Keysight Technologies E4982A LCR Meter 1 MHz to 300 MHz/500 MHz/1 GHz/3 GHz Data Sheet 02 | Keysight | E4982A LCR Meter - Data Sheet Definitions Specification (spec.): Warranted performance. Specifications include guardbands to account for the expected statistical performance distribution, measurement uncertainties, and changes in performance due to environmental conditions. Supplemental information is intended to provide information that is helpful for using the instrument but that is not guaranteed by the product warranty. Typical (typ.): Describes performance that will be met by a minimum of 80% of all products. It is not guaranteed by the product warranty. Supplemental performance data (SPD): Represents the value of a parameter that is most likely to occur; the expected mean or average. It is not guaranteed by the product warranty. General characteristics: A general, descriptive term that does not imply a level of performance. 03 | Keysight | E4982A LCR Meter - Data Sheet Basic Measurement Characteristic Measurement parameters Impedance parameters |Z|, |Y|, Ls, Lp, Cs, Cp, Rs, Rp, X, G, B, D, Q, Øz [°], Øz [rad], Øy [°], Øy [rad], User defined parameter (A maximum of four parameters can be displayed at one time.) Measurement range Impedance parameters 140 mΩ to 4.8 kΩ (Frequency = 1 MHz, Averaging factor = 8, Measurement time mode = 3, Oscillator level = 1 dBm, Measurement uncertainty ≤ ± 10%, Calibration is performed within 23 °C ± 5 °C, Measurement is performed within ± 5 °C from the calibration temperature) Source Characteristics Frequency Range 1 MHz to 300 MHz (Option 030) 1 MHz to 500 MHz (Option 050) 1 MHz to 1 GHz (Option 100) 1 MHz to 3 GHz (Option 300) Resolution 100 kHz Uncertainty ± 10 ppm (23 °C ± 5 °C) ± 20 ppm (5 °C to 40 °C) Oscillator level Cable Length = 1m: Power range (When 50 Ω LOAD is connected to test port) –40 dBm to 1dBm Current range (When SHORT is connected to test port) 0.0894 mArms to 10 mArms Voltage range (When OPEN is connected to test port) 4.47 mVrms to 502 mVrms Uncertainty (When 50 Ω LOAD is connected to test port) (23 °C ± 5 °C) ± 2 dB (frequency ≤ 1 GHz) ± 3 dB (frequency > 1 GHz) (5 °C to 40 °C) ± 4 dB (frequency ≤ 1 GHz) ± 5 dB (frequency > 1 GHz) Resolution 0.1 dB (When the unit is set at mV or mA, the entered value is rounded to 0.1 dB resolution.) Cable Length = 2m (When option 002 is used): Power range Subtract the following attenuation from the power (setting value) at 1 m cable length: Attenuation [dB] = 0.42 √f (f: Frequency [GHz]) Uncertainty (When 50 Ω LOAD is connected to test port) (23 °C ± 5 °C) ± 3 dB (frequency ≤ 1 GHz) ± 4 dB (frequency > 1 GHz) (5 °C to 40 °C) ± 5 dB (frequency ≤ 1 GHz) ± 6 dB (frequency > 1 GHz) Resolution 0.1 dB (When the unit is set at mV or mA, the entered value is rounded to 0.1 dB resolution.) Output impedance Output impedance 50 Ω (nominal) 04 | Keysight | E4982A LCR Meter - Data Sheet Measurement Accuracy Condition for definition of accuracy: –– 23 °C ± 5 °C –– 7-mm connector of 3.5-mm-7-mm adapter connected to 3.5-mm terminal of test heads Basic measurement uncertainty (Typical) 0.45 % Measurement uncertainty When OPEN/SHORT/LOAD calibration is performed: Z,Y ± (Ea + Eb) % ± (E + E ) rad a b 100 L, C, X, B ± (Ea + Eb) × (1 + D2 x ) % R, G ± (Ea + Eb) × (1 + Q 2 x ) % at Dx tan Ea + Eb <1 100 Especially, at Dx ± 2 x 1 ± Dx tan ± 0.1 +E (1 + D ) tan E 100 b b Eb + Eb 100 Ea + Eb 100 Q at Q x tan Ea + Eb <1 100 Especially, at 10 Ea + Eb Qx ± 10 (1 + Q ) tan 2 x Eb + Eb 100 E + E 1 ± Q x tan b b 100 ± Q 2x Ea + Eb 100 05 | Keysight | E4982A LCR Meter - Data Sheet Measurement uncertainty When OPEN/SHORT/LOAD/Low Loss capacitance calibration is performed (SPD): Z,Y ± (Ea + Eb) % ± Ec rad 100 2 2 % 2 % L, C, X, B ± (E + E ) + (E D ) R, G ± (E + E ) + (E Q ) x 100 ± ± a b c x 2 a b c (1 + D ) tan Ec 100 1 m Dx tan Ec 100 2 x Ec 100 Q at Q x tan Ec <1 100 ± (1 + Q ) tan Ec 100 1 ± Q x tan Ec 100 2 x ± Q 2x Ec 100 x 06 | Keysight | E4982A LCR Meter - Data Sheet Definition of each parameter Dx = Measurement value of D Qx = Measurement value of Q Ea = Within 23 ± 5 °C from the calibration temperature. Measurement accuracy applies when the calibration is performed at 23 ± 5 °C. When the calibration is performed beyond 23 ± 5 °C, the measurement accuracy decreases to half that described. Measurement Time: Mode 1 Oscillator level = 1 dBm ± 0.54 % @ 1 MHz ≤ frequency ≤ 100 MHz ± 0.62 % @ 100 MHz < frequency ≤ 500 MHz ± 0.92 % @ 500 MHz < frequency ≤ 1 GHz ± 2.05 % @ 1 GHz < frequency ≤ 1.8 GHz ± 4.42 % @ 1.8 GHz < frequency ≤ 3 GHz –20 dBm ≤ Oscillator level < 1 dBm ± 0.66 % @ 1 MHz ≤ frequency ≤ 100 MHz ± 0.74 % @ 100 MHz < frequency ≤ 500 MHz ± 1.11 % @ 500 MHz < frequency ≤ 1 GHz ± 2.36 % @1 GHz < frequency ≤ 1.8 GHz ± 4.81 % @ 1.8 GHz < frequency ≤ 3 GHz -33 dBm ≤ Oscillator level < –20 dBm ± 1.13 % @ 1 MHz ≤ frequency ≤ 100 MHz ± 1.22 % @ 100 MHz < frequency ≤ 500 MHz ± 1.84 % @ 500 MHz < frequency ≤ 1 GHz ± 3.54 % @1 GHz < frequency ≤ 1.8 GHz ± 6.35 % @ 1.8 GHz < frequency ≤ 3 GHz Oscillator level < –33 dBm ± 2.08 % @ 1 MHz ≤ frequency ≤ 100 MHz ± 2.26 % @ 100 MHz < frequency ≤ 500 MHz ± 2.27 % @ 500 MHz < frequency ≤ 1 GHz ± 4.34 % @ 1 GHz < frequency ≤ 1.8 GHz ± 7.60 % @ 1.8 GHz < frequency ≤ 3 GHz Mode 2 Oscillator level = 1 dBm ± 0.52 % @ 1 MHz ≤ frequency ≤ 100 MHz ± 0.59 % @ 100 MHz < frequency ≤ 500 MHz ± 0.89 % @ 500 MHz < frequency ≤ 1 GHz ± 1.99 % @ 1 GHz < frequency ≤ 1.8 GHz ± 4.34 % @ 1.8 GHz < frequency ≤ 3 GHz –20 dBm ≤ Oscillator level < 1 dBm ± 0.58 % @ 1 MHz ≤ frequency ≤ 100 MHz ± 0.66 % @ 100 MHz < frequency ≤ 500 MHz ± 0.98 % @ 500 MHz < frequency ≤ 1 GHz ± 2.14 % @ 1 GHz < frequency ≤ 1.8 GHz ± 4.54 % @ 1.8 GHz < frequency ≤ 3 GHz –33 dBm ≤ Oscillator level < –20 dBm ± 0.81 % @ 1 MHz ≤ frequency ≤ 100 MHz ± 0.90 % @ 100 MHz < frequency ≤ 500 MHz ± 1.35 % @ 500 MHz < frequency ≤ 1 GHz ± 2.74 % @ 1 GHz < frequency ≤ 1.8 GHz ± 5.31 % @ 1.8 GHz < frequency ≤ 3 GHz Oscillator level < –33 dBm ± 1.30 % @ 1 MHz ≤ frequency ≤ 100 MHz ± 1.44 % @ 100 MHz < frequency ≤ 500 MHz ± 1.44 % @ 500 MHz < frequency ≤ 1 GHz ± 2.92 % @ 1 GHz < frequency ≤ 1.8 GHz ± 5.59 % @ 1.8 GHz < frequency ≤ 3 GHz 07 | Keysight | E4982A LCR Meter - Data Sheet Definition of each parameter (continued) Ea = Mode 3 Oscillator level = 1 dBm ± 0.51 % @ 1 MHz ≤ frequency ≤ 100 MHz ± 0.59 % @ 100 MHz < frequency ≤ 500 MHz ± 0.87 % @ 500 MHz < frequency ≤ 1 GHz ± 1.97 % @ 1 GHz < frequency ≤ 1.8 GHz ± 4.32 % @ 1.8 GHz < frequency ≤ 3 GHz –20 dBm ≤ Oscillator level < 1 dBm ± 0.55 % @ 1 MHz ≤ frequency ≤ 100 MHz ± 0.63 % @ 100 MHz < frequency ≤ 500 MHz ± 0.94 % @ 500 MHz < frequency ≤ 1 GHz ± 2.08 % @ 1 GHz < frequency ≤ 1.8 GHz ± 4.46 % @ 1.8 GHz < frequency ≤ 3 GHz –33 dBm ≤ Oscillator level < –20 dBm ± 0.65 % @ 1 MHz ≤ frequency ≤ 100 MHz ± 0.80 % @ 100 MHz < frequency ≤ 500 MHz ± 1.20 % @ 500 MHz < frequency ≤ 1 GHz ± 2.50 % @ 1 GHz < frequency ≤ 1.8 GHz ± 5.00 % @ 1.8GHz < frequency ≤ 3 GHz Oscillator level < –33 dBm ± 1.00 % @ 1 MHz ≤ frequency ≤ 100 MHz ± 1.20 % @ 100 MHz < frequency ≤ 500 MHz ± 1.20 % @ 500 MHz < frequency ≤ 1 GHz ± 2.50 % @ 1 GHz < frequency ≤ 1.8 GHz ± 5.00 % @ 1.8 GHz < frequency ≤ 3 GHz Eb = (|Zx| : Measurement value of |Z|) Ec (F : Frequency Zs = MHz) Within 23 ± 5 °C from the calibration temperature. Measurement accuracy applies when the calibration is performed at 23 ± 5 °C. When the calibration is performed beyond 23 ± 5 °C, the measurement accuracy decreases to half that described. (F: Frequency [MHz]) Measurement Time Mode 1 Oscillator level = 1 dBm, Average factor ≥ 8 ± (14 + 0.5 × F) [mΩ] Oscillator level = 1 dBm, Average factor < 8 ± (19 + 0.5 × F) [mΩ] –20 dBm ≤ Oscillator level < 1 dBm, Average factor ≥ 8 ± (20 + 0.5 × F) [mΩ] –20 dBm ≤ Oscillator level < 1 dBm, Average factor < 8 ± (37 + 0.5 × F) [mΩ] –33 dBm ≤ Oscillator level < –20 dBm, Average factor ≥ 8 ± (36 + 0.5 × F) [mΩ] –33 dBm ≤ Oscillator level < –20 dBm, Average factor < 8 ± (110 + 0.5 × F) [mΩ] Oscillator level < –33 dBm ± (248 + 0.5 × F) [mΩ] 08 | Keysight | E4982A LCR Meter - Data Sheet Definition of each parameter (continued) Zs = Mode 2 Mode 3 Yo = Oscillator level= 1 dBm, Average factor ≥ 8 ± (13 + 0.5 × F) [mΩ] Oscillator level= 1 dBm, Average factor < 8 ± (15 + 0.5 × F) [mΩ] –20 dBm ≤ Oscillator level < 1 dBm, Average factor ≥ 8 ± (16 + 0.5 × F) [mΩ] –20 dBm ≤ Oscillator level < 1 dBm, Average factor < 8 ± (24 + 0.5 × F) [mΩ] –33 dBm ≤ Oscillator level< -20 dBm, Average factor ≥ 8 ±(24+0.5×F) [mΩ] –33 dBm ≤ Oscillator level < –20 dBm, Average factor < 8 ± (64 + 0.5 × F) [mΩ] Oscillator level < –33 dBm ± (133 + 0.5 × F) [mΩ] Oscillator level = 1 dBm, Average factor ≥ 8 ± (12 + 0.5 × F) [mΩ] Oscillator level = 1 dBm, Average factor < 8 ± (14 + 0.5 × F) [mΩ] –20 dBm ≤ Oscillator level < 1 dBm, Average factor ≥ 8 ± (15 + 0.5 × F) [mΩ] –20 dBm ≤ Oscillator level < 1 dBm, Average factor < 8 ± (20 + 0.5 × F) [mΩ] –33 dBm ≤ Oscillator level < –20 dBm, Average factor ≥ 8 ± (20 + 0.5 × F) [mΩ] –33 dBm ≤ Oscillator level < –20 dBm, Average factor < 8 ± (50 + 0.5 × F) [mΩ] Oscillator level < –33 dBm ± (100 + 0.5 × F) [mΩ] Within 23 ± 5 °C from the calibration temperature. Measurement accuracy applies when the calibration is performed at 23 ± 5 °C. When the calibration is performed beyond 23 ± 5 °C, the measurement accuracy decreases to half that described. (F: Frequency [MHz]) Measurement Time: Mode 1 Mode 2 Oscillator level = 1 dBm, Average factor ≥ 8 ± (22 + 0.15 × F) [µS] Oscillator level = 1 dBm, Average factor < 8 ± (28 + 0.15 × F) [µS] –20 dBm ≤ Oscillator level < 1 dBm, Average factor ≥ 8 ± (30 + 0.15 × F) [µS] –20 dBm ≤ Oscillator level < 1 dBm, Average factor < 8 ± (53 + 0.15 × F) [µS] –33 dBm ≤ Oscillator level < –20 dBm, Average factor ≥ 8 ± (52 + 0.15 × F) [µS] –33 dBm ≤ Oscillator level < –20 dBm, Average factor < 8 ± (110 + 0.15 × F) [µS] Oscillator level < –33 dBm ± (247 + 0.15 × F) [µS] Oscillator level = 1 dBm, Average factor ≥ 8 ± (20 + 0.15 × F) [µS] Oscillator level = 1 dBm, Average factor < 8 ± (23 + 0.15 × F) [µS] –20 dBm ≤ Oscillator level < 1 dBm, Average factor ≥ 8 ± (24 + 0.15 × F) [µS] –20 dBm ≤ Oscillator level < 1 dBm, Average factor < 8 ± (35 + 0.15 × F) [µS] –33 dBm ≤ Oscillator level< –20 dBm, Average factor ≥ 8 ± (35 + 0.15 × F) [µS] –33 dBm ≤ Oscillator level< –20 dBm, Average factor < 8 ± (63 + 0.15 × F) [µS] Oscillator level < –33 dBm ± (133 + 0.15 × F) [µS] 09 | Keysight | E4982A LCR Meter - Data Sheet Definition of each parameter (continued) Yo = Mode 3 Oscillator level = 1 dBm, Average factor ≥ 8 ± (19 + 0.15 × F) [µS] Oscillator level = 1 dBm, Average factor < 8 ± (22 + 0.15 × F) [µS] –20 dBm ≤ Oscillator level < 1 dBm, Average factor ≥ 8 ± (22 + 0.15 × F) [µS] –20 dBm ≤ Oscillator level < 1 dBm, Average factor < 8 ± (30 + 0.15 × F) [µS] –33 dBm ≤ Oscillator level < –20 dBm, Average factor ≥ 8 ± (30 + 0.15 × F) [µS] –33 dBm ≤ Oscillator level < –20 dBm, Average factor < 8 ± (50 + 0.15 × F) [µS] Oscillator level < –33 dBm ± (100 + 0.15 × F) [µS] Measurement error may exceed the specifications described above at 90 MHz due to the E4982A’s spurious characteristics. 10 | Keysight | E4982A LCR Meter - Data Sheet 10000 1000 1000 100 10 1 0.1 1 10 100 [MHz] 1000 0.8% 1% 2% 5% 10% 10 0.1 10000 1000 1000 100 100 10 0.1 1 10 100 [MHz] 1000 0.8% 1% 2% 5% 10% Figure 3. Measurement Time: Mode 1, Oscillator Level = 1 dBm, Averaging Factor < 8, Temperature Deviation ≤ 5 °C 0.1 1000 100 100 0.1 1 10 100 [MHz] 1000 Figure 5. Measurement Time: Mode 2, Oscillator Level = 1 dBm, Averaging Factor ≥ 8, Temperature Deviation ≤ 5 °C 1000 1 10 100 [MHz] 1000 0.8% 1% 2% 5% 10% Figure 4. Measurement Time: Mode 3, Oscillator Level = 1 dBm, Averaging Factor ≥ 8, Temperature Deviation ≤ 5 °C 1000 1 100 [MHz] 1 10000 0.8% 1% 2% 5% 10% 10 10 10000 10 1 0.8% 1% 2% 5% 10% Figure 2. Measurement Time: Mode 2, Oscillator Level = 1 dBm, Averaging Factor < 8, Temperature Deviation ≤ 5 °C 10000 1 |Z| [Ω] 100 1 |Z| [Ω] |Z| [Ω] Figure 1. Measurement Speed: Mode 3, Oscillator Level = 1 dBm, Averaging Factor < 8, Temperature Deviation ≤ 5 °C |Z| [Ω] 10000 |Z| [Ω] |Z| [Ω] Examples of Calculated Impedance Measurement Accuracy 10 1 0.1 1 10 100 [MHz] 1000 0.8% 1% 2% 5% 10% Figure 6. Measurement Time: Mode 1, Oscillator Level = 1 dBm, Averaging Factor ≥ 8, Temperature Deviation ≤ 5 °C 11 | Keysight | E4982A LCR Meter - Data Sheet Timing Chart and Measurement Time (SPD) Timing chart of handler interface signal T1 T3 T4 T5 T6 T7 T2 Trigger signal /INDEX /EOM /READY_FOR_TRIG Figure 7. Timing chart of handler interface signal Cycle Time Timing Test condition T4 + Measurement T5 data calculation time (EOM) T4 + T5 + Ready_for_Trig T6 setting time T7 Trigger wait time 1 point meas (Preset) 1 point meas. Ls-Q meas. — Max. Measurement time (INDEX) 1 point meas (Preset) Median T4 Min. — Max. T3 Trigger response time (INDEX, EOM) — — 2 µs — — Off — <50 μs — Off Off — <50 μs Off Off — 1.6 ms On Off — Off Off Off Mode 3 Median Off 2 µs Mode 2 Min. — Max. T2 Trigger response time of Ready_ for_Trig Median Off Mode 1 (100 MHz) Min. Off Max. Comparator — Median Rdc meas. T1 Trigger pulse width Min. Screen Setting Mode 1 (1 MHz) 2 µs — — 2 µs — — <50 μs — <50 μs — <50 μs — <50 μs — <50 μs — <50 μs 1.6 ms 0.9 ms 0.9 ms 2.1 ms 2.1 ms 3.7 ms 3.7 ms 4.5 ms 4.5 ms 3.8 ms 3.8 ms 5.0 ms 5.0 ms 6.6 ms 6.6 ms — 1.6 ms 1.8 ms 0.9 ms 1.1 ms 2.1 ms 2.3 ms 3.7 ms 4.0 ms On — 1.7 ms 1.9 ms — 1.0 ms 1.2 ms — 2.2 ms 2.7 ms — 3.8 ms 4.1 ms Off Off — 1.8 ms 2.2 ms — 1.1 ms 1.4 ms — 2.3 ms 2.8 ms — 3.9 ms 4.4 ms Off On — 1.9 ms 2.3 ms — 1.2 ms 1.9 ms — 2.4 ms 3.3 ms — 4.0 ms 4.5 ms On Off — 5.1 ms 5.6 ms — 4.4 ms 4.9 ms — 5.6 ms 6.1 ms — 7.2 ms 7.7 ms On On — 5.2 ms 5.7 ms — 4.5 ms 4.9 ms — 5.7 ms 6.3 ms — 7.2 ms 7.8 ms — — 0 — — 0 — — 0 — — 0 — — Condition: Display Off or :DISP:UPD OFF, Trigger delay=0, Point delay=0 E4982A OS: Windows 7 (Serial Prefix: MY523) 12 | Keysight | E4982A LCR Meter - Data Sheet Test condition for Measurement Time The measurement time of E4982A is scattered to some extent by an overhead of the internal operation system and other conditions, so it is difficult to define the specification of handler interface timing. Thus, for your reference, we provide “SPD” data on it in table by defining the following test condition. Median: Median value of running one minute of measurement data Max.: Maximum value of running one minute of measurement data NOTE 1. The instrument’s operating system sometimes suffers interruptions during measurement, and we sometimes observe an extremely large overhead in handler interface timings. The table excludes such special cases, thus you can sometimes see timing over the maximum value data shown in the table. If you make a handshake using the READY_FOR_TRIGGER signal of the handler interface, your test system can continue to work correctly regardless of such an irregular measurement time drift. 2. If your system communicates with external devices, you will see longer timing results than those on the table. 3. In the case of using a bus trigger in the GPIB/LAN/USB system instead of the handler interface, you should measure the test cycle time for yourself, because the system performance depends heavily on the system parameters. Of course, you will see much longer test cycle times from your system software overhead. T4 T5 /INDEX /EOM Sorting result output (Previous sorting results) Ts Internal process Meas. condition setup Tt Tp Tr Tm Rdc Measurement meas. Trigger delay time (User’s setup) Meas. point delay time (User’s setup) Figure 8. Measurement time T4 for single point measurement Sorting results Meas. data math. 13 | Keysight | E4982A LCR Meter - Data Sheet T4 T5 /INDEX /EOM Sorting result output (Previous sorting results) Meas. point 1 Ts Tt Tp Tr Internal process Meas. condition setup Trigger delay time (User’s setup) Tm Meas. point 2 Meas. point N Ts Tp Ts Tp Tm Meas. condition Measurement setup Rdc meas. Meas. condition setup Sorting results Meas. point delay time (User’s setup) Tm Meas. data math. N: Numbers of meas. Measurement Point in the table Meas. point delay time (User’s setup) Figure 9. Measurement time T4 for list measurement Data transfer time (Typical) Mode 3 Required time for FETCh? command (ms) Data transfer format Number of measurement points GPIB 1 0.4 0.4 0.6 ASCII 2 0.7 0.4 0.6 3 1.0 0.4 0.7 Binary USB LAN (Socket) 1 0.5 1.1 0.6 2 0.5 1.1 0.5 3 0.6 1.1 0.6 Host computer: DELL PRECISION 390 Intel Core2Duo 6300 1.86 GHz/RAM: 2GB GPIB I/F: Keysight Technologies, Inc. PCI GPIB E2078A/82350A IO Lib: Keysight IO Libraries Suite 16.1.14931.0 E4982A Setting: Frequency: OSC Level: Average: Display: List Measurement Measurement Parameter: Measurement Signal Level Monitor: Comparator: Rdc Measurement: 100 MHz 0 dBm 1 Off Ls-Q (Parameters No.3 and 4: Off) Off Off Off 14 | Keysight | E4982A LCR Meter - Data Sheet Measurement Support Functions Error correction function Available calibration and compensation OPEN/SHORT/LOAD calibration Connect OPEN, SHORT, and LOAD standards to the desired reference plane and measure each kind of calibration data. The reference plane is called calibration reference plane. Low-Loss capacitor calibration Connect the dedicated standard (Low-Loss capacitor) to the calibration reference plane and measure the calibration data. Port extension compensation (Fixture selection) When a device is connected to the terminal that is extended from the calibration reference plane, set the electrical length between the calibration plane and the device contact. Select a model number of the registered test fixtures in the E4982A's softkey menu or enter the electrical length for user's test fixture. OPEN/SHORT compensation When a device is connected to the terminal that is extended from the calibration reference plane, make OPEN and/or SHORT states at the device contact and measure each kind of compensation date. Calibration/compensation data measurement point Data measurement points Same as measurement points which are set in the measurement point setup display. (Changing the frequency, oscillator level, or measurement speed settings after the calibration or compensation makes the calibration and compensation data invalid.) DC resistance (Rdc) measurement Measurement range 0.1 Ω to 100 Ω Measurement resolution 1 mΩ Test Signal Level 1 mA (maximum) Error correction OPEN/SHORT/LOAD Calibration, OPEN/SHORT Compensation. (Changing the frequency or oscillator level settings after the calibration or compensation makes the calibration and compensation data invalid.) Measurement uncertainty (SPD) (At averaging factor=128, within ± 5 °C from the calibration temperature. Measurement accuracy applies when the calibration is performed at 23 °C ± 5 °C. When the calibration is performed beyond 23 °C ± 5 °C, the measurement accuracy decreases to half that described.) Trigger function Trigger mode Internal, External (external trigger input connector or handler interface), Bus (GPIB, USB or LAN), Manual (front key) Measurement time Time Mode 1 (Short), Mode 2 (Mid), Mode 3 (Long) Averaging function Setting range 1 to 100 (integer) List measurement function Number of measurement points 201 points for each table (maximum) Number of tables 8 tables 15 | Keysight | E4982A LCR Meter - Data Sheet Test signal level monitor function Uncertainty of monitor value (SPD) A: Uncertainty of oscillator level [dB], B: Uncertainty of impedance measurement [%] Front panel Ports Type N (3 ea.) connected to test head Display Type/size 10.4 inch TFT color LCD Resolution XGA (1024 × 768) 1 USB 1 Universal serial bus jack, Type A configuration; female; provides connection to mouse, key board, printer or USB stick memory. Valid pixels are 99.99% and more. Below 0.01% of fixed points of black, blue, green or red are not regarded as failure. Measurement terminal (at test head) Connector type 3.5-mm (female) connector (can be converted to 7-mm connector using the 3.5 mm-7 mm adapter) Rear panel External reference signal input connector Frequency 10 MHz ± 10 ppm (Typ.) Level 0 dBm ± 3 dB (Typ.) Input impedance 50 Ω (nominal) Connector type BNC (female) Internal reference signal output connector Frequency 10 MHz ± 10 ppm (Typ.) Uncertainty of frequency Same as frequency uncertainty described in “Source Characteristics”. Level 0 dBm ± 3 dB into 50 Ω (Typ.) Input impedance 50 Ω (nominal) Connector type BNC (female) External trigger signal input connector Level LOW threshold voltage: 0.5 V HIGH threshold voltage: 2.1 V Input level range: 0 to +5 V Pulse Width (Tp) ≥ 2usec (SPD). See the following figure for definition of Tp Polarity Positive or negative (Selective) Connector type BNC (female) Tp Tp 5V 5V 0V Tp Tp Positive trigger signal Figure 10. Definition of pulse width (Tp) 0V Negative trigger signal 16 | Keysight | E4982A LCR Meter - Data Sheet Interface GPIB 24-pin D-Sub (Type D-24), female; compatible with IEEE-488. IEEE-488 interface specification is designed to be used in environment where electrical noise is relatively low. LAN or USBTMC interface is recommended to use at the higher electrical noise environment. USB host port Universal serial bus jack, Type A configuration; female; provides connection to mouse, key board, printer or USB stick memory. USB (USBTMC ) interface port Universal serial bus jack, Type B configuration (4 contacts inline); female; provides connection to an external PC; compatible with USBTMC-USB488 and USB 2.0.LA USB Test and Measurement Class (TMC) interface that communicates over USB, complying with the IEEE 488.1 and IEEE 488.2 standards. LAN 10/100/1000 Base T Ethernet, 8-pin configuration; auto selects between the two data rates Video output 15-pin mini D-Sub; female; drives VGA compatible monitors Handler interface Connector type 36-pin centronics, female Signal type Negative logic, opto-isolated, open collector output Output signal BIN sort result (BIN 1 to BIN 13, OUT_OF_GOOD_BINS) DC resistance pass/fail (DCR_OUT_OF_RANGE) Overload (OVLD) Alarm (ALARM) End of analog measurement (INDEX) End of measurement (EOM) Ready for trigger (READY_FOR_TRIG) Input signal Eternal trigger (EXT_TRIG) Key lock (KEY_LOCK) Pin location See the following figure. Refer to Help for the definition of each pin. Figure 11. Pin assignment 17 | Keysight | E4982A LCR Meter - Data Sheet Line power Frequency 47 to 63 Hz Voltage 90-264 VAC (Vpeak > 120 V) VA max 300 VA max. EMC, safety, environment and compliance EMC European Council Directive 2004/108/EC IEC 61326-1:2012 EN 61326-1:2013 CISPR 11:2009 +A1:2010 EN 55011: 2009 +A1:2010 Group 1, Class A IEC 61000-4-2:2008 EN 61000-4-2:2009 4 kV CD / 8 kV AD IEC 61000-4-3:2006 +A1:2007 +A2:2010 EN 61000-4-3:2006 +A1:2008 +A2:2010 3 V/m, 80-1000 MHz, 1.4 - 2.0 GHz / 1V/m, 2.0 - 2.7 GHz, 80% AM IEC 61000-4-4:2004 +A1:2010 EN 61000-4-4:2004 +A1:2010 1 kV power lines / 0.5 kV signal lines IEC 61000-4-5:2005 EN 61000-4-5:2006 0.5 kV line-line / 1 kV line-ground IEC 61000-4-6:2008 EN 61000-4-6:2009 3 V, 0.15-80 MHz, 80% AM IEC 61000-4-8:2009 EN 61000-4-8:2010 30A/m, 50/60Hz IEC 61000-4-11:2004 EN 61000-4-11:2004 0.5-300 cycle, 0% / 70% NOTE-1: When tested at 3 V/m according to EN61000-4-3, the measurement accuracy will be within specifications over the full immunity test frequency range except when the analyzer frequency is identical to the transmitted interference signal test frequency. NOTE-2: When tested at 3 V according to EN61000-4-6, the measurement accuracy will be within specifications over the full immunity test frequency range except when the analyzer frequency is identical to the transmitted interference signal test frequency. ICES-001:2006 Group 1, Class A AS/NZS CISPR11:2004 Group 1, Class A KN11, KN61000-6-1 and KN61000-6-2 Group 1, Class A 18 | Keysight | E4982A LCR Meter - Data Sheet Safety European Council Directive 2006/95/EC IEC 61010-1:2001 / EN 61010-1:2001 Measurement Category I Pollution Degree 2 Indoor Use NOTE-1: When tested at 3 V/m according to EN61000-4-3, the measurement accuracy will be within specifications over the full immunity test frequency range except when the analyzer frequency is identical to the transmitted interference signal test frequency. NOTE-2: When tested at 3 V according to EN61000-4-6, the measurement accuracy will be within specifications over the full immunity test frequency range except when the analyzer frequency is identical to the transmitted interference signal test frequency. CAN/CSA C22.2 No. 61010-1-04 Measurement Category I Pollution Degree 2 Indoor Use Environment This product complies with the WEEE Directive (2002/96/EC) marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as a “Monitoring and Control instrumentation” product. Do not dispose in domestic household waste. To return unwanted products, contact your local Keysight office, or see http://www.keysight.com/environment/product/ for more information. Compliance Class C 19 | Keysight | E4982A LCR Meter - Data Sheet Analyzer Environmental Specifications and Dimensions Operating environment Temperature +5 °C to +40 °C Error-corrected temperature range 23 °C (± 5 °C) with < 5 °C deviation from calibration temperature Humidity 20% to 80% at wet bulb temperature < +29 °C (non-condensation) Altitude 0 to 2,000 m (0 to 6,561 feet) Vibration 0.21 G maximum, 5 Hz to 500 Hz Non-operating environment Temperature –10 °C to +60 °C Humidity 20% to 90% at wet bulb temperature < 40 °C (non-condensation) Altitude 0 to 4,572 m (0 to 15,000 feet) Vibration 2.1 G maximum, 5 Hz to 500 Hz Dimensions, weight Weight Figure 12. Front view Main unit: 13 kg, test head: 250 g with plate 20 | Keysight | E4982A LCR Meter - Data Sheet Figure 13. Rear view Figure 14. Side view 21 | Keysight | E4982A LCR Meter - Data Sheet Figure 15. Test head 22 | Keysight | E4982A LCR Meter - Data Sheet From Hewlett-Packard through Agilent to Keysight For more than 75 years, we‘ve been helping you unlock measurement insights. Our unique combination of hardware, software and people can help you reach your next breakthrough. Unlocking measurement insights since 1939. 1939 THE FUTURE myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a full one-year warranty on all accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. Keysight Infoline www.keysight.com/find/service Keysight’s insight to best in class information management. Free access to your Keysight equipment company reports and e-library. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 11 2626 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-07-24-15) www.keysight.com/find/e4982a www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System This information is subject to change without notice. © Keysight Technologies, 2012 - 2015 Published in USA, November 18, 2015 5990-9882EN www.keysight.com