M Series Data Sheet 50-Watt AC-DC Cassette Converters Features • RoHS lead-solder-exempt compliant1 • Rugged electrical and mechanical design • Outputs individually controlled with excellent dynamic properties • Operating ambient temperature range of –40 to 71 °C with convection cooling 1 The solder exemption refers to all the restricted materials except lead in solder. Description The M Series of AC-DC cassettes represents a broad and flexible range of power supplies for use in advanced industrial electronic systems. Features include high efficiency, reliability, low output voltage noise, and excellent dynamic response to load/line changes due to individual regulation of each output. Model Selection Output 1 Vo nom [VDC] Output 2 Output 3 Io nom [A] Model Options Vo nom [VDC] Io nom [A] 5.1 8 - - - - 100 - 240 LM1001-7R -9, E, P, D, V, A, F 12 4 - - - - 100 - 240 LM1301-7R -9, E, P, D, A, F 15 3.4 - - - - 100 - 240 LM1501-7R -9, E, P, D, A, F 24 2 - - - - 100 - 240 LM1601-7R -9, E, P, D, A, F 48 1 - - - - 100 - 240 LM1901-7R -9, E, P, D, A, F 12 2 12 2 - - 100 - 240 LM2320-7 -9, E, P, D, A, F 15 1.7 15 1.7 - - 100 - 240 LM2540-7 -9, E, P, D, A, F 5.1 5 12 0.7 12 0.7 100 - 240 LM3020-7 -9, E, P, D, V, A, F 5.1 5 15 0.6 15 0.6 100 - 240 LM3040-7 -9, E, P, D, V, A, F JUN 20, 2006 revised to JUL 21, 2006 Vo nom [VDC] Nom. Input Voltage Io nom [A] Page 1 of 4 Vi [VAC] www.power-one.com M Series Data Sheet 50-Watt AC-DC Cassette Converters Input Nom. voltage and frequency Operating voltage and frequency Inrush current limitation Output Efficiency Output voltage setting accuracy Output voltage switching noise Line regulation Load regulation continuous range continuous range by thermistor Vi nom, Vi nom, Io nom Io nom IEC/EN 61204, total Vi min - Vi max, Io nom, each output regulated Minimum load Current limitation main output Vi nom, 0 - Io nom, each output regulated not required rectangular V/I characteristic Current limitation aux. output(s) rectangular V/I characteristic Operation in parallel Hold-up time by current limitation, only main outputs Vi = 230 V AC, Io nom 100 - 240 VAC, 50 - 60, 440 Hz 85 - 264 VAC, 47 - 440 Hz up to 81% better than ±1% Vo nom typ. 50 mVpp typ. ±0.2% Vo nom typ. 0.15% Vo nom 0A typ. 110% Io nom typ. 120% Io nom typ. 90 ms Protection Input fuse Input undervoltage lockout Input overvoltage lockout Input transient protection Output Output overvoltage Overtemperature protection varistor or suppressor diode no-load, overload, and short-circuit proof suppressor diode in each output switch-off with auto restart Control Output voltage adjustment Inhibit Status indication single output types TTL input, output(s) disabled if open circuit 3 LEDs: OK, inhibit, overload 0 - 110% Vo1 nom Safety Approvals Protection degree Electric strength test voltage EN 60950, UL 1950, CSAC22.2 No. 950 units without options Input against (case + outputs) Class I equipment IP 40 2 kV AC JUN 20, 2006 revised to JUL 21, 2006 built-in T 2.5 A, 250 V AC typ. 80% Vi min typ. 110% Vi max Page 2 of 4 typ. 150% Vo nom TC typ. 100 °C www.power-one.com M Series Data Sheet 50-Watt AC-DC Cassette Converters EMC Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge Conducted disturbances Electromagnetic emissions IEC/EN 61000-4-2, level 4 (8/15 kV) IEC/EN 61000-4-3, level x (20 V/m) IEC/EN 61000-4-4, input, level 3/4 (2/4 kV) IEC/EN 61000-4-5, input, level 3/4 (2/4 kV) IEC/EN 61000-4-6, level 3 (10 V) CISPR 22/EN 55022, class I, conducted Environmental Operating ambient temperature Operating case temperature TC Storage temperature Damp heat Vibration, sinusoidal Vi nom, Io nom, convection cooled Vi nom, Io nom non operational IEC/EN 60068-2-78, 93%, 40 °C IEC/EN 60068-2-6, 10 - 60/60 - 2000 Hz Shock IEC/EN 60068-2-27, 6 ms Bump IEC/EN 60068-2-29, 6 ms Random vibration IEC/EN 60068-2-64, 20 to 500 Hz MTBF MIL-HDBK-217E, GB, 40 °C, single output models criterion A criterion A/B criterion A/B criterion A criterion B class B –25 to 71 °C –25 to 95 °C –40 to 100 °C 56 days 0.35 mm/5 gn 100 gn 40 gn Options Extended temperature range –40 to 71 °C, ambient, operating Electronic inrush current limitation Output voltage adjustment 95 - 105% Vo nom, excludes feature R Input and/or output undervoltage monitoring, excludes option V Input and/or output undervoltage monitoring (VME), excludes option D Test sockets for check of output voltage Fuse not user-accessible 4.9 gn rms 320 000 h -9 E P D0 - D9 V1 - V3 A F Pin Allocation Pin 2 5 8 11 14 17 14 17 20 23 26 29 32 Electrical determination Inhibit control input Data safe or ACFAIL Output positive Output negative Control input + Control input – Output positive Output negative Output positive Output negative Protective earth PE AC input neutral AC input phase JUN 20, 2006 revised to JUL 21, 2006 LM1000 i D or V Vo+ Vo– R G LM2000 i D or V LM3000 i D or V Vo3+ Vo3– Vo+ Vo– Vo2+ Vo2– Vo1+ Vo1– Vo2+ Vo2– Vo1+ Vo1– N L N L N L Page 3 of 4 www.power-one.com M Series Data Sheet 50-Watt AC-DC Cassette Converters Mechanical Data 32 6TE 12.1 09012 28.6 26 29 23 20 17 14 8 11 2 5 Dimensions in mm. The power supplies are designed to be inserted into a 19” rack, 160 mm long, according to IEC 60297-3. 20.5 34 100 European Projection Male connector H11 according to DIN 41 612 (Gold plated contacts on customer's request) 1.6 2TE 15 3.27 Mounting holes for retaining clips (HZZ01209) Front plate 20 103 M 3; depth = 4 mm (chassis mount) 173.7 127 168.5 159.4 Main face Measuring point for case temperatureTC 68 22 Rear face 4 Mounting plane of connector H11 (11.6) 88 111.2 (3U) 38.7 Back plate ø 4.0 ø 3.5 31.5 22.30 17.25 12.17 7.09 30.48 25.40 20.32 15.24 10.16 5.08 0 94.5 95 0 OK (LED green) Inhibit i (LED red) Potentiometer (option D or V) IoL (LED red) Test sockets (option A) Potentiometer(s) (option P) Accessories Front panels 19” (Schroff/Intermas) Mating H11 connectors with screw, solder, fast-on or press-fit terminals Connector retention facilities and code key system for connector coding Flexible PCB for connecting the converter via an H11 connector, if mounted on a PCB Chassis or wall mounting plates for frontal access Universal mounting brackets for chassis or DIN-rail mounting NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. JUN 20, 2006 revised to JUL 21, 2006 Page 4 of 4 www.power-one.com