MPS ADC316 2w, miniature sip, single & dual output dc/dc converter Datasheet

ADC300 SERIES
2W, Miniature SIP, Single & Dual Output DC/DC Converters
Selection Guide
Model
Number
The ADC300 series is an excellent
selection for a variety of applications
including distributed power
systems, mixed analog/digital
subsystems, portable test
equipments, local power networks
and battery backed systems.
Output
Current
mA
500
400
165
133
±200
±83
±66
500
400
165
133
±200
±83
±66
500
400
165
133
±200
±83
±66
19.5 [0.77]
2.54 [0.100]
2.3 [0.09]
2
4
5
6
0.50 [0.020]
% Typ.
73
76
80
80
77
79
79
74
78
82
83
79
82
82
74
77
81
82
79
81
82
Load
Regulation
% Max.
11
11
7
7
10
7
7
8
8
5
5
8
5
5
8
8
5
5
8
5
5
Pin
Singles
Duals
1
2
4
5
6
+Vin
-Vin
-Vout
No Pin
+Vout
+Vin
-Vin
-Vout
Common
+Vout
Case Size –
19.5x7.6x10.2mm (0.77x0.30x0.40inch)
18.5 [0.73]
1
Efficiency
Pin Connections
7.6 [0.30]
The series consists of 21 models
with input voltages of 5V, 12V and
24VDC which offers standard output
voltages of 3.3V, 5V, 12V, 15V,
±5V, ±12V and ±15VDC for a wide
choice.
Mechanical Dimensions
10.2 [0.40]
MPS Industries ADC300 DC/DC's
are specially designed to provide
higher power to 2W in a miniature
SIP package.
24
(21.6 – 26.4)
3.2 [0.13]
•
•
•
12
(10.8 – 13.2)
1.3 [0.05]
•
Efficiency up to 83%
1000VDC Isolation
MTBF > 2,000,000 Hours
Low Cost
Input 5, 12 and 24VDC
Output 3.3, 5, 12, 15,
±5, ±12 and ±15VDC
Temperature Performance
-40°C to +85°C
UL 94V-0 Package Material
Internal SMD Construction
Industry Standard Pinout
5
(4.5 – 5.5)
0.5 [0.02]
•
•
•
•
•
•
ADC301
ADC302
ADC303
ADC304
ADC305
ADC306
ADC307
ADC311
ADC312
ADC313
ADC314
ADC315
ADC316
ADC317
ADC321
ADC322
ADC323
ADC324
ADC325
ADC326
ADC327
Output
Voltage
VDC
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
0.25 [0.010]
Key Features
Input
Voltage
VDC
Case Material –
Non-Conductive Black Plastic
Weight –
2.7g (0.10Oz)
Tolerance
Millimeters
X.X±0.25
X.XX±0.13
Inches
X.XX±0.01
X.XXX±0.005
Pin
±0.05
±0.002
2463 208th Street, Ste. 205
Tel: (310) 533-1455
http://www.mpsind.com
Torrance, CA 90501
Fax: (310) 533-1853
E-mail: [email protected]
ADC300 SERIES
2W, Miniature SIP, Single & Dual Output DC/DC Converters
Absolute Maximum Ratings
Parameter
General Characteristics
Min.
Max. Units
5VDC Input Models
-0.7
9
VDC
Input Surge Voltage
12VDC Input Models
(1000mS)
-0.7
18
VDC
24VDC Input Models
-0.7
30
VDC
Lead Temperature
(1.5mm from case for 10sec.)
---
260
°C
Internal Power Dissipation
---
650
mW
Parameter
Isolation
Voltage
Isolation
Resistance
Isolation
Capacitance
Conditions
Min.
Typ.
Max.
Units
60 Seconds
1000
---
---
VDC
500VDC
1000
---
---
MΩ
100kHz, 1V
---
80
120
pF
50
80
100
kHz
2
---
---
MHrs
Min.
Typ.
Max.
Units
---
±1.2
±1.5
%
Switching
Frequency
MIL-HDBK-217F
@25°C
Ground Benign
Exceeding the unit absolute maximum ratings could cause damage.
These are not continuous operating ratings.
MTBF
Environmental Characteristics
Output Characteristics
Parameter
Conditions
Min.
Ambient
-40
85
°C
Line Regulation
Case
-40
90
°C
Load Regulation
-40
125
°C
Ripple & Noise
--95
Free-Air Convection
%
Short Circuit
Operating
Temperature
Operating
Temperature
Storage
Temperature
Humidity
Cooling
Max. Units
Parameter
Conditions
For Vin Change of
1%
See Selection Guide
Io = 20% to 100%
20MHz BW
---
100
150
%
mV P-P
0.5 Second Max.
Maximum Capacitive Load
Models by Output Voltage
(Each Output on Duals)
Derating Curve
400LFM
100LFM
Output Power (%)
200LFM
60
Natural
convection
40
20
0
¡ã
-40
50
Duals
Units
470
390
uF
Notes:
100
80
Singles
60
70
80
Ambient Temperature
90
]
100
110
1. Specifications typical at Ta=+25°C, resistive load, nominal input
voltage, rated output current unless otherwise noted.
2. These power converters require a minimum output load to maintain
specified regulation.
3. Operation under no-load conditions will not damage these modules;
however, they may not meet all specifications listed.
4. All DC/DC converters should be externally fused at the front end for
protection.
5. Other input and output voltage may be available, please contact
factory.
6. All specifications subject to change without notice.
7. For detailed data sheet, please contact us.
2463 208th Street, Ste. 205
Tel: (310) 533-1455
http://www.mpsind.com
Torrance, CA 90501
Fax: (310) 533-1853
E-mail: [email protected]
Similar pages