Artesyn LPT104-M Total power: 80 - 130 watt Datasheet

POWER
LPT100-M Series
130 Watts
Data Sheet
Total Power: 80 - 130 Watts
Input Voltage: 90 - 264 Vac
# of Outputs: Triple
SPECIAL FEATURES
ƒƒ Medical and ITE safeties
ƒƒ Active power factor correction
ƒƒ 2” x 4” footprint
ƒƒ Less than 1U high
ƒƒ EN61000-3-2 compliant
ƒƒ Remote sense
ƒƒ Power fail
ƒƒ Adjustable main output
ƒƒ Built-in Class B EMI filter
ƒƒ Overvoltage protection
ƒƒ Overload protection
ƒƒ Thermal overload protection
ƒƒ LPX100 enclosure kit available
ƒƒ RoHS compliant
Electrical Specifications
Input
Input ra­nge
90 - 264 Vac; 127 - 300 Vdc
Frequency
47 - 63 Hz
Inrush current
50 A max., cold start @ 25 °C
Efficiency
82% typical at full load
EMI/RFI
FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
Safety ground
leakage current
275 µA @ 50/60 Hz, 264 Vac input
SAFETY
ƒƒ TUV
ƒƒ UL
ƒƒ CSA
ƒƒ NEMKO
ƒƒ AUSTEL
ƒƒ CB
ƒƒ CE
60950, 60601-1
60950, 60601-1
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate & report
Mark (LVD)
Output
Maximum power
80 W for convection;
130 W with 200 LFM forced air
Adjustment range
All outputs adjustable: -20%, +10%, except for +24V output on
LPT104-M which will be -10%, +20% and 3.3 V output on the LPT101M +10%, -15%
Hold-up time
10 ms @ 130 W load, 120 Vac input
Overload protection
Short circuit protection on all outputs. Case overload
protected @ 110 - 160% above rating for V1 & V2, 150 - 250% for V3
Overvoltage protection
15 - 35% above nominal output
Logical Control
Power failure
Active LowTTL logic signal goes high 100 - 500 msec after main output;
it goes low at least 6 msec before loss of regulation
Remote sense
ompensates for 0.5 V lead drop min. Will operate without remote
C
sense connected. Reverse connection protected.
LPT100-M Series Data Sheet
Environmental Specifications
Operating temperature
0 °C to 50 °C ambient derate each output as 2.5% per degree from 50 °C to 70 °C. -20 °C start up
Storage temperature
-40 °C to +85 °C
Electromagnetic susceptibility:
Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity
Operating; non-condensing 10% to 90% RH, non-operating, non-condensing 10% - 95%
Vibration
IEC68-2-6 to the levels of IEC721-3-2
MTBF calculated
583,000 hours at full load and 25 °C ambient conditions. 230 Vac input, Bellcore
Mechanical Drawing
ADJUST POT'S
1
GND
SK2
PIN 1 (LIVE)
8
PIN 3 (NEUTRAL)
0.16
[4]
4 places mounting hole
max screw head
diameter 0.22"[5.6]
1.72 "
[43,8]
SK1
SK3
SEE DETAIL A
1
3.72 "
[94,6]
4"
[101,6]
4
0.1 "
[2,5]
max lead
protrusion
1.29 "
[32,7]
SK3
DETAIL A
0.197
[5]
min stand-off
height
2"
[50,8]
OUTPUT VOLTAGE
POWER FAIL
COMMON
(+) REMOTE SENSE
(-) REMOTE SENSE
LPT100-M Series Data Sheet
Ordering Information
Model Number
LPT101-M
LPT102-M
LPT103-M
LPT104-M
Output Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30CFM Forced Air
Peak Load
Regulation2
Ripple
P/P (PARD)3
+3.3 V
0A
13 A
18 A
20 A
±2%
50 mV
+5 V
0A
5A
9A
10 A
±5%
50 mV
+12 V
0A
1A
2.3 A
2.3 A
±5%
120 mV
+5 V
0A
13 A
18 A
20 A
±2%
50 mV
+12 V
0A
5A
9A
10 A
±5%
120 mV
-12 V
0A
1A
2A
2A
±5%
120 mV
+5 V
0A
13 A
18 A
20 A
±2%
50 mV
+15 V
0A
4A
7.2 A
8A
±5%
150 mV
-15 V
0A
1A
1.5 A
2A
±5%
150 mV
+5 V
0A
13 A
18 A
20 A
±2%
50 mV
+24 V
0A
1.5 A
3A
3.5 A
±7%
240 mV
+12 V
0A
1A
2.3 A
2.3 A
±5%
120 mV
1. Peak current lasting < 15 seconds with a maximum 10% duty cycle.
2­. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3­. Peak-to-peak with 20 mHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated
as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and
System Integrators, including through Distribution Channels. It is not intended for sale to End Users.
LPT100-M Series Data Sheet
Pin Assignments
Mating­ Connectors
Connector
LPT100-M
AC Input (SK1)
SK1
PIN 1
Live
Molex 09-50-3031
PINS: 08-52-0072
PIN 3
Neutral
AC Ground
Molex 01-90020001
PIN 1
V1out
PIN 2
V1out
DC Output (SK2) JST VHR-8N
PINS: SVH-21T-P1.1
PIN 3
GND
PIN 4
GND
PIN 5
GND
PIN 6
GND
PIN 7
V2out
PIN 8
V3out
PIN 1
Power Fail
PIN 2
GND
PIN 3
+ Remote Sense
PIN 4
- Remote Sense
SK2
SK3
Remote Sense
(SK3)
JST PHR-4; PINS: SPH-002T-PO.5S
OR
LANDWIN 2001S0400; PINS: 2005T
Artesyn Embedded Technologies Connector Kit #70-841-026,
includes all of the above
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±.02”.
3. All mounting holes should be grounded for EMI purpose
4. Mounting M1 is safety ground connection
5. Specifications are for convection rating at factory settings at 115 Vac
input 25 °C unless otherwise stated.
6. This power supply requires mounting on metal standoffs 0.20” (5 m) in
height.
7. For DC input an external DC safety rated fuse must be used.
8. Warranty: 2 year
9. Weight: 0.44 lb. / 0.20 kg
WORLDWIDE OFFICES
Americas
Europe (UK)
Asia (HK)
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and
service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names,
trademarks, or registered trademarks of their respective owners. © 2016 Artesyn Embedded Technologies, Inc.
All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal.
www.artesyn.com
For more information: www.artesyn.com/power
For support: [email protected]
LPT100-M DS 21Mar2016
Similar pages