SPSEMI K60-135 Radial leaded device Datasheet

PPTC/K60 Series
Features
Applications
Radial leaded Devices
Almost anywhere there is a low voltage
Cured,flame retardant epoxy polymer
power supply, up to DC30V and a load
insulating material meets UL94V-0
to be protested, including:
requirements
Automotive electronics
Bulk packaging,or tape and reel
Medical products
available on most models
Industrial controls
Product dimensions (mm)
Model
Fig
A(max)
B(max)
C(max)
D(typ)
K60-005
1(2)
5.0
8.5
3
5.1
K60-010
1(2)
5.5
9.5
3
5.1
K60-017
1(2)
7.4
12.7
3
5.1
K60-020
1(2)
7.4
12.7
3
5.1
K60-025
1(2)
1
7.4
12.7
3
5.1
K60-030
K60-040
1
1(2)
2
7.4
13.0
3
5.1
7.8
16.2
3
5.1
K60-050
2
7.8
16.2
3
5.1
K60-065
2
9.7
17.8
3
5.1
K60-075
2
10.4
18.4
3
5.1
K60-090
2
11.7
18.4
3
5.1
K60-110Y
1
13.0
18.0
3
5.1
5.1
K60-110F
3
13.0
18.0
3
K60-135
1
14.5
19.6
3
5.1
K60-160
1
16.3
21.3
3
5.1
K60-185
1
17.8
22.9
3
5.1
K60-200
1
17.8
22.9
3
5.1
10.2
K60-250
1
21.3
26.4
3
K60-300
1
21.3
26.4
3
10.2
K60-375
1
28.5
33.5
3
10.2
K60-500
1
28.5
33.5
3
10.2
Physical Characteristcs
Material:Leads
K60-005~030
Tin plated copper,22AWG0.60mm or Tin-plated nickel-copper alloy,24AWG0.50mm
K60-040~090
Tin plated copper,22AWG,0.60mm
K60-300~500
Tin plated copper,20AWG,0.80mm
Environmental Specifications
Test
conditions
Resistance change
±8% typical
Passive aging
+85℃,100hts
Humidity aging
+85℃,85%R.H.,100hrs
±8% typical
Thermal shock
+125℃,to-55℃,10times
±12% typical
Resistance to solvent
Vibration
Storage conditions:-40℃ to 85℃
REV.2014.05.01
MIL-STD-202,Method 215
No change
MIL-STD-202,Method 201
No change
01 | www.spsemi.cn
PPTC/K60 Series
Electrical characteristics(25℃ )
Part
number
K60-005
K60-010
K60-017
K60-020
K60-025
K60-030
K60-040
K60-050
K60-065
K60-075
K60-090
K60-110Y
K60-110F
K60-135
K60-160
K60-185
K60-200
K60-250
K60-300
K60-375
K60-500
Ihold
Itrip
Vmax
Imax
Pd max
(A)
0.05
0.10
0.17
0.20
0.25
0.30
0.40
0.50
0.65
0.75
0.90
1.10
1.10
1.35
1.60
1.85
2.00
2.50
3.00
3.75
5.00
(A)
0.10
0.20
0.34
0.40
0.50
0.60
0.80
1.00
1.30
1.50
1.80
2.20
2.20
2.70
3.20
3.70
4.00
5.00
6.00
7.50
10.00
(Vdc)
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
(A)
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
(w)
0.30
0.38
0.48
0.41
0.45
0.49
0.56
0.77
0.88
0.92
0.99
0.15
0.15
0.12
0.09
0.08
0.07
0.05
0.04
0.03
0.02
Maximum Time To Trip
Current
Time
(A)
(S)
0.25
5
0.50
5
0.85
5
1.00
5
1.25
5
1.50
5
2.00
5
2.50
5
3.25
5
3.75
5
4.50
5
5.50
8
5.50
8
6.75
8
8.00
8
9.25
8
10.00
8
12.50
8
15.00
8
24
18.75
25.00
24
Rmin
(Ω)
7.30
2.50
2.00
1.50
1.00
0.76
0.55
0.50
0.31
0.25
0.20
0.15
0.15
0.12
0.09
0.08
0.07
0.05
0.04
0.03
0.02
Ihold
Hold Current:Maximum current device will not trip in 25℃ still air.
Itrip
Trip current:Minimum current at which the device will always trip in 25℃ still air
Vmax
Maximum operating volatge device can withstand without damage at ratde current(imax).
Imax
Maximum fault current device can withstand without damage at rated voltage(Vmax).
Typical power dissipatde from device when in the tripped state in 25℃ still air.
Pd
Resistance
Rmax
(Ω )
20.00
7.50
5.21
2.84
1.95
1.38
0.88
0.79
0.50
0.42
0.33
0.27
0.27
0.21
0.16
0.14
0.14
0.10
0.08
0.06
0.06
R1max
(Ω)
30.00
12.00
8.00
4.49
3.00
2.20
1.40
1.20
0.74
0.62
0.49
0.40
0.40
0.32
0.24
0.21
0.21
0.15
0.12
0.10
0.10
70
0.032
0.05
0.09
0.10
0.12
0.14
0.20
0.25
0.33
0.39
0.47
0.55
0.55
0.68
0.80
0.92
1.08
1.30
1.50
1.95
2.70
80
0.025
0.03
0.06
0.07
0.09
0.10
0.14
0.18
0.24
0.28
0.33
0.40
0.40
0.50
0.60
0.67
0.80
0.90
1.09
1.39
2.00
Rmin/max Minimum/Maximum device resistance prior to tripping at 25℃.
Maximum resistance of device at 25℃ measured one hour after trippde tripping.
R1max
*CAUTION Operation beyond the specified rating may result in damage and possible arcing.
Thermal Derating Chart-IH(A)
Part number
K60-005
K60-010
K60-017
K60-020
K60-025
K60-030
K60-040
K60-050
K60-065
K60-075
K60-090
K60-110Y
K60-110F
K60-135
K60-160
K60-185
K60-200
K60-250
K60-300
K60-375
K60-500
REV.2014.05.01
-40
0.077
0.18
0.28
0.34
0.42
0.52
0.66
0.83
1.10
1.26
1.52
1.82
1.82
2.20
2.60
3.00
3.21
4.05
4.82
6.02
8.00
-20
0.069
0.15
0.24
0.29
0.36
0.44
0.57
0.74
0.95
1.11
1.30
1.60
1.60
1.91
2.30
2.63
2.72
3.58
4.16
5.19
6.80
Maximum ambidnt operating temperatures(℃)
0
25
40
50
60
0.061
0.050
0.044
0.040
0.036
0.13
0.10
0.08
0.07
0.06
0.20
0.17
0.14
0.12
0.10
0.25
0.20
0.16
0.14
0.13
0.31
0.25
0.20
0.18
0.16
0.38
0.30
0.24
0.22
0.18
0.50
0.40
0.32
0.29
0.24
0.63
0.50
0.41
0.36
0.30
0.82
0.65
0.53
0.47
0.40
0.95
0.75
0.61
0.54
0.45
1.15
0.90
0.73
0.65
0.55
1.35
1.10
0.90
0.79
0.65
1.35
1.10
0.90
0.79
0.65
1.65
1.35
1.09
0.96
0.80
1.95
1.60
1.30
1.13
1.00
2.30
1.85
1.50
1.33
1.12
2.38
2.00
1.62
1.44
1.26
3.02
2.50
2.02
1.80
1.55
3.62
3.00
2.43
2.16
1.85
4.50
3.75
3.02
2.68
2.30
5.95
5.00
4.05
3.60
3.15
02 | www.spsemi.cn
PPTC/K60 Series
Typical Time-To-Trip Curve At 25°C
Thermal Derating Curve
Average Time Current Curves
Derating Curves for K60 Series
0.100A
0.170A
1000
180
0.200A
0.300A
TIME IN SECOND
100
0.400A
0.500A
0.650A
10
0.750A
0.900A
1.10A
1
1.35A
1.60A
1.85A
0.1
2.50A
3.00A
3.75A
0.01
0.1
1
10
Percentage of Derated Current
0.250A
160
140
120
100
80
60
40
20
0
-40
100
CURRENT IN AMPERES
-20
0
20
40
60
80
Temperature (°C)
Package Information
Bulk:
K60-005~110Y
1000pcs per bag
K60-110F~300
500pcs per bag
k60-375~500
200pcs per bag
REV.2014.05.01
03 | www.spsemi.cn
Similar pages