RUGGED GALAXY SERIES TRUE ON-LINE UPS TM 1 - 1.5 - 2KVA APPLICATIONS APP P L I C ATIONS Utilizing field proven transformer isolated topology, this family of rugged UPS is suitable for harsh environments and can be customized for unique applications including: Shelters HMMWVs Tactical Systems Mobile Systems Shipboard Power Ground support MIL-STD-810 MIL-STD-461 MIL-STD-901 MIL-STD-167 ELECTRIC NOVA ELE ECTRIC www.novaelectric.com [email protected] A Leader in UPS Technology since 1966 - 500VA-500+KVA MADE IN USA TRUE ONLINE RUGGED SINEWAVE UPS CAN MEET MIL-STD-810, MIL-STD-1399, MIL-STD-901, MIL-STD-704, & MIL-STD-461 OPTIONALLY APPLICATIONS SPECIFICATIONS The rugged Galaxy Series UPS is designed to provide years of reliable service in harsh shock, vibration, humidity, and EMI environments. Military applications include HMMVW, UAV, Shipboard, Submarine, Shelter, and Mobile Power Units. OPTIONS 400 Hz Input and/or Output MS Connector Mates Chassis Slides Internal Solid State Transfer Switch Premium 10 Year Life Wide Temperature Range Batteries RS232 or SNMP Run Time to 24+ Hours Three-Phase Input Custom Cabinets & Turnkey Solutions Rail Frequency Hz - 83, 91.66, 100, 200, or 250 Hz. ELECTRICAL Frequency: Specify 50, 60, or 400Hz Voltage Regulation: ± 1% NL to FL Frequency Regulation: ± 0.5% NL to FL Harmonic Distortion: 5% THD Power Factor: 0.7 lead to 0.7 lag Efficiency at full load: 75-80% typical Overload: 125% for 5 minutes ENVIRONMENTAL Operating Temp.: -20° to +50°C Storage Temp. Range: -20° to +50°C (extended range available) Humidity: to 95% non-condensing Elevation: 15,000 Ft. (4.572m) operating; 40,000 ft. (12.192m) non-operating Shock: 20g/11mS Audible Noise: Less than 55 dbA at 5 ft. INTERNAL BATTERIES Sealed, maintenance-free and user replaceable. 3-5 years lifetime. ALARMS & DIAGNOSTICS System Status (Green/Red) Utility Off (Red) UPS Overload (Red) UPS Off (Red) Over Temp. (Red) Low Battery (Red) Load On Utility (Red) Logic Fault (Red) (with SST Option) Alarm Contacts: Standard RS232 or SNMP Optional PROTECTIVE FEATURES AC & DC Input Circuit Breakers, Low Battery Shut Off, Overload & Thermal Protected, Input Under / Overvoltage Protected, Audible Alarm with Silence Switch MODEL SELECTION MODEL KVA INPUT OUTPUT LBS BATTERY STD. RUNTIME GRSL11-1k60-120-120 1 120VAC 120VAC, 60HZ 90 INTERNAL 15 MINUTES GRSL11-1k50-220-220 1 220VAC 220VAC, 50HZ 90 INTERNAL 15 MINUTES GRSL11-1k400-115-115 1 115VAC 115VAC, 400HZ 90 INTERNAL 15 MINUTES GRSL11-1k60-120/240A-120 1 120/240VAC, 50/60HZ 120, 60HZ 110 INTERNAL 15 MINUTES GRSL11-1.5k60-120-120 1.5 120VAC 120VAC, 60HZ 100 INTERNAL 10 MINUTES GRSL11-1.5k50-220-220 1.5 220VAC 220VAC, 50HZ 100 INTERNAL 10 MINUTES GRSL11-1.5k400-115-115 1.5 115VAC 115VAC, 400HZ 100 INTERNAL 10 MINUTES GRSL11-1.5k60-120/240A-120 1.5 120VAC, 50/60HZ 120VAC, 60HZ 119 INTERNAL 10 MINUTES GRSL11-2k60-120-120 2 120VAC, 50/60HZ 120VAC, 60HZ 110 INTERNAL 5 MINUTES GRSL11-2k50-220-220 2 220VAC 220VAC, 50HZ 110 INTERNAL 5 MINUTES GRSL11-2k400-115-115 2 115VAC 115VAC, 400HZ 110 INTERNAL 5 MINUTES GRSL11-2k60-120/240A-120 2 120/240VAC, 50/60HZ 120, 60HZ 130 INTERNAL 5 MINUTES 22.00 NAME PLATE .12 16. 77 SEE TOP COVER SCREEN BELOW FOR DETAILS AIR INTAKE (BOTH SIDES) 5.218 SYSTEM STATUS 5.218 INDICATORS 19 .00 (SEE CAPTION) BYPASS SWITCH (OPTIONAL) ALARM SILENCE AC INPUT CIRCUIT BREAKER BATTERY INPUT CIRCUIT BREAKER (J1) MS3102R AC INPUT 1.73 .344 (J3) MS3102R AC OUTPUT 18.312 AIR EXHAUST FANS (BOTH SIDES) 2.25 CHASSIS SLIDE OPTIONAL GENERAL DEVICES P/N: CTS-122 EXTENSION BRACKET P/N: 8-307-2 (OPTIONAL) 1.48 AIR INTAKE (J2) MS3102R (WITH OPTIONAL EXTERNAL BATTERY PACK) WEB : www.novaelectric.com E-Mail : [email protected] PHONE : (201) 385-0500 FAX : (201) 385-0702 (J4) 9 PIN "D" CONNECTOR DE-9SMS CHASSIS GROUND STUD 1.4-20 WITH WING-NUT NOVA ELECTRIC A Division of TECHNOLOGY DYNAMICS, INC. 100 School St., Bergenfield NJ 07621 ISO 9001