Nova GRSL11-2k400-115-115 True on-line up Datasheet

RUGGED
GALAXY SERIES
TRUE ON-LINE UPS
TM
1 - 1.5 - 2KVA
APPLICATIONS
APP
P L I C ATIONS
Utilizing field proven transformer isolated topology, this
family of rugged UPS is suitable for harsh environments
and can be customized for unique applications including:
Shelters
HMMWVs
Tactical Systems
Mobile Systems
Shipboard Power
Ground support
MIL-STD-810
MIL-STD-461
MIL-STD-901
MIL-STD-167
ELECTRIC
NOVA ELE
ECTRIC
www.novaelectric.com
[email protected]
A Leader in UPS Technology since 1966 - 500VA-500+KVA
MADE IN USA
TRUE ONLINE RUGGED SINEWAVE UPS
CAN MEET MIL-STD-810, MIL-STD-1399, MIL-STD-901, MIL-STD-704, & MIL-STD-461 OPTIONALLY
APPLICATIONS
SPECIFICATIONS
The rugged Galaxy Series UPS is designed
to provide years of reliable service in harsh
shock, vibration, humidity, and EMI
environments. Military applications include
HMMVW, UAV, Shipboard, Submarine,
Shelter, and Mobile Power Units.
OPTIONS
 400 Hz Input and/or Output
 MS Connector Mates
 Chassis Slides
 Internal Solid State Transfer Switch
 Premium 10 Year Life Wide
Temperature Range Batteries
 RS232 or SNMP
 Run Time to 24+ Hours
 Three-Phase Input
 Custom Cabinets & Turnkey Solutions
 Rail Frequency Hz - 83, 91.66, 100,
200, or 250 Hz.
ELECTRICAL
Frequency: Specify 50, 60, or 400Hz
Voltage Regulation: ± 1% NL to FL
Frequency Regulation: ± 0.5% NL to FL
Harmonic Distortion: 5% THD
Power Factor: 0.7 lead to 0.7 lag
Efficiency at full load: 75-80% typical
Overload: 125% for 5 minutes
ENVIRONMENTAL
Operating Temp.: -20° to +50°C
Storage Temp. Range: -20° to +50°C
(extended range available)
Humidity: to 95% non-condensing
Elevation: 15,000 Ft. (4.572m) operating;
40,000 ft. (12.192m) non-operating
Shock: 20g/11mS
Audible Noise: Less than 55 dbA at 5 ft.
INTERNAL BATTERIES
Sealed, maintenance-free and
user replaceable. 3-5 years lifetime.
ALARMS & DIAGNOSTICS
System Status (Green/Red)
Utility Off (Red)
UPS Overload (Red)
UPS Off (Red)
Over Temp. (Red)
Low Battery (Red)
Load On Utility (Red)
Logic Fault (Red)
(with SST Option)
Alarm Contacts: Standard
RS232 or SNMP Optional
PROTECTIVE FEATURES
AC & DC Input Circuit Breakers, Low
Battery Shut Off, Overload & Thermal
Protected, Input Under / Overvoltage
Protected, Audible Alarm with
Silence Switch
MODEL SELECTION
MODEL
KVA
INPUT
OUTPUT
LBS
BATTERY
STD. RUNTIME
GRSL11-1k60-120-120
1
120VAC
120VAC, 60HZ
90
INTERNAL
15 MINUTES
GRSL11-1k50-220-220
1
220VAC
220VAC, 50HZ
90
INTERNAL
15 MINUTES
GRSL11-1k400-115-115
1
115VAC
115VAC, 400HZ
90
INTERNAL
15 MINUTES
GRSL11-1k60-120/240A-120
1
120/240VAC, 50/60HZ
120, 60HZ
110
INTERNAL
15 MINUTES
GRSL11-1.5k60-120-120
1.5
120VAC
120VAC, 60HZ
100
INTERNAL
10 MINUTES
GRSL11-1.5k50-220-220
1.5
220VAC
220VAC, 50HZ
100
INTERNAL
10 MINUTES
GRSL11-1.5k400-115-115
1.5
115VAC
115VAC, 400HZ 100
INTERNAL
10 MINUTES
GRSL11-1.5k60-120/240A-120
1.5
120VAC, 50/60HZ
120VAC, 60HZ
119
INTERNAL
10 MINUTES
GRSL11-2k60-120-120
2
120VAC, 50/60HZ
120VAC, 60HZ
110
INTERNAL
5 MINUTES
GRSL11-2k50-220-220
2
220VAC
220VAC, 50HZ
110
INTERNAL
5 MINUTES
GRSL11-2k400-115-115
2
115VAC
115VAC, 400HZ
110
INTERNAL
5 MINUTES
GRSL11-2k60-120/240A-120
2
120/240VAC, 50/60HZ
120, 60HZ
130
INTERNAL
5 MINUTES
22.00
NAME PLATE
.12
16.
77
SEE TOP COVER
SCREEN BELOW
FOR DETAILS
AIR INTAKE
(BOTH SIDES)
5.218
SYSTEM STATUS
5.218
INDICATORS
19
.00
(SEE CAPTION)
BYPASS SWITCH
(OPTIONAL)
ALARM SILENCE
AC INPUT
CIRCUIT BREAKER
BATTERY INPUT
CIRCUIT BREAKER
(J1) MS3102R
AC INPUT
1.73
.344
(J3) MS3102R
AC OUTPUT
18.312
AIR EXHAUST
FANS
(BOTH SIDES)
2.25
CHASSIS SLIDE OPTIONAL
GENERAL DEVICES P/N: CTS-122
EXTENSION BRACKET P/N: 8-307-2 (OPTIONAL)
1.48
AIR INTAKE
(J2) MS3102R
(WITH OPTIONAL EXTERNAL BATTERY PACK)
WEB : www.novaelectric.com
E-Mail : [email protected]
PHONE : (201) 385-0500 FAX : (201) 385-0702
(J4) 9 PIN "D" CONNECTOR
DE-9SMS
CHASSIS GROUND STUD
1.4-20 WITH WING-NUT
NOVA ELECTRIC
A Division of
TECHNOLOGY DYNAMICS, INC.
100 School St., Bergenfield NJ 07621