 150
°C
1Pb-containing
2For
package may be available upon special request
TA > 25 °C the derating of VR and IF has to be considered.
1
2007-04-19
BAS3005A...
Thermal Resistance
Parameter
Symbol
Junction - soldering point 1)
RthJS
Value
Unit
tbd
K/W
Electrical Characteristics at TA = 25°C, unless otherwise specified
Parameter
Symbol
Values
min.
typ. max.
DC Characteristics
Reverse current2)
IR
VR = 5 V
-
-
15
VR = 10 V
-
-
30
VR = 30 V
-
-
300
Forward voltage2)
IF = 1 mA
-
200
260
IF = 10 mA
-
260
310
IF = 100 mA
-
340
390
IF = 500 mA
-
450
500
-
10
15
CT
µA
mV
VF
AC Characteristics
Diode capacitance
Unit
pF
VR = 5 V, f = 1 MHz
1For
calculation of RthJA please refer to Application Note Thermal Resistance
2Pulsed
test: tp = 300 µs; D = 0.01
2
2007-04-19
BAS3005A...
Diode capacitance CT = ƒ (VR)
Reverse current IR = ƒ (TA)
f = 1MHz
VR = Parameter
10 -2
35
A
pF
10 -3
IR
CT
25
20
10 -4
30 V
20 V
10 V
5V
15
10
10 -5
5
0
0
5
10
15
20
V
10 -6
0
30
25
50
75
°C
100
VR
150
TA
Reverse current IR = ƒ(VR)
TA = Parameter
Forward Voltage VF = ƒ (TA)
IF = Parameter
10 -2
0.5
A
V
125 °C
10 -3
500 mA
0.4
10 -4
VF
IR
0.35
85 °C
100 mA
0.3
0.25
10 mA
10 -5
0.2
25 °C
1 mA
0.15
10 -6
0.1
0.05
10 -7
0
5
10
15
20
V
0
-50
30
VR
-25
0
25
50
75
100
°C
150
TA
3
2007-04-19
BAS3005A...
Forward current IF = ƒ (VF)
TA = Parameter
10 0
A
10 -1
IF
10 -2
125 °C
85 °C
25 °C
- 40 °C
10 -3
10 -4
10 -5
10 -6
0
0.1
0.2
0.3
0.4
V
0.6
VF
4
2007-04-19
Package SC79
BAS3005A...
Package Outline
0.2
M
A
+0.05
0.13 -0.03
0.8 ±0.1
0.2 ±0.05
10˚MAX.
1.6 ±0.1
1
0.3 ±0.05
Cathode
marking
10˚MAX.
1.2 ±0.1
A
2
0.55 ±0.04
0.35
1.35
Foot Print
0.35
Marking Layout (Example)
2005, June
Date code
BAR63-02V
Type code
Cathode marking
Laser marking
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel
Reel ø180 mm = 8.000 Pieces/Reel (2 mm Pitch)
Reel ø330 mm = 10.000 Pieces/Reel
Cathode
marking
0.4
0.93
0.2
8
1.96
Reel with 2 mm Pitch
2
1.33
Standard
4
Cathode
marking
5
0.66
2007-04-19
BAS3005A...
Date Code marking for discrete packages with
one digit (SCD80, SC79, SC75 1) ) CES-Code
Month 2 0 03
2 0 04
2005
2006
2 0 07
2008
2009
2010
2011
2012
2 0 13
2014
01
a
p
A
P
a
p
A
P
a
p
A
P
02
b
q
B
Q
b
q
B
Q
b
q
B
Q
03
c
r
C
R
c
r
C
R
c
r
C
R
04
d
s
D
S
d
s
D
S
d
s
D
S
05
e
t
E
T
e
t
E
T
e
t
E
T
06
f
u
F
U
f
u
F
U
f
u
F
U
07
g
v
G
V
g
v
G
V
g
v
G
V
08
h
x
H
X
h
x
H
X
h
x
H
X
09
j
y
J
Y
j
y
J
Y
j
y
J
Y
10
k
z
K
Z
k
z
K
Z
k
z
K
Z
11
l
2
L
4
l
2
L
4
l
2
L
4
12
n
3
N
5
n
3
N
5
n
3
N
5
1) New Marking Layout for SC75, implemented at October 2005.
.
6
2007-04-19
BAS3005A...
Edition 2006-02-01
Published by
Infineon Technologies AG
81726 München, Germany
© Infineon Technologies AG 2007.
All Rights Reserved.
Attention please!
The information given in this dokument shall in no event be regarded as a guarantee
of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any
examples or hints given herein, any typical values stated herein and/or any information
regarding the application of the device, Infineon Technologies hereby disclaims any
and all warranties and liabilities of any kind, including without limitation warranties of
non-infringement of intellectual property rights of any third party.
Information
For further information on technology, delivery terms and conditions and prices
please contact your nearest Infineon Technologies Office (www.infineon.com).
Warnings
Due to technical requirements components may contain dangerous substances.
For information on the types in question please contact your nearest
Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or
systems with the express written approval of Infineon Technologies, if a failure of
such components can reasonably be expected to cause the failure of that
life-support device or system, or to affect the safety or effectiveness of that
device or system.
Life support devices or systems are intended to be implanted in the human body,
or to support and/or maintain and sustain and/or protect human life. If they fail,
it is reasonable to assume that the health of the user or other persons
may be endangered.
7
2007-04-19
Similar pages