Mitsubishi MF-10KDS-T12-070 Sonet/sdh transmitter & reciever Datasheet

MITSUBISHI (OPTICAL DEVICES)
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
DESCRIPTION
Th is p rod u ct is d e si gn e d t o pr o vi de hi g h op tic a l
pe r fo rma n ce f or SD H S TM- 6 4 /S O NE T O C-1 9 2 .
Trans mitte r uses co oled lase r in a butterfly pa ckag e
mod ule wi th dri ve red by sp eci fic i nte gra ted ci rcu it .
Re ceiver u ses PD pre amp -modul e (b utterfly packag e
mod ule) and integrated circuits for reshaping, retimin g
an d r e g e n e r a ti n g o p ti c a l s i g n a l .
FEATURES
Full SONET/SDH line up
K connector interface
-5.2V,+5V power supply target, -2.2V(TX only)
Case Temp. Range: 10 to 65 ° C
Clock recovery and digital alarm function.
APPLICATION
Short haul and long haul telecommunication systems
for SDH STM64 / SONET OC-192.
ABSOLUTE MAXIMUM RATINGS
Stress below listed absolute maximum rating may cause permanent damage to the transmitter and receiver.
Th is is a stress o nly and functional operation of the transceiver at these or any other conditions in excess of those
given in the operational sections of this data sheet is not implied.
Exposure to Absolute Maximum Rating for extended periods may affect transmitter and receiver reliability.
Tc=25°C
Parameters
Symbol
Ratings
Unit
Vcc
+5.3
V
Vee
-6.0
V
Vtt
-2.4
V
Tstg
-40 to 85
°C
Tc
10 to 65
°C
Relative humidity(non condensation)
-
10 to 80
%
Fiber bend radius
rF
32
mm
Supply voltage
Storage temperature
Operating case temperature
MITSUBISHI (OPTICAL DEVICES)
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
ELECTRICAL CHARACTERISTICS
All parameters are specified over the operating case temperature.
Measurement conditions are at 9953.28Mb/s+/-20ppm, NRZ PN223 -1 and 50%duty cycle data signal.
Vcc=+5.0V+/-5%, Vee=-5.2V+/-5%, Vtt=-2.2V+/-0.1V,Tc=10 to 65 °C, Using a PRBS 2 23 -1 pattern with a
50%Mark ratio, unless otherwise noted.
Transmitter
Parameters
Condition
Supply voltage
Supply current
Symbol
Min.
Typ.
Max.
Unit
Vee
-5.46
-5.2
-4.94
V
Vcc
4.75
5.0
5.25
V
Vtt
-2.3
-2.2
-2.1
V
Iee
-
-
1.5
A
Icc
-
-
1.0
A
Itt
-
-
1.2
A
Data / Clock input voltage (DC:50ohm)
note 1
-
Data / Clock relationship
note 5
Td
note 2,3
-
Condition
Symbol
Min.
Typ.
Max.
Unit
Vee
-5.46
-5.2
-4.94
V
Vcc
4.75
5.0
5.25
V
Iee
-
-
1.5
A
Icc
-
-
1.5
A
Function
SCFL
-20
-
+20
Shutdown, Laser Degradation, Power out
of range Alarm, Laser Over Temperature
Alarm
psec
-
Receiver
Parameters
Supply voltage
Supply current
Data output voltage (DC:50ohm)
note 4
Clock output voltage (AC:50ohm)
note 4
Data / Clock relationship
note 5
Jitter
Function
-
Td
-
note 6
-
SCFL
-
0.5
-
1.5
Vpp
-25
-
+25
psec
TBD
Loss of Signal Alarm
-
MITSUBISHI (OPTICAL DEVICES)
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
OPTICAL CHARACTERISTICS
Parameter
Symbol
Specification
Unit
ITU code
-
-
-
Min.
Max.
Min.
Max.
-
Dispersion
-
-800
+800
-130
+130
ps/nm
Pp
-
2
-
1
dB
-
1530
1565
1530
1565
-
Optical output power
Pout
-3
+3
-2
+3
dBm
Spectral width(-20dB)
-
-
0.5
-
0.5
nm
SMSR
-
30
-
30
-
dB
Ex
8.2
-
8.2
-
dB
-
-
-14
-
-13
dBm
-3
-
-3
-
dBm
Optical path penalty
S-64.2
S-64.3
-
Transmitter
Wavelength
Extinction Ratio
Receiver
Sensitivity
Overload
23
-12
note : Bit Rate 9953.28Mb/s,PRBS2 -1, BER<=10
ORDERING INFORMATION
Transmitter
Part number
ITU-code
Optical connector type
MF-10KDS-T12-060
S-64.2
FC
MF-10KDS-T12-061
S-64.2
SC
MF-10KDS-T12-070
S-64.3
FC
MF-10KDS-T12-071
S-64.3
SC
Receiver
Part number
ITU-code
Optical connector type
MF-10KDS-R13-060
S-64.2
FC
MF-10KDS-R13-061
S-64.2
SC
MF-10KDS-R13-070
S-64.3
FC
MF-10KDS-R13-071
S-64.3
SC
MITSUBISHI (OPTICAL DEVICES)
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
TRANSMITTER PIN ALLOCATION
No.
Symbol
Description
No.
Symbol
Description
1
-2.2V
Supply voltage for cooler
2
-2.2V
Supply voltage for cooler
3
GND
Ground
4
NUC
No user connection
5
LDMON
Laser Bias Monitor
6
PDMON
Laser Backface Monitor
7
DEG
Laser Degradation Alarm
8
ORA
Power Out of Range Alarm
9
LOT
Laser Over Temperature Alarm
10
SDC
Shut Down Command
11
GND
Ground
12
GND
Ground
13
GND
Ground
14
GND
Ground
15
+5V
Supply voltage
16
+5V
Supply voltage
17
+5V
Supply voltage
18
+5V
Supply voltage
19
GND
Ground
20
GND
Ground
21
GND
Ground
22
GND
Ground
23
-5.2V
Supply voltage
24
-5.2V
Supply voltage
25
-5.2V
Supply voltage
26
-5.2V
Supply voltage
27
GND
Ground
28
GND
Ground
29
GND
Ground
30
GND
Ground
RECEIVER PIN ALLOCATION
No.
Symbol
Description
No.
Symbol
Description
1
GND
Ground
2
GND
Ground
3
GND
Ground
4
LOS
Loss of signal alarm
5
NUC
No user connection
6
NUC
No user connection
7
NUC
No user connection
8
NUC
No user connection
9
NUC
No user connection
10
NUC
No user connection
11
GND
Ground
12
GND
Ground
13
GND
Ground
14
GND
Ground
15
+5V
Supply voltage
16
+5V
Supply voltage
17
+5V
Supply voltage
18
+5V
Supply voltage
19
GND
Ground
20
GND
Ground
21
GND
Ground
22
GND
Ground
23
-5.2V
Supply voltage
24
-5.2V
Supply voltage
25
-5.2V
Supply voltage
26
-5.2V
Supply voltage
27
GND
Ground
28
GND
Ground
29
GND
Ground
30
GND
Ground
MITSUBISHI (OPTICAL DEVICES)
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
GENERAL OUTLINE DRAWING
NOTE: TOLERANCES UNLESS NOTED +/-0.5
DIMENSIONS ARE IN MILLIMETERS
Transmitter
Receiver
MITSUBISHI (OPTICAL DEVICES)
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
BLOCK DIAGRAM
VCC
EA-LD Module
VCC
PD
integrated device
LD
OPT. OUT
Thermistor
Cooler
DRIVER IC
DATAin
A.T.C
DATAin
LOT
Driver IC
CLOCK
CLOCK
ORA
A.P.C
SDC
DEG
Transmitter
PD-Preamp Module
Clock recovery IC
PD
OPT. IN
DATAout
Preamp
DATAout
PLL
CLKout
CLKout
Alarm
LOS
Receiver
MITSUBISHI (OPTICAL DEVICES)
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
NOTE
NOTE1: Input interface
Transmitter
Data
Data
50ohm
0V
-0.9V
DC Coupled Interface
NOTE2: Shut down interface
OFF
H
L
ON
Transmitter
TTL
comparator
NOTE3: Laser Degradation Alarm / Power out of range Alarm / LD temperature out of range Alarm
L a s e r D e g r a d a ti o n A l a r m ( DE G ) se t s wh e n th e b i a s cu r r e n t i s a t l e a s t 7 0 % h i g h e r th a n
the maximum initial value allowed .
Alarm active: TTL LOW
P o we r o u t o f r a n g e A l a r m ( O R A ) , se t s wh e n th e o u tp u t o p t i ca l o u tp u t p o w e r i s 3 d B ( t yp . )
less than the initial optical output level.
Alarm active: TTL LOW
L a se r O ve r Te m p e r a tu r e A l a r m (L O T) , se t s wh e n t h e t e mp e r a t u r e o f L D i n c r e a s e o r
decrease more than 15deg.C from the initial temperature.
Alarm active: TTL LOW
MITSUBISHI (OPTICAL DEVICES)
MF-10KDS-T12-06x/07x
MF-10KDS-R13-06x/07x
SONET/SDH TRANSMITTER & RECIEVER
NOTE4: LVPECL Output interface
Receiver
100ohm
Data / Data
Clock / Clock
50ohm
50ohm
note:DC Couple for Data
AC Couple for Clock
NOTE5: Data and Clock relationship
Data
Data
Clock
Clock
Td
Td <
Td
20psec.
Td <
Rx
Tx
NOTE6: LOS of signal interface
Receiver
Optical signal
OFF
Signal detect
activated
ON
deactivated
H
L
Signal detect
TTL
25psec.
Similar pages