GE GI1-1200 Miniature high voltage glass passivated rectifier Datasheet

GI1-1200 THRU GI1-1600
MINIATURE HIGH VOLTAGE GLASS PASSIVATED RECTIFIER
Reverse Voltage - 1200 to 1600 Volts
FEATURES
DO204AP
P
A
T
E
N
T
E
D
*
♦ High temperature metallurgically bonded construction
♦ Glass passivated cavity-free junction package
♦ 1.0 Ampere operation at
TA=75°C with no thermal runaway
♦ Typical IR less than 0.1µA
♦ Hermetically sealed package
♦ Capable of meeting environmental standards of
MIL-S-19500
♦ High temperature soldering guaranteed:
350°C/10 seconds, 0.375" (9.5mm) lead length,
5 lbs. (2.3kg) tension
0.034 (0.86)
0.028 (0.71)
DIA.
Forward Current - 1.0 Ampere
1.0 (25.4)
MIN.
0.240 (6.1)
MAX.
0.150 (3.8)
0.100 (2.5)
DIA.
MECHANICAL DATA
1.0 (25.4)
MIN.
Dimensions in inches and (millimeters)
*Brazed-lead assembly is covered by Patent No. 3,930,306
Case: JEDEC DO-204AP solid glass body
Terminals: Solder plated axial leads, solderable per
MIL-STD-750, Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight: 0.02 ounce, 0.56 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
SYMBOLS
GI1-1200
GI1-1400
GI1-1600
UNITS
Maximum repetitive peak reverse voltage
VRRM
1200
1400
1600
Volts
Maximum RMS voltage
VRMS
840
980
1120
Volts
Maximum DC blocking voltage
VDC
1200
1400
1600
Volts
Maximum average forward rectified current
0.375” (9.5mm) lead length at TA=75°C
I(AV)
1.0
Amp
Peak forward surge current 8.3ms single half sine-wave
superimposed on rated load (JEDEC Method)
IFSM
30.0
Amps
Maximum instantaneous forward voltage at 1.0A
3.14A
VF
1.1
1.3
Volts
Maximum DC reverse current
at rated DC blocking voltage
IR
10.0
100.0
µA
Maximum reverse recovery time (NOTE 1)
tfr
25.0
µs
Maximum forward recovery time (NOTE 2)
trr
1.0
µs
Typical junction capacitance (NOTE 3)
CJ
15.0
pF
RΘJA
55.0
°C/W
TJ,TSTG
-65 to +175
°C
TA= 25°C
TA=100°C
Typical thermal resistance (NOTE 4)
Operating junction and storage temperature range
NOTES:
(1) Measured on Tektronix Type "S" recovery plug-in, Tektronix 545 scope or equivalent IFM=20mA, IRM=2mA
(2) Measured on Tektronix Type "S" recovery plug-in, Tektronix 545 or equivalent, I FM=20mA
(3) Measured at 1.0 MHZ and applied reverse voltage of 4.0 Volts
(4) Thermal resistance from junction to ambient at 0.375" (9.5mm) lead length, P.C.B. mounted
4/98
RATINGS AND CHARACTERISTIC CURVES GI1-1200 AND GI1-1600
FIG. 2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
1.25
Ipk/IAV=π
1.0
50
60 HZ
RESISTIVE OR
INDUCTIVE LOAD
0.375" (9.5mm)
LEAD LENGTH
PEAK FORWARD SURGE CURRENT,
AMPERES
AVERAGE FORWARD RECTIFIED CURRENT,
AMPERES
FIG. 1 - FORWARD CURRENT DERATING CURVE
1.5
0.75
CAPACITANCE
LOAD
5.0
Ipk/IAV=
10
20
0.5
0.25
0
20
40
60
80
100
120
140
160
8.3ms SINGLE HALF
SINE-WAVE (JEDEC Method)
40
TA=25°C
NO LOAD
CONDITION
30
20
TJ=TJ max.
RATED LOAD
CONDITIONS
10
180
0
AMBIENT TEMPERATURE, °C
1
10
100
NUMBER OF CYCLES AT 60 HZ
FIG. 3 - TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
INSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
10
TJ=150°C
PULSE WIDTH=300µs
1% DUTY CYCLE
1
TJ=25°C
0.1
0.01
0.4
0.6
0.8
1.0
1.2
1.4
TJ=125°C
1
TJ=75°C
0.1
TJ=25°C
0.01
0
1.6
20
FIG. 5 - TYPICAL JUNCTION CAPACITANCE
30
TJ=25°C
f=1.0 MHz
Vsig=50mVp-p
10
1
1
40
60
80
PERCENT OF RATED PEAK REVERSE VOLTAGE, %
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
JUNCTION CAPACITANCE, pF
INSTANTANEOUS FORWARD CURRENT,
AMPERES
10
10
REVERSE VOLTAGE, VOLTS
100