Mean Well GC220 220w single output battery charger Datasheet

GC220
220W Single Output Battery Charger
series
Features :
2 stage charging characteristic
Universal AC input / Full range
Built-in active PFC function, PF>0.90
No load power consumption<1W
3 pole AC inlet IEC320-C14
Class power ( with earth pin)
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Fully enclosed plastic case
2 color LED indicator for charging status
Approvals: TUV / UL / CB / FCC / CE
2 years warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
( for GC220Axx-AD1 only)
ORDER NO.
OUTPUT CONNECTOR
SAFETY
GC220Axx-R7B (standard model)
4pin power din
TUV / CB / FCC / CE
GC220Axx-AD1 (optional model)
Anderson connector
UL / TUV / CB / FCC / CE
GC220Axx-
xx=12,24,48 ;
=R7B,AD1
SPECIFICATION
ORDER NO.
GC220A12-
GC220A24-
GC220A48-
GC220A12
13.6V
GC220A24
27.2V
GC220A48
54.4V
RECOMMENDED BATTERY
80 ~ 200Ah
CAPACITY
Note.2
40 ~ 125Ah
20 ~ 65Ah
CONTINUOS OUTPUT
CURRENT (Typ.)
13.5A
8A
4A
RATED POWER
183.6W
217.6W
217.6W
SAFETY MODEL NO.
DC VOLTAGE (Typ.)
OUTPUT
LED INDICATOR
VOLTAGE RANGE
INPUT
Charging(CC) : RED
Floating charging(CV) : GREEN
Note.3 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.90 / 230VAC
EFFICIENCY (Typ.)
89%
AC CURRENT
INRUSH CURRENT (max.)
4A / 115VAC
LEAKAGE CURRENT(max.)
1.5mA / 240VAC
OVERLOAD
92.5%
93%
2A / 230VAC
120A / 230VAC
90 ~ 110% rated output power
Note.4
Protection type : Constant current limiting recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
PF>0.98 / 115VAC at full load
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
95
10 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +60 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
-40 ~ +85
, 10 ~ 95% RH
0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1012 (for GC220Axx-AD1 only), TUV EN60950-1 approved
I/P-O/P: 3KVAC
SAFETY &
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022 class B, FCC PART 15 class B / CISPR22 class B
(Note. 5)
HARMONIC CURRENT
Compliance to EN61000-3-2,3
OTHERS
CONNECTOR
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
MTBF
DIMENSION
PACKING
PLUG
190Khrs min. MIL-HDBK-217F(25
210*85*46mm (L*W*H)
1.1Kg; 12pcs/14.2Kg/0.73CUFT(GC220Axx-R7B)
1.2Kg; 12pcs/15.4Kg/1CUFT(GC220Axx-AD1)
See page 2 ; Other type available by customer requested
CABLE
See page 2 ; Other type available by customer requested
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. This is MeanWell's suggested range, please consult your battery manufacturer for their suggestions about maximum charging current limitation.
3. Derating may be needed under low input voltage. Please check the derating curve for more details.
4. Constant current operation region is within 50~100% rated output voltage.
5. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that whole system complies with the
EMC directives.
File Name:GC220-SPEC 2010-12-17
GC220
220W Single Output Battery Charger
Mechanical Specification
Case No.961A
46
series
Unit:mm
210
UL2464 16AWGx4C 1000 50mm
30 3mm
POWER LED
85
23
14
(R7B)
46
210
SJTW 14AWGx2C 1000 50mm
30 3mm
85
POWER LED
(AD1)
Charging Curve
Plug Assignment
DC output connector (standard)
(V,I)
R7B
(KYCON KPP-4S or equivalent)
Stage 1
Stage 2
Constant Current Area
Constant Voltage Area
PIN NO. OUTPUT
2
1
3
4
1,4
+V
2,3
-V
V
100%
AC FG
-V connected to AC FG
Fast Charging
DC output connector (optional)
10%
AD1
[ housing: Anderson 1327FP(red), 1327G6FP(black)
contacts: Anderson 261G2 (45A) or equivalent ]
Red(+V)
Float Charging
Red
Color of LED
I
TIME
Green
Black(-V)
Derating Curve
Static Characteristics
100
230VAC
100
90
80
80
70
100VAC
LOAD (%)
LOAD (%)
60
50
40
20
-30
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:GC220-SPEC 2010-12-17