XP Power LPS-50-12 50w single output switching power supply Datasheet

LPS-50
50W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
Small and compact size
Built-in remote ON-OFF control
LED indicator for power on
100% full load burn-in test
Low profile:23mm thickness
2 years warranty
SPECIFICATION
MODEL
LPS-50-3.3
LPS-50-5
LPS-50-12
LPS-50-15
LPS-50-24
LPS-50-48
DC VOLTAGE
3.3V
5V
12V
15V
24V
48V
RATED CURRENT
10A
10A
4.2A
3.4A
2.1A
1.1A
CURRENT RANGE
0 ~ 12A
0 ~ 12A
0 ~ 5A
0 ~ 4.1A
0 ~ 2.5A
0 ~ 1.3A
RATED POWER
33W
50W
50.4W
51W
50.4W
52.8W
60W
60W
61.5W
60W
62.4W
RIPPLE & NOISE (max.) Note.2 50mVp-p
50mVp-p
80mVp-p
80mVp-p
80mVp-p
100mVp-p
VOLTAGE ADJ. RANGE
4.5 ~ 5.5V
10.8 ~ 13.2V
13.5 ~ 16.5V
21.6 ~ 27.2V
43.2 ~ 52.8V
PEAK LOAD(10sec.)
OUTPUT
Note.4 39.6W
VOLTAGE TOLERANCE Note.3
2.0%
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
3.0%
3.0%
2.0%
2.0%
1.0%
1.0%
SETUP, RISE TIME
100ms, 40ms/230VAC
HOLD TIME (Typ.)
70ms/230VAC
VOLTAGE RANGE
FREQUENCY RANGE
90 ~ 264VAC
47 ~ 63Hz
100ms, 40ms/115VAC at full load
12ms/115VAC at full load
127 ~ 370VDC
75%
81%
115VAC
0.9A
1.2A
230VAC
INRUSH CURRENT (Typ.)
0.6A
0.8A
AC CURRENT
(Typ.)
LEAKAGE CURRENT
OVER LOAD
PROTECTION
OVER VOLTAGE
FUNCTION
3.0%
LINE REGULATION
EFFICIENCY(Typ.)
INPUT
3 ~ 3.6V
3.0%
REMOTE ON/OFF
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
COLD START 18A/115VAC
<1mA / 240VAC
82%
84%
86%
27.6 ~ 32.4V
57.6 ~ 67.2V
35A/230VAC
122 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V power off
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
85%
, 10 ~ 95% RH
0.04%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
EMC
(Note 5)
OTHERS
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2 (EN50082-2) Heavy industry level, criteria A
DIMENSION
PACKING
NOTE
341.7Khrs min. MIL-HDBK-217F (25
195*55*23mm (L*W*H)
0.24Kg; 48pcs/12.5Kg/0.84CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:LPS-50-SPEC 2006-04-13
LPS-50
50W Single Output Switching Power Supply
Mechanical Specification
series
Unit:mm
195
185
1
CN3 2
5
4
3
2
1
45
55
CN1
1
2
CN2 3
4
SVR1
4-
3.8
23
LED
DC Output Connector (CN2) : JST B4P-VH or equivalent
Pin No.
1,2
3,4
AC Input Connector (CN1) : JST B5P-VH or equivalent
Assignment
AC/L
No Pin
AC/N
FG
Pin No.
1
2,4
3
5
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
Assignment
-V
+V
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
Remote ON/OFF Connector(CN3):JST B2B-XH or equivalent
Pin No.
1
2
Assignment
RC+
RC-
Mating Housing
Terminal
JST XHP
or equivalent
JST SXH-001T-P0.6
or equivalent
Block Diagram
fosc : 60KHz
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
POWER
SWITCHING
FG
RECTIFIERS
&
FILTER
DETECTION
CIRCUIT
PWM
CONTROL
O.L.P.
Derating Curve
+V
-V
O.V.P.
RC+
RC-
Static Characteristics (15V)
100
80
OUTPUT VOLTAGE (V)
2
1
1 Convection
LOAD (%)
60
2 18CFM Forced Air
40
20
-20
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
300
18
250
15
200
12
150
9
100
6
50
3
25
60
90
100
120
140
160
180
200
220
240
OUTPUT RIPPLE (mVp-p)
Ta=25
21
260
INPUT VOLTAGE (V) 60Hz
File Name:LPS-50-SPEC 2006-04-13
LPS-100
100W Single Output without PFC Function
series
Features :
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
Fix switching frequency at 134KHz
3 years warranty
SPECIFICATION
MODEL
OUTPUT
LPS-100-3.3 LPS-100-5
LPS-100-7.5 LPS-100-12 LPS-100-13.5 LPS-100-15 LPS-100-24 LPS-100-27 LPS-100-48
DC VOLTAGE
3.3V
5V
7.5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
20A
20A
13.3A
8.4A
7.5A
6.7A
4.2A
3.8A
2.1A
CURRENT RANGE
0 ~ 20A
0 ~ 20A
0 ~ 13.3A
0 ~ 8.4A
0 ~ 7.5A
0 ~ 6.7A
0 ~ 4.2A(6A 10s) 0 ~ 3.8A
0 ~ 2.1A
RATED POWER
66W
100W
99.75W
100.8W
101.25W
100.5W
100.8W(144W 10s) 102.6W
100.8W
RIPPLE & NOISE (max.) Note.2 150mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
150mVp-p
150mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
4.5 ~ 5.7V
3.0%
6 ~ 9V
2.0%
10 ~ 13.2V
2.0%
12 ~ 15V
2.0%
13.5 ~ 18V
2.0%
20 ~ 26.4V
1.0%
26 ~ 32V
1.0%
41 ~ 56V
1.0%
3 ~ 3.6V
VOLTAGE TOLERANCE Note.3 3.0%
LINE REGULATION
INPUT
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.5%
1.5%
1.5%
1200ms, 50ms/115VAC at full load
1.5%
0.5%
0.5%
0.5%
LOAD REGULATION
SETUP, RISE TIME
2.0%
2.0%
800ms, 50ms/230VAC
HOLD TIME (Typ.)
20ms/230VAC
VOLTAGE RANGE
88 ~ 132VAC / 176 ~ 264VAC auto switch
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
69%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2.3A/115VAC
0.5%
20ms/115VAC at full load
77%
248 ~ 370VDC
77%
79%
79%
80%
LEAKAGE CURRENT
COLD START 30A/115VAC
<1mA / 240VAC
OVER LOAD
105 ~ 140% (+24V: above 6.5A) rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
3.8 ~ 4.45V
80%
81%
81%
1.5A/230VAC
60A/230VAC
5.75 ~ 6.75V 9.4 ~ 10.9V
13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V
27.6 ~ 32.4V 33.7 ~ 39.2V 57.6 ~ 67.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
EMC
(Note 4)
OTHERS
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,11, Light industry level, criteria A
MTBF
203.6Khrs min. MIL-HDBK-217F (25
222*62*32mm (L*W*H)
0.45Kg; 24pcs/12.5Kg/1.76CUFT
DIMENSION
PACKING
NOTE
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. If the input range 85V-89V, the output load is changed from 0A-rated load, There will be reduced 20V for 1second (LPS-100-24).
6. Mounting holes M1 and M2 should be grounded for EMI purposes.
File Name:LPS-100-SPEC 2006-03-10
LPS-100
100W Single Output without PFC Function
Mechanical Specification
series
Unit:mm
222
212
5
5
FG
CN2
8
7
6
5
4
3
2
1
AC FUSE
F4A/250V
1
2
3
4
5
52
62
CN1
4-
+V ADJ.
32
3.5
AC Input Connector (CN1) : JST B5P-VH or equivalent
Assignment
FG
No pin
AC/N
AC/L
Pin No.
1
2,4
3
5
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
DC Output Connector (CN2) : JST B8P-VH or equivalent
Pin No.
1,2,3,4
5,6,7,8
Assignment
+V
-V
Terminal
JST SVH-21T-P1.1
or equivalent
Mating Housing
JST VHR
or equivalent
Block Diagram
fosc : 135KHz
RECTIFIERS
&
FILTER
115/230VAC
AUTO
SWITCH
EMI
FILTER
I/P
FG
O.L.P.
Output Derating
POWER
SWITCHING
RECTIFIERS
&
FILTER
+V
-V
DETECTION
CIRCUIT
PWM
CONTROL
O.V.P.
Static Characteristics (12V)
Ta=25
100
300
+12V
OUTPUT VOLTAGE (V)
12
80
LPS-100-5V
LOAD (%)
60
Convection
(3.3V,7.5V~48V)
40
20
-10
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
(HORIZONTAL)
250
11
200
10
150
9
100
+12V
8
50
7
25
60
80
100
120
140
160
180
200
220
240
OUTPUT RIPPLE (mVp-p)
13
18 CFM min
Forced Air
260
INPUT VOLTAGE (V) 60Hz
File Name:LPS-100-SPEC 2006-03-10