HGN-337 IEC 60320 INLET SOCKET WITH SWITCH AND A FUSE HOLDER, SNAP-IN MOUNT MECHANICAL DIMENSIONS (Unit: mm) 52.0 Use only with a 250V fuse 40.0 0.80 TYP. 36.0 FEATURES The HGN-337 power entry module feature a combination IEC Connector, two pole on/off switch and fuse holder that accepts both European 5 x 20mm or N. American 1/4” x 1 1/4” (3AG) fuse. The HGN-337 protects electronic equipment from common-mode and differential-mode interferences. 6.3 TYP. These filters are also available for Medical equipment with low leakage current to comply with UL 544 & UL2601. APPLICATIONS 55.0 Computer & networking equipment, Measuring & control equipment, Data processing equipment, laboratory instruments, Switching power supplies, other electronic equipment. A+0.2 TECHNICAL DATA • Rated Voltage: 125/250VAC • Rated Current: 1A, 2A, 3A, 4A, 6A, • Power Line Frequency: 50/60Hz • Max. Leakage Current each Line to Ground: @ 250VAC 50Hz: 0.5mA, max @ 250VAC 50Hz: 2µA*, max • Hipot Rating (one minute) Line to Ground: 2250VDC Line to Line: 1450VDC • Temperature Range: -25C to +85C 3.00 49.0 49.5 +0.2 4X R1.5 36.5 +0.2 * Medical application RECOMMENDED PANEL CUTOUT Specifications subject to change without notice. Dimensions (mm). See Appendix A for recommended power cord. See PDI full line catalog for detailed specifications on power cords. 62 145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail: [email protected] • www.powerdynamics.com HGN-337 Series Example & Ordering Code HGN-337 - 1 = = = = = CURRENT RATING (A): SCHEMATIC: M - F - 150 1 2 3 4 6 STANDARD TYPE = WITHOUT C(Y); C(X) ONLY =M BLANK TERMINAL: =F QUICK CONNECT (6.3 x 0.8) PANEL THICKNESS*: 0.06 (1.5MM) 0.062 (1.6MM) 0.08 (2.0MM) = 150 = 160 = 200 * More panel thickness options are available upon request Attenuation Tables & Schematics Non-Medical Applications Insertion loss in dB (50 Ohm circuit) P N' 2200pF E' 2200pF L(mH) Fuse L(mH) Fuse LOAD Fuse 0.033 F E 0.033 F 30 30 34 32 35 1M 30 L(mH) N LINE Current L Comm. Mode(L-G) MHz Diff. mode(L-L) MHz Rating Value .01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10 1A 10.3mA 18 30 40 57 50 50 64 29 9 13 13 45 65 70 60 2A 4.6mA 11 25 35 49 49 70 60 30 10 14 16 40 60 70 60 3A 2.5mA 5 20 30 41 48 54 60 34 10 14 18 30 55 70 61 4A 1.2mA 5 12 21 35 40 50 70 32 9 14 19 20 45 70 60 6A 0.8mA 2 10 20 30 34 45 55 35 9 14 19 19 40 70 60 P' - Medical Applications Insertion loss in dB (50 Ohm circuit) 32 30 28 18 13 41 38 33 23 19 51 40 38 30 27 48 42 38 32 29 37 36 30 32 29 31 30 23 30 29 22 21 18 22 25 9 9 9 9 9 11 11 15 13 18 15 11 14 19 21 50 42 38 19 19 67 67 55 44 47 82 82 82 82 84 71 75 76 79 82 37 38 35 40 50 E P 145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail: [email protected] • www.powerdynamics.com L(mH) N' E' Fuse LOAD 22 18 18 10 8 0.033 F 10.3mA 4.6mA 2.5mA 1.2mA 0.8mA N 0.033 F 1A 2A 3A 4A 6A Comm. Mode(L-G) MHz Diff. mode(L-L) MHz .01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10 30 1M L Value LINE Current Rating P' 63