DC-DC Converter UNIT
HU Series ( 1.8 W UNREGULATED DC-DC CONVERTER )
FEATURES
z
z
z
1000VDC ISOLATION
HIGH EFFICIENCY
INTERNAL FILTERING
LOW COST
NO EXTERNAL COMPONENTS
REQUIRED
UP TO 1.8W UNREGULATED
OUTPUT POWER
DUAL IN LINE PACKAGE
100% BURNED IN
LOW NOISE
z
MTBF > 850,000 HOURS
z
OUTPUT SPECIFICATIONS
z
z
z
z
z
z
z
Voltage Setpoint Accuracy
+/-2% max
Temperature Coefficient
+/-0.03%/ OC
Ripple & Noise (20MHz
INPUT SPECIFICATIONS
Input Voltage Range
Input Filter
+/-10% max
Capacitor Type
100mVp-p max
BW)
Line Regulation1
Load Regulation
+/-1.2% max
2
+/-8% max
Short Circuit Protection
Momentary
z
GENERAL SPECIFICATIONS
Efficiency
77%-85%
3
z
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Cooling
Isolation Voltage
1000 VDC min
Isolation Resistance
9
10 ohms min
-25 OC to +71 OC
Switching Frequency
25 KHz min
-55 OC to +125 OC
Isolation Capacitance
80pF max
Free-Air Convection
MTBF
Weight
850,000 Hours
10.1g Typ
ALL SPECIFICATIONS TYPICAL AT NOMINAL
Case Material
Non-Conductive Plastic
LINE,
Case Size
32.5mm*17mm*10.2mm
FULL
LOAD
,
AND
25
O
C
UNLESS
OTHERWISE NOTED.
1
Line Regulation is for a 1.0% change in input Voltage.
2
Load Regulation is for output load current change from 20% to 100%.
3
For 60 seconds
www.Power-Systems.de
Page: 1 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
HU Series ( 1.8 W UNREGULATED DC-DC CONVERTER )
z SELECTION GUIDE
1.8W OUTPUT
MODEL
NUMBER
HUS-0505
INPUT
OUTPUT
OUTPUT
VOLTAGE VOLTAGE CURRENT
(VDC)
(VDC)
(mA)
INPUT
CURRENT(mA)
EFF
ISOLATION
FULL
NO
(%)
(VDC)
LOAD
LOAD
5
5
360
467
40
77
1000
5
9
200
476
40
77
1000
HUS-0512
5
12
150
450
38
80
1000
HUS-0515
5
15
120
444
38
81
1000
12
5
360
192
18
78
1000
12
9
200
185
18
81
1000
HUS-1212
12
12
150
185
16
81
1000
HUS-1215
12
15
120
182
16
82
1000
HUS-2405
24
5
360
95
9
79
1000
HUS-2409
24
9
200
92
9
82
1000
HUS-2412
24
12
150
90
9
83
1000
HUS-2415
24
15
120
88
8
85
1000
HUS-4805
48
5
360
48
5
78
1000
HUS-4809
48
9
200
46
5
81
1000
HUS-4812
48
12
150
46
5
81
1000
HUS-4815
48
15
120
45
5
82
1000
HUS-0509
4
HUS-1205
HUS-1209
5
Note: Other input to output voltages may be available. Please contact factory.
4
For LAN DC-DC CONVERTER
5
For LAN DC-DC CONVERTER
www.Power-Systems.de
Page: 2 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
HU Series ( 1.8 W UNREGULATED DC-DC CONVERTER )
z MECHANICAL DIMENSIONS &
RECOMMENDED FOOTPRINT DETAILS
z SIMPLIFIED SCHEMATIC
PIN
SINGLE
1&24
+Vin
2&23
NC
10&15
-Vout
11&14
+Vout
12&13
-Vin
z TYPICAL APPLICATIONS
INPUT
+Vin
OUTPUT
+Vin
+Vout
+Vout
OSCILLATOR
DRIVER
-Vin
DC-DC
CONVERTER
-Vout
-Vin
www.Power-Systems.de
Page: 3 / 5
LOAD
-Vout
Version: 4-Oct-02
DC-DC Converter UNIT
HU Series ( 1.8 W UNREGULATED DC-DC CONVERTER )
z TYPICAL PERFORMANCE CUREVES
Specifications typical at ta=25 OC,nominal input voltage , rated output current unless otherwise specified.
VOUT VS LOAD(9Vout Models)
6.4
10.4
6.0
10.0
Vout(V)
Vout(V)
VOUT VS LOAD(5Vout Models)
5.6
9.6
5.2
9.2
4.8
8.8
0
90
180
270
0
360
VOUT VS LOAD(12Vout Models)
150
200
VOUT VS LOAD(15Vout Models)
13.5
16.5
13.0
16.0
Vout(V)
Vout(V)
100
Output Current(mA)
Output Current(mA)
12.5
12.0
15.5
15.0
14.5
11.5
0
38
75
112
0
150
30
60
90
120
Output Current(mA)
Output Current(mA)
EFFICIENCY VS LOAD
DERATING CURVE
2.0
80.0
60.0
40.0
20.0
0.0
0
20
40
60
80
100
OUTPUT POWER(W)
EFFICIENCY(%)
50
1.6
0.8
0.4
0.0
% OF RATED LOAD(%)
www.Power-Systems.de
SAFE
OPERATING
AREA
1.2
-25
0
25
50
70
100
TA(degree C)
Page: 4 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
HU Series ( 1.8 W UNREGULATED DC-DC CONVERTER )
HU SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
Output filtering is required for operation. A minimum of 10uF is needed. Output
capacitance may be increased for additional filtering, not to exceed 220uF.
To meet the reflected ripple requirements of the converter, an input impedance of
less than 0.5 ohm from DC to 250KHz is required.
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground
and connecting –OUT as the negative output.
FOR MORE INFORMATION CALL:
Power Systems – The Power Solution
Ilsfeld-Auenstein ( Germany ) Dörnet 8
Tel: + 49 / 70 62 / 67 59 – 6
E-mail: [email protected]
Home Page: www.Power-Systems.de
www.Power-Systems.de
Page: 5 / 5
Fax: + 49 / 70 62 / 67 59 -80
Version: 4-Oct-02
Similar pages