AIMTEC AM8TW-2405SH30Z 8watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM8TW-Z
8Watt | DC-DC Converter
FEATURES:




Wide 4:1 input range
Remote On/Off control
High efficiency up to 87%
Over Voltage/Overload Protection




Operating temperature -40oC to + 85oC
Input / Output Isolation 1600 & 3000VDC
Continuous short circuit protection
Under voltage lockout for 3000VDC models
Models
Single output
Model
Input
Voltage (V)
Output
Voltage
(V)
Output
Current max
(mA)
Isolation
(VDC)
Max
Capacitive
Load(uF)
Efficiency
(%)
AM8TW-2403SZ
AM8TW-2405SZ
AM8TW-2412SZ
AM8TW-2415SZ
AM8TW-4803SZ
AM8TW-4805SZ
AM8TW-4812SZ
AM8TW-4815SZ
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
3.3
5
12
15
3.3
5
12
15
2000
1500
665
535
2000
1500
665
535
1600
1600
1600
1600
1600
1600
1600
1600
1330
1330
288
200
1330
1330
288
200
83
86
87
87
82
86
87
87
AM8TW-2403SH30Z
AM8TW-2405SH30Z
AM8TW-2412SH30Z
AM8TW-2415SH30Z
AM8TW-11003SH30Z
AM8TW-11005SH30Z
AM8TW-11012SH30Z
AM8TW-11015SH30Z
13-70
13-70
13-70
13-70
42-176
42-176
42-176
42-176
3.3
5
12
15
3.3
5
12
15
2000
1500
665
535
2000
1500
665
535
3000
3000
3000
3000
3000
3000
3000
3000
1330
1330
330
220
1330
1330
330
220
83
86
85
86
81
84
84
83
Input
Voltage (V)
Output
Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
Max
Capacitive
Load(uF)
Efficiency
(%)
Models
Dual output
Model
AM8TW-2405DZ
AM8TW-2412DZ
AM8TW-2415DZ
AM8TW-4805DZ
AM8TW-4812DZ
AM8TW-4815DZ
9-36
9-36
9-36
18-75
18-75
18-75
±5
±12
±15
±5
±12
±15
±800
±335
±265
±800
±335
±265
1600
1600
1600
1600
1600
1600
±900
±133
±90
±900
±133
±90
84
86
87
84
87
87
AM8TW-2405DH30Z
AM8TW-2412DH30Z
AM8TW-2415DH30Z
AM8TW-11005DH30Z
AM8TW-11012DH30Z
AM8TW-11015DH30Z
13-70
13-70
13-70
42-176
42-176
42-176
±5
±12
±15
±5
±12
±15
±800
±335
±265
±800
±335
±265
3000
3000
3000
3000
3000
3000
±900
±220
±100
±900
±220
±100
83
85
86
80
82
83
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 051e R12.F
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM8TW-Z
8Watt | DC-DC Converter
Input Specifications
Parameters
Voltage range
Nominal
Typical
24 for 1600VDC models
48 for 1600VDC models
24V or 48V for 3000VDC models
110V
Filter
Startup time
Absolute Maximum Rating
For 1600VDC Isolation models
For 3000VDC Isolation models
24 for 1600VDC models
48 for 1600VDC models
24V or 48V for 3000VDC models
110V
Maximum
9-36
18-75
13-70
42-176
 (Pi) Network
20
30
VDC
ms
-0.7-50
-0.7-100
100
185
100
Peak Input Voltage time
On/Off control
No Load Input Current
Input reflected current
Under voltage Lockout (On/Off)
Transient recovery time
Transient recovery deviation
Units
ON – 3.0 ~ 12VDC (or open)
OFF -0~1.2VDC (or short between pin 1 and 2/3), Idle current 5mA, typ.
15
With 12uH inductance
20
24V or 48V for 3000VDC models
On – 12V/ Off – 11.7
110V
On – 39.5V/ Off – 38
25% load step change, 1A/us
250
±3
3.3V output models only
±5
VDC
ms
mA
mAp-p
VDC
uS
%
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Tested metal case to Input and Output
Resistance
60 sec
60 sec
Capacitance
Typical
Rated
Units
1600 & 3000
1000
VDC
VDC
MOhm
>1000
1500
1000
For 1600VDC Isolation models
For 3000VDC Isolation models
pF
Output Specifications
Parameters
Voltage accuracy
Over voltage protection
Over load protection
Conditions
Typical
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Cross regulation (Dual)
Temperature coefficient
Ripple & Noise*
Minimum Load Current
±1
±1.5
48V nom 3000VDC models only
Zener Diode Clamp
For 1600VDC Isolation models
For 3000VDC Isolation models
For 3000VDC Isolation models 48V nom
Maximu
m
Units
%
%
150
160
170
%
Continuous
Auto-Recovery
HL-LL 1600VDC models
HL-LL 3000VDC models
0 – 100% load
25% load on one output - 100% load on second load
20MHz Bandwidth
±0.2
±0.5
±0.5
±5
±0.02
75
0
% of Vin
%
%
%/oC
mV p-p
% of Max
*Measured with 1uF ceramic capacitor.
www.aimtec.com
F 051e R12.F
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM8TW-Z
8Watt | DC-DC Converter
General Specifications
Parameters
Conditions
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Typical
100% load 1600VDC models
270
24 & 48V nom 3000VDC models
330
110V
220
Derating above +70
-55 to +125
Maximum
Units
KHz
oC
-40 to +85
oC
oC
105
Free air convection
95
Nickel plated Cooper
18
1.25 x 0.80 x 0.40 inches
31.80 x 20.30 x 10.20 mm
> 1,000,100 hours(MIL-HDBK-217F , Ground Benign, t=+25oC)
1.5mm from case for 10sec
260
% RH
g
oC
Safety Specifications
Parameters
Pin
1
2
3
9
11
14
16
22
23
Single
Remote On/Off
-V Input
-V Input
No Pin
N.C.
+V Output
-V Output
+V Input
+V Input
Dual
Remote On/Off
-V Input
-V Input
Common
-V Output
+V Output
Common
+V Input
+V Input
Dimensions
31.80
(1.25)
0.50
(0.02)
1 2
3
11
Bottom View
23 22
2.54
(0.10)
Printed Face
9
16
15.20
(0.60)
Pin Out Specifications
0.50
(0.02)
Standards for 1600VDC
models
CE (1600VDC models)
EN55022 Class A, EN55024
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria B (external 330uF/100V cap required)
IEC61000-4-5, Perf. Criteria B (external 330uF/100V cap required)
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
Meets IEC/EN60950-1
20.30
(0.80)
Agency Approval
14
5.08
(0.20)
3.05
(0.12)
10.20
(0.40)
N.C.: Not Connected
www.aimtec.com
F 051e R12.F
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM8TW-Z
8Watt | DC-DC Converter
Derating
70 ºC
Output Power (%)
100
80
Safe Operating Area
60
40
20
0
- 20
- 40
0
20
40
60
80
85
100
Ambient Temperature º C
Recommended Circuits for 1600VDC isolated models
C1
2.2uF, 100V
L
12uH
C2
2.2uF, 100V
C1
330uF, 100V
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.F
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages