Features
■
Low cost! Highly reliable!
■
Proven SMT-on-pcb construction
■
Qual tested; HALT tested; EMC tested
■
Designed to meet UL/ EN60950,
BASIC insulation (48VIN models)
■
mark available (48VIN models)
■
Output voltages: ±5, ±12 or ±15 Volts
■
Ultra-wide input voltage ranges:
4.7-7.5V, 9-36V or 18-75V
■
Small packages, 2" x 2" x 0.45"
■
Industry-standard pinouts
■
Fully isolated, 1500Vdc guaranteed
■
Guaranteed efficiencies to 82%
■
–40 to +100°C operating temperature
■
Modifications and customs for OEM’s
For your mid-range power requirements, it’s hard to beat the combination of low
cost, proven reliability and outstanding electrical performance offered by the
15-20W, dual-output models of C&D’s new A-Series DC/DC converters. These
highly efficient, rugged converters combine straightforward circuit topologies, the
newest components, proven SMT-on-pcb construction methods, and highly repeatable automatic-assembly techniques. Their superior durability is substantiated by a
rigorous in-house qualification program that includes HALT (Highly Accelerated Life
Testing).
The ultra-wide input voltage ranges of the A-Series duals (4.7-7.5V for "D5A"
models, 9-36V for "D12A" models and 18-75V for "D48A" models) make them excellent candidates for battery-powered systems or for distributed power architectures.
Their ±5, ±12 or ±15 Volt outputs cover virtually all standard applications.
These popular power converters are fully isolated (1500Vdc guaranteed) and
display excellent line and load regulation (with specs as low as ±0.3% max. for
line and ±0.5% max. for load). They are completely I/O protected (input overvoltage
shutdown and reverse-polarity protection, output current limiting and overvoltage
protection) and contain input (pi type) and output filtering to reduce noise. They
require no external components and offer true "plug-and-play" convenience.
These extremely reliable, cost-effective power converters are housed in standard
2" x 2" x 0.45" metal packages coated with electrically non-conductive materials.
They offer industry-standard pinouts and are ideally suited for high-volume computer, telecom/datacom, instrumentation and ATE applications.
+VIN
(1)
+VOUT
(5)
COMMON
(6)
–VOUT
(7)
–VIN
(2)
ON/OFF
CONTROL
(4)
PWM
CONTROLLER
OPTO
ISOLATION
Figure 1. Simplified Schematic
Typical topology is shown.
www.cd4power.com
REFERENCE &
ERROR AMP
TRIM
(8)
A Series
1 5 - 2 0 W, D UA L O U T P U T D C / D C C O N V E RT E R S
Performance Specifications and Ordering Guide
➀
Output
Input
Typ.
Max.
Line
Load ➂
VIN Nom.
(Volts)
Min.
Typ.
Package
(Case,
Pinout)
BWR-5/1500-D5A
±5
±1500
50
100
±0.5%
±1.0%
5
4.7-7.5
75/3750
79%
80%
C4, P7
BWR-5/1700-D12A
±5
±1700
75
100
±0.3%
±0.5%
24
9-36
15/753
80.5%
83%
C4, P7
BWR-5/1700-D48A
±5
±1700
75
100
±0.3%
±0.5%
48
18-75
15/377
81%
83%
C4, P7
BWR-12/625-D5A
±12
±625
75
120
±0.5%
±1.0%
5
4.7-7.5
75/3750
79%
81%
C4, P7
BWR-12/830-D12A
±12
±830
75
100
±0.3%
±0.5%
24
9-36
30/1000
81.5%
83%
C4, P7
BWR-12/830-D48A
±12
±830
75
100
±0.4%
±0.5%
48
18-75
15/510
81%
83%
C4, P7
BWR-15/500-D5A
±15
±500
75
150
±0.5%
±1.0%
5
4.7-7.5
75/3659
80%
82%
C4, P7
BWR-15/670-D12A
±15
±670
75
100
±0.3%
±0.5%
24
9-36
30/979
82%
83%
C4, P7
BWR-15/670-D48A
±15
±670
75
100
±0.3%
±0.5%
48
18-75
15/484
82%
84%
C4, P7
VOUT
(Volts)
Model
➀
➁
➂
➃
IOUT
(mA)
R/N (mVp-p) ➁
Regulation (Max.)
Range
(Volts)
IIN ➃
(mA)
Efficiency
Typical at TA = +25°C under nominal line voltage and full-load conditions unless otherwise noted.
Ripple/Noise (R/N) measured over a 20MHz bandwidth.
Balanced loads, 20% to 100% load.
Nominal line voltage, no-load/full-load conditions.
M echanical S pecifications
P art N umber S tructure
B WR - 12 / 830 - D48 A - C
Output Configuration:
B = Bipolar
RoHS-6 Compliant*
2.00
(50.80)
A-Series
High Reliability
Input Voltage Range:
D5 = 4.7-7.5 Volts (5V nominal)
D12 = 9-36 Volts (24V nominal)
D48 = 18-75 Volts (48V nominal)
Wide Range Input
Nominal Output Voltages:
±5, ±12 or ±15 Volts
0.45
(11.43)
ME T A L C A S E
Case C4
IN S U LA T E D B A S E
0.040 ±0.002 D IA .
(1.016 ±0.051)
0.20 MIN
(5.08)
Maximum Output Current
in mA from each output
1.800
(45.72)
0.10
(2.54)
* Contact C&D Technologies for availability
5
0.200
(5.08)
temperature derating
6
1
20
2
19
16
8
C
Output Power (Watts)
15
2.00
(50.80)
4
B
17
7
0.400
(10.16)
A
18
1.200
(30.48)
3 E Q . SP. @
0.400 ( 10.16)
0.100
(2.54)
14
0.40
(10.16)
B O T T O M V IE W
13
12
DIMENSIONS ARE IN INCHES (MM)
11
10
BWR-5/1500-D5A
BWR-5/1700-D12A
BWR-5/1700-D48A
BWR-12/625-D5A
BWR-12/830-D12A
BWR-12/830-D48A
BWR-15/500-D5A
BWR-15/670-D12A
BWR-15/670-D48A
9
8
7
6
5
4
3
C
B
B
C
A
A
C
A
A
I/O Connections
Pin
1
2
3
4
5
6
7
8
2
1
0
–40
0
40
45
50
55
60
65
70
75
80
85
90
95
100
Ambient Temperature (°C)
www.cd4power.com
2
Function P7
+Input
–Input
No Pin
On/Off Control
+Output
Common
–Output
Trim
Notes:
For "D5A" and "D12A" models,
the case is connected to
pin 2 (–VIN).
For "D48A" models, the case
is connected to pin 1 (+VIN).
A Series
1 5 - 2 0 W, D UA L O U T P U T D C / D C C O N V E RT E R S
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted. ➀
Absolute Maximum Ratings
Input
Input Voltage Range:
D5A Models
D12A Models
D48A Models
4.7-7.5 Volts (5V nominal)
9-36 Volts (24V nominal)
18-75 Volts (48V nominal)
Input Current
See Ordering Guide
Input Filter Type 
Pi
Overvoltage Shutdown:
D5A Models
D12A Models
D48A Models
10 Volts
40 Volts
80 Volts
Reverse-Polarity Protection
Yes (Instantaneous, 10A maximum)
On/Off (Sync.) Control (Pin 4) 
TTL high = off, low (or open) = on
±1.5%, maximum
±1%, maximum
Temperature Coefficient
±0.02% per °C
Ripple/Noise (20MHz BW) 
See Ordering Guide
12 Volts
44 Volts
88 Volts
Input Reverse-Polarity Protection
Current must be <10A. Brief duration only. Fusing recommended.
Output Overvoltage Protection
±5V Outputs
±12V Outputs
±15V Outputs
6.8 Volts, limited duration
15 Volts, limited duration
18 Volts, limited duration
Output Current
Current limited. Max. current and
short-circuit duration are model
dependent.
Output
VOUT Accuracy (50% load):
±5V Outputs
±9/12/15V Outputs
Input Voltage:
D5A Models
D12A Models
D48A Models
Storage Temperature
–40 to +105°C
Lead Temperature (soldering, 10 sec.)
+300°C
These are stress ratings. Exposure of devices to any of these conditions may adversely
affect long-term reliability. Proper operation under conditions other than those listed in the
Performance/Functional Specifications Table is not implied.
Line/Load Regulation
See Ordering Guide
Efficiency
See Ordering Guide
Isolation Voltage 
1500Vdc, minimum
Isolation Capacitance
550pF
Floating Outputs
Current Limiting
Auto-recovery
Overvoltage Protection
Zener/transorb clamps, magnetic feedback
Since these are isolated DC/DC converters, their outputs are "floating." Any
BWR model may be configured to produce an output of 10V, 24V or 30V
(for ±5V, ±12V or ±15V models, respectively) by applying the load across
the +Output and –Output pins (pins 5 and 7), with either output grounded.
The Common pin (pin 6) should be left open. Minimum 20% loading is
recommended under these conditions. The total output voltage span may be
externally trimmed as described below.
TECHNICAL NOTES
Dynamic Characteristics
Transient Response (50% load step)
200µsec max. to ±1.5% of final value
Switching Frequency
165kHz (±15kHz)
Environmental
Operating Temperature (ambient):
Without Derating
With Derating
–40 to +50/55/60°C (Model dependent)
to +100°C (See Derating Curves)
Storage Temperature
–40 to +105°C
Flammability
Filtering and Noise Reduction
All A-Series BWR 15-20 Watt DC/DC Converters achieve their rated ripple
and noise specifications without the use of external input/output capacitors.
In critical applications, input/output ripple and noise may be further reduced
by installing electrolytic capacitors across the input terminals and/or low-ESR
tantalum or electrolytic capacitors across the output terminals. Output capacitors should be connected between their respective output pin (pin 5 or 7) and
Common (pin 6) as shown in Figure 2. The caps should be located as close
to the power converters as possible. Typical values are listed in the tables
below. In many applications, using values greater than those listed will yield
better results.
UL 94V-0
Physical
Dimensions
2" x 2" x 0.45" (51 x 51 x 11.4mm)
Shielding
5-sided
Case Connection:
D5A and D12A Models
D48A Models
Pin 2 (–VIN)
Pin 1 (+VIN)
Case Material
Corrosion resistant steel with
non-conductive, epoxy-based, black
enamel finish and plastic baseplate
Pin Material
Gold-plated copper alloy
Weight
2.7 ounces (75.6 grams)
➀ These converters require a minimum 20% loading on each output to maintain specified
regulation. Operation under no-load conditions will not damage these devices; however
they may not meet all listed specifications.
➁ Application-specific internal input/output filtering can be recommended and perhaps added internally upon request. Contact C&D Applications Engineering for details.
➂ Applying a voltage to the Control pin when no input power is applied to the converter can
cause permanent damage to the converter.
➃ "D48A" models have BASIC, "D5A" and "D12A" models have Functional insulation.
Devices can be screened or modified for higher guaranteed isolation voltages.
Contact C&D Applications Engineering for details.
To Reduce Input Ripple
D5A Models
D12A Models
D48A Models
47µF, 16V
20µF, 50V
20µF, 100V
To Reduce Output Ripple
±5V Outputs
±9/12/15V Outputs
47µF, 10V, Low ESR
22µF, 20V, Low ESR
In critical, space-sensitive applications, C&D may be able to tailor the internal
input/output filtering of these units to meet your specific requirements. Contact our Applications Engineering Group for additional details.
www.cd4power.com
3
A Series
1 5 - 2 0 W, D UA L O U T P U T D C / D C C O N V E RT E R S
+OUTPUT
1
CIN
5
+OUTPUT
+
+INPUT
1
COUT
+INPUT
COMMON
6
+
COMMON
2
TRIM
+
–INPUT
2
COUT
6
LOAD
8
–INPUT
7
–OUTPUT
–OUTPUT
Figure 2. Using External Capacitors to Reduce
Input/Output Ripple/Noise
5
7
20k
5-10
Turns
LOAD
Figure 3a. Trim Connections Using a Trimpot
Input Fusing
Certain applications and/or safety agencies may require the installation of
fuses at the inputs of power conversion components. For C&D A-Series
BWR 15-20 Watt DC/DC Converters, you should use slow-blow type fuses
with values no greater than the following:
VIN Range
D5A
D12A
D48A
+OUTPUT
1
+INPUT
Fuse Value
LOAD
TRIM
6A
4A
2A
2
5
–INPUT
COMMON
8
6
LOAD
7
–OUTPUT
On/Off Control
The On/Off Control pin (pin 4) may be used for remote on/off operation. A
TTL logic high (+2 to +5 Volts, 250µA max.) applied to pin 4 disables the
converter. A TTL logic low (0 to +0.8 Volts, 70µA max.), or no connection,
enables the converter. Control voltages should be referenced to pin 2
(–Input). Applying a voltage to the Control pin when no input power is applied
to the converter can cause permanent damage to the converter.
Figure 3b. Fixed-Value Trim Down Resistor
Synchronization
+OUTPUT
In critical applications employing multiple switching DC/DC converters, it may
be desirable to intentionally synchronize the switching of selected converters
(so the system noise can be reduced with notch filtering) or to purposely
desynchronize the converters (to lessen the current-carrying requirements on
intermediate dc buses). For multiple A-Series Converters, an external clock
can be applied to pin 4 (Control) of each device. It should be a square wave
with a maximum 1µsec "high" duration and an amplitude between +2V and
+5V (see On/Off Control) referenced to pin 2 (–Input). The frequency of the
synchronizing clock should be higher than that of any individual converter.
Therefore, it should be 185kHz ±5kHz.
1
+INPUT
COMMON
TRIM
2
5
6
8
LOAD
–INPUT
7
–OUTPUT
Figure 3c. Fixed-Value Trim Up Resistor
Output Trimming
The total output voltage span, from +Output (pin 5) to –Output (pin 7) may
be trimmed ±5% via a single external trimpot or fixed resistor. The trimpot
should be connected as shown in Figure 3a with its wiper connected to pin 8
(Trim). A trimpot can be used to determine the value of a single fixed resistor
which should be connected as shown in Figures 3b and 3c. Connect the
resistor between pin 8 (Trim) and pin 5 (+Output) to trim "down" the output
voltages. Connect the resistor between pins 8 and 7 (–Output) to trim "up"
the output voltages. Fixed resistors should be metal-film types with absolute
TCR’s less than 100ppm/°C to ensure stability.
.
www.cd4power.com
4
LOAD
BWR-5/1700-D48A Radiated Emissions
EN 55022 Class B, 10 Meters
Converter Output = ±5Vdc @ ±1.6A
C U S TO M C A PA B I L I T I E S
C&D’s world-class design, development and manufacturing team stands
ready to work with you to deliver the exact power converter you need for
your demanding, large volume, OEM applications. And ... we’ll do it on time
and within budget!
80
70
Radiated Emissions (dBµV/M)
60
Our experienced applications and design staffs; quick-turn prototype capability; highly automated, SMT assembly facilities; and in-line SPC qualitycontrol techniques combine to give us the unique ability to design and
deliver any quantity of power converters to the highest standards of quality
and reliability.
We have compiled a large library of DC/DC designs that are currently used
in a variety of telecom, medical, computer, railway, aerospace and industrial
applications. We may already have the converter you need.
50
EN 55022 Class B Limit
40
30
20
10
0
Radiated Emissions
–10
–20
Contact us. Our goal is to provide you the highest-quality, most cost-effective
1000
100
Frequency (MHz)
E M I R A D I AT E D E M I S S I O N S
Quality and Reliability
If you’re designing with EMC in mind, please note that all of C&D’s BWR
15-20 Watt A-Series DC/DC Converters have been characterized for radiated and conducted emissions in our new EMI/EMC laboratory. Testing is
conducted in an EMCO 5305 GTEM test cell utilizing EMCO automated EMC
test software. Radiated emissions are tested to the limits of FCC Part 15,
Class B and CISPR 22 (EN 55022), Class B. Correlation to other specifications can be supplied upon request. Radiated emissions plots to FCC and
CISPR 22 for model BWR-5/1700-D48A appear below. Published EMC test
reports are available for each model number. Contact C&D’s Applications
Engineering Department for more details.
The A-Series are the first DC/DC Converters to emerge from C&D’s new,
company-wide approach to designing and manufacturing the most reliable
power converters available. The five-pronged program draws our Quality
Assurance function into all aspects of new-product design, development,
characterization, qualification and manufacturing.
Design for Reliability
Design for Reliability is woven throughout our multi-phased, new-productdevelopment process. Design-for-reliability practices are fully documented
and begin early in the new-product development cycle with the following
goals:
1. To work from an approved components/vendors list ensuring the use of
reliable components and the rigorous qualification of new components.
2. To design with safety margins by adhering to a strict set of derating
guidelines and performing theoretical worst-case analyses.
3. To locate potential design weaknesses early in the product-development
cycle by using extensive HALT (Highly Accelerated Life Testing).
4. To prove that early design improvements are effective by employing a
thorough FRACA (Failure Reporting Analysis and Corrective Action)
system.
BWR-5/1700-D48A Radiated Emissions
FCC Part 15 Class B, 3 Meters
Converter Output = ±5Vdc @ ±1.6A
80
70
Radiated Emissions (dBµV/M)
60
FCC Class B Limit
50
40
30
HALT Testing
20
The goal of the accelerated-stress techniques used by C&D is to force device
maturity, in a short period of time, by exposing devices to excessive levels of
"every stimulus of potential value." We use HALT (Highly Accelerated Life
Testing) repeatedly during the design and early manufacturing phases to
detect potential electrical and mechanical design weaknesses
that could result in possible future field failures.
10
0
Radiated Emissions
–10
–20
1000
100
Frequency (MHz)
During HALT, prototype and pre-production DC/DC converters are subjected
to progressively higher stress levels induced by thermal cycling, rate of
temperature change, vibration, power cycling, product-specific stresses (such
as dc voltage variation) and combined environments. The stresses are not
meant to simulate field environments but to expose any weaknesses in a
product’s electro/mechanical design and/or assembly processes. The goal
of HALT is to make products fail so that device weaknesses can be analyzed
and strengthened as appropriate. Applied stresses are continually stepped
up until products eventually fail. After corrective actions and/or design
changes, stresses are stepped up again and the cycle is repeated until the
"fundamental limit of the technology" is determined.
www.cd4power.com
5
A Series
1 5 - 2 0 W, D UA L O U T P U T D C / D C C O N V E RT E R S
C&D has invested in a Qualmark OVS-1 HALT tester capable of applying
voltage and temperature extremes as well as 6-axis, linear and rotational,
random vibration. A typical HALT profile (shown above) consists of thermal
cycling (–55 to +125°C, 30°C/minute) and simultaneous, gradually increasing, random longitudinal and rotational vibration up to 20G’s with load cycling
and applied-voltage extremes added as desired. Many devices in C&D’s new
A-Series could not be made to fail prior to reaching either the limits of the
HALT chamber or some previously known physical limit of the device. We
also use the HALT chamber and its ability to rapidly cool devices to verify
their "cold-start" capabilities.
In-Line Process Controls and Screening
Qualification
Rapid Response to Problems
A combination of statistical sampling and 100% inspection techniques keeps
our assembly line under constant control. Parameters such as solder-paste
thickness, component placement, cleanliness, etc. are statistically sampled,
charted and fine tuned as necessary. Visual inspections are performed by
trained operators after pick-and-place, soldering and cleaning operations.
Units are 100% electrically tested prior to potting. All devices are temperature
cycled, burned-in, hi-pot tested and final-electrical tested prior to external
visual examination, packing and shipping.
C&D employs an outstanding corrective-action system to immediately
address any detected shortcomings in either products or processes. Whenever our assembly, quality or engineering personnel spot a product/process
problem, or if a product is returned with a potential defect, we immediately
perform a detailed failure analysis and, if necessary, undertake corrective
actions. Over time, this system has helped refine our assembly operation to
yield one of the lowest product defect rates in the industry.
For each new product, electrical performance is verified via a comprehensive
characterization process and long-term reliability is confirmed via a rigorous
qualification procedure. The qual procedure includes such strenuous tests as
thermal shock and 500 hour life. Qual testing is summarized below.
Typical HALT Profile
100
80
40
40
20
20
0
0
Random Vibration (G's)
Temperature (°C)
60
–20
–40
10
20
30
40
50
60
70
80
90
Test Time (minutes)
Qualification Testing
Qualification Test
Method/Comments
HALT
C&D in-house procedure
High Temperature Storage
Max. rated temp., 1,000 hours
Thermal Shock
10 cycles, –55 to +125°C
Temperature/Humidity
+85°C, 85% humidity, 48 hours
Lead Integrity
C&D in-house procedure
Life Test
+70°C, 500 hours*
Marking Permanency
C&D in-house procedure
End Point Electrical Tests
Per product specification
* Interim electrical test at 200 hours.
®
C&D Technologies, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.cd4power.com
ISO 9001 REGISTERED
Tucson (Az), Tel: (800) 547 2537, email: [email protected]
Canada:
Toronto, Tel: (866) 740 1232, email: [email protected]
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany: München, Tel: +49 (0)89-544334-0, email: [email protected]
email: [email protected]
DS-0323A
USA:
05/14/07
© 2007 C&D Technologies, Inc.
C&D Technologies, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical
information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting
of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice.
6
Japan:
Tokyo, Tel: 3-3779-1031, email: [email protected]
Osaka, Tel: 6-6354-2025, email: [email protected]
Website: www.cd4power.jp
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
Similar pages