MA300RWI Series Wide 2:1 Input, 3W, High 3 kVDC Isolation DC/DC Converters Electrical Specifications Key Features: • 3W Output Power • 2:1 Input Voltage Range Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Min. 5 VDC Input 12 VDC Input 24 VDC Input 48 VDC Input 5 VDC Input 12 VDC Input 24 VDC Input 48 VDC Input (Pi) Filter Input Start Voltage • 3,000 VDC Isolation • 32 Standard Models • Single & Dual Outputs Under Voltage Shutdown • Compact DIP Case • -40°C to +85°C Operation • Industry Standard Pin-Out 1.5 kV Isolation Models Available Input Filter Typ. Max. 4.5 9.0 18.0 36.0 4.0 8.5 17.5 35.5 Units Max. ±2.0 ±2.0 ±1.0 ±1.0 70 500 ±5.0 ±0.02 Units % % % % mV P - P µSec % %/°C % Max. Units VDC M pF kHz VDC VDC Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) Transient Recovery Time, See Note 2 Transient Response Deviation Temperature Coefficient Output Overload Protection Output Short Circuit Conditions Min. Dual Output, Balanced Loads VIN = Min to Max IOUT = 0% to 100% See Note 1 Typ. ±0.5 ±0.3 ±0.3 300 ±3.0 ±0.01 Foldback 120 150 Continuous (Autorecovery) 25% Load Step Change General 4:1 Input Range Models Available Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency EMI Characteristics Parameter Radiated Emissions Conducted Emissions ESD RS EFT Surge CS Conditions 60 Seconds 500 VDC 100 kHz/1.0V Min. 3,000 1,000 Typ. 300 90 Standard See Note 3 See Note 3 EN 55022 EN 55022 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 Level Class A Class A Criteria A; ±8 kV Air ±6 kV Contact Criteria A; 10V/m Criteria A; ±2 kV Criteria A; ±1 kV Criteria A; 10V/m Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Conditions Ambient Case Min. -40 Typ. +25 -50 Free Air Convection RH, Non-condensing Max. +85 +100 +125 Units °C °C °C 95 % 1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm) Non-Conductive Black Plastic (UL94-V0) 0.45 Oz (12.8g) Reliability Specifications Parameter MTBF Conditions MIL HDBK 217F, 25°C, Gnd Benign Min. 1.0 Typ. Max. Units MHours Min. -0.7 -0.7 -0.7 -0.7 Typ. Max. 11.0 25.0 50.0 100.0 260 Units Absolute Maximum Ratings Parameter Conditions Input Voltage Surge (1 Sec) Lead Temperature 5 VDC Input 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case for 10 Sec Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC °C www.micropowerdirect.com Model Selection Guide Input Model Number MA305S-03RWI MA305S-05RWI MA305S-12RWI MA305S-15RWI MA305S-24RWI MA305D-05RWI MA305D-12RWI MA305D-15RWI MA312S-03RWI MA312S-05RWI MA312S-12RWI MA312S-15RWI MA312S-24RWI MA312D-05RWI MA312D-12RWI MA312D-15RWI MA324S-05RWI MA324S-05RWI MA324S-12RWI MA324S-15RWI MA324S-24RWI MA324D-05RWI MA324D-12RWI MA324D-15RWI MA348S-03RWI MA348S-05RWI MA348S-12RWI MA348S-15RWI MA348S-24RWI MA348D-05RWI MA348D-12RWI MA348D-15RWI Voltage (VDC) Current (mA) Nominal Range Full-Load No-Load 5 4.5 - 9.0 514 65 5 4.5 - 9.0 641 65 5 4.5 - 9.0 732 65 5 4.5 - 9.0 732 65 5 4.5 - 9.0 741 65 5 4.5 - 9.0 649 65 5 4.5 - 9.0 741 65 5 4.5 - 9.0 741 65 12 9.0 - 18.0 209 35 12 9.0 - 18.0 257 35 12 9.0 - 18.0 294 35 12 9.0 - 18.0 294 35 12 9.0 - 18.0 298 35 12 9.0 - 18.0 260 35 12 9.0 - 18.0 298 35 12 9.0 - 18.0 298 35 24 18.0 - 36.0 104 20 24 18.0 - 36.0 129 20 24 18.0 - 36.0 147 20 24 18.0 - 36.0 147 20 24 18.0 - 36.0 149 20 24 18.0 - 36.0 130 20 24 18.0 - 36.0 149 20 24 18.0 - 36.0 149 20 48 36.0 - 72.0 52 15 48 36.0 - 72.0 64 15 48 36.0 - 72.0 74 15 48 36.0 - 72.0 74 15 48 36.0 - 72.0 74 15 48 36.0 - 72.0 65 15 48 36.0 - 72.0 74 15 48 36.0 - 72.0 74 15 Output Voltage Current Current (VDC) (mA, Max) (mA, Min) 3.3 5.0 12.0 15.0 24.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 24.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 24.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 24.0 ±5.0 ±12.0 ±15.0 600.0 500.0 250.0 200.0 125.0 ±250.0 ±125.0 ±100.0 600.0 500.0 250.0 200.0 125.0 ±250.0 ±125.0 ±100.0 600.0 500.0 250.0 200.0 125.0 ±250.0 ±125.0 ±100.0 600.0 500.0 250.0 200.0 125.0 ±250.0 ±125.0 ±100.0 0.0 0.0 0.0 0.0 0.0 ±0.0 ±0.0 ±0.0 0.0 0.0 0.0 0.0 0.0 ±0.0 ±0.0 ±0.0 0.0 0.0 0.0 0.0 0.0 ±0.0 ±0.0 ±0.0 0.0 0.0 0.0 0.0 0.0 ±0.0 ±0.0 ±0.0 Notes: 1. When measuring output ripple, it is recommended that an external 3.3 µF ceramic capacitor be placed from the +VOUT pin to the -VOUT pin for single output units and from each output to common for dual output units. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage these units. 4. An external 220 µF/100V capacitor connected across the input pins is required to meet EN61000-4-4 and EN61000-4-5. 5. Dual output units may be connected to provide a 10, 24 or 30 VDC output. To do this, connect the load across the positive (+VOUT) and negative (-VOUT) outputs and float the output common. 6. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor be mounted close to the converter. For 5V input units a 8.2 µF is recommended, for 12V input units, a 3.3 µF; and for 24V & 48V units a 1.5 µF. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Efficiency (%, Typ) Fuse Reflected Capacitive Ripple Rating Load Current Slow-Blow (µF, Max) (mA Typ) 77 78 82 82 81 77 81 81 79 81 85 85 84 80 84 84 79 81 85 85 84 80 84 84 79 81 85 85 84 80 84 84 (mA) 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 680 470 330 220 100 ±220 ±150 ±100 680 470 330 220 100 ±220 ±150 ±100 680 470 330 220 100 ±220 ±150 ±100 680 470 330 220 100 ±220 ±150 ±100 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 600 600 600 600 600 600 600 600 300 300 300 300 300 300 300 300 150 150 150 150 150 150 150 150 For 1.5 kV Isolation, See MA300-xxRW Series Datasheet For 4:1 Inputs, See MA300-xxRU Series Datasheet Mechanical Dimensions Derating Curve Pin Connections Pin Single Dual 2, 3 9 11 14 16 22, 23 -VIN No Pin NC +V VOUT -V VOUT +VIN -VIN Common -V VOUT +V VOUT Common +VIN NC: No Connection Mechanical Notes: MicroPower Direct • All dimensions are typical in inches (mm) • Tolerance x.x = ±0.02 (±0.50) • Tolerance x.xx = ±0.01 (±0.25) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]